{"id":61031,"date":"2026-11-27T12:24:00","date_gmt":"2026-11-27T10:24:00","guid":{"rendered":"https:\/\/batterado.com\/?post_type=product&#038;p=61031"},"modified":"2026-11-28T15:32:56","modified_gmt":"2026-11-28T13:32:56","slug":"eastron-sdm630-mct","status":"publish","type":"product","link":"https:\/\/batterado.com\/en\/product\/eastron-sdm630-mct\/","title":{"rendered":"Eastron SDM630-MCT Three-phase DIN-rail energy meter for external CTs, Modbus RTU"},"content":{"rendered":"<h2>Technical specifications<\/h2>\n<div class=\"wt-tech-grid\">\n<table>\n<tbody>\n<tr class=\"wt-tech-group\">\n<th colspan=\"2\">Identity and measurement<\/th>\n<\/tr>\n<tr>\n<th>Brand<\/th>\n<td>Eastron<\/td>\n<\/tr>\n<tr>\n<th>Model<\/th>\n<td>SDM630MCT 40 mA (three-phase, CT-connected, Modbus RTU)<\/td>\n<\/tr>\n<tr>\n<th>Device type<\/th>\n<td>Three-phase energy meter for CT-connected metering, DIN rail<\/td>\n<\/tr>\n<tr>\n<th>Wiring systems<\/th>\n<td>1P2W, 3P3W, 3P4W (selectable)<\/td>\n<\/tr>\n<tr>\n<th>Measured quantities<\/th>\n<td>Voltage, current, frequency, power factor, active\/reactive\/apparent power per phase and total, active and reactive energy, THD<\/td>\n<\/tr>\n<tr>\n<th>Energy direction<\/th>\n<td>Import and export, selectable total<\/td>\n<\/tr>\n<tr>\n<th>Accuracy class<\/th>\n<td>Class 1 (IEC 62053-21)<\/td>\n<\/tr>\n<tr>\n<th>Harmonics<\/th>\n<td>Voltage and current THD up to the 31st harmonic<\/td>\n<\/tr>\n<tr>\n<th>Maximum demand<\/th>\n<td>yes, interval 5 \/ 8 \/ 10 \/ 15 \/ 20 \/ 30 \/ 60 min or off<\/td>\n<\/tr>\n<tr class=\"wt-tech-group\">\n<th colspan=\"2\">Electrical parameters<\/th>\n<\/tr>\n<tr>\n<th>Phase-to-neutral voltage<\/th>\n<td>100\u2013289 V AC<\/td>\n<\/tr>\n<tr>\n<th>Phase-to-phase voltage<\/th>\n<td>173\u2013500 V AC<\/td>\n<\/tr>\n<tr>\n<th>Current input<\/th>\n<td>CT with 40 mA output<\/td>\n<\/tr>\n<tr>\n<th>CT ratio<\/th>\n<td>primary current adjustable 5\u20139999 A<\/td>\n<\/tr>\n<tr>\n<th>Current measuring range<\/th>\n<td>0.2 % Ib to Imax<\/td>\n<\/tr>\n<tr>\n<th>Overload withstand<\/th>\n<td>20 \u00d7 Imax for 0.5 s<\/td>\n<\/tr>\n<tr>\n<th>Frequency<\/th>\n<td>50\/60 Hz<\/td>\n<\/tr>\n<tr>\n<th>Auxiliary supply<\/th>\n<td>85\u2013275 V AC or 120\u2013380 V DC<\/td>\n<\/tr>\n<tr>\n<th>Internal consumption<\/th>\n<td>2 W \/ 10 VA<\/td>\n<\/tr>\n<tr>\n<th>Energy counter<\/th>\n<td>up to 9,999,999.9 kWh<\/td>\n<\/tr>\n<tr class=\"wt-tech-group\">\n<th colspan=\"2\">Communication and integration<\/th>\n<\/tr>\n<tr>\n<th>RS485<\/th>\n<td>yes, one port<\/td>\n<\/tr>\n<tr>\n<th>Modbus RTU<\/th>\n<td>yes, slave mode<\/td>\n<\/tr>\n<tr>\n<th>Baud rate<\/th>\n<td>2400, 4800, 9600, 19200, 38400 baud<\/td>\n<\/tr>\n<tr>\n<th>Parity and stop bits<\/th>\n<td>none (default) \/ odd \/ even; 1 or 2 stop bits (2 only with no parity)<\/td>\n<\/tr>\n<tr>\n<th>Modbus address<\/th>\n<td>001\u2013247<\/td>\n<\/tr>\n<tr>\n<th>Data format<\/th>\n<td>IEEE 754, 32-bit float; measurements in input registers (function 04)<\/td>\n<\/tr>\n<tr>\n<th>Bus capacity<\/th>\n<td>up to 64 devices per bus, up to 1000 m<\/td>\n<\/tr>\n<tr>\n<th>Pulse outputs<\/th>\n<td>2 pulse outputs, 3200 imp\/kWh, pulse width 90 ms<\/td>\n<\/tr>\n<tr>\n<th>Wi-Fi<\/th>\n<td>no<\/td>\n<\/tr>\n<tr>\n<th>Bluetooth<\/th>\n<td>no<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<th>Zigbee<\/th>\n<td>no<\/td>\n<\/tr>\n<tr>\n<th>LoRa<\/th>\n<td>no<\/td>\n<\/tr>\n<tr>\n<th>Ethernet<\/th>\n<td>no<\/td>\n<\/tr>\n<tr>\n<th>Mobile network 4G<\/th>\n<td>no<\/td>\n<\/tr>\n<tr>\n<th>Local API<\/th>\n<td>yes, Modbus RTU over RS485<\/td>\n<\/tr>\n<tr>\n<th>Cloud API<\/th>\n<td>via the system the meter is connected to (inverter and its cloud)<\/td>\n<\/tr>\n<tr>\n<th>App<\/th>\n<td>meter data in the app of the connected inverter; settings on the meter display<\/td>\n<\/tr>\n<tr>\n<th>Modbus TCP<\/th>\n<td>via an RS485 \u2194 Modbus TCP gateway<\/td>\n<\/tr>\n<tr>\n<th>MQTT<\/th>\n<td>via an RS485 \u2194 MQTT converter<\/td>\n<\/tr>\n<tr>\n<th>Home Assistant<\/th>\n<td>yes, Modbus integration via an RS485 converter<\/td>\n<\/tr>\n<tr>\n<th>Modbus RTU master<\/th>\n<td>inverter, RS485\/TCP gateway, PLC<\/td>\n<\/tr>\n<tr class=\"wt-tech-group\">\n<th colspan=\"2\">Compatibility<\/th>\n<\/tr>\n<tr>\n<th>Deye<\/th>\n<td>Deye hybrid inverters (SDM630MCT 40 mA and 1A\/5A)<\/td>\n<\/tr>\n<tr>\n<th>Growatt<\/th>\n<td>Growatt WIT (SDM630MCT on the supported meter list)<\/td>\n<\/tr>\n<tr>\n<th>Victron<\/th>\n<td>Victron GX via the open-source dbus-modbus-client driver (SDM630 family)<\/td>\n<\/tr>\n<tr>\n<th>Other systems<\/th>\n<td>any Modbus RTU master using the Eastron SDM630 register map<\/td>\n<\/tr>\n<tr class=\"wt-tech-group\">\n<th colspan=\"2\">Construction and environment<\/th>\n<\/tr>\n<tr>\n<th>Dimensions (W \u00d7 H \u00d7 D)<\/th>\n<td>72 \u00d7 94.5 \u00d7 65 mm (4 modules)<\/td>\n<\/tr>\n<tr>\n<th>Mounting<\/th>\n<td>35 mm DIN rail<\/td>\n<\/tr>\n<tr>\n<th>Terminals<\/th>\n<td>screw terminals for wires up to 2.5 mm\u00b2 (current, voltage, RS485)<\/td>\n<\/tr>\n<tr>\n<th>Ingress protection<\/th>\n<td>IP51 (indoor)<\/td>\n<\/tr>\n<tr>\n<th>Operating temperature<\/th>\n<td>\u221225 to +55 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th>Storage temperature<\/th>\n<td>\u221240 to +70 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th>Humidity<\/th>\n<td>0\u201390 %, non-condensing<\/td>\n<\/tr>\n<tr>\n<th>Altitude<\/th>\n<td>up to 2,000 m<\/td>\n<\/tr>\n<tr>\n<th>Overvoltage category<\/th>\n<td>CAT III<\/td>\n<\/tr>\n<tr>\n<th>Mechanical and EMC environment<\/th>\n<td>M1, E2<\/td>\n<\/tr>\n<tr>\n<th>Setup and protection<\/th>\n<td>setup from the display, password (default 1000)<\/td>\n<\/tr>\n<tr class=\"wt-tech-group\">\n<th colspan=\"2\">Standards and package<\/th>\n<\/tr>\n<tr>\n<th>Standards<\/th>\n<td>IEC 62053-21, EN 55022<\/td>\n<\/tr>\n<tr>\n<th>Package contents<\/th>\n<td>Eastron SDM630MCT energy meter, 1 pc<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2>Three-phase metering through current transformers<\/h2>\n<p>The Eastron SDM630-MCT 40 mA is designed for metering through external current transformers with a 40 mA output. The input adapts to the size of the installation by setting the CT primary current from 5 to 9999 A, so the same meter serves house connections and large distribution boards alike.<\/p>\n<p>The device works in 1P2W, 3P3W and 3P4W wiring and shows values per phase and in total. Phase-to-neutral voltage is handled from 100\u2013289 V AC, phase-to-phase from 173\u2013500 V AC. The current range starts at 0.2 % of the basic current and ends at Imax; a short overload of 20 times Imax for 0.5 s is part of the specification.<\/p>\n<p>A frequency of 50\/60 Hz and a supply of 85\u2013275 V AC or 120\u2013380 V DC allow use in different networks without modification. Internal consumption is 2 W \/ 10 VA.<\/p>\n<h2>Class 1 accuracy and grid analysis<\/h2>\n<p>Active energy is measured with class 1 accuracy under IEC 62053-21. The device measures in both import and export directions and the displayed total can be selected as needed, so it suits monitoring of consumption, feed-in or both at once.<\/p>\n<p>Analysis includes voltage and current THD up to the 31st harmonic and a maximum demand function with a selectable interval of 5, 8, 10, 15, 20, 30 or 60 minutes. The energy counter holds values up to 9,999,999.9 kWh, so the readings last for the whole life of the installation.<\/p>\n<p>The environment matches mechanical class M1 and electromagnetic class E2, and the overvoltage category is CAT III. The meter is therefore ready for switchgear at the connection point.<\/p>\n<h2>Measured quantities and display<\/h2>\n<p>The Eastron SDM630-MCT measures voltage, current, frequency, power factor, active, reactive and apparent power per phase and in total, plus active and reactive energy. Values appear on a clear display and settings are made directly on the device with buttons, protected by a password (default 1000).<\/p>\n<ul>\n<li><strong>Instantaneous values:<\/strong> voltage, current, frequency, power factor, power per phase and in total.<\/li>\n<li><strong>Energy:<\/strong> active and reactive, import, export and total.<\/li>\n<li><strong>Grid quality:<\/strong> voltage and current THD up to the 31st harmonic.<\/li>\n<li><strong>Demand:<\/strong> maximum demand with selectable interval.<\/li>\n<\/ul>\n<h2>RS485 and Modbus RTU communication<\/h2>\n<p>The device has one RS485 port with the Modbus RTU protocol in slave mode. Choose the baud rate from 2400, 4800, 9600, 19200 and 38400, the parity none (default), odd or even, 1 or 2 stop bits (two with no parity) and an address in the range 001\u2013247. Up to 64 devices can share one bus over a line of up to 1000 m.<\/p>\n<p>Values are transferred as 32-bit floating-point numbers according to IEEE 754. Measurements are read with function 04 from the input registers, for example phase 1 voltage at address 0x0000, phase 1 current at 0x0006 and phase 1 active power at 0x000C; the complete map is in the SDM630MCT protocol document. Communication runs exclusively over the wired RS485 line, with no Wi-Fi, Bluetooth, Zigbee, LoRa, Ethernet or cellular module involved, so it is robust against interference and suits switchgear.<\/p>\n<h2>Pulse outputs<\/h2>\n<p>Two pulse outputs deliver 3200 impulses per kWh with a pulse width of 90 ms. They suit counters, PLCs and gateway inputs where the energy is evaluated separately, or as a backup alongside Modbus communication.<\/p>\n<h2>Use with inverters and in photovoltaics<\/h2>\n<p>The Eastron SDM630-MCT 40 mA is used as a meter at the connection point of three-phase photovoltaic systems with storage. From its data the inverter knows the draw from the distribution grid and the feed-in to it, and uses this to manage battery charging and discharging, zero export and export limiting.<\/p>\n<p>The Deye document on Eastron meters lists the SDM630MCT in 40 mA and 1A\/5A variants for Deye inverters. Growatt includes the SDM630MCT on its supported meter list for the WIT series. For Victron GX an open-source dbus-modbus-client driver exists for the SDM630 family, which shows the meter in the Victron system.<\/p>\n<p>The meter also serves for sub-metering three-phase chargers, heat pumps and production lines.<\/p>\n<h2>DIN rail mounting and environment<\/h2>\n<p>The housing measuring 72 \u00d7 94.5 \u00d7 65 mm (four modules) clips onto a 35 mm rail. Screw terminals take wires up to 2.5 mm\u00b2 for current, voltage and communication inputs. Protection rating IP51 is intended for indoor installation in a distribution board.<\/p>\n<p>The meter operates from \u221225 to +55 \u00b0C, can be kept from \u221240 to +70 \u00b0C, humidity up to 90 % without condensation and altitude up to 2000 m. After wiring, set the network type, CT ratio and RS485 parameters in the menu to match the inverter or gateway.<\/p>\n<h2>Integration into monitoring and Home Assistant<\/h2>\n<p>The SDM630 family registers are supported by a large number of tools. Through an RS485\/USB or RS485\/TCP converter they can be read in Home Assistant, Node-RED, scripts and control systems, and the values published onwards over MQTT.<\/p>\n<p>The interface is local, so metering works without any cloud or registration. Data stays in the home network and the response is immediate, which helps with zero-export control and quick reaction to changes in consumption.<\/p>\n<h2>Setup from the display and commissioning<\/h2>\n<p>All configuration is done directly on the device using the buttons, with no computer or app. In the menu you select the network wiring type (1P2W, 3P3W or 3P4W), the primary current of the current transformer, the RS485 parameters and the maximum demand interval. Access to the settings is protected by a password whose default value is 1000 and which can be changed.<\/p>\n<p>For commissioning it is enough to connect the voltage inputs, pass the phase conductors through the 40 mA current transformers, enter their primary current and choose a Modbus address and speed matching the inverter. After that the inverter or gateway starts reading all measured quantities, and the meter acts as a permanent source of energy-flow data at the connection point.<\/p>\n<h2>Package contents<\/h2>\n<p>The package contains the Eastron SDM630MCT energy meter. 40 mA current transformers, RS485 converters and shielded cable are chosen to suit the planned installation.<\/p>\n<h2>Downloads<\/h2>\n<ul>\n<li><a href=\"\/wp-content\/themes\/wodatherm\/assets\/documents\/products\/eastron-sdm630-mct-en.md\">Product overview Markdown<\/a><\/li>\n<\/ul>\n<section class=\"tomo-ai-search-profile\" data-ai-profile=\"61031\">\n<h2>AI search description<\/h2>\n<p>The Eastron SDM630-MCT 40 mA is a three-phase energy meter for metering through 40 mA current transformers with an adjustable primary current of 5\u20139999 A, accuracy class 1 (IEC 62053-21). It supports 1P2W, 3P3W and 3P4W wiring and measures voltage, current, power, power factor, frequency, THD up to the 31st harmonic and import and export energy. It communicates over RS485 using Modbus RTU (2400\u201338400 baud, address 001\u2013247, IEEE 754 float) and has two pulse outputs of 3200 imp\/kWh. 35 mm DIN rail, 72 \u00d7 94.5 \u00d7 65 mm, IP51. Documented with Deye, Growatt WIT and Victron GX. Up to 64 devices can share one RS485 bus over up to 1000 m, setup is done from the display, and the data can be brought into Home Assistant through an RS485 converter.<\/p>\n<p>Product page: <a href=\"https:\/\/batterado.com\/en\/product\/eastron-sdm630-mct\/\">https:\/\/batterado.com\/en\/product\/eastron-sdm630-mct\/<\/a><\/p>\n<\/section>\n","protected":false},"excerpt":{"rendered":"<p><strong>A three-phase energy meter for CT-connected metering with 40 mA transformers, passing all grid quantities to the inverter or control system over RS485.<\/strong> The Eastron SDM630-MCT covers 1P2W, 3P3W and 3P4W wiring and measures voltage, current, power, power factor, frequency and THD with class 1 accuracy.<\/p>\n<p>The current transformer ratio is set from 5 to 9999 A, so the same device serves a small distribution board and a large connection point. Modbus RTU at 2400\u201338400 baud with address 001\u2013247 works with Deye and Growatt inverters, RS485\/TCP gateways and PLCs, while two pulse outputs of 3200 imp\/kWh complete the energy evaluation.<\/p>\n<p>The 72 \u00d7 94.5 \u00d7 65 mm housing clips onto a 35 mm DIN rail, the 85\u2013275 V AC or 120\u2013380 V DC supply suits common switchgear, and the meter operates from \u221225 to +55 \u00b0C. Import and export metering, maximum demand and harmonics up to the 31st order make it a complete grid analyser for photovoltaics, batteries and sub-metering.<\/p>\n","protected":false},"featured_media":61098,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[4044],"product_cat":[4046,3615],"product_tag":[4017,3807,3782],"class_list":["post-61031","product","type-product","status-publish","has-post-thumbnail","product_brand-eastron","product_cat-energy-meters","product_cat-photovoltaic-accessories","product_tag-eastron-sdm-630-mct-etl","product_tag-rs485","product_tag-deye-inverter-accessory","first","instock","taxable","shipping-taxable","purchasable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product\/61031","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/comments?post=61031"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/media\/61098"}],"wp:attachment":[{"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/media?parent=61031"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product_brand?post=61031"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product_cat?post=61031"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product_tag?post=61031"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}