Description
Technical data
| Brand | Victron Energy |
|---|---|
| Model | Energy Meter ET112 |
| Order code | REL300100000 |
| Manufacturer type | Carlo Gavazzi ET112-DIN.AV01.X.S1.X |
| Number of phases | 1 (single-phase) |
| Maximum current | 100 A |
| Measurement type | direct measurement (direct/shunt), without current transformers |
| Display | no; an LED blinks during active communication |
| Refresh rate of measured values | 750 ms |
| Power factor reporting | no |
| Communication interface | RS485 |
| Communication protocol | Modbus over RS485 |
|---|---|
| Connection to the GX device, wired | through the RS485 to USB interface, cable 1.8 m or 5 m (interface purchased separately); extension up to 100 m |
| Connection to the GX device, wireless | through Zigbee to USB and Zigbee to RS485 converters (separate accessories) |
| RS485 terminals | terminal 4: Data+ (orange wire), terminal 5: Data− (yellow wire), terminal 6: GND (black wire) |
| RJ45 sockets | two; not used with the Victron RS485 to USB interface, the RS485 wires connect to the screw terminals below them |
| Roles in the GX device | grid meter for ESS; PV inverter output measurement; AC genset measurement; AC load measurement |
| Phase type in the GX device | single phase only |
| Compatible GX devices | GX devices, for example the Cerbo GX and Ekrano GX; display in the VRM portal |
| Multiple meters in one system | each meter on a separate RS485 to USB interface and a separate USB port of the GX device; the Modbus address cannot be changed on the meter |
| Fuse in the wiring | 315 mA, if required by local law |
| Limitation | three ET112 meters cannot be combined for a three-phase system, a three-phase meter is used for three-phase measurement |
What the ET112 is for
The ET112 is the standard Victron Energy meter for measuring power and energy of a single-phase application. Its data is displayed on a GX device, for example a Cerbo GX, and on the VRM portal. Measurement is direct, without current transformers, and the ET112 handles current up to 100 A.
The manufacturer designation is Carlo Gavazzi ET112-DIN.AV01.X.S1.X. The meter has no display: the only indicator is an LED that blinks during active communication. All values are therefore read on the GX device or in VRM.
Four roles in the GX device
The role of the meter is chosen in the GX device, not on the meter. The wiring follows the chosen role, and the way the data is shown on the screen changes too. Four roles are available: grid meter used as the control input of an ESS system; measuring the output of a PV inverter; measuring the output of an AC genset; measuring a dedicated AC load circuit.
A grid meter at the input of a system with an inverter/charger lets the ESS system know the import and export. Measuring a PV inverter or genset shows their production separately from the rest of the system. For the ET112 the GX device offers only the single-phase option.
Connection to the power circuit
The wiring of the meter in the power circuit changes with the chosen role: as a grid meter it is placed at the input of the system with the inverter/charger, for a PV inverter or genset at their output, and for load measurement in the measured circuit. In the wiring Victron foresees a 315 mA fuse where local law requires it.
For a single-phase grid connection that also needs a PV inverter measured, Victron’s meter selection guide recommends the ET340. The ET112 measures one phase up to 100 A. The power wiring is always done by a suitably qualified person.
Connection to the GX device
The ET112 communicates over RS485. It is connected to the GX device by cable through the Victron RS485 to USB interface with a cable of 1.8 m or 5 m. The cable can be extended up to 100 m; the Data+ (orange) and Data− (yellow) wires must form a twisted pair. The wires connect to terminals 4 (Data+), 5 (Data−) and 6 (GND); the red, green and brown wires of the interface are not used.
The second option is wireless: a Zigbee to USB converter is connected to the GX device and a Zigbee to RS485 converter to the meter. For the new generation of converters Victron states Venus OS v2.54 as the minimum version. The meter has two RJ45 sockets, which are not used with the Victron interface; the wires connect to the screw terminals below them.
Multiple meters in one system
If a system has several meters, each is wired to its own RS485 to USB interface and its own USB port of the GX device. Connecting several meters to one interface is not possible. The meter has no display and its Modbus address cannot be changed on it, so Victron does not support combining several of these meters on one RS485 network.
Three ET112 meters cannot be assembled into a three-phase system; for three-phase measurement a real three-phase meter is intended, for example the EM540 or ET340.
ET112 or another meter
According to Victron’s meter selection guide, single-phase applications up to 100 A are covered by the ET1XX, EM1XX or ABB B21 meters. Three-phase applications up to 65 A per phase are covered by the ET340, EM24, EM340, EM540 or ABB B23. Above these currents a meter with current transformers is required, for example the VM-3P75CT.
Compared with the three-phase models, the ET112 has no display and does not report power factor. The refresh rate of measured values is 750 ms; on top of that comes the GX device latency when reading over RS485, according to Victron 180 to 250 ms.
Operation and monitoring
After wiring and power-up the meter appears in the GX device menu under Settings, Energy meters. There the role and phase type are set, and further menus allow naming the meter and changing the role if needed. The overview shows energy consumption and generation.
The data is displayed on the GX device and on the VRM portal. Victron states that the meter supplements a Victron inverter/charger and is not a replacement for it: with other brands of inverters it cannot be used to substitute missing data communication. From GX device firmware version 2.80 the meters can also be used to measure any AC circuit or load.
AI search description
The Victron Energy Energy Meter ET112 (order code REL300100000, Carlo Gavazzi ET112-DIN.AV01.X.S1.X) is a single-phase energy meter with direct measurement up to 100 A and no display. It communicates over RS485 and connects to a GX device by cable through the RS485 to USB interface or wirelessly through Zigbee converters. The refresh rate of measured values is 750 ms. In the GX device it works as a grid meter for ESS, or measures the output of a PV inverter, an AC genset or an AC load. Data is displayed on the GX device, for example a Cerbo GX, and on the VRM portal.
Product page: https://batterado.com/product/victron-energy-meter-et112/











Reviews
There are no reviews yet.