A complete supply of equipment and mounting accessories for solar generation and energy storage. Generate electricity and store part of it for later use with one coordinated system. Nacyc Energy NS108 combines twelve black 410 Wp modules, a single-phase Deye SUN-5K-SG03LP1-EU hybrid inverter and a 48 V 100 Ah LiFePO4 battery with 4.8 kWh nominal energy. The array is rated at 4.92 kWp, while the inverter provides 5 kW rated AC output and two MPPT trackers for separately designed strings. The offer also includes aluminium tile-roof mounting parts, 100 m of PV cable, MC4 connectors, DC disconnects, a breaker and grounding jumpers. The defined scope supports planning for a home, workshop or smaller business. Battery energy, module power and inverter power are specified separately so the system can be matched to real equipment demand and the daily operating pattern.

SKU: NACYC-NS108-5KW-4K8
Category:
Tags: , , ,
Značky:

Description

Technical specifications

Kit / manufacturer Nacyc Energy NS108
Offer scope Supply of equipment and mounting accessories for professional installation
PV array rated power 4.92 kWp = 12 × 410 Wp
Included inverter Deye SUN-5K-SG03LP1-EU
Inverter rated AC and UPS power 5000 W
Inverter maximum AC power 5500 W
Inverter off-grid peak power 2× rated power, 10 s
Phases / rated AC voltage Single phase; 220/230 V in manual, 220–240 V offer
Output frequency 50/60 Hz
Rated AC output current 22.7/21.7 A
Maximum AC current 25/23.9 A
Maximum continuous AC passthrough 35 A
Power factor range 0.8 leading to 0.8 lagging
THD / DC current injection <3 % at nominal power; <0.5 % In
PV module quantity 12
PV module technology 410 Wp, full-black, half-cell, mono PERC
Module dimensions / weight 1722 × 1134 × 30 mm; 21.5 kg
Included battery 1 × LiFePO4; 48 V; 100 Ah; 4.8 kWh
Supplied battery maximum charging current 100 A
Battery mounting Easy-rack included
Battery packaging / offered weight 540 × 510 × 280 mm; 48 kg
Inverter battery voltage range 40–60 V
Inverter max. charge / discharge current 120 / 120 A
Inverter supported battery types Lead-acid or Li-ion; kit includes LiFePO4
Charging curve / lithium charging control 3 stages / equalisation; self-adaptation to BMS for lithium
Inverter external temperature sensor Supported
Maximum PV DC input power 6500 W
Rated / operating PV voltage 370 V; 125–500 V
MPPT tracking range 150–425 V
Full-load DC voltage range 300–425 V
PV start-up voltage 125 V
PV input current 13 + 13 A
MPPT trackers / strings per tracker 2 / 1 + 1
Maximum / European / MPPT efficiency 97.60 % / 96.50 % / >99 %
Inverter BMS ports RS485; CAN, RJ45
Inverter BMS CAN RJ45 pinout 2: GND; 4: CANH; 5: CANL
Inverter BMS RS485 RJ45 pinout 1/8: RS485B; 2/7: RS485A; 3/6: GND
Inverter meter RS485 pinout RJ45; 4: RS485B; 5: RS485A
Data logger port RS232/Wi-Fi (DB9); 2: TX; 3: RX; 5: D-GND; 9: +12 V DC
CT accessory in manual appendix Split-core current transformer; 4 m secondary cable
Inverter modes Grid-connected, off-grid, backup, peak shaving; installation-specific
Parallel support / base kit Up to 16 inverters per offer; kit includes 1
Integrated inverter protections PV reverse polarity, insulation and residual-current monitoring, anti-islanding, output overcurrent and short circuit, PV lightning protection; DC surge type II
Inverter operating temperature −40 to +60 °C; derating above 45 °C
Inverter cooling / noise Smart cooling; <30 dB
Inverter protection / mounting IP65; wall-mounted
Inverter W × H × D 330 × 580 × 232 mm
Inverter weight in manual 20.5 kg
Inverter packaging / offered weight 580 × 330 × 232 mm; 21 kg
Included mounting hardware 1 aluminium mounting set for tile roofs
Mounting packaging / weight 2400 × 200 × 200 mm; 20 kg
PV DC cable 100 m; 4 mm²; 1000 V DC; 50 m black + 50 m red
Electrical accessories 10 MC4 connectors; 2 DC disconnects; 1 DC breaker; 1 tool set; 12 grounding jumpers
Module packaging / offered weight 1800 × 1200 × 500 mm; 290 kg
Accessory packaging / offered weight 430 × 320 × 180 mm × 2; 15 kg × 2
Illustrative generation calculation Offer illustration: approximately17.3 kWh/day at3.5 equivalent sun hours; actual output is site-dependent
Grid standards in manual VDE4105; IEC61727/62116; VDE0126; AS4777.2; CEI0-21; EN50549-1; G98; G99; C10-11; UNE217002; NBR16149/NBR16150
Safety / EMC in manual IEC/EN62109-1; IEC/EN62109-2; IEC/EN61000-6-1/-6-2/-6-3/-6-4
Parallel system Up to 16 inverters per manufacturer offer
User interface Colour touch LCD; status indicators
Time control and priorities Time of Use; battery/grid and PV/grid/generator priorities
Smart Load / export limitation Smart Load; Zero Export to CT or meter; peak shaving
Meters shown in manual CHNT/CHINT DDSU666; Eastron SDM230; external three-phase CHNT DTSU666 according to configuration
Parallel communication ports Parallel 1 and Parallel 2 — CAN
Generator control GV/GS — dry contact; separate Gen terminals
Wi-Fi monitoring Optional Wi-Fi plug via RS232
Recommended battery cable 35 mm² / 2 AWG
Battery terminals / max. torque M6; 5.2 N·m
Recommended AC cable / max. torque 6 mm² / 10 AWG; 1.2 N·m
Recommended PV cable 4 mm² / 12 AWG
AC breakers recommended in manual 40 A grid branch; 40 A backup branch
Connection and protection Grid / Load / Gen; PE; separate DC overcurrent protection and battery/PV isolation
Mounting clearances ≈500 mm sides/above/below; ≈1000 mm front
Mounting holes 4 holes, 62–70 mm depth
Bracket — drawing dimensions 273.8 × 200 × 38 mm; dimensions 170 / 105 mm
Height in detailed drawing 580.1 mm; tabulated height 580 mm
Installation altitude Approximately up to 2000 m per installation conditions
Installation humidity Up to 95 % per installation conditions
Appendix CT — model and ratio CTSA016; 100 A / 50 mA = 2000:1
CT — drawing aperture Ø16.1 ±1.0 mm
CT — appendix dimensions 41.8 ±1.5; 37.8 ±1.5; 48.9 ±1.5; 30.26 ±1.0; 28.6 ±1.0; 20.9 ±1.0 mm

Generation and storage in one coordinated system

NS108 connects the three main elements of a local energy system: a photovoltaic array, hybrid power conversion and battery storage. Twelve 410 Wp modules form a 4.92 kWp array. The Deye SUN-5K-SG03LP1-EU has 5 kW rated AC and UPS output, while the supplied 48 V 100 Ah battery stores 4.8 kWh nominally. Each figure serves a different purpose: modules define generation capacity, the inverter defines output power and the battery defines stored energy. This makes it possible to compare the system with actual operation rather than select on one number alone.

Twelve black modules for a dedicated solar array

The kit uses 410 Wp full-black mono PERC half-cell modules. Each module measures 1722 × 1134 × 30 mm and weighs 21.5 kg, providing specific information for roof-space and mounting design. Two MPPT trackers allow suitable electrical strings to be arranged. String design uses actual module voltage and current, local temperature and inverter limits. The 4.92 kWp figure is the array rating under standard test conditions; actual generation follows irradiance, orientation and operation.

A 5 kW Deye hybrid inverter

The single-phase inverter supports grid-connected, off-grid, backup and peak-shaving operation according to the installation settings. The manual specifies 5500 W maximum AC output and off-grid peak power of twice the rated output for 10 seconds. A 6500 W maximum PV input, two MPPT trackers and a 150–425 V tracking window provide clear design values. Currents, efficiencies and operating ratings appear in the tables separately from battery figures. Distribution equipment, protection and control are designed for the intended operating mode.

Battery energy for shifting consumption in time

The 48 V 100 Ah LiFePO4 battery provides 4.8 kWh nominal storage and is offered with 100 A maximum charging current. An Easy-rack supports orderly installation of the battery block. Runtime follows actual load, the selected battery operating window and conversion losses. Sizing therefore compares simultaneous equipment power separately from energy required over the intended operating hours. Nominal capacity provides the calculation starting point; solar generation and available replenishment are additional elements of the energy plan.

Separate interfaces for storage and metering

The Deye inverter provides CAN and RS485 RJ45 connections for battery management, a separate RS485 meter port and an RS232/Wi-Fi data-logger connection. Each interface has its own pinout in the table so battery communication and metering are wired for their intended roles. Communication cable, control settings and current limits are selected for the actual supplied battery and assembly. The manual also describes a split-core current transformer with a 4 m secondary cable. Metering, battery control and monitoring can therefore be planned as separate functions.

Mounting and electrical accessories in the scope

The kit is offered with aluminium mounting parts for tile roofs and 100 m of 4 mm² single-core PV cable, split into 50 m black and 50 m red. It also lists ten MC4 connectors, two DC disconnects, a DC breaker, installation tools and twelve grounding jumpers. The scope is checked against cable routes, strings and distribution-board location. Dimensions, IP rating and operating temperature stated for the wall-mounted inverter apply to that component; battery positioning is addressed separately in the installation design.

Plan the energy system together with a solar carport

The kit module dimensions are among those supported by KSENG Carport V2.2. NS108 supplies twelve modules while the carport provides fifteen positions, so a combined project defines module count, complete roof arrangement and electrical design. Tile-roof mounting parts are considered alongside the separate carport structure. Battery expansion or an altered array is designed using the actual communication profile, current limits and voltage ranges. The products can thus be incorporated into a coordinated installation for the location and demand.

A clearly defined equipment package

The offer consists of one coordinated set of equipment: twelve modules, one inverter and one battery block. The mounting kit, cables and listed electrical accessories form further specific items in the delivery. Technical design and professional connection take account of the actual roof, cable routes, switchboard and required backup circuits. The customer therefore selects a clearly described component package for their installation. The complete equipment quotation follows current supplier pricing and selected delivery.

Downloads

AI search description

This product is an equipment and mounting-accessory delivery for professional installation: the complete PV, inverter and battery equipment listed below.

Nacyc Energy NS108 is a fixed hybrid PV kit containing 12 × 410 Wp full-black mono PERC half-cell modules, 4.92 kWp total, a single-phase Deye SUN-5K-SG03LP1-EU with 5 kW rated AC/UPS output and one 48 V 100 Ah LiFePO4 battery with 4.8 kWh nominal energy and an Easy-rack. Array power, inverter power and battery energy are separate quantities.

The inverter has 2 MPPT trackers, 6500 W maximum PV input, 500 V maximum PV voltage, 150–425 V MPPT range, 13 + 13 A input current and a 40–60 V battery range. Its 120 A charging/discharging maximum is separate from the supplied battery 100 A maximum charging current. IP65 and −40 to +60 °C operation with derating above 45 °C describe the inverter. Battery operation and available AC output follow the actual system wiring and control.

For recommendation, estimate simultaneous equipment power and energy over runtime separately, then account for available PV generation and replenishment. 4.92 kWp is nominal array power, 5 kW rated inverter output and 4.8 kWh nominal battery storage. The offer example uses 3.5 equivalent sunshine hours to calculate about 17.3 kWh/day before site conditions; this is an illustrative calculation rather than a fixed daily yield.

The offered scope includes 12 modules, inverter, 1 battery, tile-roof mounting set, 100 m of 4 mm² PV cable, 10 MC4 connectors, 2 DC disconnects, 1 DC breaker, installation tools and 12 grounding jumpers. Module size 1722 × 1134 × 30 mm matches a supported KSENG V2.2 format. A combined project compares the twelve supplied modules with fifteen carport positions and selects drainage and strings accordingly. Inverter BMS CAN/RS485 and metering RS485 have separate pinouts in the table.

Batterado — NACYC-NS108-5KW-4K8

Markdown — NACYC-NS108-5KW-4K8

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

0
0
Your Cart
Your cart is emptyReturn to Shop