{"id":61053,"date":"2026-11-27T12:24:55","date_gmt":"2026-11-27T10:24:55","guid":{"rendered":"https:\/\/batterado.com\/?post_type=product&#038;p=61053"},"modified":"2026-11-27T12:24:55","modified_gmt":"2026-11-27T10:24:55","slug":"deye-lsw-5","status":"publish","type":"product","link":"https:\/\/batterado.com\/en\/product\/deye-lsw-5\/","title":{"rendered":"Deye LSW-5 Wi-Fi stick logger for Deye inverters, RS232, Deye \/ Solarman cloud"},"content":{"rendered":"<table>\n<tbody>\n<tr>\n<th>Brand<\/th>\n<td>Deye<\/td>\n<\/tr>\n<tr>\n<th>Model<\/th>\n<td>LSW-5 (LSW-5A5253)<\/td>\n<\/tr>\n<tr>\n<th>Type<\/th>\n<td>Wi-Fi stick logger<\/td>\n<\/tr>\n<tr>\n<th>Remote communication<\/th>\n<td>Wi-Fi (integrated PCB antenna)<\/td>\n<\/tr>\n<tr>\n<th>Working frequency<\/th>\n<td>2.412\u20132.472 GHz<\/td>\n<\/tr>\n<tr>\n<th>Data interface<\/th>\n<td>RS232<\/td>\n<\/tr>\n<tr>\n<th>Working voltage<\/th>\n<td>DC 5\u201312 V<\/td>\n<\/tr>\n<tr>\n<th>Working power<\/th>\n<td>1.5 W<\/td>\n<\/tr>\n<tr>\n<th>Memory<\/th>\n<td>8 MB flash<\/td>\n<\/tr>\n<tr>\n<th>Serial rate<\/th>\n<td>9,600 bps (adjustable 1,200\u2013115,200 bps)<\/td>\n<\/tr>\n<tr>\n<th>Data acquisition interval<\/th>\n<td>default 5 minutes<\/td>\n<\/tr>\n<tr>\n<th>Configuration<\/th>\n<td>AT+ commands, local web page, remote server, Bluetooth<\/td>\n<\/tr>\n<tr>\n<th>Firmware update<\/th>\n<td>Local web page or remote<\/td>\n<\/tr>\n<tr>\n<th>Other functions<\/th>\n<td>Real-time control, breakpoint and data resume<\/td>\n<\/tr>\n<tr>\n<th>LED indicators<\/th>\n<td>NET, COM, READY<\/td>\n<\/tr>\n<tr>\n<th>Operating temperature<\/th>\n<td>\u221230 to +70 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th>Operating humidity<\/th>\n<td>10\u201390 % RH, non-condensing<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Wireless inverter monitoring<\/h2>\n<p>The LSW-5 stick logger reads data from the inverter over an RS232 interface and sends it over Wi-Fi to the Deye and Solarman cloud. It plugs into the inverter communication port and is powered from it, so you only connect it and set up the network. Power consumption is just 1.5 W and the antenna is integrated on the board.<\/p>\n<h2>Memory and data collection<\/h2>\n<p>Eight megabytes of flash memory, breakpoint resume and data resume protect the operating record. The default acquisition interval is 5 minutes and the serial rate is 9,600 bps, adjustable up to 115,200 bps. The NET, COM and READY LEDs show the router connection, the inverter connection and operation.<\/p>\n<h2>Setup and updates<\/h2>\n<p>The logger is configured with AT+ commands, through a local web page, a remote server or Bluetooth. Firmware is updated locally and remotely. It supports real-time control of the inverter.<\/p>\n<h2>Compatibility<\/h2>\n<p>Likely compatible: Deye inverters with a communication port for a stick logger, and others. An operating temperature of \u221230 to +70 \u00b0C and 10\u201390 % RH humidity suit installation at the inverter.<\/p>\n<section class=\"tomo-ai-search-profile\">\n<h2>AI search description<\/h2>\n<p>The Deye LSW-5 is a Wi-Fi stick logger that collects inverter data over RS232 and sends it to the Deye and Solarman cloud. Powered at DC 5-12 V from the inverter, 1.5 W consumption, 8 MB flash memory, Wi-Fi 2.412-2.472 GHz with an integrated antenna. Default acquisition interval 5 minutes, serial rate 9,600 bps (1,200-115,200 bps). Configuration by AT+ commands, web page or Bluetooth, firmware update locally and remotely. NET, COM, READY LEDs. Operating temperature -30 to +70 C, humidity 10-90 % RH. Likely compatible with Deye inverters.<\/p>\n<p>Product page: <a href=\"https:\/\/batterado.com\/product\/deye-lsw-5\/\">https:\/\/batterado.com\/product\/deye-lsw-5\/<\/a><\/p>\n<\/section>\n","protected":false},"excerpt":{"rendered":"<p>The Deye LSW-5 is a Wi-Fi stick logger that carries data from the inverter to the Deye and Solarman cloud without a single extra cable. It plugs into the inverter communication port, is powered from it at DC 5-12 V and uses only 1.5 W. Wi-Fi works in the 2.412-2.472 GHz band with an antenna integrated on the board. It reads data over the RS232 interface at a default interval of 5 minutes, and the serial rate is 9,600 bps, adjustable up to 115,200 bps. Eight megabytes of flash memory with breakpoint resume and data resume protect the operating record. The NET, COM and READY LEDs show the router connection, the inverter connection and operation. Configuration is done with AT+ commands, a web page or Bluetooth, and firmware is updated locally and remotely. Operating temperature -30 to +70 C. Likely compatible with Deye inverters that have a stick logger port.<\/p>\n","protected":false},"featured_media":61054,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[3411],"product_cat":[3615,4047],"product_tag":[4026,3782],"class_list":["post-61053","product","type-product","status-publish","has-post-thumbnail","product_brand-deye","product_cat-photovoltaic-accessories","product_cat-monitoring-dataloggers","product_tag-lsw-5","product_tag-deye-inverter-accessory","first","instock","taxable","shipping-taxable","purchasable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product\/61053","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/comments?post=61053"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/media\/61054"}],"wp:attachment":[{"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/media?parent=61053"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product_brand?post=61053"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product_cat?post=61053"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product_tag?post=61053"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}