Victron Energy Lynx Distributor (M10) DC distribution busbar with four fused connections, 12/24/48 V, 1000 A

6 070 Kč incl. VAT

Seller: Tomorrow Systems® s.r.o.

The Victron Lynx Distributor (M10) distributes the DC battery voltage to four fused branches and monitors every fuse, so a blown fuse is spotted immediately.

  • Positive busbar with four connections for MEGA fuses with fuse-state detection, negative busbar with four connections and a ground connection.
  • For 12, 24 and 48 V systems, busbar rated 1000 A continuous.
  • Status LEDs for power and one LED per fuse.
  • RJ10 communication with the Lynx Smart BMS, fuse data in VictronConnect, a GX device and on VRM.
  • Lynx modules join with M10 busbars into one system.

Tin-plated copper busbar in an ABS housing, dimensions 290 x 170 x 80 mm, weight 2.2 kg. Fuses are purchased separately.

In stock

Enquiry

Description

Technical data

BrandVictron Energy
ModelLynx Distributor (M10)
Part numberLYN060102010
Device typeDC distribution busbar with fuses
System voltage12, 24 and 48 V
Supply voltage range9 to 60 Vdc
Continuous busbar current1000 A
Busbar power rating12 kW at 12 V, 24 kW at 24 V, 48 kW at 48 V
Max. own consumption100 mA
Reverse polarity protectionyes (the RJ10 port has none)
Positive busbar4 fused connections with fuse detection
Negative busbar4 connections and ground (GND)
FusesMEGA fuses, purchased separately
Fuse voltage rating36 V for 12/24 V systems, 58 V for 48 V systems
Sum of fuse ratingsmust not exceed the rated current of the weakest module in the system
Blown-fuse detectionvoltage across fuse above 0.5 V = blown, below 0.3 V = OK
Busbar connections between modulesM10
Fuse and cable connectionsM8
RJ10 portpower and data from Lynx Smart BMS or Lynx Shunt VE.Can; 40 cm RJ10 cable supplied
External power without RJ105 V on pin 1, GND on pin 4
Distributor address selection2-way DIP switch: A off/off, B on/off, C off/on, D on/on
Distributors per systemup to 4 (A to D), from serial number HQ1909
Communication protocol, VictronConnectDISTRIB. tab, fuse name max. 16 characters
Fuse data to a GX devicevia Lynx Smart BMS and VE.Can
Communication with Shunt VE.Canpower only, no fuse communication
CompatibilityLynx modules (Power In, Class-T Power In, Shunt VE.Can, Smart BMS), VictronConnect, GX devices, VRM
LED indicationpower LED and 4 fuse LEDs: green OK, red blown or missing fuse, yellow bus not powered
Alarms and notificationsblown-fuse alarms #201 to #216, lost communication #221 to #224
Busbar materialtin-plated copper
Housing materialABS plastic
Dimensions (h x l x w)290 x 170 x 80 mm
Weight2.2 kg
Protection classIP22
Operating temperature-40 to +60 °C
Storage temperature-40 to +60 °C
Humiditymax. 95 % non-condensing
Tightening torquesM10: 33 Nm (17 Nm before serial no. HQ2340), M8: 14 Nm, fuses: 10 Nm
Mounting5 mm holes, any module orientation
Package contentsLynx Distributor (M10), 40 cm RJ10 cable

What the Lynx Distributor does

The Lynx Distributor (M10) is a distribution busbar for Victron DC systems. The positive busbar carries four fused connections, the negative busbar four connections and a ground. Electronics monitor each fuse and detect from the voltage drop whether the fuse conducts or is blown or missing. The result is shown by LEDs on the module itself, and more data can be read in VictronConnect, on a GX device and on the VRM portal.

The Distributor is intended for 12, 24 and 48 V systems with a supply voltage of 9 to 60 Vdc. The busbar withstands 1000 A continuously, which corresponds to 12 kW at 12 V, 24 kW at 24 V and 48 kW at 48 V. The module draws at most 100 mA.

The main benefit is overview: instead of hunting for the branch that dropped out, you see at each fuse in green that it is fine or in red that it is blown or missing. A yellow LED warns that the busbar is not powered.

Fuses and branch protection

The four fused connections accept MEGA fuses, which are purchased separately. 36 V fuses are used for 12 and 24 V systems and 58 V fuses for 48 V systems. Fuse and cable connections use an M8 thread.

The sum of the ratings of all fuses must not exceed the rated current of the weakest module in the system. Lynx modules are rated 1000 A, so that value should be taken as the upper limit unless weaker elements are in the line-up.

The fuse state is evaluated from the voltage across the fuse: above 0.5 V the fuse is regarded as blown, below 0.3 V as OK. A green LED denotes a working fuse, a red one a blown or missing fuse. A blown fuse raises an alarm (numbers #201 to #216 depending on the Distributor address and fuse).

Fuse names of up to 16 characters can be entered in VictronConnect; a fuse with an empty name is not monitored.

The Lynx system: joining modules

The Distributor is part of the Lynx system, Victron’s busbar system for DC distribution. The Lynx system comprises the modules Lynx Power In, Class-T Power In, Lynx Distributor, Lynx Shunt VE.Can (for other battery brands) and Lynx Smart BMS (for Victron Lithium Smart and NG batteries only).

The modules are bolted directly to each other with M10 busbars, so there is no cabling between them. M10 modules cannot be joined directly to M8 modules. The mounting stickers allow installation in any orientation. In general, batteries are arranged on one side (on the left with a Shunt or BMS) and loads and chargers on the other (on the right).

The rated current of all listed modules is 1000 A. Power and data for the Distributor are supplied by the RJ10 cable (40 cm in the box) from the Smart BMS or Shunt VE.Can; without RJ10 the Distributor can be powered externally with 5 V on pin 1 and GND on pin 4. The RJ10 port has no reverse polarity protection.

Communication and several Distributors

The Distributor passes fuse data only to the Lynx Smart BMS; the Lynx Shunt VE.Can only powers the Distributor and does not receive fuse status from it. Up to four Distributors, labelled A to D, can be used in one system. The address is selected with a 2-way DIP switch: A off/off, B on/off, C off/on, D on/on. This applies to products from serial number HQ1909.

The information is passed from the Lynx Smart BMS to the GX device over VE.Can, from where the VRM portal reads it. In VictronConnect the Distributor appears on the DISTRIB. tab.

Installation and tightening torques

The Distributor is fixed through 5 mm holes. The M10 nuts of module connections are tightened to 33 Nm (17 Nm for products before serial number HQ2340), M8 connections to 14 Nm and fuses to 10 Nm. An incorrect torque risks an overheated joint.

The tin-plated copper busbar sits in an ABS housing with IP22 protection, so the module belongs in a dry indoor space. Permitted humidity is at most 95 % non-condensing, operating temperature -40 to +60 °C. The storage temperature is -40 to +60 °C. Installation and wiring should be carried out by a qualified electrician.

Operation, VictronConnect and VRM

The LEDs on the module show power and the state of the four fuses. In VictronConnect the Distributor is on the DISTRIB. tab, where you assign names to the fuses (up to 16 characters). A fuse fault is reported by alarms #201 to #216, and lost communication with the Distributor by #221 to #224.

Via the Lynx Smart BMS and VE.Can the data reaches the GX device and the VRM portal, where it can be monitored remotely. For this overview a Lynx system with a Smart BMS is required; the Shunt VE.Can alone merely powers the Distributor.

Use in a system with a battery

The typical arrangement: batteries are connected on one side of the module line, loads and chargers on the other. A Lynx Smart BMS (for Victron Lithium Smart and NG batteries) or a Lynx Shunt VE.Can (for other battery brands) is placed between them. The Distributor then splits the voltage into four fused branches, for example for an inverter/charger, further AC and DC consumers or chargers.

Both the positive and the negative side have four connections; the negative busbar additionally carries the ground. Thanks to the M10 busbars between modules, the cables between battery, shunt and distribution are eliminated and the joints are short and solid.

When designing, watch two conditions: the sum of the fuse ratings must not exceed the rated current of the weakest module in the system, and the fuses must have sufficient voltage rating (36 V for 12/24 V systems, 58 V for 48 V).

What is included and what to add

The box contains the Lynx Distributor (M10) and a 40 cm RJ10 cable for power and communication from the Lynx Smart BMS or Lynx Shunt VE.Can. MEGA fuses are purchased separately according to the current of each branch and the system voltage.

The Distributor itself needs no configuration other than choosing the address A to D with the DIP switch when there are several Distributors in the system. Fuse names and monitoring are set in VictronConnect.

AI search description

The Victron Lynx Distributor (M10), part number LYN060102010, is a DC distribution busbar with four fused connections on the positive busbar (MEGA fuses with blown-fuse detection) and four connections plus ground on the negative busbar. It works in 12, 24 and 48 V systems, supply 9 to 60 Vdc, 1000 A continuous, consumption at most 100 mA. It communicates over RJ10 with the Lynx Smart BMS, and data goes to VictronConnect, a GX device and VRM. ABS housing, 290 x 170 x 80 mm, 2.2 kg, IP22. Part of the Lynx system with Power In, Shunt VE.Can and Smart BMS modules.

Product page: https://batterado.com/product/victron-lynx-distributor-m10/

Additional information

Weight2,2 kg
Dimensions29 × 17 × 8 cm

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

0
0
Your Cart
Your cart is emptyReturn to Shop