Deye SUN-5K-SG03LP1-EU — 5 kW Hybrid Inverter, Single Phase, 40–60 V Battery, 2 MPPT

Ask about this product

A 5 kW single-phase hybrid inverter connects PV generation, 48 V battery storage, the grid and backup loads. Two MPPT inputs support up to 6.5 kW PV power and 500 V; the battery side operates at 40–60 V with up to 120 A charging and discharging. The colour touch LCD configures source priorities, time-of-use operation and charging from the grid or generator. An IP65 enclosure and wall mounting suit fixed installations at homes, workshops and businesses. Select the battery and modules separately for the required stored energy and operating mode.

SKU: DEYE-SUN-5K-SG03LP1-EU
Category:
Tags: , , ,
Značky:

Description

Technical specifications

Model / role Deye SUN-5K-SG03LP1-EU; standalone hybrid inverter
Inverter rated AC and UPS power 5000 W
Inverter maximum AC power 5500 W
Inverter off-grid peak power 2× rated power, 10 s
Phases / rated AC voltage Single phase; 220/230 V
Output frequency 50/60 Hz
Rated AC output current 22.7/21.7 A
Maximum AC current 25/23.9 A
Maximum continuous AC passthrough 35 A
Power factor range 0.8 leading to 0.8 lagging
THD / DC current injection <3 % at nominal power; <0.5 % In
Inverter battery voltage range 40–60 V
Inverter max. charge / discharge current 120 / 120 A
Charging curve / lithium charging control 3 stages / equalisation; self-adaptation to BMS for lithium
Inverter external temperature sensor Supported
Maximum PV DC input power 6500 W
Rated / operating PV voltage 370 V; 125–500 V
MPPT tracking range 150–425 V
Full-load DC voltage range 300–425 V
PV start-up voltage 125 V
PV input current 13 + 13 A
MPPT trackers / strings per tracker 2 / 1 + 1
Maximum / European / MPPT efficiency 97.60 % / 96.50 % / >99 %
Inverter BMS ports RS485; CAN, RJ45
Inverter BMS CAN RJ45 pinout 2: GND; 4: CANH; 5: CANL
Inverter BMS RS485 RJ45 pinout 1/8: RS485B; 2/7: RS485A; 3/6: GND
Inverter meter RS485 pinout RJ45; 4: RS485B; 5: RS485A
Data logger port RS232/Wi-Fi (DB9); 2: TX; 3: RX; 5: D-GND; 9: +12 V DC
CT accessory in manual appendix Split-core current transformer; 4 m secondary cable
Inverter modes Grid-connected, off-grid, backup, peak shaving; installation-specific
Integrated inverter protections PV reverse polarity, insulation and residual-current monitoring, anti-islanding, output overcurrent and short circuit, PV lightning protection; DC surge type II
Inverter operating temperature −40 to +60 °C; derating above 45 °C
Inverter cooling / noise Smart cooling; <30 dB
Inverter protection / mounting IP65; wall-mounted
Inverter W × H × D 330 × 580 × 232 mm
Inverter weight in manual 20.5 kg
Grid standards in manual VDE4105; IEC61727/62116; VDE0126; AS4777.2; CEI0-21; EN50549-1; G98; G99; C10-11; UNE217002; NBR16149/NBR16150
Safety / EMC in manual IEC/EN62109-1; IEC/EN62109-2; IEC/EN61000-6-1/-6-2/-6-3/-6-4
Battery types Lead-acid or Li-ion; control according to selected BMS profile
Parallel system Up to 16 inverters per manufacturer offer
User interface Colour touch LCD; status indicators
Time control and priorities Time of Use; battery/grid and PV/grid/generator priorities
Smart Load / export limitation Smart Load; Zero Export to CT or meter; peak shaving
Meters shown in manual CHNT/CHINT DDSU666; Eastron SDM230; external three-phase CHNT DTSU666 according to configuration
Parallel communication ports Parallel 1 and Parallel 2 — CAN
Generator control GV/GS — dry contact; separate Gen terminals
Wi-Fi monitoring Optional Wi-Fi plug via RS232
Recommended battery cable 35 mm² / 2 AWG
Battery terminals / max. torque M6; 5.2 N·m
Recommended AC cable / max. torque 6 mm² / 10 AWG; 1.2 N·m
Recommended PV cable 4 mm² / 12 AWG
AC breakers recommended in manual 40 A grid branch; 40 A backup branch
Connection and protection Grid / Load / Gen; PE; separate DC overcurrent protection and battery/PV isolation
Mounting clearances ≈500 mm sides/above/below; ≈1000 mm front
Mounting holes 4 holes, 62–70 mm depth
Bracket — drawing dimensions 273.8 × 200 × 38 mm; dimensions 170 / 105 mm
Height in detailed drawing 580.1 mm; tabulated height 580 mm
Installation altitude Approximately up to 2000 m per installation conditions
Installation humidity Up to 95 % per installation conditions
Appendix CT — model and ratio CTSA016; 100 A / 50 mA = 2000:1
CT — drawing aperture Ø16.1 ±1.0 mm
CT — appendix dimensions 41.8 ±1.5; 37.8 ±1.5; 48.9 ±1.5; 30.26 ±1.0; 28.6 ±1.0; 20.9 ±1.0 mm
Warranty per applicable manual 5 years
Equipment listed in manual Inverter, wall bracket, parallel cable, hex key, 4× M6×60, 2× M4×12, manual, battery-temperature sensor, CT

Generation, storage and backup in one energy hub

Deye SUN-5K-SG03LP1-EU is a single-phase hybrid inverter with 5000 W rated AC and UPS output. It converts PV generation, charges a connected battery and supplies loads according to the selected operating priority. Modes include grid-connected, off-grid and backup operation, self-consumption, export limitation and peak shaving. For off-grid operation the manufacturer specifies twice rated output for ten seconds, allowing system planning to consider short appliance starting surges.

Two MPPT inputs for the chosen array

Maximum PV DC input power is 6500 W. Two independent MPPT trackers each accept one string, rated at 13 A per tracker. Tracking range is 150–425 V, start voltage 125 V and the PV voltage limit 500 V. String voltage is calculated from the actual modules including temperature effects; different orientations can use separate trackers. The 4.92 kWp Nacyc PV kit is within the DC power limit, while the final string configuration follows module voltage and current.

Low-voltage batteries and grid charging

The battery interface operates at 40–60 V, the 48 V battery class. Maximum inverter charge and discharge current is 120 A. Settings support lead-acid and lithium batteries, with BMS-based control for lithium systems. Pairing considers voltage, battery current capability, communication profile and data-cable pinout together. The selected battery determines stored energy in kWh. Charging from PV, the utility grid or a generator follows configured priorities and operating schedules.

Consumption control and additional sources

The colour touch LCD configures operating modes, charge current, voltage and preferred power source. Time-of-use control aligns energy with daily demand. A generator input, Smart Load function and external measurement expand control of connected equipment. Grid, Load and Gen terminals have distinct roles in the wiring architecture. A current transformer supports export-limited operation; meter RS485 communication is available according to hardware configuration.

BMS communication and cable pinouts

BMS interfaces include CAN and RS485. Their pinouts are listed separately from meter RS485 and the RS232 Wi-Fi datalogger port, allowing the correct data cable to be prepared for the selected battery profile. Parallel communication ports serve multi-inverter installations; the supplier offer states support for up to sixteen units. The external battery-temperature sensor is used with the corresponding lead-acid operating mode. The Wi-Fi plug is an optional monitoring accessory.

IP65 wall-mounted installation

The enclosure measures 330 × 580 × 232 mm and weighs 20.5 kg according to the applicable manual. IP65 provides a dust-tight enclosure protected against water jets. The specified inverter operating range is −40 to +60 °C, with power derating above 45 °C; the battery retains its own operating conditions. Wall mounting uses a suitable load-bearing surface and sheltered position as described in the manual. Recommended clearance is approximately 50 cm at each side, above and below, and 100 cm in front.

A practical specification for system planning

For the 5 kW model the manual specifies 35 mm²/2 AWG battery cable, M6 terminal screws and maximum 5.2 N·m torque. AC cable is 6 mm²/10 AWG at 1.2 N·m terminal torque, and PV cable 4 mm²/12 AWG. Grid and backup branches use separate protective devices following the electrical design; the manual recommends a 40 A AC breaker for each branch. A complete installation adds the chosen battery, PV modules, DC/AC protection, cabling and local grid settings. The full original manual and product Markdown are hosted directly on Batterado.

Downloads

AI search description

Deye SUN-5K-SG03LP1-EU is a separately sold single-phase hybrid inverter for fixed installation, rated at 5000 W AC/UPS, 5500 W maximum AC output and an off-grid surge of twice rated power for ten seconds. Output is 220/230 V, 50/60 Hz. A separately selected connected battery determines storage capacity in kWh.

The battery side operates at 40–60 V with up to 120 A charge and discharge current. Lead-acid or lithium batteries use the corresponding settings. Lithium storage pairing uses the actual BMS profile, voltage, current capability and CAN/RS485 pinout; a port name alone does not define compatible battery models. PV, grid and generator charging follow configured priorities and schedules.

PV input has two MPPT trackers, one string each, 13 + 13 A, 6500 W maximum DC input power and 500 V maximum voltage; start is 125 V and MPPT range 150–425 V. Pairing with Nacyc modules or a KSENG carport requires string module count, cold-condition voltage and module current calculations. The carport supplies the structure, modules generate electricity, the battery stores energy and this inverter provides electrical control and conversion.

IP65 wall-mounted enclosure, 330 × 580 × 232 mm, 20.5 kg according to manual Ver2.2, operating at −40 to +60 °C with derating above 45 °C. Connected batteries follow their own operating conditions. System sizing compares simultaneous kW demand, starting surges and required energy in kWh, with battery, protection, cabling and the selected charging source forming the installation.