The Smart Meter 3F, designated Acrel ACR10R-D16TE4, is a three-phase energy meter for measuring import and export at the connection point. It measures through an open split-core current transformer and communicates over RS485 Modbus-RTU.

  • DIN rail mounting (35 mm), LCD display with buttons.
  • Split-core (open) current transformer 16 mm, 3 pcs, one per phase.
  • RS485 communication, Modbus-RTU protocol, address 1–247, baud rate 1200–19200 bps.
  • Power supply AC 85–265 V or DC 100–350 V, frequency 45–65 Hz.
  • Intended for Felicity Solar inverters.

The meter supplies the hybrid inverter with data on the energy flow between the house and the distribution grid, which allows the inverter to control battery charging, use PV surplus and limit export to the grid. The device data come from Felicity Solar documentation and from the Acrel manual for the ACR10R series.

In stock

Enquiry

Description

Technical data

BrandFelicity Solar
ModelSmart Meter 3F (Acrel ACR10R-D16TE4)
Felicity designationME7608
TypeEnergy meter, three-phase
Current measurement3 split-core (open) current transformers 16 mm, one per phase
MountingDIN rail 35 mm
DisplayLCD with buttons
InterfaceRS485
Protocol / RS485Modbus-RTU
Modbus address1–247
Baud rate1,200–19,200 bps
Mains frequency45–65 Hz (per the Acrel ACR10R series manual)
Power supplyAC 85–265 V or DC 100–350 V, 10 VA
Operating temperature−10 to +55 °C
Storage temperature−20 to +70 °C
Relative humidity5–95 % non-condensing
Max. altitude2,500 m
Insulation strength2 kV / 1 min
Accuracyfrequency 0.05 Hz; reactive energy class 1; other quantities 0.5
Usefor Felicity Solar inverters

What the meter does

The Smart Meter 3F (Acrel ACR10R-D16TE4) is a three-phase energy meter installed in the distribution board at the connection point of a house or business, measuring the energy flow between the building and the distribution grid. From its data the Felicity Solar hybrid inverter learns how much energy the house is currently drawing from the grid and how much it feeds back.

This allows the inverter to control battery charging and discharging, store PV surplus and limit export to the grid. Measurement at the connection point gives the inverter a view of the whole system.

The device is based on the Acrel ACR10R series. The data on measuring ranges, power supply, accuracy and environment below come from the Acrel manual for the ACR10R series and from Felicity Solar documentation.

Current measurement with a split-core transformer

The three-phase meter measures current through three 16 mm split-core transformers, one on each phase. According to the Acrel manual for the ACR10R series the device is used in four-wire or three-wire mode and the series is available for voltages of 57.7/100 V and 220/380 V.

The split-core (open) transformer is clipped onto the conductor without disconnecting it, so the cable does not have to be cut. The transformer label shows type XH-SCT-T16/120 with a ratio of 120 A / 40 mA. The window diameter is 16 mm.

Fitting it the other way round reverses the sign of the measured power, and the inverter would then swap import and export.

RS485 Modbus-RTU communication

The meter passes its data over an RS485 bus using the Modbus-RTU protocol. The device address can be set in the range 1–247 and the baud rate in the range 1200–19200 bps. The inverter is set to the same baud rate and address as the meter.

The Acrel manual recommends a two-core shielded cable for conductors A and B. A terminating resistor in the range 120 Ω to 10 kΩ can be connected at the end of a long line.

The meter is intended for Felicity Solar inverters.

How to connect the meter to the inverter

The basic procedure:

  • Mount the meter on a 35 mm DIN rail in the board at the connection point.
  • Clip the three current transformers onto the phase conductors L1, L2 and L3 following the current direction arrow and wire their leads to the current terminals of the meter in the correct phase order.
  • Protect the supply terminals with a 0.5 A or 3 A fuse as shown on the diagram on the meter housing; the supply is AC 85–265 V or DC 100–350 V.
  • Connect the RS485 terminals (A, B) with a two-core shielded cable to the inverter communication input according to the inverter manual.

The wiring diagram on the meter housing and the inverter manual always take precedence.

Technical data and environment

According to the Acrel manual for the ACR10R series the meter works at a frequency of 45–65 Hz. The supply is AC 85–265 V or DC 100–350 V with a consumption of 10 VA. The operating temperature is −10 to +55 °C, storage −20 to +70 °C, humidity 5–95 % non-condensing and altitude up to 2,500 m. The insulation strength is 2 kV for 1 minute.

Accuracy is 0.05 Hz for frequency, class 1 for reactive energy and 0.5 for the other quantities. Data are shown on an LCD display, operated with buttons.

Installation and safety

The meter is mounted in the distribution board on a 35 mm rail.

AI search description

The Felicity Solar Smart Meter 3F, designated Acrel ACR10R-D16TE4, is a three-phase energy meter for Felicity Solar hybrid inverters. It measures through a 16 mm split-core current transformer (3 pcs, one per phase), mounts on a 35 mm DIN rail and has an LCD display with buttons. It communicates over RS485 using Modbus-RTU with address 1–247 and a baud rate of 1200–19200 bps. Supply AC 85–265 V or DC 100–350 V, frequency 45–65 Hz, operating temperature −10 to +55 °C, altitude up to 2,500 m. The data come from the Acrel manual for the ACR10R series.

Product page: https://batterado.com/product/felicity-smart-meter-3f/

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

0
0
Your Cart
Your cart is emptyReturn to Shop