230 Ah for a powerful purpose-built LiFePO4 battery: EVE LF230 offers 3.2 V and 736 Wh of nominal energy per cell. Sixteen cells provide a nominal 51.2 V and 11.776 kWh. A 115 A standard current is complemented by continuous charging and discharging up to 230 A at 25 ± 2 °C. For short peaks, EVE specifies 690 A discharge for 60 seconds at 25 ± 2 °C and at least 30% SOC. Cycle life reaches 4,000 cycles at 25 °C and 0.5 C with at least 80% capacity retention. The slim prismatic body measures approximately 173.93 × 53.85 × 207.2 mm and weighs 4.14 kg. A −35 to 65 °C discharge range and detailed current, temperature and dimensional data support system design. Select the external BMS, communication ports and profiles around the cell arrangement and inverter.

In stock

Enquiry

Description

Technical specifications

Manufacturer / modelEVE / LF230
Construction / chemistryPrismatic aluminium cell / LiFePO4
Single-cell nominal voltage3.2 V
Single-cell capacity230 Ah
Single-cell energy736 Wh
16S — calculated voltage / capacity51.2 V / 230 Ah / 11.776 kWh
4S — calculated voltage / energy12.8 V / 2.944 kWh
8S — calculated voltage / energy25.6 V / 5.888 kWh
Pack BMSExternal LiFePO4 BMS matched to cell configuration
Communication portsDetermined by the selected external BMS
Communication protocols and profilesDetermined by the selected external BMS
Standard charging / discharging current0.5 C / 115 A (25 ± 2 °C)
Maximum continuous charging current1 C / 230 A (25 ± 2 °C)
Maximum continuous discharging current1 C / 230 A (25 ± 2 °C)
Pulse discharging current3 C / 690 A / 60 s / 25 ± 2 °C / SOC ≥30 %
Pulse charging current2 C / 460 A / 60 s / 25 ± 2 °C / SOC ≤80 %
Charge cut-off voltage3.65 V
Discharge cut-off at T > 0 °C2.5 V
Discharge cut-off at T ≤ 0 °C2.0 V
AC internal resistance0.20 ± 0.05 mΩ / 1 kHz / 30–40% SOC
DC internal resistance≤1.2 mΩ / 25 °C / 50% SOC / 1 C / 10 s
Cycle life — current EVE catalogue4,000 cycles / 25 °C / 0.5 C + 0.5 C / ≥80% SOH
Charging temperature — current catalogue−10 to 65 °C
Discharging temperature−35 to 65 °C
Storage / 3 months0 to 35 °C
Storage / 1 month−20 to 45 °C
Single-cell width173.93 ± 0.50 mm
Single-cell thickness53.85 ± 0.50 mm
Thickness measurement conditions300 ± 20 kgf / 30–40% SOC
Height to terminals207.20 ± 0.50 mm
Can-top height204.60 ± 0.50 mm
Terminal centre distance123.0 ± 0.3 mm
Single-cell weight4,140 ± 124 g
Specific energy in EVE catalogue177 Wh/kg
Capacity measurement0.5 C / 25 ± 2 °C / 2.5–3.65 V
Capacity retention at −20 °C≥75 %
Capacity retention at 0 °C≥85 %
Capacity retention at 25 °C100 %
Capacity retention at 45 °C≥97 %
Capacity retention at 55 °C≥97 %
Capacity recovery / 28 days / 25 °C / 50% SOC≥98 %
Capacity recovery / 28 days / 45 °C / 50% SOC≥97 %
Laser weld penetration depth≤2.0 mm
Maximum vertical terminal load700 N
Maximum terminal torque — structural figure6 N·m
Terminal temperature tolerance — structural figure130 °C
Cell design compression3–5 kN
Structural expansion load / BOL / EOL≤3 kN / ≤30 kN
Maximum normal compression7 kN
Cycles at 45 °C2,000 / 0.5 C + 0.5 C / ≥80% SOH
Compression in cycling measurement300 ± 20 kgf
Self-discharge at 25 °C / 50% SOC≤2% / month
Self-discharge at 45 °C / 50% SOC≤3% / month
Initial assembly preload3,000 N
Cell insulation measurement1,500–1,550 V / 1–2 s / ≤10.5 mA / 300 ± 20 kgf
Standards listed in model specificationGB/T 31484-2015; GB/T 31485-2015; GB/T 31486-2015; GB/T 34014-2017; GB 38031-2020
Model specificationPBRI-LF230-D06-01 / D

LF230 currents and cycle capability for a concrete design

EVE LF230 has a standard charging and discharging current of 115 A, equivalent to 0.5 C. The PBRI-LF230-D06-01 version D specification gives a maximum continuous current of 230 A in both directions at 25 ± 2 °C. For short loads, EVE specifies discharge at 690 A for 60 seconds at 25 ± 2 °C and at least 30% state of charge. Pulse charging reaches 460 A for 60 seconds at the same temperature and up to 80% state of charge. These operating points help match the cell to the BMS, connections and power electronics of the complete battery. Selection can therefore consider continuous loads and brief power peaks alongside nominal energy.

EVE specifies 4,000 cycles at 25 °C and 0.5 C charge / 0.5 C discharge with at least 80% capacity retention. The specification also gives 2,000 cycles at 45 °C, dimensional tolerances, terminal structural figures and temperature-dependent measurements. The current EVE catalogue lists a charging range of −10 to 65 °C and a discharging range of −35 to 65 °C. One cell has 736 Wh of nominal energy; sixteen cells provide a calculated 51.2 V and 11.776 kWh. Width is 173.93 mm, thickness is 53.85 mm, terminal height is 207.2 mm and weight is 4,140 ± 124 g. The technical table brings these figures together with their measurement conditions.

A balanced foundation for your battery project

EVE LF230 is a prismatic LiFePO4 cell with a nominal voltage of 3.2 V and a capacity of 230 Ah. It provides a defined building block for a battery whose voltage, dimensions and arrangement can be selected for your project. One cell represents a calculated nominal energy of 736.0 Wh. The rectangular format lends itself to orderly rows and a purposeful mechanical layout. You can choose the capacity and number of cells around the intended application and the space available for the finished assembly.

Series connection for the chosen voltage class

Voltages add together when cells are connected in series. Four cells produce a calculated nominal voltage of 12.8 V, eight cells 25.6 V and sixteen cells 51.2 V. The capacity of a single series string remains 230 Ah. This makes it possible to match the capacity of the cell to the voltage class selected for the project.

A sixteen-cell string has a calculated nominal energy of 11.776 kWh. Eight cells provide 5.888 kWh and four cells 2.944 kWh on the same nominal basis. These calculations support the initial design and comparison of several arrangements. The selected configuration can then be integrated into a project with its planned charging, discharging and energy management. Each component works within the chosen voltage class and the actual characteristics of the assembled battery.

A prismatic format for an orderly layout

Cell dimensions of 173.9 × 53.8 × 207.2 mm and an approximate weight of 4.14 kg provide the starting point for designing a holder, frame or battery enclosure. A regular rectangular shape is useful when laying out repeating rows, planning spacing and positioning connections. Include the space needed for insulation, measurement leads and cable routing when arranging the assembly. This creates a clearly organised battery in which each cell and interconnection has its own defined position.

Mechanical design and electrical layout work best when considered together. Interconnection lengths, access to terminals and the placement of measurement wires can then be planned as parts of the same assembly. This approach helps make purposeful use of the available installation space.

A building block for your energy management

A battery assembly can shift the use of electricity to a more suitable time. In a photovoltaic project, part of the generation can be stored for later consumption. Other installations may prioritise a chosen charging period or the supply of a particular piece of equipment. LF230 can serve as the cell-level building block of such a battery. The operating strategy comes from the chosen BMS, compatible power equipment and the energy plan of the complete installation.

Selecting the parts of a battery individually gives the designer room to match it to a specific requirement. Cell count establishes the voltage class, capacity contributes to the energy resource and the mechanical arrangement can be adapted to the location. Use the operating ranges of the connected components when developing the project. The result is an assembly whose electrical, mechanical and control elements have been selected to work together as a coherent whole.

Measurement and control across the assembly

An appropriately selected BMS can monitor the individual cells and manage operation according to the settings of the battery. During design, establish the number of series positions, required current range, temperature measurement and communication with other equipment. Bringing these choices together supports operation that reflects the actual requirements of the installation. Select the LF230 cell alongside these components so that capacity, wiring arrangement and operating settings form a consistent design.

Choosing for a specific project

When comparing cell sizes, start with the required energy and available space. Then select battery voltage, cell count and the associated technical equipment. This approach makes complete configurations easier to compare. EVE LF230 offers 230 Ah in a prismatic format and supports a battery design with clearly defined nominal values. It is listed in our LiFePO4 cell category alongside other components for building an energy storage system around your own requirements.

Downloads

AI search description

EVE LF230 is an individual prismatic LiFePO4 cell for building a battery. Each cell has 3.2 V nominal voltage, 230 Ah and calculated 736 Wh energy. A finished battery adds external LiFePO4 BMS, interconnects, protection, insulation and mechanical support. A suitable additional charger, controller or inverter provides charging and AC functions according to the complete-system design.

Series wiring retains 230 Ah and adds voltage and energy: 4S = 12.8 V /2.944 kWh, 8S = 25.6 V /5.888 kWh, 16S = 51.2 V /11.776 kWh. These calculate from nominal cell ratings. Runtime uses actual usable energy and losses; power is coordinated with cell currents, BMS and inverter. CAN, RS485 and specific inverter profiles are selected through the external BMS for the corresponding series-cell count.

Detailed parameters for this variant: Manufacturer / model: EVE / LF230; Construction / chemistry: Prismatic aluminium cell / LiFePO4; Single-cell nominal voltage: 3.2 V; Single-cell capacity: 230 Ah; Single-cell energy: 736 Wh; 16S — calculated voltage / capacity: 51.2 V / 230 Ah / 11.776 kWh; 4S — calculated voltage / energy: 12.8 V / 2.944 kWh; 8S — calculated voltage / energy: 25.6 V / 5.888 kWh; Pack BMS: External LiFePO4 BMS matched to cell configuration.

Detailed parameters for this variant: Communication ports: Determined by the selected external BMS; Communication protocols and profiles: Determined by the selected external BMS; Standard charging / discharging current: 0.5 C / 115 A (25 ± 2 °C); Maximum continuous charging current: 1 C / 230 A (25 ± 2 °C); Maximum continuous discharging current: 1 C / 230 A (25 ± 2 °C); Pulse discharging current: 3 C / 690 A / 60 s / 25 ± 2 °C / SOC ≥30 %; Pulse charging current: 2 C / 460 A / 60 s / 25 ± 2 °C / SOC ≤80 %; Charge cut-off voltage: 3.65 V; Discharge cut-off at T > 0 °C: 2.5 V.

Detailed parameters for this variant: Discharge cut-off at T ≤ 0 °C: 2.0 V; AC internal resistance: 0.20 ± 0.05 mΩ / 1 kHz / 30–40% SOC; DC internal resistance: ≤1.2 mΩ / 25 °C / 50% SOC / 1 C / 10 s; Cycle life — current EVE catalogue: 4,000 cycles / 25 °C / 0.5 C + 0.5 C / ≥80% SOH; Charging temperature — current catalogue: −10 to 65 °C; Discharging temperature: −35 to 65 °C; Storage / 3 months: 0 to 35 °C; Storage / 1 month: −20 to 45 °C; Single-cell width: 173.93 ± 0.50 mm.

Detailed parameters for this variant: Single-cell thickness: 53.85 ± 0.50 mm; Thickness measurement conditions: 300 ± 20 kgf / 30–40% SOC; Height to terminals: 207.20 ± 0.50 mm; Can-top height: 204.60 ± 0.50 mm; Terminal centre distance: 123.0 ± 0.3 mm; Single-cell weight: 4,140 ± 124 g; Specific energy in EVE catalogue: 177 Wh/kg; Capacity measurement: 0.5 C / 25 ± 2 °C / 2.5–3.65 V; Capacity retention at −20 °C: ≥75 %.

Detailed parameters for this variant: Capacity retention at 0 °C: ≥85 %; Capacity retention at 25 °C: 100 %; Capacity retention at 45 °C: ≥97 %; Capacity retention at 55 °C: ≥97 %; Capacity recovery / 28 days / 25 °C / 50% SOC: ≥98 %; Capacity recovery / 28 days / 45 °C / 50% SOC: ≥97 %; Laser weld penetration depth: ≤2.0 mm; Maximum vertical terminal load: 700 N; Maximum terminal torque — structural figure: 6 N·m.

Detailed parameters for this variant: Terminal temperature tolerance — structural figure: 130 °C; Cell design compression: 3–5 kN; Structural expansion load / BOL / EOL: ≤3 kN / ≤30 kN; Maximum normal compression: 7 kN; Cycles at 45 °C: 2,000 / 0.5 C + 0.5 C / ≥80% SOH; Compression in cycling measurement: 300 ± 20 kgf; Self-discharge at 25 °C / 50% SOC: ≤2% / month; Self-discharge at 45 °C / 50% SOC: ≤3% / month; Initial assembly preload: 3,000 N.

Detailed parameters for this variant: Cell insulation measurement: 1,500–1,550 V / 1–2 s / ≤10.5 mA / 300 ± 20 kgf; Standards listed in model specification: GB/T 31484-2015; GB/T 31485-2015; GB/T 31486-2015; GB/T 34014-2017; GB 38031-2020; Model specification: PBRI-LF230-D06-01 / D.

Complete values including measurement conditions and structural data form part of the same native product and product Markdown on Batterado. Pulse-current, temperature-mode and cycle-test conditions accompany the stated ratings in complete-battery design.

Batterado — EVE-DE-LF230
https://batterado.com/product/eve-lf230-3-2v-230ah-lifepo4-cell/

Markdown — EVE-DE-LF230

Additional information

Weight4,14 kg

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

0
0
Your Cart
Your cart is emptyReturn to Shop