{"id":60570,"date":"2026-11-21T15:50:19","date_gmt":"2026-11-21T13:50:19","guid":{"rendered":"https:\/\/batterado.com\/product\/victron-lynx-shunt-ve-can-m10\/"},"modified":"2026-11-21T15:50:29","modified_gmt":"2026-11-21T13:50:29","slug":"victron-lynx-shunt-ve-can-m10","status":"publish","type":"product","link":"https:\/\/batterado.com\/en\/product\/victron-lynx-shunt-ve-can-m10\/","title":{"rendered":"Victron Energy Lynx Shunt VE.Can (M10) busbar battery monitor with 1000 A shunt, 12\/24\/48 V, VE.Can and alarm relay"},"content":{"rendered":"<h2>Technical data<\/h2>\n<div class=\"wt-tech-grid\">\n<table>\n<tbody>\n<tr>\n<th>Brand<\/th>\n<td>Victron Energy<\/td>\n<\/tr>\n<tr>\n<th>Model<\/th>\n<td>Lynx Shunt VE.Can (M10)<\/td>\n<\/tr>\n<tr>\n<th>Part number<\/th>\n<td>LYN040102110<\/td>\n<\/tr>\n<tr>\n<th>Device type<\/th>\n<td>Busbar with shunt and battery monitor<\/td>\n<\/tr>\n<tr>\n<th>Battery voltage<\/th>\n<td>12, 24 and 48 V<\/td>\n<\/tr>\n<tr>\n<th>Supply voltage range<\/th>\n<td>9 to 70 Vdc<\/td>\n<\/tr>\n<tr>\n<th>Continuous current<\/th>\n<td>1000 A<\/td>\n<\/tr>\n<tr>\n<th>Reverse polarity protection<\/th>\n<td>no<\/td>\n<\/tr>\n<tr>\n<th>Own consumption<\/th>\n<td>60 mA at 12 V, 33 mA at 24 V, 20 mA at 48 V<\/td>\n<\/tr>\n<tr>\n<th>Battery capacity range<\/th>\n<td>1 to 32500 Ah (up to version 4.19 max. 9999 Ah), default 200 Ah<\/td>\n<\/tr>\n<tr>\n<th>Peukert exponent<\/th>\n<td>1.00 to 1.50, default 1.25<\/td>\n<\/tr>\n<tr>\n<th>Tail current<\/th>\n<td>default 4 % (0.5 to 10 %)<\/td>\n<\/tr>\n<tr>\n<th>Monitor settings<\/th>\n<td>capacity, charged voltage, tail current, Peukert exponent, SoC synchronisation<\/td>\n<\/tr>\n<tr>\n<th>Positive busbar<\/th>\n<td>with room for a main fuse (CNN, ANL; Mega on M6 bolts)<\/td>\n<\/tr>\n<tr>\n<th>Negative busbar<\/th>\n<td>with shunt and battery monitor<\/td>\n<\/tr>\n<tr>\n<th>Suggested main fuse<\/th>\n<td>325 A \/ 80 V CNN (Victron CIP140325000), otherwise 35 to 800 A depending on the system<\/td>\n<\/tr>\n<tr>\n<th>Busbar connections between modules<\/th>\n<td>M10<\/td>\n<\/tr>\n<tr>\n<th>Fuse connections<\/th>\n<td>M8 (a busbar piece instead of a fuse is supplied)<\/td>\n<\/tr>\n<tr>\n<th>VE.Can port<\/th>\n<td>2x RJ45, 250 kbit\/s; 2 terminators supplied<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<th>RJ10 port<\/th>\n<td>power for a Lynx Distributor (no fuse communication)<\/td>\n<\/tr>\n<tr>\n<th>Temperature sensor input<\/th>\n<td>screw terminal, sensor ASS000001000 supplied<\/td>\n<\/tr>\n<tr>\n<th>Alarm relay<\/th>\n<td>potential-free contact, 3 A \/ 30 Vdc \/ 250 Vac, screw terminal<\/td>\n<\/tr>\n<tr>\n<th>Alarm relay triggers<\/th>\n<td>SoC, battery voltage, battery temperature, blown fuse (set in the GX device)<\/td>\n<\/tr>\n<tr>\n<th>VE.Can protocol<\/th>\n<td>VE.Can, profile VE.Can &#038; Lynx Ion BMS (250 kbit\/s)<\/td>\n<\/tr>\n<tr>\n<th>NMEA 2000 protocol<\/th>\n<td>PGN 126996, 127506, 127508, 127501<\/td>\n<\/tr>\n<tr>\n<th>Data in GX device and on VRM<\/th>\n<td>voltage, current, power, SoC, consumed Ah, time to go, relay state, alarm, temperature, firmware, history<\/td>\n<\/tr>\n<tr>\n<th>Compatibility<\/th>\n<td>GX devices (profile VE.Can &#038; Lynx Ion BMS, BMS-Can port cannot be used), VE.Can, VRM, Lynx modules<\/td>\n<\/tr>\n<tr>\n<th>LED indication<\/th>\n<td>green OK, red blown main fuse, orange active alarm<\/td>\n<\/tr>\n<tr>\n<th>Busbar material<\/th>\n<td>tin-plated copper 8 x 30 mm<\/td>\n<\/tr>\n<tr>\n<th>Housing material<\/th>\n<td>ABS plastic<\/td>\n<\/tr>\n<tr>\n<th>Dimensions (h x w x d)<\/th>\n<td>190 x 180 x 80 mm<\/td>\n<\/tr>\n<tr>\n<th>Weight<\/th>\n<td>1.4 kg<\/td>\n<\/tr>\n<tr>\n<th>Protection class<\/th>\n<td>IP22<\/td>\n<\/tr>\n<tr>\n<th>Operating temperature<\/th>\n<td>-40 to +60 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th>Storage temperature<\/th>\n<td>-40 to +60 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th>Humidity<\/th>\n<td>max. 95 % non-condensing<\/td>\n<\/tr>\n<tr>\n<th>Tightening torques<\/th>\n<td>M10: 33 Nm (17 Nm before serial no. HQ2340), M8: 14 Nm<\/td>\n<\/tr>\n<tr>\n<th>Package contents<\/th>\n<td>Lynx Shunt VE.Can (M10), 2 VE.Can RJ45 terminators, temperature sensor with ferrules and terminal block, busbar piece instead of a fuse, quick-guide sticker, label folder<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2>What the Lynx Shunt VE.Can does<\/h2>\n<p>The Lynx Shunt VE.Can (M10) is a 1000 A busbar that combines a solid battery connection and a battery monitor in one housing. The positive busbar has room for a main fuse; the negative busbar contains the shunt and the measuring electronics. The unit measures battery voltage and current and calculates power, state of charge (SoC), consumed Ah and time to go from them.<\/p>\n<p>The shunt is intended for 12, 24 and 48 V batteries with a supply of 9 to 70 Vdc. Its own consumption is 60 mA at 12 V, 33 mA at 24 V and 20 mA at 48 V. The unit has no reverse polarity protection, so polarity must be checked carefully when wiring.<\/p>\n<p>In the Lynx system the Shunt VE.Can serves batteries of brands other than Victron Lithium Smart and NG; the Lynx Smart BMS is intended for those. The measurements are provided to GX devices over VE.Can.<\/p>\n<h2>The Lynx system: joining modules<\/h2>\n<p>The Shunt is part of the Lynx busbar system. The Lynx system comprises the modules Lynx Power In, Class-T Power In, Lynx Distributor, Lynx Shunt VE.Can and Lynx Smart BMS. The modules are bolted directly to each other with M10 busbars, with no cables between them; an M10 module cannot be joined directly to an M8 module. The stickers allow installation in any orientation.<\/p>\n<p>The arrangement is as follows: batteries connect to one side of the Shunt (on the left) and loads and chargers to the other (right). The rated current of all modules is 1000 A. The box includes a busbar piece in place of a fuse for when you do not use a main fuse; fuse connections have an M8 thread.<\/p>\n<p>The Shunt is joined to a Lynx Distributor with an RJ10 cable which only powers the Distributor. Fuse communication between a Distributor and the Shunt VE.Can is not possible; it works only with the Smart BMS. If you want an overview of the state of the fused branches in VRM, a system with a Smart BMS is required.<\/p>\n<h2>Main fuse and wiring<\/h2>\n<p>The positive busbar allows a CNN or ANL main fuse to be fitted; a Mega fuse can be fixed on M6 bolts. An example is a 325 A \/ 80 V CNN fuse (Victron CIP140325000); in general the fuse may be 35 to 800 A depending on the system.<\/p>\n<p>The M10 nuts are tightened to 33 Nm (17 Nm for products before serial number HQ2340), M8 connections to 14 Nm. The unit is mounted in a dry indoor space (IP22).<\/p>\n<p>The temperature sensor (ASS000001000) from the box connects to a screw terminal and measures battery temperature. The sensor comes with ferrules and a terminal block; the temperature can be used for alarms and for display on the GX device and VRM.<\/p>\n<h2>VE.Can and connecting to a GX device<\/h2>\n<p>The Shunt communicates over VE.Can through two RJ45 connectors; terminators must be fitted at the ends of the bus, and two are in the box. In the GX device (for example a Cerbo GX) the profile VE.Can &#038; Lynx Ion BMS at 250 kbit\/s must be used for the VE.Can port. The BMS-Can port cannot be used for the Shunt.<\/p>\n<p>Over VE.Can the GX device and the VRM portal receive voltage, current, power, SoC, consumed Ah, time to go, relay state, alarm, temperature, firmware version and history. The Shunt also transmits NMEA 2000 data (PGN 126996, 127506, 127508 and 127501), so it can be connected to a marine network as well.<\/p>\n<h2>Battery monitor settings<\/h2>\n<p>The monitor is set up according to the battery. Capacity can be entered from 1 to 32500 Ah (default 200 Ah; in firmware versions up to 4.19 at most 9999 Ah). Further settings are the charged voltage, the tail current (default 4 %, range 0.5 to 10 %) and the Peukert exponent in the range 1.00 to 1.50 (default 1.25). SoC synchronisation matters, as it returns the SoC to 100 % after a full charge.<\/p>\n<p>Settings are made in VictronConnect or from the GX device. Correct battery parameters decide the accuracy of the SoC.<\/p>\n<h2>Alarm relay and LED<\/h2>\n<p>The unit has a potential-free alarm relay (3 A, 30 Vdc or 250 Vac) on a screw terminal. The relay is programmed from the GX device and can react to state of charge, battery voltage, battery temperature or a blown fuse. It suits starting a generator, signalling or disconnecting a load through an external component.<\/p>\n<p>The status LED is green in normal operation, red with a blown main fuse and orange with an active alarm; further states are distinguished by blinking. Once connected, the data also appears in VictronConnect and on VRM, where you can view the history.<\/p>\n<h2>What to combine the Shunt with<\/h2>\n<p>The Lynx Shunt VE.Can is the choice for batteries without a communicating Victron BMS: the monitor reliably tracks the state of charge of any 12, 24 or 48 V battery. For Victron Lithium Smart and NG batteries the Lynx system provides the Lynx Smart BMS, which in addition protects the battery and communicates with the Distributor.<\/p>\n<p>Further Lynx modules are bolted to the Shunt with M10: Lynx Power In for the battery feed, Class-T Power In for protection with a Class-T fuse and the Lynx Distributor for four fused branches. The Distributor receives only power over RJ10 here. A GX device, for example the Cerbo GX, is the control unit of the whole system; it shows the data locally and sends it to VRM.<\/p>\n<p>The sum of the fuse ratings in the system must not exceed the rated current of the weakest module. All Lynx modules are rated 1000 A.<\/p>\n<h2>Operation and monitoring<\/h2>\n<p>Once connected to the GX device the Shunt appears in the device list as a battery monitor. You see the data there immediately and, once connected to the internet, also on the VRM portal including history. The alarm relay and temperature sensor let you react to low state of charge, voltage, temperature or a blown main fuse.<\/p>\n<p>The basic values (capacity, charged voltage, tail current, Peukert exponent) are entered once at commissioning. The unit has no reverse polarity protection, so check the polarity when wiring. Installation and wiring should be carried out by a qualified electrician.<\/p>\n<section class=\"tomo-ai-search-profile\">\n<h2>AI search description<\/h2>\n<p>The Victron Lynx Shunt VE.Can (M10), part number LYN040102110, is a 1000 A busbar with shunt and battery monitor for 12, 24 and 48 V batteries (supply 9 to 70 Vdc). It has room for a main fuse, a VE.Can interface (RJ45, 250 kbit\/s, NMEA 2000), RJ10 to power a Lynx Distributor, a temperature sensor input and a 3 A potential-free alarm relay. Battery capacity 1 to 32500 Ah. Data goes to a GX device and VRM. ABS housing, 190 x 180 x 80 mm, 1.4 kg, IP22. Part of the Lynx system for batteries of other brands.<\/p>\n<p>Product page: <a href=\"https:\/\/batterado.com\/product\/victron-lynx-shunt-ve-can-m10\/\">https:\/\/batterado.com\/product\/victron-lynx-shunt-ve-can-m10\/<\/a><\/p>\n<\/section>\n","protected":false},"excerpt":{"rendered":"<p><strong>The Victron Lynx Shunt VE.Can (M10) combines a battery monitor with a solid 1000 A busbar and sends state of charge, voltage, current and power to a GX device over VE.Can.<\/strong><\/p>\n<ul>\n<li>Positive busbar with room for a main fuse, negative busbar with the shunt and battery monitor.<\/li>\n<li>For 12, 24 and 48 V batteries, supply 9 to 70 Vdc, 1000 A continuous.<\/li>\n<li>VE.Can (RJ45) interface for GX devices, VRM and NMEA 2000; powers a Lynx Distributor over RJ10.<\/li>\n<li>Potential-free programmable alarm contact and a temperature sensor input (sensor included).<\/li>\n<li>Status LED and battery capacity 1 to 32500 Ah.<\/li>\n<\/ul>\n<p>Tin-plated copper, ABS housing, dimensions 190 x 180 x 80 mm, weight 1.4 kg, IP22.<\/p>\n","protected":false},"featured_media":60571,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[3882],"product_cat":[2889,2753],"product_tag":[3901,3898,3874],"class_list":["post-60570","product","type-product","status-publish","has-post-thumbnail","product_brand-victron-energy","product_cat-battery-accessories","product_cat-bateriova-uloziste","product_tag-lyn040102110","product_tag-lynx","product_tag-prislusenstvi-baterie","first","instock","taxable","shipping-taxable","purchasable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product\/60570","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/comments?post=60570"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/media\/60571"}],"wp:attachment":[{"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/media?parent=60570"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product_brand?post=60570"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product_cat?post=60570"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product_tag?post=60570"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}