{"id":61030,"date":"2026-11-27T12:23:59","date_gmt":"2026-11-27T10:23:59","guid":{"rendered":"https:\/\/batterado.com\/?post_type=product&#038;p=61030"},"modified":"2026-11-28T15:32:27","modified_gmt":"2026-11-28T13:32:27","slug":"eastron-sdm230-modbus","status":"publish","type":"product","link":"https:\/\/batterado.com\/en\/product\/eastron-sdm230-modbus\/","title":{"rendered":"Eastron SDM230-Modbus Single-phase energy meter 100 A with MID certification, RS485"},"content":{"rendered":"<h2>Technical specifications<\/h2>\n<div class=\"wt-tech-grid\">\n<table>\n<tbody>\n<tr class=\"wt-tech-group\">\n<th colspan=\"2\">Identity and measurement<\/th>\n<\/tr>\n<tr>\n<th>Brand<\/th>\n<td>Eastron<\/td>\n<\/tr>\n<tr>\n<th>Model<\/th>\n<td>SDM230-Modbus (Modbus RTU and pulse output)<\/td>\n<\/tr>\n<tr>\n<th>Device type<\/th>\n<td>Single-phase direct-connected energy meter, DIN rail<\/td>\n<\/tr>\n<tr>\n<th>Wiring system<\/th>\n<td>1 phase, 2 wire (1P2W)<\/td>\n<\/tr>\n<tr>\n<th>Measured quantities<\/th>\n<td>Voltage, current, frequency, power factor, active\/reactive\/apparent power, active and reactive energy, maximum demand<\/td>\n<\/tr>\n<tr>\n<th>Energy direction<\/th>\n<td>Import and export (bidirectional), selectable total<\/td>\n<\/tr>\n<tr>\n<th>Accuracy class<\/th>\n<td>Class 1 \/ class B (IEC 62053-21, EN 50470-1\/-3)<\/td>\n<\/tr>\n<tr>\n<th>MID (2014\/32\/EU)<\/th>\n<td>yes, MID B+D<\/td>\n<\/tr>\n<tr>\n<th>Display<\/th>\n<td>LCD with blue backlight, 16 measured parameters<\/td>\n<\/tr>\n<tr class=\"wt-tech-group\">\n<th colspan=\"2\">Electrical parameters<\/th>\n<\/tr>\n<tr>\n<th>Nominal voltage Un<\/th>\n<td>230 V AC (phase to neutral)<\/td>\n<\/tr>\n<tr>\n<th>Operating voltage range<\/th>\n<td>176\u2013276 V AC (80\u2013120 % of Un)<\/td>\n<\/tr>\n<tr>\n<th>Basic current Ib<\/th>\n<td>10 A<\/td>\n<\/tr>\n<tr>\n<th>Maximum current Imax<\/th>\n<td>100 A, direct connection without CT<\/td>\n<\/tr>\n<tr>\n<th>Current measuring range<\/th>\n<td>from 0.4 % Ib (40 mA) to Imax<\/td>\n<\/tr>\n<tr>\n<th>Short-time overcurrent withstand<\/th>\n<td>30 \u00d7 Imax for 0.01 s<\/td>\n<\/tr>\n<tr>\n<th>Frequency<\/th>\n<td>50 Hz (\u00b110 %)<\/td>\n<\/tr>\n<tr>\n<th>Internal consumption<\/th>\n<td>2 W \/ 10 VA<\/td>\n<\/tr>\n<tr>\n<th>Insulation<\/th>\n<td>4 kV AC for 1 min; 6 kV impulse<\/td>\n<\/tr>\n<tr>\n<th>Overvoltage category<\/th>\n<td>CAT III<\/td>\n<\/tr>\n<tr class=\"wt-tech-group\">\n<th colspan=\"2\">Communication and integration<\/th>\n<\/tr>\n<tr>\n<th>RS485<\/th>\n<td>yes, one port<\/td>\n<\/tr>\n<tr>\n<th>Modbus RTU<\/th>\n<td>yes, slave mode; functions 03\/04\/16 (10h)<\/td>\n<\/tr>\n<tr>\n<th>Baud rate<\/th>\n<td>1200, 2400, 4800, 9600 baud<\/td>\n<\/tr>\n<tr>\n<th>Parity and stop bits<\/th>\n<td>none \/ odd \/ even; 1 or 2 stop bits<\/td>\n<\/tr>\n<tr>\n<th>Modbus address<\/th>\n<td>1\u2013247, broadcast 0<\/td>\n<\/tr>\n<tr>\n<th>Data format<\/th>\n<td>IEEE 754, 32-bit float; measurements in input registers, settings in holding registers<\/td>\n<\/tr>\n<tr>\n<th>Pulse outputs<\/th>\n<td>2 passive outputs; first configurable (0.001 \/ 0.01 \/ 0.1 \/ 1 kWh or kvarh per pulse), second fixed to active energy, 1000 imp\/kWh<\/td>\n<\/tr>\n<tr>\n<th>Pulse width<\/th>\n<td>60 \/ 100 \/ 200 ms<\/td>\n<\/tr>\n<tr>\n<th>Wi-Fi<\/th>\n<td>no<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<th>Bluetooth<\/th>\n<td>no<\/td>\n<\/tr>\n<tr>\n<th>Zigbee<\/th>\n<td>no<\/td>\n<\/tr>\n<tr>\n<th>LoRa<\/th>\n<td>no<\/td>\n<\/tr>\n<tr>\n<th>Ethernet<\/th>\n<td>no<\/td>\n<\/tr>\n<tr>\n<th>Mobile network 4G<\/th>\n<td>no<\/td>\n<\/tr>\n<tr>\n<th>Local API<\/th>\n<td>yes, Modbus RTU over RS485<\/td>\n<\/tr>\n<tr>\n<th>Cloud API<\/th>\n<td>via the system the meter is connected to (inverter and its cloud)<\/td>\n<\/tr>\n<tr>\n<th>App<\/th>\n<td>meter data in the app of the connected inverter; settings on the meter display<\/td>\n<\/tr>\n<tr>\n<th>Modbus TCP<\/th>\n<td>via an RS485 \u2194 Modbus TCP gateway<\/td>\n<\/tr>\n<tr>\n<th>MQTT<\/th>\n<td>via an RS485 \u2194 MQTT converter<\/td>\n<\/tr>\n<tr>\n<th>Home Assistant<\/th>\n<td>yes, Modbus integration via an RS485 converter<\/td>\n<\/tr>\n<tr>\n<th>Modbus RTU master<\/th>\n<td>inverter, RS485\/TCP gateway, PLC<\/td>\n<\/tr>\n<tr class=\"wt-tech-group\">\n<th colspan=\"2\">Compatibility<\/th>\n<\/tr>\n<tr>\n<th>Deye<\/th>\n<td>Deye hybrid inverters with Eastron meter over RS485 (SDM230Modbus V1 in the Eastron solar application table)<\/td>\n<\/tr>\n<tr>\n<th>SolaX<\/th>\n<td>SDM230-Modbus manual published by SolaX for its meter input<\/td>\n<\/tr>\n<tr>\n<th>Other systems<\/th>\n<td>any Modbus RTU master using the Eastron SDM230 register map and further inverter brands<\/td>\n<\/tr>\n<tr class=\"wt-tech-group\">\n<th colspan=\"2\">Construction and environment<\/th>\n<\/tr>\n<tr>\n<th>Dimensions (W \u00d7 H \u00d7 D)<\/th>\n<td>36 \u00d7 99 \u00d7 63 mm (2 modules, DIN 43880)<\/td>\n<\/tr>\n<tr>\n<th>Mounting<\/th>\n<td>35 mm DIN rail<\/td>\n<\/tr>\n<tr>\n<th>Terminals<\/th>\n<td>cage terminals, wire up to 25 mm\u00b2, tightening torque 6 Nm<\/td>\n<\/tr>\n<tr>\n<th>Housing material<\/th>\n<td>self-extinguishing plastic UL 94 V-0<\/td>\n<\/tr>\n<tr>\n<th>Ingress protection<\/th>\n<td>IP51 (indoor)<\/td>\n<\/tr>\n<tr>\n<th>Protection class<\/th>\n<td>II (insulated enclosure)<\/td>\n<\/tr>\n<tr>\n<th>Operating temperature<\/th>\n<td>\u221225 to +55 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th>Storage temperature<\/th>\n<td>\u221240 to +70 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th>Humidity<\/th>\n<td>up to 95 %, non-condensing<\/td>\n<\/tr>\n<tr>\n<th>Altitude<\/th>\n<td>up to 3,000 m<\/td>\n<\/tr>\n<tr>\n<th>Mechanical and EMC environment<\/th>\n<td>M1, E2<\/td>\n<\/tr>\n<tr class=\"wt-tech-group\">\n<th colspan=\"2\">Standards and package<\/th>\n<\/tr>\n<tr>\n<th>Standards<\/th>\n<td>IEC 62053-21, EN 50470-1, EN 50470-3, MID 2014\/32\/EU (B+D)<\/td>\n<\/tr>\n<tr>\n<th>Package contents<\/th>\n<td>Eastron SDM230-Modbus energy meter, 1 pc<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2>Direct measurement of one phase up to 100 A<\/h2>\n<p>The Eastron SDM230-Modbus is designed as a direct-connected meter for 230 V single-phase networks. The current path runs straight through the device up to a maximum current of 100 A; the basic current is 10 A and the measuring range starts at 0.4 % of the basic current, which is 40 mA. No current transformers have to be fitted, so wiring is reduced to the phase in, the phase out and the neutral.<\/p>\n<p>The voltage range of 176\u2013276 V AC corresponds to 80 to 120 % of the nominal 230 V and covers normal fluctuation in the distribution grid. The meter withstands a short overcurrent of 30 times its maximum current for 0.01 s, the insulation holds 4 kV AC for one minute and the impulse withstand is 6 kV. Overvoltage category CAT III makes it suitable for the distribution board at the connection point.<\/p>\n<p>The meter itself consumes 2 W \/ 10 VA and works at 50 Hz with \u00b110 % tolerance. This combination makes it a dependable guardian of energy flow in homes, small businesses and EV charging points.<\/p>\n<h2>MID B+D certification and class 1 accuracy<\/h2>\n<p>The model belongs to the SDM230 series certified under the European MID directive 2014\/32\/EU (modules B+D). Active energy accuracy meets class 1 under IEC 62053-21 and class B under EN 50470-1\/-3, so the meter is suitable wherever officially recognised measurement of supplied and consumed energy is required.<\/p>\n<p>Energy is measured in both import and export directions. The displayed total can be chosen to suit the application: total as import, import plus export, export minus import (net value) or import minus export.<\/p>\n<p>In terms of environment, the meter is classified M1 mechanical and E2 electromagnetic. A self-extinguishing UL 94 V-0 housing and protection class II add safety when mounting in a standard distribution board.<\/p>\n<h2>Measured quantities and display<\/h2>\n<p>The Eastron SDM230-Modbus measures voltage, current, frequency, power factor, active power, reactive power and apparent power. It adds active and reactive energy for import and export, and the maximum demand. Values are shown on an LCD with blue backlight that stays readable in a dark cabinet.<\/p>\n<p>The display offers 16 measured parameters, and you move between them with the buttons. Communication, pulse output and other settings are made directly on the device, so commissioning needs neither a computer nor an app.<\/p>\n<ul>\n<li><strong>Instantaneous values:<\/strong> voltage, current, frequency, power factor, power in W, VAr and VA.<\/li>\n<li><strong>Energy:<\/strong> active and reactive, import, export and total.<\/li>\n<li><strong>Demand:<\/strong> maximum demanded power.<\/li>\n<\/ul>\n<h2>RS485 and Modbus RTU communication<\/h2>\n<p>The meter has one RS485 port with the Modbus RTU protocol in slave mode. Choose the baud rate from 1200, 2400, 4800 and 9600, the parity from none, odd and even, 1 or 2 stop bits, and an address in the range 1\u2013247. Address 0 is used for broadcast, so many devices can share one bus.<\/p>\n<p>Values are transferred as 32-bit floating-point numbers according to IEEE 754. Measurements are read with function 04 from the input registers, for example voltage at address 0x0000, current at 0x0006, active power at 0x000C, apparent power at 0x0012, reactive power at 0x0018, power factor at 0x001E and frequency at 0x0046. Settings are held in holding registers, written with function 16 (10h) and read with function 03. The complete map is in the Eastron SDM230-Modbus Protocol document.<\/p>\n<p>Communication runs exclusively over the wired RS485 line, with no Wi-Fi, Bluetooth, Zigbee, LoRa, Ethernet or cellular module involved. Wired RS485 is robust against interference and suits longer runs inside switchgear.<\/p>\n<h2>Pulse outputs<\/h2>\n<p>Two passive pulse outputs complement the bus. The first output is configurable: it follows total, import or export active or reactive energy, and the constant can be set to 0.001, 0.01, 0.1 or 1 kWh (kvarh) per pulse. The second output is fixed to active energy and provides 1000 impulses per kWh.<\/p>\n<p>Pulse width is selectable at 60, 100 or 200 ms so that counters, PLCs and gateway inputs capture it reliably. Pulse outputs are useful where a separate device evaluates the energy, or as a backup alongside Modbus communication.<\/p>\n<h2>Use with hybrid inverters and in installations<\/h2>\n<p>The Eastron SDM230-Modbus is most often used as a meter at the grid connection point of a photovoltaic system with storage. From its data the inverter knows how much energy the house draws from the grid and how much it feeds back, and uses this to manage battery charging and discharging, zero export and export limiting.<\/p>\n<p>The model appears in the Eastron table &#8220;Models for Solar PV Application&#8221; for Deye inverters as the SDM230Modbus V1 variant. The SDM230-Modbus manual is also published by the inverter maker SolaX for its meter input. The meter is equally suitable for sub-metering EV chargers, heat pumps and other single-phase loads up to 100 A.<\/p>\n<p>In family homes and smaller businesses, the SDM230 therefore delivers accurate data for billing, visualisation and load management.<\/p>\n<h2>DIN rail mounting and environment<\/h2>\n<p>The housing measuring 36 \u00d7 99 \u00d7 63 mm (two modules wide according to DIN 43880) clips onto a 35 mm rail. Cage terminals take wires up to 25 mm\u00b2 cross-section, tightened at 6 Nm. Protection rating IP51 is intended for indoor installation in a distribution board.<\/p>\n<p>The meter operates at temperatures from \u221225 to +55 \u00b0C and can be kept from \u221240 to +70 \u00b0C. Relative humidity up to 95 % without condensation and altitude up to 3000 m cover practically all common European installations. After wiring, set the Modbus address and baud rate to match the inverter or gateway.<\/p>\n<h2>Integration into monitoring and Home Assistant<\/h2>\n<p>Standard Eastron registers are supported by a large number of tools. Through an RS485\/USB or RS485\/TCP converter they can be read in Home Assistant, Node-RED, scripts and industrial control systems, and the values published onwards over MQTT.<\/p>\n<p>Because the interface is local, metering works without any cloud or registration. Data stays in the home network and the response is immediate, which helps with zero-export control and quick reaction to changes in consumption.<\/p>\n<h2>Package contents<\/h2>\n<p>The package contains the Eastron SDM230-Modbus energy meter. Accessories such as RS485 converters and shielded cable are chosen to suit the planned installation.<\/p>\n<h2>Downloads<\/h2>\n<ul>\n<li><a href=\"\/wp-content\/themes\/wodatherm\/assets\/documents\/products\/eastron-sdm230-modbus-en.md\">Product overview Markdown<\/a><\/li>\n<\/ul>\n<section class=\"tomo-ai-search-profile\" data-ai-profile=\"61030\">\n<h2>AI search description<\/h2>\n<p>The Eastron SDM230-Modbus is a single-phase energy meter with direct measurement up to 100 A and MID B+D certification (class 1 \/ B, IEC 62053-21, EN 50470). It is intended for metering at the grid connection point, sub-metering and hybrid photovoltaic systems. It communicates over RS485 using Modbus RTU (1200\u20139600 baud, address 1\u2013247, IEEE 754 float) and has two passive pulse outputs. It measures voltage, current, frequency, power factor, power, and import and export of active and reactive energy. 35 mm DIN rail, 36 \u00d7 99 \u00d7 63 mm, IP51, \u221225 to +55 \u00b0C. Documented with Deye hybrid inverters and SolaX documentation. The backlit LCD shows 16 measured parameters, and the data can be brought into Home Assistant through an RS485 converter or into Modbus TCP through a gateway.<\/p>\n<p>Product page: <a href=\"https:\/\/batterado.com\/en\/product\/eastron-sdm230-modbus\/\">https:\/\/batterado.com\/en\/product\/eastron-sdm230-modbus\/<\/a><\/p>\n<\/section>\n","protected":false},"excerpt":{"rendered":"<p><strong>A single-phase MID B+D certified energy meter that measures directly up to 100 A and passes its data to the inverter over RS485 without current transformers.<\/strong> At the grid connection point, the Eastron SDM230-Modbus records consumption and feed-in precisely in both directions with class 1 accuracy.<\/p>\n<p>The blue-backlit display shows 16 parameters: voltage, current, frequency, power factor, active, reactive and apparent power, active and reactive energy, and maximum demand. Modbus RTU with address 1\u2013247 and 1200\u20139600 baud works with hybrid inverters, RS485\/TCP gateways and control systems, while two passive pulse outputs serve external counters.<\/p>\n<p>The 36 mm wide housing (2 modules) snaps onto a 35 mm DIN rail, the cage terminals take wires up to 25 mm\u00b2, and operation is rated from \u221225 to +55 \u00b0C. The proven Eastron design is a favourite in photovoltaic and battery installations that need accurate, certified and easily connected consumption metering.<\/p>\n","protected":false},"featured_media":61097,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[4044],"product_cat":[4046,3615],"product_tag":[4016,3807,3782],"class_list":["post-61030","product","type-product","status-publish","has-post-thumbnail","product_brand-eastron","product_cat-energy-meters","product_cat-photovoltaic-accessories","product_tag-eastron-sdm-230-modbus","product_tag-rs485","product_tag-deye-inverter-accessory","first","instock","taxable","shipping-taxable","purchasable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product\/61030","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/comments?post=61030"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/media\/61097"}],"wp:attachment":[{"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/media?parent=61030"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product_brand?post=61030"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product_cat?post=61030"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product_tag?post=61030"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}