Description
Technical data
| Brand | Victron Energy |
|---|---|
| Model | SmartSolar MPPT 75/15 |
| Order code | SCC075015060R |
| Type | MPPT solar charge controller with Bluetooth and load output |
| Battery voltage (auto select) | 12/24 V |
| Rated charge current | 15 A |
| Nominal PV power, 12 V | 220 W (1a, 1b) |
| Nominal PV power, 24 V | 440 W (1a, 1b) |
| Max. PV short circuit current (2) | 15 A |
| Max. PV open circuit voltage | 75 V |
| Minimum PV voltage to start | Vbat + 5 V; thereafter minimum Vbat + 1 V (1b) |
| Peak efficiency | 98 % |
| Self-consumption, load on | 12 V: 19 mA; 24 V: 16 mA |
| Self-consumption, load off | 12 V: 10 mA; 24 V: 8 mA |
| Charge voltage “absorption” | 14.4 V / 28.8 V (adjustable) |
| Charge voltage “float” | 13.8 V / 27.6 V (adjustable) |
| Charge algorithm | multi-stage adaptive |
| Temperature compensation | −16 mV / °C resp. −32 mV / °C |
| Automatic load disconnect | yes |
|---|---|
| Max. continuous load current | 15 A |
| Low voltage load disconnect | 11.1 V / 22.2 V or 11.8 V / 23.6 V, or Battery Life algorithm |
| Low voltage load reconnect | 13.1 V / 26.2 V or 14 V / 28 V, or Battery Life algorithm |
| Protection | output short circuit, over temperature |
| Operating temperature | −30 to +60 °C (full rated output up to 40 °C) |
| Humidity | 95 %, non-condensing |
| Data communication port | VE.Direct |
| Bluetooth | yes, built-in (VictronConnect) |
| Battery sensing via Bluetooth | optionally Smart Battery Sense or BMV-712 Smart (battery voltage and temperature) |
| Stored trends data | battery voltage, current and temperature, load output current, PV voltage and PV current |
| Stored trends (number of days) | 46 |
| Colour | Blue (RAL 5012) |
| Power terminals | 6 mm² / AWG10 |
| Protection category | IP43 (electronic components), IP22 (connection area) |
| Weight | 0.6 kg |
| Dimensions (H × W × D) | 100 × 113 × 50 mm |
| Safety | EN/IEC 62109-1, UL 1741, CSA C22.2 |
Ultra-fast Maximum Power Point Tracking
The SmartSolar MPPT 75/15 is an MPPT solar charge controller that constantly looks for the most suitable operating point of the photovoltaic array. Especially in case of a clouded sky, when light intensity is changing continuously, an ultra-fast MPPT controller, according to Victron, improves energy harvest by up to 30 % compared to PWM charge controllers and by up to 10 % compared to slower MPPT controllers. The 75/15 model works with 12 V and 24 V batteries with automatic voltage selection and a charge current of 15 A. Peak efficiency is 98 %, and the self-consumption is only a few milliamps. The controller is intended for smaller photovoltaic arrays, for example in caravans, boats, garden houses and smaller backup systems.
PV array power and voltage
The nominal PV power is 220 W with a 12 V battery and 440 W with a 24 V battery. The maximum open circuit voltage is 75 V and the maximum PV short circuit current is 15 A. To start the controller, the PV voltage must exceed the battery voltage by 5 V; thereafter battery voltage plus 1 V is enough. If more PV power is connected, the controller limits the input power. A PV array with a higher short circuit current may damage the controller, so the stated limit must be respected. When designing the string, the open circuit voltage at the lowest temperature has to be taken into account; verify everything against the manufacturer’s manual and the specific panels.
Battery charging
The controller uses a multi-stage adaptive charge algorithm. The absorption voltage is 14.4 V at 12 V and 28.8 V at 24 V, the float voltage 13.8 V and 27.6 V; both values are adjustable. The algorithm is programmable; see the software section on the Victron website for details. The internal temperature sensor compensates the absorption and float charge voltage for temperature, the compensation being −16 mV/°C for 12 V and −32 mV/°C for 24 V. The fully discharged battery recovery function initiates charging even if the battery has been discharged to zero volts, and it reconnects to a fully discharged Li-ion battery with an integrated disconnect function.
Load output and Battery Life
The controller has a load output with automatic load disconnect. All loads can be connected to this output, which disconnects the load when the battery has been discharged to a pre-set voltage. The output is short circuit proof and the maximum continuous load current is 15 A. The disconnect voltage is 11.1 V / 22.2 V or 11.8 V / 23.6 V, the reconnect voltage 13.1 V / 26.2 V or 14 V / 28 V. Alternatively, the intelligent Battery Life algorithm can be chosen, which monitors the state of charge of the battery and, if needed, day by day slightly increases the load disconnect level until the harvested energy is sufficient to recharge the battery to nearly 100 %. The aim is to prevent permanent cycling between a partially charged and a discharged state, which destroys a lead-acid battery within weeks or months.
Bluetooth, VictronConnect and VE.Direct
Bluetooth is built directly into the controller. The VictronConnect app is the wireless solution to set up, monitor, update and synchronise SmartSolar charge controllers. For a wired data connection, a VE.Direct port is available, which allows connection to a Color Control GX, other GX products, a PC or other devices. The controller stores trends for 46 days: battery voltage, current and temperature, load output current, PV voltage and PV current. The charge algorithm and the day/night timing with light dimming option can be set in software; see the Victron website for details.
Battery sensing via Bluetooth
Optionally, external battery voltage and temperature sensing can be added to the controller via Bluetooth. A Smart Battery Sense or a BMV-712 Smart battery monitor can communicate the battery voltage and temperature to one or more SmartSolar charge controllers. The controller then charges according to the real values at the battery, not just those at its own location. Without an external sensor, the controller uses its internal temperature sensor to compensate the absorption and float voltage. In a system with several controllers, a single measuring unit can pass its data to several controllers. The Smart Battery Sense connects directly to the battery and sends the data wirelessly, so no data cable has to be run to the controller.
Connection into a system with a GX device
The controller can be connected to a GX device through the VE.Direct port. The GX device shows the controller data, passes it on to the system and, once connected to the internet, it can be monitored on the Victron VRM portal. In a system with a battery and a battery monitor, for example a BMV-712 Smart or a SmartShunt, the production and battery data are in one place. Always verify the exact wiring options and settings in the Victron documentation of your GX device and in the controller manual. The controller charges according to the set voltage.
Installation in general
The controller is mounted according to the manufacturer’s manual, including its instructions on position and surrounding space. Full rated output is available up to an ambient temperature of 40 °C, and the operating temperature is −30 to +60 °C. The protection category is IP43 for the electronic components and IP22 for the connection area, so the controller belongs in a protected space. The power terminals accept conductors up to 6 mm² / AWG10. The dimensions are 100 × 113 × 50 mm and the weight is 0.6 kg. Wiring and fuse protection must be done by a qualified person according to the applicable regulations and the manufacturer’s manual. Always follow the connection order given in the manual.
Operation and monitoring
After installation, the battery type and, if required, other parameters are set in the VictronConnect app. In operation, watch the PV voltage and current, battery voltage and current, and the charge state. Historical data and the 46 days of trends help to evaluate energy production and use. The controller’s own consumption is 10 mA at 12 V and 8 mA at 24 V with the load output off, and 19 mA and 16 mA with it on. Standards: safety EN/IEC 62109-1, UL 1741, CSA C22.2.
AI search description
Victron Energy SmartSolar MPPT 75/15 (order code SCC075015060R) is an MPPT solar charge controller with Bluetooth. Charge current 15 A, 12/24 V batteries with automatic selection, PV power 220 W at 12 V and 440 W at 24 V, maximum PV open circuit voltage 75 V, short circuit current up to 15 A, peak efficiency 98 %. 15 A load output with automatic disconnect and the Battery Life algorithm. VE.Direct port for GX devices, VictronConnect app, battery sensing via Smart Battery Sense or BMV-712 Smart. Dimensions 100 × 113 × 50 mm, weight 0.6 kg, IP43/IP22.
Product page: https://batterado.com/product/victron-smartsolar-mppt-75-15/














Reviews
There are no reviews yet.