Description
Technical specifications
| Manufacturer / model | EVE / LF304 |
|---|---|
| Construction / chemistry | Prismatic aluminium cell / LiFePO4 |
| Single-cell nominal voltage | 3.2 V |
| Single-cell capacity | 304 Ah |
| Single-cell energy | 972.8 Wh |
| 16S — calculated voltage / capacity | 51.2 V / 304 Ah / 15.5648 kWh |
| 4S — calculated voltage / energy | 12.8 V / 3.8912 kWh |
| 8S — calculated voltage / energy | 25.6 V / 7.7824 kWh |
| Pack BMS | External LiFePO4 BMS matched to cell configuration |
| Communication ports | Determined by the selected external BMS |
| Communication protocols and profiles | Determined by the selected external BMS |
| Standard charging / discharging current | 0.5 C / 152 A (25 ± 2 °C) |
| Maximum continuous charging current | 1 C / 304 A (25 ± 2 °C) |
| Maximum continuous discharging current | 1 C / 304 A (25 ± 2 °C) |
| Pulse discharging current | 3 C / 912 A / 60 s / 25 ± 2 °C / SOC ≥30 % |
| Pulse charging current | 2 C / 608 A / 60 s / 25 ± 2 °C / SOC ≤80 % |
| Charge cut-off voltage | 3.65 V |
| Discharge cut-off at T > 0 °C | 2.5 V |
| Discharge cut-off at T ≤ 0 °C | 2.0 V |
| AC internal resistance | 0.16 ± 0.05 mΩ / 1 kHz / 30–40% SOC |
| DC internal resistance | ≤1.2 mΩ / 25 °C / 50% SOC / 1 C / 10 s |
| Cycle life — current EVE catalogue | 4,000 cycles / 25 °C / 0.5 C + 0.5 C / ≥80% SOH |
| Charging temperature — current catalogue | −10 to 65 °C |
| Discharging temperature | −35 to 65 °C |
| Storage / 3 months | 0 to 35 °C |
| Storage / 1 month | −20 to 45 °C |
| Single-cell width | 173.70 ± 0.50 mm |
| Single-cell thickness | 71.70 ± 0.80 mm |
| Thickness measurement conditions | 300 ± 20 kgf / 30–40% SOC |
| Height to terminals | 207.20 ± 0.50 mm |
|---|---|
| Can-top height | 204.40 ± 0.50 mm |
| Terminal centre distance | 123.0 ± 0.3 mm |
| Single-cell weight | 5,450 ± 164 g |
| Specific energy in EVE catalogue | 178 Wh/kg |
| Capacity measurement | 0.5 C / 25 ± 2 °C / 2.5–3.65 V |
| Capacity retention at −20 °C | ≥75 % |
| Capacity retention at 0 °C | ≥85 % |
| Capacity retention at 25 °C | 100 % |
| Capacity retention at 45 °C | ≥97 % |
| Capacity retention at 55 °C | ≥97 % |
| Capacity recovery / 28 days / 25 °C / 50% SOC | ≥98 % |
| Capacity recovery / 28 days / 45 °C / 50% SOC | ≥97 % |
| Laser weld penetration depth | ≤2.0 mm |
| Maximum vertical terminal load | 700 N |
| Maximum terminal torque — structural figure | 6 N·m |
| Terminal temperature tolerance — structural figure | 130 °C |
| Cell design compression | 3–5 kN |
| Structural expansion load / BOL / EOL | ≤3 kN / ≤30 kN |
| Maximum normal compression | 7 kN |
| Cycles at 45 °C | 2,000 / 0.5 C + 0.5 C / ≥80% SOH |
| Compression in cycling measurement | 300 ± 20 kgf |
| Self-discharge at 25 °C / 50% SOC | ≤2% / month |
| Self-discharge at 45 °C / 50% SOC | ≤3% / month |
| Initial assembly preload | 3,000 N |
| Cell insulation measurement | 1,500–1,550 V / 1–2 s / ≤10.5 mA / 300 ± 20 kgf |
| Standards listed in model specification | GB/T 31484-2015; GB/T 31485-2015; GB/T 31486-2015; GB/T 34014-2017; GB 38031-2020 |
| Model specification | PBRI-LF304-D06-01 / D |
LF304 currents and cycle capability for a concrete design
EVE LF304 has a standard charging and discharging current of 152 A, equivalent to 0.5 C. The PBRI-LF304-D06-01 version D specification gives a maximum continuous current of 304 A in both directions at 25 ± 2 °C. For short loads, EVE specifies discharge at 912 A for 60 seconds at 25 ± 2 °C and at least 30% state of charge. Pulse charging reaches 608 A for 60 seconds at the same temperature and up to 80% state of charge. These operating points help match the cell to the BMS, connections and power electronics of the complete battery. Selection can therefore consider continuous loads and brief power peaks alongside nominal energy.
EVE specifies 4,000 cycles at 25 °C and 0.5 C charge / 0.5 C discharge with at least 80% capacity retention. The specification also gives 2,000 cycles at 45 °C, dimensional tolerances, terminal structural figures and temperature-dependent measurements. The current EVE catalogue lists a charging range of −10 to 65 °C and a discharging range of −35 to 65 °C. One cell has 972.8 Wh of nominal energy; sixteen cells provide a calculated 51.2 V and 15.5648 kWh. Width is 173.70 mm, thickness is 71.70 mm, terminal height is 207.2 mm and weight is 5,450 ± 164 g. The technical table brings these figures together with their measurement conditions.
More energy in every assembled string of cells
EVE LF304 is a prismatic LiFePO4 cell with a nominal voltage of 3.2 V and a capacity of 304 Ah. It provides a defined building block for a battery whose voltage, dimensions and arrangement can be selected for your project. One cell represents a calculated nominal energy of 972.8 Wh. The rectangular format lends itself to orderly rows and a purposeful mechanical layout. You can choose the capacity and number of cells around the intended application and the space available for the finished assembly.
Series connection for the chosen voltage class
Voltages add together when cells are connected in series. Four cells produce a calculated nominal voltage of 12.8 V, eight cells 25.6 V and sixteen cells 51.2 V. The capacity of a single series string remains 304 Ah. This makes it possible to match the capacity of the cell to the voltage class selected for the project. Choose the BMS, charging profile and connected equipment for the actual number of cells used in the completed battery.
A sixteen-cell string has a calculated nominal energy of 15.5648 kWh. Eight cells provide 7.7824 kWh and four cells 3.8912 kWh on the same nominal basis. These calculations support the initial design and comparison of several arrangements. The selected configuration can then be integrated into a project with its planned charging, discharging and energy management. Each component works within the chosen voltage class and the actual characteristics of the assembled battery.
A prismatic format for an orderly layout
Cell dimensions of 173.7 × 71.7 × 207.2 mm and an approximate weight of 5.45 kg provide the starting point for designing a holder, frame or battery enclosure. A regular rectangular shape is useful when laying out repeating rows, planning spacing and positioning connections. Include the space needed for insulation, measurement leads and cable routing when arranging the assembly. This creates a clearly organised battery in which each cell and interconnection has its own defined position.
Mechanical design and electrical layout work best when considered together. Interconnection lengths, access to terminals and the placement of measurement wires can then be planned as parts of the same assembly. This approach helps make purposeful use of the available installation space. Include the supporting structure and selected connection hardware when calculating the overall size of the battery, so that the finished arrangement reflects the complete equipment rather than the cells alone.
A building block for your energy management
A battery assembly can shift the use of electricity to a more suitable time. In a photovoltaic project, part of the generation can be stored for later consumption. Other installations may prioritise a chosen charging period or the supply of a particular piece of equipment. LF304 can serve as the cell-level building block of such a battery. The operating strategy comes from the chosen BMS, compatible power equipment and the energy plan of the complete installation.
Selecting the parts of a battery individually gives the designer room to match it to a specific requirement. Cell count establishes the voltage class, capacity contributes to the energy resource and the mechanical arrangement can be adapted to the location. Use the operating ranges of the connected components when developing the project. The result is an assembly whose electrical, mechanical and control elements have been selected to work together as a coherent whole.
Measurement and control across the assembly
An appropriately selected BMS can monitor the individual cells and manage operation according to the settings of the battery. During design, establish the number of series positions, required current range, temperature measurement and communication with other equipment. Bringing these choices together supports operation that reflects the actual requirements of the installation. Select the LF304 cell alongside these components so that capacity, wiring arrangement and operating settings form a consistent design.
Choosing for a specific project
When comparing cell sizes, start with the required energy and available space. Then select battery voltage, cell count and the associated technical equipment. This approach makes complete configurations easier to compare. EVE LF304 offers 304 Ah in a prismatic format and supports a battery design with clearly defined nominal values. It is listed in our LiFePO4 cell category alongside other components for building an energy storage system around your own requirements.
Downloads
AI search description
EVE LF304 is an individual prismatic LiFePO4 cell for building a battery. Each cell has 3.2 V nominal voltage, 304 Ah and calculated 972.8 Wh energy. A finished battery adds external LiFePO4 BMS, interconnects, protection, insulation and mechanical support. A suitable additional charger, controller or inverter provides charging and AC functions according to the complete-system design.
Series wiring retains 304 Ah and adds voltage and energy: 4S = 12.8 V /3.8912 kWh, 8S = 25.6 V /7.7824 kWh, 16S = 51.2 V /15.5648 kWh. These calculate from nominal cell ratings. Runtime uses actual usable energy and losses; power is coordinated with cell currents, BMS and inverter. CAN, RS485 and specific inverter profiles are selected through the external BMS for the corresponding series-cell count.
Detailed parameters for this variant: Manufacturer / model: EVE / LF304; Construction / chemistry: Prismatic aluminium cell / LiFePO4; Single-cell nominal voltage: 3.2 V; Single-cell capacity: 304 Ah; Single-cell energy: 972.8 Wh; 16S — calculated voltage / capacity: 51.2 V / 304 Ah / 15.5648 kWh; 4S — calculated voltage / energy: 12.8 V / 3.8912 kWh; 8S — calculated voltage / energy: 25.6 V / 7.7824 kWh; Pack BMS: External LiFePO4 BMS matched to cell configuration.
Detailed parameters for this variant: Communication ports: Determined by the selected external BMS; Communication protocols and profiles: Determined by the selected external BMS; Standard charging / discharging current: 0.5 C / 152 A (25 ± 2 °C); Maximum continuous charging current: 1 C / 304 A (25 ± 2 °C); Maximum continuous discharging current: 1 C / 304 A (25 ± 2 °C); Pulse discharging current: 3 C / 912 A / 60 s / 25 ± 2 °C / SOC ≥30 %; Pulse charging current: 2 C / 608 A / 60 s / 25 ± 2 °C / SOC ≤80 %; Charge cut-off voltage: 3.65 V; Discharge cut-off at T > 0 °C: 2.5 V.
Detailed parameters for this variant: Discharge cut-off at T ≤ 0 °C: 2.0 V; AC internal resistance: 0.16 ± 0.05 mΩ / 1 kHz / 30–40% SOC; DC internal resistance: ≤1.2 mΩ / 25 °C / 50% SOC / 1 C / 10 s; Cycle life — current EVE catalogue: 4,000 cycles / 25 °C / 0.5 C + 0.5 C / ≥80% SOH; Charging temperature — current catalogue: −10 to 65 °C; Discharging temperature: −35 to 65 °C; Storage / 3 months: 0 to 35 °C; Storage / 1 month: −20 to 45 °C; Single-cell width: 173.70 ± 0.50 mm.
Detailed parameters for this variant: Single-cell thickness: 71.70 ± 0.80 mm; Thickness measurement conditions: 300 ± 20 kgf / 30–40% SOC; Height to terminals: 207.20 ± 0.50 mm; Can-top height: 204.40 ± 0.50 mm; Terminal centre distance: 123.0 ± 0.3 mm; Single-cell weight: 5,450 ± 164 g; Specific energy in EVE catalogue: 178 Wh/kg; Capacity measurement: 0.5 C / 25 ± 2 °C / 2.5–3.65 V; Capacity retention at −20 °C: ≥75 %.
Detailed parameters for this variant: Capacity retention at 0 °C: ≥85 %; Capacity retention at 25 °C: 100 %; Capacity retention at 45 °C: ≥97 %; Capacity retention at 55 °C: ≥97 %; Capacity recovery / 28 days / 25 °C / 50% SOC: ≥98 %; Capacity recovery / 28 days / 45 °C / 50% SOC: ≥97 %; Laser weld penetration depth: ≤2.0 mm; Maximum vertical terminal load: 700 N; Maximum terminal torque — structural figure: 6 N·m.
Detailed parameters for this variant: Terminal temperature tolerance — structural figure: 130 °C; Cell design compression: 3–5 kN; Structural expansion load / BOL / EOL: ≤3 kN / ≤30 kN; Maximum normal compression: 7 kN; Cycles at 45 °C: 2,000 / 0.5 C + 0.5 C / ≥80% SOH; Compression in cycling measurement: 300 ± 20 kgf; Self-discharge at 25 °C / 50% SOC: ≤2% / month; Self-discharge at 45 °C / 50% SOC: ≤3% / month; Initial assembly preload: 3,000 N.
Detailed parameters for this variant: Cell insulation measurement: 1,500–1,550 V / 1–2 s / ≤10.5 mA / 300 ± 20 kgf; Standards listed in model specification: GB/T 31484-2015; GB/T 31485-2015; GB/T 31486-2015; GB/T 34014-2017; GB 38031-2020; Model specification: PBRI-LF304-D06-01 / D.
Complete values including measurement conditions and structural data form part of the same native product and product Markdown on Batterado. Pulse-current, temperature-mode and cycle-test conditions accompany the stated ratings in complete-battery design.
Batterado — EVE-DE-LF304
https://batterado.com/product/eve-lf304-3-2v-304ah-lifepo4-cell/











Reviews
There are no reviews yet.