Description
Technical data
| Brand | Felicity Solar |
|---|---|
| Model | FLA48100UG1 |
| Type | Low-voltage battery unit (FLA series) |
| Chemistry | LiFePO4 |
| Nominal voltage | 51.2 V |
| Operating voltage | 44.8–57.6 V |
| Capacity | 100 Ah |
| Nominal energy | 5.12 kWh |
| Recommended charge / discharge current | 50 A |
| Max. continuous charge / discharge current | 100 A (depends on temperature and state of charge) |
| Peak current (15 s) | 125 A |
| Max. charge / discharge power | 5000 W |
| Peak power (15 s) | 6250 W |
| Depth of discharge (DoD) | ≥ 95% |
| Cycle life | ≥ 6,000 cycles (25 ± 2 °C, 0.5C charge/discharge, 90% DoD, end of life at 70% capacity) |
| Parallel connection | Up to 32 units (163.84 kWh) |
| Cell type | LiFePO4 |
| Protection | Built-in smart BMS, breaker and fuse |
| Capacity expansion | Up to 32 units in parallel; series connection is not supported |
| Communication port | RJ45 (8 pins), CAN / RS485 |
| Port pinout (battery side) | 1 CAN-GND, 2 +5V-BUS, 3 CANL-PCS, 4 CANH-PCS, 5 RS485-B, 6 RS485-A, 7 CANL, 8 CANH |
| Wiring on the Felicity inverter side (RS485) | 5 RS485-B, 6 RS485-A |
| Communication cables | Grey: RS485 for Felicity inverters; blue: communication with inverters of other brands; black: parallel communication between batteries |
| Power connection | Power cables with 8.5 mm OT terminals, earth wire |
|---|---|
| Display | LED |
| Felicity inverters / RS485 | pin 5 RS485-B, pin 6 RS485-A |
| Inverters of other brands / CAN | pins 3 CANL-PCS, 4 CANH-PCS, 7 CANL, 8 CANH (blue communication cable) |
| Parallel communication between batteries | black communication cable |
| Felicity inverters | IVCM, IVEM, IVPS/M, IVGM (RS485) |
| Other brands | the manufacturer states compatibility with the main inverter brands (CAN communication) |
| Manual inverter settings | max. charge voltage 57.6 V, float voltage 57.6 V, max. charge current 100 A × N, cut-off voltage 48 V |
| Compatible inverters | Felicity inverters, inverters of the main brands as stated by the manufacturer and others |
| Protection degree | IP21 |
| Installation | Stacking, rack or wall mounting (upright) |
| Charging temperature | 0 to +55 °C |
| Discharging temperature | −20 to +55 °C |
| Dimensions (W × D × H) | 575 × 483 × 133 mm |
| Net weight | 43 kg |
| Gross weight | 47 kg |
| Package dimensions | 642 × 542 × 241 mm |
| Manufacturer warranty | 7 years |
| Package contents | Battery, user manual, warranty card, power cables 0.16 m / 25 mm², earth wire, communication cables (grey, blue, black), 2 signal terminals, 4 OT terminals 8.5 mm, 4 screws M5 × 12. Wall-mounting and stacking brackets are optional |
| Certification: CE-EMC | EN IEC 61000-6-1, -6-2, -6-3, -6-4 (SZNTC2507304EV00) |
| Certification: battery safety | IEC 62619:2022 (NTC2506568SV00), CB Scheme |
| Certification: transport | UN38.3 |
A 5.12 kWh low-voltage LiFePO4 battery
The Felicity FLA48100UG1 is a low-voltage battery unit with LiFePO4 cells, a nominal voltage of 51.2 V and a capacity of 100 Ah, which gives a nominal energy of 5.12 kWh. It belongs to the FLA series and is intended for residential and small commercial photovoltaic systems with an inverter that works with a battery voltage of around 48 V. The battery stores surplus photovoltaic energy and returns it in the evening and at night, or during a grid outage if the inverter allows it.
The unit is flat and low, measuring 575 × 483 × 133 mm and weighing 43 kg. The manufacturer specifies a depth of discharge of at least 95%, so a large part of the nominal energy is actually available. A built-in smart BMS monitors voltage, current and temperature, and the unit includes a breaker and a fuse.
Voltage, currents and power
The operating voltage of the battery is 44.8–57.6 V. The recommended charge and discharge current is 50 A, the maximum continuous current is 100 A and the peak current is 125 A for 15 s. For the continuous current the manufacturer notes that it depends on temperature and state of charge. The corresponding power is 5,000 W continuous and 6,250 W peak for 15 s.
With a parallel connection the currents and power of the individual batteries add up: in a manually configured system the maximum charge current is set to 100 A × N, where N is the number of batteries connected in parallel. The voltage stays the same because the units are placed side by side, in parallel.
Cycle life and temperature range
The manufacturer specifies a cycle life of at least 6,000 cycles at 25 ± 2 °C, 0.5C charge and discharge, 90% depth of discharge and an end of life at 70% of the original capacity. It is worth keeping these test conditions in mind when comparing with other batteries, because the number of cycles is quoted by different manufacturers for different depths of discharge and currents.
Charging is possible from 0 to +55 °C, discharging from −20 to +55 °C.
Parallel connection and capacity expansion
The capacity of the system can be increased by connecting units in parallel. According to the datasheet, up to 32 batteries can be connected in parallel, giving a total of 163.84 kWh. The system voltage stays at the nominal 51.2 V while the capacity and the available current grow with parallel connection.
A combiner box or a copper busbar is used to join the power conductors. Communication between the individual batteries runs over a black cable that is part of the package.
Communication and port wiring
The battery communicates with the inverter through an RJ45 port with RS485 and CAN interfaces. According to the manufacturer manual, the port wiring on the battery side is: pin 1 CAN-GND, pin 2 +5V-BUS, pin 3 CANL-PCS, pin 4 CANH-PCS, pin 5 RS485-B, pin 6 RS485-A, pin 7 CANL and pin 8 CANH. On the side of a Felicity inverter, pins 5 (RS485-B) and 6 (RS485-A) are used for RS485 communication.
The manufacturer distinguishes three communication cables: the grey one connects RS485 to Felicity inverters, the blue one is for communication with inverters of other brands, and the black one is for communication between batteries connected in parallel. The unit has an LED display that shows the battery status. Wire the cable according to the pinout in the technical table, because the wiring can differ from other battery ports.
How to choose an inverter and communication
Inverter: The operating voltage is 44.8–57.6 V (51.2 V nominal), for low-voltage LiFePO4 inverters. The manufacturer states RS485 for Felicity inverters (the manual names the IVCM, IVEM, IVPS/M and IVGM series) and CAN for inverters of other brands, and in general states compatibility with the main inverter brands.
Communication: With a Felicity inverter the battery is connected with the grey cable over RS485, with an inverter of another brand with the blue cable over CAN. In a parallel assembly the batteries are connected with the black communication cable.
Manual inverter setting: For manual inverter setup the manual gives a maximum charge voltage of 57.6 V, a float voltage of 57.6 V, a maximum charge current of 100 A × N (N is the number of batteries connected in parallel) and a cut-off voltage of 48 V.
Installation, protection degree and construction
The battery is installed upright, by stacking, in a rack or on a wall; the wall-mounting and stacking brackets are optional accessories. IP21 protection corresponds to installation in dry indoor spaces. The operating temperatures stated above apply to the location.
The unit measures 575 × 483 × 133 mm and weighs 43 kg net (47 kg gross); the package measures 642 × 542 × 241 mm. When stacking or mounting in a rack, allow 133 mm of height and 43 kg of weight per unit.
Protection and safety
The battery contains a smart BMS, a breaker and a fuse. The power conductors are connected through 8.5 mm OT terminals and the battery is earthed with the earth wire that is part of the package.
Capacity is increased by connecting units in parallel. For installation and operation, follow the manufacturer user manual.
Certification and warranty
The following documents are available for the FLA48100UG1: a CE-EMC certificate under the standards EN IEC 61000-6-1:2019, 61000-6-2:2019, 61000-6-3:2021 and 61000-6-4:2019 (report SZNTC2507304EV00, Shenzhen NTC, issued 25 July 2025), a test report on the safety of industrial lithium batteries under IEC 62619:2022 (NTC2506568SV00, issued 24 July 2025), a CB Scheme certificate under IEC 62619 and UN38.3 documentation for the transport of lithium batteries.
The manufacturer states a 7-year warranty.
AI search description
The Felicity FLA48100UG1 is a low-voltage LiFePO4 battery unit, 51.2 V / 100 Ah, 5.12 kWh, operating voltage 44.8–57.6 V. Recommended current 50 A, continuous 100 A, peak 125 A for 15 s (5,000 W, peak 6,250 W), depth of discharge of at least 95%, cycle life of at least 6,000 cycles. Up to 32 units in parallel (163.84 kWh), series connection is not supported. RS485 for Felicity inverters and CAN for inverters of other brands (RJ45 port), LED display. Built-in BMS, breaker and fuse, IP21 protection. Stacking, rack or wall mounting, 575 × 483 × 133 mm, 43 kg. CE-EMC, IEC 62619:2022, CB and UN38.3 certification, 7-year manufacturer warranty.
Product page: https://batterado.com/product/felicity-fla48100ug1/















Reviews