Description
Technical data
| Brand | Victron Energy |
|---|---|
| Model | Multi RS Solar 48/6000/100-450/100 |
| Order code | PMR482602020 |
| Type | Hybrid inverter with charger, two MPPT trackers and transfer switch |
| Nominal battery voltage | 48 V |
| Inverter: DC input voltage range | 38–62 V (minimum start-up voltage 41 V, over-voltage disconnect 65.5 V) |
| Inverter: AC output voltage | 230 V ± 2 % (adjustable to 240 V) |
| Inverter: output frequency | 50 Hz ± 0.1 % (adjustable to 60 Hz) |
| Inverter: max. continuous inverter current | 25 A AC |
| Inverter: continuous power at 25 °C | 4,600 W at 46 V DC, rising linearly to 5,200 W at 52 V DC |
| Inverter: continuous power at 40 °C | 4,500 W |
| Inverter: continuous power at 65 °C | 3,000 W |
| Inverter: peak power | 9 kW for 3 s; 7 kW for 4 min (cold start) |
| Inverter: output short-circuit current | 45 A |
| Inverter: max. AC output overcurrent protection | 30 A |
| Inverter: max. efficiency | 96.5 % at 1 kW load; 94 % at 5 kW load |
| Inverter: zero load power | 20 W |
| Low battery shutdown | 37.2 V (adjustable) |
| Low battery restart | 43.6 V (adjustable) |
| Solar: max. open circuit PV array voltage | 450 V |
| Solar: start-up voltage | 120 V |
| Solar: MPPT operating voltage range | 65–450 V |
| Solar: max. operational PV input current limit | 12 A |
| Solar: max. PV conversion power | 6 kW total, 3 kW per tracker |
| Solar: max. PV short circuit current | 16 A |
| Solar: earth leakage trip level | 30 mA |
| Solar: isolation fail level (detection before start-up) | 100 kΩ |
| AC input: nominal voltage and frequency | 230 V AC, 50 Hz (input voltage range 187–265 V, frequency 45–65 Hz) |
| Charger: programmable charge voltage range | 36–60 V |
| Charger: absorption voltage | 57.6 V (default, adjustable) |
| Charger: float voltage | 55.2 V (default, adjustable) |
| Charger: max. charge current from AC | 88 A at 57.6 V DC |
| Charger: total max. charge current (AC + PV) | 100 A DC |
| Battery temperature sensor | included |
| Battery voltage sense | yes |
|---|---|
| Icw and Ipk requirements | Icw: 500 A @ 0,1 s, Ipk: 2 kA |
| AC input: max. input current | 50 A (input and pass-through) |
| Transfer switch | 50 A |
| PowerControl and PowerAssist | yes |
| Auxiliary AC output (AC-out-2) | yes (AC-out-2 is connected directly to the AC input, for non-critical loads) |
| Operating modes | hybrid, backup, off-grid, generator, PV inverter (without battery) |
| Three-phase and parallel operation | three-phase operation with one unit per phase; parallel operation is not supported |
| Programmable relay | yes (general alarm, DC undervoltage or genset start/stop; DC rating 4 A up to 35 V DC and 1 A up to 70 V DC) |
| Protection | output short circuit, overload, battery voltage too high, battery voltage too low, temperature too high, 230 V AC on inverter output, solar earth leakage |
| Data communication ports | VE.Direct, VE.Can, Bluetooth |
| Bluetooth frequency and power | 2402–2480 MHz, 4 dBm |
| Programmable analogue/digital inputs/outputs | yes, 2× |
| Remote on/off terminal | yes |
| Display and Bluetooth | display showing battery, inverter and solar parameters; Bluetooth for the VictronConnect app |
| Configuration and remote control | VictronConnect app (Bluetooth) |
| Compatibility: GX devices | GX devices (e.g. Cerbo GX) via the VE.Can interface; not compatible with VE.Smart Networks |
| Compatibility: energy meter and GlobalLink | Victron VM-3P75CT energy meter via VE.Can or Ethernet; GlobalLink 520 via VE.Direct |
| Compatibility: PV capacity extension | adding solar chargers (DC-coupled) or PV inverters (AC-coupled, frequency shift power control) |
| Operating temperature range | −40 to +65 °C (fan-assisted cooling) |
| Humidity (non-condensing) | max. 95 % |
| Maximum altitude | 2000 m |
| Earthing system | TN and TT only |
| Material and colour | steel, blue RAL 5012 |
| Protection category | IP21, protective class I |
| Dimensions (h × w × d) | 462 × 425 × 127 mm |
| Weight | 12.3 kg |
| Battery connection | M8 bolts |
| PV connection | 2 strings, each with positive and negative MC4 |
| AC connection | screw terminals 10 mm² (6 AWG) |
| Standards: safety | EN-IEC 60335-1, EN-IEC 60335-2-29, EN-IEC 62109-1, EN-IEC 62109-2, IEC 62040, IEC 62477 |
| Standards: emission and immunity (EMC) | EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3, IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3, Pollution Degree 2 |
| Overvoltage category | battery: OVC 1, PV port: OVC II, AC in / AC out: OVC III |
| UPS specification | input 230 V AC, 46 A, 50 Hz; output 230 V AC, 26 A, 50 Hz, 6 kVA / 5 kW; protective device (input and output): max. 50 A circuit breaker |
Inverter, charger and solar controllers in one enclosure
The Victron Energy Multi RS Solar 48/6000/100-450/100 is a hybrid inverter that combines a 6 kVA sine-wave inverter, a 48 V battery charger, two solar MPPT trackers and an AC transfer switch in a single steel enclosure. Compared with a conventional set of inverter, charger and separate solar controller, part of the cabling, enclosures and communication links is eliminated. The unit weighs 12.3 kg and measures 462 × 425 × 127 mm.
The 230 V ± 2 % output at 50 Hz can be adjusted to 240 V and 60 Hz. The DC input range is 38–62 V (minimum start-up voltage 41 V, over-voltage disconnect at 65.5 V). The whole system is set up and monitored via the display, Bluetooth and the VictronConnect app.
Operating modes
The unit works in five modes. In hybrid mode it stores excess solar energy in the battery for the night or periods of high demand and supplies extra power from the battery when demand exceeds grid capacity. In backup mode it switches to battery supply during a grid outage. Off-grid mode operates without a grid connection. In generator mode it controls the generator to minimise run-hours and supplies additional power from the battery when demand exceeds the generator capacity. In PV inverter mode it works as a PV inverter without a battery.
Solar input: two 450 V MPPT trackers
The integrated solar input has two MPPT trackers with a total power of 6 kW (3 kW per tracker). The MPPT operating voltage range is 65–450 V, the start-up voltage 120 V and the maximum open circuit voltage 450 V. The maximum operational input current is 12 A and the maximum PV short circuit current 16 A. Two strings are connected, each through a positive and a negative MC4 connector.
When designing the array, follow this rule: the maximum PV voltage must not exceed 8 times the battery float voltage, for example no more than 8 × 50 = 400 V for a 50 V battery. The unit monitors earth leakage current (trip level 30 mA) and checks insulation before start-up (fail level 100 kΩ).
Inverter power and temperature dependence
Continuous inverter power depends on battery voltage and temperature. At 25 °C it rises linearly from 4,600 W at 46 V DC to 5,200 W at 52 V DC; at 40 °C it is 4,500 W and at 65 °C 3,000 W. The maximum continuous inverter current is 25 A AC. For short periods it delivers 9 kW for 3 seconds and 7 kW for 4 minutes; the values apply to a cold unit and depend on the starting temperature of the heatsink. The output short-circuit current is 45 A and the maximum AC output overcurrent protection 30 A.
Efficiency is 96.5 % at 1 kW load and 94 % at 5 kW, zero load consumption 20 W. Low battery shutdown is set to 37.2 V and restart to 43.6 V; both can be adjusted.
Charger and choosing a 48 V battery
The programmable charge voltage range is 36–60 V; the default absorption voltage is 57.6 V and float 55.2 V, both adjustable. From AC the charger delivers up to 88 A at 230 V and 57.6 V (25 °C ambient); the total charge current from grid and solar array together is 100 A DC. The battery temperature sensor is included and the unit can measure voltage directly at the battery (voltage sense).
When choosing a battery, start from the nominal voltage of 48 V and the charge voltages and currents given above; for lithium batteries follow the battery manufacturer’s specifications. The battery is connected with M8 bolts.
PowerControl, PowerAssist and auxiliary output
The PowerControl function sets a maximum grid or generator current; the inverter then uses only what remains after the other loads for charging. PowerAssist tops up insufficient generator or grid power from the battery and recharges it once the load drops. The AC input and transfer switch rating are 50 A.
The auxiliary output AC-out-2 is connected directly to the AC input and intended for non-critical loads. Its load is taken into account by PowerControl and PowerAssist.
Extending solar capacity and three-phase operation
The integrated 6 kWp PV capacity can be extended. With DC coupling, additional solar charge controllers are added to the system. With AC coupling, PV inverters are installed whose output is controlled automatically by the integrated frequency shift power control.
Three-phase operation is supported with one unit per phase. Parallel operation of several units is not supported by this model, so higher power is achieved differently than with the MultiPlus-II range.
Communication, monitoring and configuration
The unit has a display that shows battery, inverter and solar parameters. The same data can be read and settings changed over Bluetooth in the VictronConnect app. A GX device such as the Cerbo GX connects via the VE.Can interface (for system monitoring, energy meter, data logging and remote firmware updates). The VE.Direct interface is intended for the GlobalLink 520 and remote data monitoring. The Victron VM-3P75CT energy meter connects via VE.Can or Ethernet; intermediate WiFi links are not advised between the meter and the GX device. The unit is not currently compatible with VE.Smart Networks.
Available are a programmable relay (alarm, DC undervoltage or genset start/stop), a remote on/off terminal and two programmable analogue/digital input/output ports; a temperature sensor and a battery voltage sense connection can also be attached.
Installation, earthing and standards
The blue steel enclosure (RAL 5012) has IP21 protection and protective class I. The operating range is −40 to +65 °C with fan-assisted cooling, humidity up to 95 % non-condensing and altitude up to 2000 m. The earthing system must be TN or TT. AC wiring goes to screw terminals for 10 mm² (6 AWG).
The unit conforms to EN-IEC 60335-1, EN-IEC 60335-2-29, EN-IEC 62109-1, EN-IEC 62109-2, IEC 62040 and IEC 62477 (safety) and EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3, IEC 61000-6-1, IEC 61000-6-2 and IEC 61000-6-3 (emission and immunity, pollution degree 2). Overvoltage categories: battery OVC 1, PV port OVC II, AC in and AC out OVC III. A circuit breaker of at most 50 A is specified as protection on input and output.
AI search description
The Victron Energy Multi RS Solar 48/6000/100-450/100 (order code PMR482602020) is a 6 kVA hybrid inverter with charger and two MPPT trackers in one enclosure, for a 48 V battery (DC 38–62 V). Inverter power up to 5,200 W at 25 °C, peak 9 kW for 3 s, efficiency 96.5 %. PV input 65–450 V, 6 kW in total (3 kW per tracker). 100 A charger (AC + PV), temperature sensor included. Hybrid, backup, off-grid, generator and PV inverter modes. Display, Bluetooth, VictronConnect, VE.Can for GX devices, VE.Direct. Three-phase with one unit per phase, parallel operation not supported. IP21, 12.3 kg, 462 × 425 × 127 mm.
Product page: https://batterado.com/product/victron-multi-rs-solar-48-6000-100-450-100/