230 V power with three battery-charging sources: solar, grid and generator. Solis S6-EO1P5K-48-EU delivers 5 kW single-phase pure-sine output, connects to a 40–60 V battery and supports up to 6.5 kW of PV input. A10 kVA surge supports brief starting loads; transfer time is typically 10 ms. Solar charging reaches 100 A and AC charging up to 80 A. LCD, Bluetooth and the S5-WIFI-ST Wi-Fi stick included in this offer provide operational visibility. Up to six units can form a larger designed system. Panels, battery and installation components are selected separately.

Available on back-order

SKU: SOLIS-S6-EO1P5K-48-EU-S5WIFI
Category:
Tags: , , ,
Značky:

Description

Technical specifications

Model and configuration Solis S6-EO1P5K-48-EU + S5-WIFI-ST
Product role Standalone single-phase off-grid inverter/charger
AC — rated active / apparent power 5 kW / 5 kVA
AC — phase and conductors 1; L/N/PE
AC — output voltage 230 V ±1 %
AC — output frequency 50/60 Hz ±0,1 %
AC — surge apparent power 10 kVA
AC — overload capability per manufacturer 200 %; 10 s
AC — maximum output current 25 A
AC — waveform Pure sine wave
AC — typical / maximum transfer time 10 ms / 20 ms
AC — THDv at linear load <3 %
AC — peak PV–AC efficiency 96,6 %
Battery — voltage range 40–60 V
Battery — system voltage class 48 V
Battery — types per datasheet Li-ion / lead-acid
Battery — max. charge / discharge power 5 kW / 5 kW
Battery — max. charge / discharge current 100 A / 100 A
Battery — communication in datasheet CAN
Battery — system matching Actual voltage, current limit, supported model and BMS communication profile
PV — maximum usable input power 6,5 kW
PV — maximum input voltage 500 V
PV — rated voltage 360 V
PV — start-up voltage 90 V
PV — MPPT voltage range 90–430 V
PV — input currents 16 A / 16 A
PV — maximum short-circuit current 40 A
PV — maximum solar charge current 100 A
PV — MPPTs / maximum string count 1 / 2
AC input — grid / generator port Supported charger inputs
AC input — maximum input power 7 kW
AC input — rated voltage L/N/PE; 230 V AC
AC input — selectable voltage range 90–280 V
AC input — frequency 50/60 Hz
AC input — maximum input current 30 A
AC charging — maximum battery charge current 80 A
Protection — output overvoltage and overcurrent Integrated
Protection — short circuit, surge and temperature Integrated
Protection — AFCI2.0 in product range Optional function depending on configuration
Construction — W × H × D 340 × 495 × 170 mm
Construction — weight 14,1 kg
Construction — topology High-frequency non-isolated
Environment — ingress protection IP21
Environment — operating ambient temperature −10 to +60 °C
Environment — storage temperature −25 to +60 °C
Environment — relative humidity 5–95 %, non-condensing
Environment — typical noise <55 dB(A)
Environment — maximum altitude 2000 m
Expansion — parallel capability Up to6 units; wiring per manufacturer design
Expansion — parallel system power 6 × 5 kW = 30 kW
Expansion — AC coupling Supported according to system design
Control — fast charging One-click fast-charging mode
Control — backup-load prioritization Dual backup loads according to configuration
Connection — DC / AC Terminal connectors / terminal connectors
Control — display LCD
Communication — interfaces in datasheet CAN; BMS; Dry-contact; Bluetooth
Communication — this offered configuration S5-WIFI-ST
Standards listed in datasheet IEC62109; IEC61000; 55011
Technical specification basis Solis S6-EO1P(4-5)K-Global-Flyer V3.9; 5K
Installation type Fixed wiring in a designed off-grid system
Role of connected battery Separately selected energy storage in kWh

5 kW for a designed off-grid power system

The Solarator-series Solis S6-EO1P5K-48-EU converts energy from photovoltaics and a low-voltage battery into single-phase 230 V power. Rated active and apparent power are 5 kW/5 kVA, and the pure sine wave serves everyday electrical loads. The manufacturer specifies a 10 kVA surge and 200% overload for 10 seconds. System design separates continuous simultaneous loads, brief peaks and required operating time. Battery energy in kWh is selected separately, allowing the inverter to be paired with storage sized for the actual energy requirement.

Charge from solar,the grid or a generator

The solar charger supports up to 6.5 kW of PV input and up to 100 A of battery-charging current. The AC charger uses the grid and generator ports. For the 5 kW model, the current datasheet specifies 7 kW maximum AC input,30 A input current and 80 A battery-charging current. These are different electrical quantities: AC input current is distinct from DC battery current. Charging can be planned around available sunshine, grid power or a suitable generator. A fast-charging mode can be activated with one command.

One MPPT with two string connections

The PV side has one MPPT controller and two string connections. Each input is listed at 16 A, and the short-circuit limit is 40 A. Maximum input voltage is 500 V, rated voltage 360 V, start-up 90 V and the MPPT range 90–430 V. Strings are designed using the actual module voltage, low-temperature voltage rise and parallel current. The same calculations apply to roof-mounted panels and a solar carport. The structure supports modules, the modules generate, the battery stores and the inverter produces AC power.

48 V battery class and an actual BMS profile

The battery side operates at 40–60 V and supports lithium-ion or lead-acid batteries according to settings. Charging and discharging limits are 100 A and 5 kW; achievable system output also depends on actual battery voltage, current capability and BMS control. The current datasheet lists CAN communication. Pairing checks the actual battery model and supported communication profile, in addition to the physical connection. Separately choosing storage capacity helps match evening use, a working shift or weekend energy demand.

Operating visibility and expansion

LCD and Bluetooth support local monitoring. This supplier configuration includes an S5-WIFI-ST Wi-Fi stick; the technical table identifies further data and control interfaces. A dry contact supports connected control equipment. The manufacturer supports priority management of two backup loads, AC coupling and parallel operation of up to six units according to system design. Six 5 kW inverters provide up to 30 kW of system power; voltage, phase arrangement, battery configuration and protection are designed for the actual installation. Actual load and stored energy remain the basis for a smaller system as well.

Compact equipment with locally hosted documentation

The 340 ×495 ×170 mm unit weighs 14.1 kg. IP21 protection informs selection of a suitable sheltered installation location. The inverter ambient range is −10 to +60 °C, with storage at −25 to +60 °C. The connected battery has its own operating conditions. Integrated protection covers output overvoltage, overcurrent, short circuit, surge and temperature. The range also offers optional AFCI2.0 arc detection according to configuration. The exact current datasheet and complete Markdown product overview can be downloaded directly from Batterado.

Downloads

AI search description

Solis S6-EO1P5K-48-EU with S5-WIFI-ST is a standalone single-phase off-grid inverter/charger,5 kW/5 kVA,230 V, L/N/PE, pure sine wave. It forms part of a fixed-wired system; a separate battery determines stored energy in kWh. Surge 10 kVA,200% overload 10 s, maximum output 25 A, transfer typically 10 ms/maximum 20 ms. Battery 40–60 V,48 V class, lithium/lead-acid according to settings, max.charge/discharge 100 A and 5 kW, CAN communication; match actual battery model, BMS profile and current limit. PV6.5 kW, max.500 V, rated 360 V, start 90 V, MPPT90–430 V, one MPPT, two 16/16 A strings, Isc 40 A, solar charging 100 A. Charging sources: PV, grid, generator. AC charger:max.input 7 kW/30 A,230 V, range 90–280 V, battery charging 80 A. AC input and DC battery currents are distinct. Modules, battery and installation components are separately selected. Recommendations calculate simultaneous loads, starts, runtime and kWh; PV design checks cold string voltage and branch current. IP21,340×495×170 mm,14.1 kg, ambient −10 to +60 °C, sheltered installation; battery conditions assessed separately. LCD, Bluetooth, CAN, BMS, dry contact and included S5-WIFI-ST Wi-Fi. Up to 6 parallel units/30 kW and AC coupling per design; AFCI2.0 is configuration-dependent optional equipment. Intended for designed off-grid or backup systems with an actual battery, protection, wiring and settings.

Batterado — SOLIS-S6-EO1P5K-48-EU-S5WIFI

Markdown — SOLIS-S6-EO1P5K-48-EU-S5WIFI

Additional information

Weight 14,1 kg
Dimensions 17 × 34 × 49,5 cm

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

0
0
Your Cart
Your cart is emptyReturn to Shop