{"id":60544,"date":"2026-11-21T15:49:34","date_gmt":"2026-11-21T13:49:34","guid":{"rendered":"https:\/\/batterado.com\/product\/victron-energy-meter-em540\/"},"modified":"2026-11-21T15:49:35","modified_gmt":"2026-11-21T13:49:35","slug":"victron-energy-meter-em540","status":"publish","type":"product","link":"https:\/\/batterado.com\/en\/product\/victron-energy-meter-em540\/","title":{"rendered":"Victron Energy Energy Meter EM540 three-phase energy meter for GX devices, direct measurement up to 65 A per phase, RS485"},"content":{"rendered":"<h2>Technical data<\/h2>\n<div class=\"wt-tech-grid\">\n<table>\n<tbody>\n<tr>\n<th>Brand<\/th>\n<td>Victron Energy<\/td>\n<\/tr>\n<tr>\n<th>Model<\/th>\n<td>Energy Meter EM540<\/td>\n<\/tr>\n<tr>\n<th>Part number<\/th>\n<td>REL200100100<\/td>\n<\/tr>\n<tr>\n<th>Corresponds to Carlo Gavazzi type<\/th>\n<td>EM540DINAV23XS1X<\/td>\n<\/tr>\n<tr>\n<th>Device type<\/th>\n<td>Three-phase energy meter<\/td>\n<\/tr>\n<tr>\n<th>Phases<\/th>\n<td>3<\/td>\n<\/tr>\n<tr>\n<th>Measurement type<\/th>\n<td>direct (Direct\/Shunt)<\/td>\n<\/tr>\n<tr>\n<th>Max. current rating<\/th>\n<td>65 A per phase<\/td>\n<\/tr>\n<tr>\n<th>Current transformers<\/th>\n<td>not used<\/td>\n<\/tr>\n<tr>\n<th>Display<\/th>\n<td>LCD<\/td>\n<\/tr>\n<tr>\n<th>Refresh rate<\/th>\n<td>100 ms<\/td>\n<\/tr>\n<tr>\n<th>Power factor reporting<\/th>\n<td>yes<\/td>\n<\/tr>\n<tr>\n<th>Energy registration<\/th>\n<td>vector<\/td>\n<\/tr>\n<tr>\n<th>Communication<\/th>\n<td>RS485<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<th>Connection to GX device (wired)<\/th>\n<td>RS485 to USB interface, cable 1.8 m or 5 m<\/td>\n<\/tr>\n<tr>\n<th>Connection to GX device (wireless)<\/th>\n<td>Zigbee to USB and Zigbee to RS485 converters<\/td>\n<\/tr>\n<tr>\n<th>RS485 to USB cable extension<\/th>\n<td>up to 100 m<\/td>\n<\/tr>\n<tr>\n<th>RS485 terminals<\/th>\n<td>8 (Data+), 9 (Data-), 10 (GND)<\/td>\n<\/tr>\n<tr>\n<th>Phase and neutral terminals<\/th>\n<td>1, 2, 3 (L1, L2, L3), N; terminals 4, 5, 6 for grid phasing<\/td>\n<\/tr>\n<tr>\n<th>Protocol<\/th>\n<td>Modbus (address set on the meter)<\/td>\n<\/tr>\n<tr>\n<th>Modbus addresses usable in the system<\/th>\n<td>1 (default) and 2<\/td>\n<\/tr>\n<tr>\n<th>Roles in the GX device<\/th>\n<td>grid meter, PV inverter, AC genset, AC meter for a load<\/td>\n<\/tr>\n<tr>\n<th>Single-phase use<\/th>\n<td>yes, grid on terminal L1; the second phase can measure a PV inverter<\/td>\n<\/tr>\n<tr>\n<th>Fuse in the voltage circuit<\/th>\n<td>315 mA, if required by local law<\/td>\n<\/tr>\n<tr>\n<th>Compatibility<\/th>\n<td>GX devices (e.g. Cerbo GX), VRM portal<\/td>\n<\/tr>\n<tr>\n<th>Minimum Venus OS version for new Zigbee converters<\/th>\n<td>v2.54<\/td>\n<\/tr>\n<tr>\n<th>Multiple meters<\/th>\n<td>up to two on one bus (addresses 1 and 2)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2>What the EM540 is for<\/h2>\n<p>The Victron EM540 is a standard device for measuring the power and energy of a three-phase application. Its data is displayed on a GX device and on the VRM portal. The meter is three-phase, measures directly up to 65 A per phase and has an LCD, so the values can also be read on site.<\/p>\n<p>The main advantage is that no current transformers are needed: the phase conductors are routed directly through the meter. Wiring is therefore simpler and faster than with meters that use transformers. The meter is designed as a supplement to Victron inverter\/chargers: it provides information about what happens in the distribution board, i.e. grid import, grid export, PV production or the consumption of individual circuits.<\/p>\n<p>The EM540 corresponds to the Carlo Gavazzi EM540DINAV23XS1X. The refresh rate of the measured values is 100 ms and the meter also reports power factor, which is useful for fast control of power flow in the system.<\/p>\n<h2>Four roles in the GX device<\/h2>\n<p>You set the role of the meter in the GX device (for example the Cerbo GX) under Settings, Energy meters. The choice of role also affects how the system is wired and how the data is displayed. The EM540 can be configured as:<\/p>\n<ul>\n<li><strong>grid meter<\/strong> and control input for an ESS system,<\/li>\n<li><strong>meter of a PV inverter output<\/strong> (AC),<\/li>\n<li><strong>meter of an AC genset<\/strong>,<\/li>\n<li><strong>AC meter<\/strong> for a dedicated load circuit.<\/li>\n<\/ul>\n<p>After connection and power-up the meter appears in the GX device list. There you set the role and the phase type (single phase, multi phase). The detailed overview shows consumption and generation in all phases, the role can later be changed in the Setup menu, and the meter can be given a custom name.<\/p>\n<p>With GX firmware version 2.80 and later the meter can also be used to measure arbitrary AC loads or circuits. It does not replace a Victron inverter\/charger, however: attempting to substitute the missing data connectivity of other brands&#8217; inverters with an energy meter will not work as expected.<\/p>\n<h2>AC wiring<\/h2>\n<p>The role configuration is set in the GX device and the wiring is chosen accordingly. The following applies:<\/p>\n<ul>\n<li><strong>Three-phase grid meter or PV inverter meter:<\/strong> phases and neutral are connected to terminals N, 1, 2 and 3 (L1, L2, L3). When measuring a three-phase PV inverter, terminals 1, 2 and 3 face the inverter.<\/li>\n<li><strong>Single-phase inverter in a three-phase system:<\/strong> all three phases are connected to the grid phasing terminals (4, 5 and 6) and the L1 conductor of the inverter to the chosen phase (terminal 1, 2 or 3).<\/li>\n<li><strong>Single-phase system:<\/strong> the grid is connected to L1 (terminal 1) of the meter.<\/li>\n<li><strong>Single-phase, dual function:<\/strong> if you want to use the three-phase meter in a single-phase installation to measure the grid on one input and the PV inverter output on another, the meter uses L1 for the grid and L2 for the inverter.<\/li>\n<\/ul>\n<p>The manufacturer&#8217;s diagrams mark a fuse in the voltage circuit of the meter; a 315 mA fuse should be used if required by local law. Installation and wiring belong to a qualified electrician.<\/p>\n<h2>Connecting to the GX device<\/h2>\n<p><strong>By cable (RS485):<\/strong> the EM540 connects to the GX device via the RS485 to USB interface with a 1.8 m or 5 m cable. The meter is plug and play: its RS485 settings are already configured for connection to a GX device. The data wires go to terminals 8 (Data+, orange), 9 (Data-, yellow) and 10 (GND, black). The red, green and brown wires of the cable are not used and must be cut off or bent back and insulated.<\/p>\n<p>The cable between the GX device and the meter can be extended up to 100 m, but the Data+ and Data- wires must form a twisted pair. For reliable operation Victron recommends shielded cable with twisted pairs, routed away from DC and AC power cables, with all wires properly terminated. 120 \u03a9 terminators are not required for short distances with the original Victron cable.<\/p>\n<p><strong>Wirelessly (Zigbee):<\/strong> the meter can also be connected via a Zigbee to USB converter (at the GX device) and a Zigbee to RS485 converter (at the meter). The new Zigbee converters require Venus OS v2.54 or later. Victron does not recommend multiple Zigbee pairs; connecting a meter via Ethernet is the more reliable option.<\/p>\n<h2>Several meters in one system<\/h2>\n<p>Several energy meters can be combined in one system in three ways: each meter wired to its own RS485 to USB interface plugged into a separate USB socket of the GX device; two meters on one RS485 to USB interface (the modbus address of the additional meter must be changed so that each is unique); or wirelessly, where the additional meter is connected to another Zigbee to RS485 converter and no second Zigbee to USB converter is required. In that case too, the modbus address of one meter must be changed.<\/p>\n<p>Only one additional meter can be added: the system works only with addresses 1 (default) and 2. You change the address on the EM540 itself with the small button next to the display: in the Setting, System, RS485 and Address menus set address 2 and leave the menu via End and back.<\/p>\n<p>In a single-phase installation the unused second phase can be used to measure the power of a PV inverter, so a second meter may not be needed.<\/p>\n<h2>EM540 or ET340<\/h2>\n<p>Both three-phase versions measure directly up to 65 A per phase; they differ in how energy is totalled. In the ET340, imported and exported energy is counted at each individual phase and the total is the sum of those values. In the EM540, imported and exported energy is counted as a total power, with net differential readings from each phase cancelling each other out. In Austria and Germany, for example, it is common to be billed only for the total in a three-phase system, so the EM540 matches the billing more accurately.<\/p>\n<p>If you export from one phase and import on another after the energy meter but before the billing meter, you are not charged for it, and the meter should therefore not count it as an import and an export. This is also how Victron&#8217;s phase compensation works, using the difference in generation and load between phases in an ESS system.<\/p>\n<p>Another difference: the EM540 has an LCD, whereas the ET340 only has an LED that blinks during communication. The modbus address can also be changed on the EM540, so two meters can be combined on one bus; Victron does not support this with the ET meters. The EM540 supports vector registration only.<\/p>\n<h2>Limits of the EM540<\/h2>\n<p>The EM540 is intended for direct measurement up to 65 A per phase. For currents above 65 A per phase there are solutions with current transformers (for example the VM-3P75CT or VM-3P5A), for single-phase measurement above 100 A also transformers, and for split-phase above 65 A a three-phase solution with transformers. Single-phase measurement up to 100 A is covered by the ET1XX \/ EM1XX types.<\/p>\n<p>For a single-phase utility connection that also requires measuring a PV inverter, the ET340 is the suitable choice. Meters of other brands cannot be used in the system, which also applies to the Fronius SmartGrid meter.<\/p>\n<p>Most PV inverters support direct readout by the Victron system, so an additional energy meter is not always required. The EM540 supplements a Victron inverter\/charger and each meter provides only a specific piece of additional information.<\/p>\n<h2>Operation and monitoring<\/h2>\n<p>The meter data is displayed on the GX device (for example a Cerbo GX with a GX Touch display) and, once connected to the internet, on the VRM portal, where it can be monitored remotely. The detailed overview on the GX device shows consumption and generation in all phases, the Device menu holds the data used for communication, and a custom name can be given to the meter.<\/p>\n<p>As a grid meter the EM540 serves as the control input of an ESS system. The meter can also be used to determine the consumption of buildings, heat pumps, air conditioning or production facilities before sizing the inverter, PV and batteries: it is possible to start with just a GX device and an energy meter and evaluate the collected data later.<\/p>\n<p>Settings are made on the GX device and on the display of the meter.<\/p>\n<section class=\"tomo-ai-search-profile\">\n<h2>AI search description<\/h2>\n<p>The Victron Energy Meter EM540 (part number REL200100100, corresponds to the Carlo Gavazzi EM540DINAV23XS1X) is a three-phase energy meter with direct measurement up to 65 A per phase and an LCD display. It communicates over RS485 and connects to a GX device (for example the Cerbo GX) via the RS485 to USB interface or wirelessly via Zigbee converters. In the GX device it works as a grid meter for ESS, a PV inverter meter, an AC genset meter or an AC load meter. The refresh rate is 100 ms, it reports power factor and uses vector energy registration. The data is available on the VRM portal.<\/p>\n<p>Product page: <a href=\"https:\/\/batterado.com\/product\/victron-energy-meter-em540\/\">https:\/\/batterado.com\/product\/victron-energy-meter-em540\/<\/a><\/p>\n<\/section>\n","protected":false},"excerpt":{"rendered":"<p><strong>The Victron Energy Meter EM540 measures the power and energy of a three-phase application directly, without current transformers, up to 65 A per phase, and sends the data to a GX device and the VRM portal.<\/strong><\/p>\n<ul>\n<li>Three-phase meter with direct measurement up to 65 A per phase and an LCD display.<\/li>\n<li>Four roles in the GX device: grid meter as control input for an ESS system, PV inverter output measurement, AC genset measurement, or measurement of a dedicated AC load circuit.<\/li>\n<li>RS485 communication; connection to the GX device by cable via the RS485 to USB interface (1.8 m or 5 m) or wirelessly via Zigbee converters.<\/li>\n<li>Refresh rate of the measured values 100 ms, power factor reporting, vector energy registration.<\/li>\n<li>Part number REL200100100, Carlo Gavazzi EM540DINAV23XS1X.<\/li>\n<\/ul>\n<p>The EM540 is used in systems with a GX device, for example the Cerbo GX. The RS485 to USB interface is a separate accessory, planned separately.<\/p>\n","protected":false},"featured_media":60545,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[3882],"product_cat":[3615,3403],"product_tag":[3849,3894,3850],"class_list":["post-60544","product","type-product","status-publish","has-post-thumbnail","product_brand-victron-energy","product_cat-photovoltaic-accessories","product_cat-solar-panel-kits","product_tag-elektromer","product_tag-rel200100100","product_tag-smart-meter","first","instock","taxable","shipping-taxable","purchasable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product\/60544","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/comments?post=60544"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/media\/60545"}],"wp:attachment":[{"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/media?parent=60544"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product_brand?post=60544"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product_cat?post=60544"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product_tag?post=60544"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}