Store energy. Every way.™

Solis S6-EH3P12K-H-EU(21A) — 12 kW hybrid inverter, 4 MPPTs, 700 V HV, AFCI

51 391 Kč incl. VAT

Ask about this product

12 kW for PV, battery storage and home backup. Four 21 A MPPTs, a 120–700 V /50 A battery port and 19.2 kVA backup peak for 60 s support a capable system. The offer includes meter, Wi-Fi/LAN, DC/AC Type II surge protection and AFCI 1.0. Manage grid charging and schedules through SolisCloud.

Available on back-order

Description

Technical specifications

Manufacturer Solis / Ginlong Technologies
Manufacturer model S6-EH3P12K-H-EU(21A)
Device type Three-phase hybrid inverter for PV and HV battery
Offered equipment DC switch, Wi-Fi/LAN, meter, DC/AC Type II SPD and AFCI 1.0
Rated AC output 12000 W
Maximum AC apparent output 12000 VA
Rated backup output 12000 W
Peak backup output / duration 19200 VA / 60 s
Backup transfer <10 ms
THDv linear load <3 %
Single-unit output per phase 6000 W
Single-unit imbalance 100 %
MPPT count 4
String count 4
Strings per MPPT 1
Input current per MPPT 21 A
Short-circuit current per MPPT 31.5 A
Recommended PV array rating 24 kWp
Maximum usable PV power 19.2 kW
Maximum input power per MPPT 9000 W
Maximum DC voltage 1000 V
Rated DC voltage 600 V
Start-up voltage 160 V
MPPT range 200–850 V
Full-load MPPT range 250–850 V
Battery type Compatible high-voltage Li-ion system with BMS
Battery voltage 120–700 V
Charge / discharge current 50 / 50 A
Maximum charge / discharge power 12 / 12 kW
Storage capacity In kWh according to selected battery system
Battery-system power According to actual voltage, BMS limit and inverter current
Battery communication CAN / RS485
PV → battery efficiency 98.31 %
Battery ↔ AC efficiency 97.50 %
Grid connection 3/N/PE; 380 / 400 V
Grid frequency 50 / 60 Hz
Rated AC current at 380 /400 V 18.2 / 17.3 A
Maximum AC input current at 380 /400 V 27.3 / 26.0 A
AC input voltage 304–437 / 320–460 V
AC input frequency 45–55 / 55–65 Hz
Power factor >0.99; 0.8 leading / lagging
THDi <3 %
Operating modes Self Use / Feed-in Priority / Off Grid / Peak Shaving
Grid charging Allow Grid Charging setting for schedule or SOC recovery
Time scheduling 6 charging and 6 discharging windows
Backup reserve Adjustable reserved SOC
Default over-discharge SOC 20 %
Default force-charge SOC 10 %
Peak Shaving Pmax + Peak SOC
Local control SolisCloud APP / Bluetooth
Status LEDs Battery / Power / WiFi / RS485 / Bluetooth
Bluetooth BDR / EDR / BLE; 2400–2483.5 MHz; 10 dBm
App roles Installer / Owner
Initial settings Date, time, battery model, meter, grid code and work mode
Parallel system 2–6 identical inverter models
Parallel-system batteries Each inverter has its own battery and BMS connection
Parallel grid configuration Balanced three-phase connection following manufacturer diagram
Parallel communication P-B → P-A; shielded CAT5; ≤5 m
Parallel-system addresses Master 1; Slave 2–6; Parallel Sync
Parallel bus termination At endpoints according to selected original diagram
Standard meter Eastron SDM630MCT
Standard CTs ESCT-TA16; 120 A / 40 mA
Metering above 3 parallel units SDM630MCT V2 + ESCT-T50; 300 A / 5 A
BMS CAN RJ45 4 CAN-H / 5 CAN-L; 3 m
Meter RJ45 1 A / 2 B; 5 m
Eastron terminals 13 B / 14 A
External Modbus RTU RS485 RJ45: 5 A / 4 B
CT orientation Arrow towards grid
DRM Pins 5/6 closed: operation; open: shutdown within 5 s
Grid / Backup connectors Separate grid and backup connectors
PV conductors 4–6 mm²; recommended 4 mm²
PV stripping 7 ±0.5 mm
Battery conductors 8–10 mm²; recommended 10 mm² / 8 AWG
AC conductors per manual 2.5–6 mm²; cable Ø14–17 mm
AC conductor stripping 7 mm
AC terminals / nut 0.8 ±0.1 / 2.5 ±0.5 Nm
Earth terminal M4 / 2 Nm
Communication cover 1.7–2 Nm
Communication glands 6 mm
Ingress protection IP66
Operating temperature −25…+60 °C
Operating humidity 0–100 % RH
Altitude 4000 m
Cooling Natural convection
Noise <46.9 dB(A)
Night consumption <25 W
Dimensions W × H × D 563 × 412 × 230 mm
Weight 34.5 kg
Mounting Vertical wall mounting, up to ±5°
Mounting clearances 200 mm
Bracket hole spacing 515 × 170 mm
Package — main parts Inverter, backplate, manual, dust cover, Bluetooth antenna
Package — fasteners 4 × M4 ×12
Package — metering 1 meter, 3 CTs, 1 meter cable
Package — communication 6 × RJ45; 1 × CAN cable
Package — power connectors Grid 1; Backup 1; BAT 1; PV 4
Optional family protection AFCI 2.0 according to selected family configuration
Estimated delivery 2–3 days
Maximum PV efficiency 97.85 %
European efficiency 97.51 %
Surge protection included DC Type II / AC Type II
Arc protection included AFCI 1.0
Generator connection Grid through ATS and 220 VAC/12 VDC status-signal supply
Generator — DI/DO pins 1 +12 VDC / 3 GND
Generator — settings Grid port power by: generator; Generator Charge; Gen Charge power
Generator — default charge start / stop SOC 25 / 80 %
Heat pump — DI/DO pins 5 S-A / 7 S-B
Heat pump — modes Manual / Smart
Heat pump — default enable / disable SOC 90 / 70 %
Heat pump — default enable / disable power 2000 / −500 W
Heat pump — minimum runtime 5–60 min; default 10 min; step 5 min
Heat pump — Smart logic Enable when both SOC and export conditions hold; disable on either stop condition
AC coupling — meters Grid 001; PV inverter 002
DRM — default S1–S4 power steps 0 / 30 / 60 / 100 %
DRM mode2 — default S4 import limit 4.2 kW
Quick Commission Network Connection → Device Configuration → Create/Add Plant
Quick Commission — app SolisCloud >V5.2.221; Try the new version
Quick Commission diagnostics PV / Grid / Battery / Meter / Alarm

PV, storage and backup in one system

Solis S6-EH3P12K-H-EU(21A) connects PV, a compatible high-voltage battery and three-phase loads. Rated 12 kW describes instantaneous power; selected battery kWh, usable SOC and consumption determine stored energy and runtime. Batterado matches modules, battery, metering and electrical equipment for homes or smaller businesses.

Independent trackers for PV design

Four independent MPPTs connect four strings, each up to 21 A input and 31.5 A short-circuit current. Recommended array is 24 kWp and maximum usable PV input 19.2 kW. Start-up is 160 V, MPPT range 200–850 V and full-load range 250–850 V. Each tracker accepts up to 9000 W input. Design accounts for actual module currents and cold string voltage within the 1000 V maximum.

HV battery matched to energy and power

The 120–700 V battery input works with a compatible Li-ion system and BMS. Maximum charge and discharge current is 50 A, with up to 12 kW according to actual voltage and BMS limits. Design selects exact model, module count, voltage, firmware and communication settings. Battery capacity is selected separately in kWh. PV-to-battery efficiency reaches 98.31%. The chosen battery has its own operating-temperature specifications.

Backup circuit and load allocation

Backup output delivers rated 12 kW and briefly 19.2 kVA for 60 seconds. Transfer takes less than 10 ms. A single unit supports 100% imbalance and up to 6 kW on one phase within total output. Dedicated loads connect to Backup and utility to Grid. Design accounts for simultaneous appliances, starting peaks and battery capability.

Scheduling and grid charging

Self Use prioritises local generation use, Feed-in Priority configured export, Off Grid independent operation and Peak Shaving battery assistance at grid Pmax. Six charge and six discharge windows schedule energy. Allow Grid Charging enables charging during selected times or SOC recovery. Adjustable backup reserve keeps selected energy available. Default over-discharge SOC is 20% and force-charge SOC 10%.

Metering for energy-flow control

The offer includes a meter and Wi-Fi/LAN monitoring. Standard metering uses Eastron SDM630MCT and three ESCT-TA16 120 A/40 mA CTs with arrows towards grid. Meter RJ45 pin 1 A and 2 B connect to Eastron 14 A and 13 B; the supplied cable is 5 m. More than three parallel units use the matching SDM630MCT V2 and ESCT-T50 300 A/5 A kit according to the manual.

Bluetooth, app and communications

SolisCloud provides local Bluetooth configuration and remote information through included Wi-Fi/LAN. Installer and Owner roles expose corresponding settings and operating data. Commissioning sets time, battery, meter, grid code and mode. Five LEDs show Battery, Power, WiFi, RS485 and Bluetooth. BMS CAN uses pins 4 H and 5 L with a 3 m cable; separate external Modbus RTU uses RS485 pin 5 A and 4 B. The current manual also describes a generator at Grid through ATS, a 12 VDC status signal and a 220 VAC/12 VDC converter. App settings select generator source, charging and charge power; default charge SOC is 25–80%. DI/DO 5 and 7 control a supported heat pump manually or in Smart mode using SOC and export. Defaults enable at 90% SOC and 2000 W export, disable at 70% or −500 W. Minimum runtime is adjustable 5–60 minutes.

Expansion with two to six identical units

A parallel system connects two to six identical inverter models through P-B and P-A using recommended shielded CAT5 up to 5 m between units. Each inverter uses its own battery and BMS connection. Primary address is 1, others 2–6; configure unit count and Parallel Sync. Grid side uses a balanced three-phase design. Bus endpoint termination follows the selected original manual diagram.

IP66 and natural cooling

The IP66 enclosure operates from −25 to +60 °C with natural convection. Dimensions are 563 ×412 ×230 mm and weight 34.5 kg. Vertical wall mounting allows ±5°, bracket spacing 515 ×170 mm and 200 mm clearance for airflow and access. Location and supporting structure suit actual weight and installation conditions. Manufacturer noise rating is below 46.9 dB(A).

Connections for the designed plant

PV uses 4–6 mm² conductors, recommended 4 mm²; battery 10 mm² and manual AC specification 2.5–6 mm² with cable diameter 14–17 mm. Grid and Backup have separate quick connectors. AC terminal torque is 0.8±0.1 Nm, nut 2.5±0.5 Nm and M4 earth 2 Nm. Final design adds suitable protection and earthing. The family supports optional AFCI 2.0 and DC/AC Type II SPD versions according to selected equipment. The offered price configuration includes both DC and AC Type II surge protection and AFCI 1.0.

Equipment and complete-system selection

The package includes inverter, backplate, four M4×12 screws, cover, Bluetooth antenna, meter with three CTs, meter cable, CAN cable, six RJ45s, Grid/Backup/BAT connectors and 4 pairs of PV connectors. Offered configuration adds Wi-Fi/LAN monitoring. A complete plant uses selected modules, mounting accessories, matching HV battery and electrical equipment. Batterado connects kW output with required kWh energy and actual appliance use.

Downloads

AI search description

Solis S6-EH3P12K-H-EU(21A) — 12 kW hybrid inverter, 4 MPPTs, 700 V HV, AFCI. Solis S6-EH3P12K-H-EU(21A) connects PV, a compatible high-voltage battery and three-phase loads. Rated 12 kW describes instantaneous power; selected battery kWh, usable SOC and consumption determine stored energy and runtime. Batterado matches modules, battery, metering and electrical equipment for homes or smaller businesses. The 120–700 V battery input works with a compatible Li-ion system and BMS. Maximum charge and discharge current is 50 A, with up to 12 kW according to actual voltage and BMS limits. Design selects exact model, module count, voltage, firmware and communication settings. Battery capacity is selected separately in kWh. PV-to-battery efficiency reaches 98.31%. The chosen battery has its own operating-temperature specifications.

Manufacturer: Solis / Ginlong Technologies; Manufacturer model: S6-EH3P12K-H-EU(21A); Device type: Three-phase hybrid inverter for PV and HV battery; Offered equipment: DC switch, Wi-Fi/LAN, meter, DC/AC Type II SPD and AFCI 1.0; Rated AC output: 12000 W; Maximum AC apparent output: 12000 VA; Rated backup output: 12000 W; Peak backup output / duration: 19200 VA / 60 s; Backup transfer: <10 ms; THDv linear load: <3 %; Single-unit output per phase: 6000 W; Single-unit imbalance: 100 %; MPPT count: 4; String count: 4; Strings per MPPT: 1; Input current per MPPT: 21 A; Short-circuit current per MPPT: 31.5 A; Recommended PV array rating: 24 kWp; Maximum usable PV power: 19.2 kW; Maximum input power per MPPT: 9000 W; Maximum DC voltage: 1000 V; Rated DC voltage: 600 V; Start-up voltage: 160 V; MPPT range: 200–850 V; Full-load MPPT range: 250–850 V; Battery type: Compatible high-voltage Li-ion system with BMS; Battery voltage: 120–700 V; Charge / discharge current: 50 / 50 A; Maximum charge / discharge power: 12 / 12 kW; Storage capacity: In kWh according to selected battery system; Battery-system power: According to actual voltage, BMS limit and inverter current; Battery communication: CAN / RS485; PV → battery efficiency: 98.31 %; Battery ↔ AC efficiency: 97.50 %; Grid connection: 3/N/PE; 380 / 400 V; Grid frequency: 50 / 60 Hz; Rated AC current at 380 /400 V: 18.2 / 17.3 A; Maximum AC input current at 380 /400 V: 27.3 / 26.0 A; AC input voltage: 304–437 / 320–460 V; AC input frequency: 45–55 / 55–65 Hz; Power factor: >0.99; 0.8 leading / lagging; THDi: <3 %; Operating modes: Self Use / Feed-in Priority / Off Grid / Peak Shaving; Grid charging: Allow Grid Charging setting for schedule or SOC recovery; Time scheduling: 6 charging and 6 discharging windows; Backup reserve: Adjustable reserved SOC; Default over-discharge SOC: 20 %; Default force-charge SOC: 10 %; Peak Shaving: Pmax + Peak SOC; Local control: SolisCloud APP / Bluetooth; Status LEDs: Battery / Power / WiFi / RS485 / Bluetooth; Bluetooth: BDR / EDR / BLE; 2400–2483.5 MHz; 10 dBm; App roles: Installer / Owner; Initial settings: Date, time, battery model, meter, grid code and work mode; Parallel system: 2–6 identical inverter models; Parallel-system batteries: Each inverter has its own battery and BMS connection; Parallel grid configuration: Balanced three-phase connection following manufacturer diagram; Parallel communication: P-B → P-A; shielded CAT5; ≤5 m; Parallel-system addresses: Master 1; Slave 2–6; Parallel Sync.

Parallel bus termination: At endpoints according to selected original diagram; Standard meter: Eastron SDM630MCT; Standard CTs: ESCT-TA16; 120 A / 40 mA; Metering above 3 parallel units: SDM630MCT V2 + ESCT-T50; 300 A / 5 A; BMS CAN RJ45: 4 CAN-H / 5 CAN-L; 3 m; Meter RJ45: 1 A / 2 B; 5 m; Eastron terminals: 13 B / 14 A; External Modbus RTU: RS485 RJ45: 5 A / 4 B; CT orientation: Arrow towards grid; DRM: Pins 5/6 closed: operation; open: shutdown within 5 s; Grid / Backup connectors: Separate grid and backup connectors; PV conductors: 4–6 mm²; recommended 4 mm²; PV stripping: 7 ±0.5 mm; Battery conductors: 8–10 mm²; recommended 10 mm² / 8 AWG; AC conductors per manual: 2.5–6 mm²; cable Ø14–17 mm; AC conductor stripping: 7 mm; AC terminals / nut: 0.8 ±0.1 / 2.5 ±0.5 Nm; Earth terminal: M4 / 2 Nm; Communication cover: 1.7–2 Nm; Communication glands: 6 mm; Ingress protection: IP66; Operating temperature: −25…+60 °C; Operating humidity: 0–100 % RH; Altitude: 4000 m; Cooling: Natural convection; Noise: <46.9 dB(A); Night consumption: <25 W; Dimensions W × H × D: 563 × 412 × 230 mm; Weight: 34.5 kg; Mounting: Vertical wall mounting, up to ±5°; Mounting clearances: 200 mm; Bracket hole spacing: 515 × 170 mm; Package — main parts: Inverter, backplate, manual, dust cover, Bluetooth antenna; Package — fasteners: 4 × M4 ×12; Package — metering: 1 meter, 3 CTs, 1 meter cable; Package — communication: 6 × RJ45; 1 × CAN cable; Package — power connectors: Grid 1; Backup 1; BAT 1; PV 4; Optional family protection: AFCI 2.0 according to selected family configuration; Estimated delivery: 2–3 days; Maximum PV efficiency: 97.85 %; European efficiency: 97.51 %; Surge protection included: DC Type II / AC Type II; Arc protection included: AFCI 1.0; Generator connection: Grid through ATS and 220 VAC/12 VDC status-signal supply; Generator — DI/DO pins: 1 +12 VDC / 3 GND; Generator — settings: Grid port power by: generator; Generator Charge; Gen Charge power; Generator — default charge start / stop SOC: 25 / 80 %; Heat pump — DI/DO pins: 5 S-A / 7 S-B; Heat pump — modes: Manual / Smart; Heat pump — default enable / disable SOC: 90 / 70 %; Heat pump — default enable / disable power: 2000 / −500 W; Heat pump — minimum runtime: 5–60 min; default 10 min; step 5 min; Heat pump — Smart logic: Enable when both SOC and export conditions hold; disable on either stop condition; AC coupling — meters: Grid 001; PV inverter 002; DRM — default S1–S4 power steps: 0 / 30 / 60 / 100 %; DRM mode2 — default S4 import limit: 4.2 kW; Quick Commission: Network Connection → Device Configuration → Create/Add Plant; Quick Commission — app: SolisCloud >V5.2.221; Try the new version; Quick Commission diagnostics: PV / Grid / Battery / Meter / Alarm.

Batterado — SOLIS-S6-EH3P12K-H-EU(21A)

Markdown — SOLIS-S6-EH3P12K-H-EU(21A)

Additional information

Weight 34,5 kg
Dimensions 23 × 56,3 × 41,2 cm

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

0
0
Your Cart
Your cart is emptyReturn to Shop