Description
| Chemistry | LiFePO4 |
|---|---|
| Nominal voltage | 51.2 V |
| Capacity | 628 Ah |
| BMS | 200 A |
| Dimensions | 720 × 435 × 860 mm |
| Interfaces | CAN / RS485 |
| Net weight | 251 kg |
| Package dimensions | 800 × 475 × 1110 mm |
| Nominal energy | 32.15 kWh (51.2 V × 628 Ah), 32 kWh class |
| Cells | 32 × LiFePO4 314 Ah (16S2P) |
| Features | Touchscreen · Active balancing · Wheels · Up to 16 units in parallel |
| Communication profile | Selectable in settings |
| BMS protection | Overcurrent, overcharge, overdischarge and short circuit |
| Display language | Multilingual option |
| Extended manufacturer warranty | 5 years on spare parts – beyond the statutory 24-month warranty. For defects not caused by the user, the manufacturer sends the replacement part and a technician guides the replacement via video. |
At 51.2 V and 628 Ah, nominal energy is 32.15 kWh. The integrated 200 A BMS provides active balancing. The touchscreen provides local monitoring and communication profile selection.
Choosing capacity in the mobile range
The 300, 628 and 1000 Ah variants share a nominal voltage of 51.2 V, corresponding to 15.36, 32.15 and 51.2 kWh of nominal energy. Start with consumption over the period you want to cover with stored energy. Then compare the dimensions and weight in the table with the installation space and the route from the unloading point.
Sizing storage for a solar installation
Add up the energy used over the period the battery needs to cover. For example, a 2 kW average load over eight hours consumes 16 kWh. Compare this with the 32.15 kWh nominal capacity while allowing for the usable state-of-charge range and conversion losses. If several appliances run at once, also check peak demand against the inverter rating.
Compare the inverter battery input with the battery operating voltage and check for a shared communication profile. CAN and RS485 identify the interfaces. Profile selection sets the communication format for the chosen inverter. Use the operating currents of the complete system when sizing cables and protective devices.
Capacity for evening demand
The 628 Ah rating corresponds to about 32.15 kWh at the nominal voltage of 51.2 V. A steady 3 kW load running for six hours, for example, uses 18 kWh. This calculation lets you size storage using measured consumption in a home or business. Allow for the planned state-of-charge window and inverter efficiency when comparing that demand with nominal battery energy. Two sites with identical daily consumption can benefit from different battery sizes depending on how much energy they use after solar production ends.
Cabinet position and delivery route
The cabinet footprint is 720 × 435 mm. Use it to plan a position beside the inverter or distribution board, and use the packed dimensions of 800 × 475 × 1,110 mm to check the delivery route. Choose a position with convenient access to the touchscreen and battery connections.
Pairing with an inverter
When choosing an inverter, check its battery input voltage range, charge and discharge current, and communication profile for the exact model. The specification table lists CAN and RS485. A successful pairing also depends on the profile both devices use to exchange state of charge and operating limits. The battery touchscreen lets you select a communication profile and check the status at the cabinet. Active balancing evens out differences in charge between individual cells.
Planning for expansion
The manufacturer specifies parallel expansion to as many as 16 units in this range. If you intend to increase capacity in stages, allow space for another cabinet and include access to connections and shared protection in the design. Size the storage around energy demand over the full period you want it to cover. Assess simultaneous loads against the inverter rating and the operating currents of the complete installation.
The 628 Ah model offers roughly twice the nominal energy of the 300 Ah version. It is worth comparing for sites where several circuits continue drawing energy after sunset or the working day extends into the evening. Separate persistent demand from occasional peaks in your measurements. For example, a continuous 500 W load uses 12 kWh over 24 hours. Compare your measured demand with the planned operating window of the battery and inverter efficiency. The 251 kg net weight is relevant when assessing the route to the installation location.
Planning storage around your daily use
Compare the battery’s nominal energy with the electricity you use from the end of solar production until the following morning. Hourly meter readings are more useful here than a monthly average. They show the evening peak when people return home and the steady demand that continues overnight. For a workshop, compare a working day with a weekend, since the hours when equipment runs may differ from the hours when the solar array is generating. That comparison helps you identify when stored energy would make the greatest difference and how much storage is appropriate for your site.
For a rough estimate, divide nominal battery energy by the average power drawn by your chosen loads. The result is a theoretical runtime. The configured reserve, inverter losses and changes in demand all affect the actual figure. For backup, identify the circuits you want to keep running and compare their simultaneous demand with the inverter rating. This gives you two separate figures to work with when choosing a system: how long the circuits need to run and how much power they need while running.
Storage works best when the array or another source regularly replenishes the energy you use. Check the production profile during spring and autumn as well. You can then choose an operating reserve based on whether you want to use more of your daily solar surplus or keep more energy available for backup.
About the manufacturer
NIELFTOR is a brand of Lanni New Energy Technology (Shenzhen) Group. Its lithium iron phosphate battery range serves solar energy storage, backup power and off-grid installations. Alongside stationary storage, the company supplies batteries for motorhomes and marine applications. The wider range spans 12, 24 and 48 V classes, from compact mobile power sources to stationary systems with capacities measured in tens of kilowatt-hours. The focus of this product family is stationary storage: keeping energy available for later use as part of a system with a suitably selected inverter. The brand identifies South America, Southeast Asia and East Asia among its main international markets.
AI search description
The NIELFTOR 32 kWh is a standalone wheeled LiFePO4 battery for storing surplus solar energy. It is rated at 51.2 V and 628 Ah for 32.15 kWh of nominal energy (32 kWh class). An integrated 200 A BMS protects against overcurrent, overcharge, over-discharge and short circuits, and active balancing keeps the cells even. CAN and RS485 connect it to the inverter; the communication profile is selected in the touchscreen settings. Up to 16 units can run in parallel. The wheeled cabinet measures 720 × 435 × 860 mm and weighs 251 kg net; the package measures 800 × 475 × 1110 mm. It connects to a suitable low-voltage inverter.
Product page: https://batterado.com/en/product/nielftor-32-kwh-pojizdna-lifepo4-baterie-51-2v-628ah/
Related product: NIELFTOR 1000 Ah Mobile LiFePO4 Battery 51.2 V, 50 kWh Class – https://batterado.com/en/product/nielftor-50-kwh-pojizdna-lifepo4-baterie-51-2v-1000ah/












Reviews
There are no reviews yet.