{"id":60401,"date":"2026-11-20T11:50:47","date_gmt":"2026-11-20T09:50:47","guid":{"rendered":"https:\/\/batterado.com\/product\/felicity-ivgm20klp3g1\/"},"modified":"2026-11-21T15:46:55","modified_gmt":"2026-11-21T13:46:55","slug":"felicity-ivgm20klp3g1","status":"publish","type":"product","link":"https:\/\/batterado.com\/en\/product\/felicity-ivgm20klp3g1\/","title":{"rendered":"Felicity Solar IVGM20KLP3G1 Three-Phase Hybrid Inverter 20 kW, 48 V Battery (40\u201360 V), 350 A Charge Current"},"content":{"rendered":"<h2>Technical data<\/h2>\n<div class=\"wt-tech-grid\">\n<table>\n<tbody>\n<tr>\n<th>Brand<\/th>\n<td>Felicity Solar<\/td>\n<\/tr>\n<tr>\n<th>Model<\/th>\n<td>IVGM20KLP3G1<\/td>\n<\/tr>\n<tr>\n<th>Type<\/th>\n<td>Hybrid inverter, three-phase<\/td>\n<\/tr>\n<tr>\n<th>Series<\/th>\n<td>IVGM10\u201320KLP3G1<\/td>\n<\/tr>\n<tr>\n<th>Battery voltage class<\/th>\n<td>Low-voltage (LV), 40\u201360 V<\/td>\n<\/tr>\n<tr>\n<th>Rated AC power<\/th>\n<td>20 kW<\/td>\n<\/tr>\n<tr>\n<th>Max. apparent AC power<\/th>\n<td>22 kVA<\/td>\n<\/tr>\n<tr>\n<th>Peak AC power (off-grid)<\/th>\n<td>40 kW (2\u00d7 rated), 10 s<\/td>\n<\/tr>\n<tr>\n<th>PV: max. power<\/th>\n<td>32 kW<\/td>\n<\/tr>\n<tr>\n<th>PV: max. voltage<\/th>\n<td>800 V<\/td>\n<\/tr>\n<tr>\n<th>PV: start-up voltage<\/th>\n<td>160 V<\/td>\n<\/tr>\n<tr>\n<th>PV: MPPT range<\/th>\n<td>160\u2013650 V<\/td>\n<\/tr>\n<tr>\n<th>PV: nominal voltage<\/th>\n<td>550 V<\/td>\n<\/tr>\n<tr>\n<th>PV: voltage range at full load<\/th>\n<td>550\u2013800 V<\/td>\n<\/tr>\n<tr>\n<th>PV: max. operating input current<\/th>\n<td>36 A + 36 A<\/td>\n<\/tr>\n<tr>\n<th>PV: max. short-circuit current<\/th>\n<td>54 A + 54 A<\/td>\n<\/tr>\n<tr>\n<th>PV: number of MPP trackers \/ strings<\/th>\n<td>2 \/ 2+2<\/td>\n<\/tr>\n<tr>\n<th>Battery: type<\/th>\n<td>Li-Ion \/ lead-acid<\/td>\n<\/tr>\n<tr>\n<th>Battery: voltage range<\/th>\n<td>40\u201360 V<\/td>\n<\/tr>\n<tr>\n<th>Battery: max. charge and discharge current<\/th>\n<td>350 A<\/td>\n<\/tr>\n<tr>\n<th>AC: nominal voltage<\/th>\n<td>220\/380, 230\/400 V (\u221220 % to +15 %)<\/td>\n<\/tr>\n<tr>\n<th>AC: configuration<\/th>\n<td>3L+N+PE<\/td>\n<\/tr>\n<tr>\n<th>AC: nominal frequency<\/th>\n<td>50\/60 Hz (45\u201355 Hz \/ 55\u201365 Hz)<\/td>\n<\/tr>\n<tr>\n<th>AC: rated output current<\/th>\n<td>28.9 A<\/td>\n<\/tr>\n<tr>\n<th>AC: max. output current<\/th>\n<td>31.9 A<\/td>\n<\/tr>\n<tr>\n<th>AC: max. passthrough current (grid to load)<\/th>\n<td>70 A<\/td>\n<\/tr>\n<tr>\n<th>AC: max. output overcurrent protection<\/th>\n<td>92 A<\/td>\n<\/tr>\n<tr>\n<th>AC: THDI<\/th>\n<td>< 3 % (at rated power)<\/td>\n<\/tr>\n<tr>\n<th>AC: displacement power factor<\/th>\n<td>0.8 (leading) to 0.8 (lagging)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<th>Operating modes<\/th>\n<td>On-grid, Off-grid, UPS, Time of Use, Selling First, Zero Export To Load, Zero Export To CT<\/td>\n<\/tr>\n<tr>\n<th>Protections<\/th>\n<td>DC polarity, overcurrent, AC overvoltage and short circuit, thermal protection, DC insulation, DC component, ground current, AFCI, grid and island monitoring, ground fault detection, DC switch, overvoltage load disconnect, RCD<\/td>\n<\/tr>\n<tr>\n<th>Surge protection<\/th>\n<td>TYPE II (DC), TYPE II (AC)<\/td>\n<\/tr>\n<tr>\n<th>AC overvoltage category<\/th>\n<td>III<\/td>\n<\/tr>\n<tr>\n<th>Ports and terminals<\/th>\n<td>BATTERY+ \/ BATTERY\u2212, COM1\u2013COM4, Wi-Fi, GRID, GEN, LOAD, PV1, PV2, PV switch, ON\/OFF button, grounding point<\/td>\n<\/tr>\n<tr>\n<th>Monitoring module<\/th>\n<td>Wi-Fi \/ 4G, FSolar app (Wi-Fi and Bluetooth)<\/td>\n<\/tr>\n<tr>\n<th>Display<\/th>\n<td>colour display<\/td>\n<\/tr>\n<tr>\n<th>Battery (BMS) communication \/ RS485<\/th>\n<td>inverter BMS interface, per the manufacturer datasheet<\/td>\n<\/tr>\n<tr>\n<th>Battery (BMS) communication \/ CAN<\/th>\n<td>inverter BMS interface, per the manufacturer datasheet<\/td>\n<\/tr>\n<tr>\n<th>Felicity LV battery \/ RS485<\/th>\n<td>per the manufacturer list<\/td>\n<\/tr>\n<tr>\n<th>Compatible batteries<\/th>\n<td>FelicityESS low-voltage batteries (manufacturer inverter-brand list, RS485 protocol)<\/td>\n<\/tr>\n<tr>\n<th>Parallel operation<\/th>\n<td>up to 10 units<\/td>\n<\/tr>\n<tr>\n<th>Smart load, generator, micro-inverter<\/th>\n<td>supported (programmable generator port)<\/td>\n<\/tr>\n<tr>\n<th>Protection rating<\/th>\n<td>IP65<\/td>\n<\/tr>\n<tr>\n<th>Operating temperature<\/th>\n<td>\u221240 to +60 \u00b0C (derating above 45 \u00b0C)<\/td>\n<\/tr>\n<tr>\n<th>Humidity and altitude<\/th>\n<td>0\u201395 % non-condensing, up to 2000 m a.s.l.<\/td>\n<\/tr>\n<tr>\n<th>Installation<\/th>\n<td>wall-mounted (wall bracket included)<\/td>\n<\/tr>\n<tr>\n<th>Dimensions (W \u00d7 H \u00d7 D)<\/th>\n<td>750 \u00d7 450 \u00d7 268 mm<\/td>\n<\/tr>\n<tr>\n<th>Net weight<\/th>\n<td>48.7 kg<\/td>\n<\/tr>\n<tr>\n<th>Gross weight<\/th>\n<td>60.2 kg<\/td>\n<\/tr>\n<tr>\n<th>Package dimensions<\/th>\n<td>889 \u00d7 566 \u00d7 397 mm<\/td>\n<\/tr>\n<tr>\n<th>Package contents<\/th>\n<td>inverter, user manual, warranty card, quick installation guide, Wi-Fi module, wall bracket, parallel cable, PV connectors, tool for PV connectors, OT and M10 terminals, magnetic rings, temperature sensor, screws; CT or meter optional<\/td>\n<\/tr>\n<tr>\n<th>Grid connection certification (Czech Republic)<\/th>\n<td>PPDS (DEKRA, no. 4964551.01COC, PPDS Annex 4:2022, type 1a, valid until 26 October 2031)<\/td>\n<\/tr>\n<tr>\n<th>EN 50549-1 certification<\/th>\n<td>yes (certificate GRID-EN50549)<\/td>\n<\/tr>\n<tr>\n<th>VDE-AR-N 4105 certification<\/th>\n<td>yes (certificate GRID-VDE4105)<\/td>\n<\/tr>\n<tr>\n<th>IEC 61727 and Austria (AT) certification<\/th>\n<td>yes (GRID-CONNECTION certificates)<\/td>\n<\/tr>\n<tr>\n<th>CE-EMC certification<\/th>\n<td>EN 62920<\/td>\n<\/tr>\n<tr>\n<th>Manufacturer warranty<\/th>\n<td>10 years<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2>A 20 kW three-phase hybrid inverter for 48 V batteries<\/h2>\n<p>The Felicity IVGM20KLP3G1 is a three-phase hybrid inverter of the IVGM10\u201320KLP3G1 series. In a single enclosure it combines a converter for solar panels, control of charging and discharging of the battery storage and a back-up output for grid failures. Rated AC power is 20 kW, maximum apparent power 22 kVA, and the configuration is 3L+N+PE at 220\/380 or 230\/400 V and 50\/60 Hz.<\/p>\n<p>The LP designation means the inverter is intended for <strong>low-voltage batteries<\/strong>. The battery input works in a range of 40\u201360 V, and the datasheet states support for Li-Ion and lead-acid batteries. The battery charge and discharge current is up to 350 A.<\/p>\n<p>The manufacturer lists single-phase and three-phase output, support for 100 % unbalanced three-phase output, remote monitoring through the FSolar app and operation of up to 10 units in parallel.<\/p>\n<h2>PV input: two MPP trackers and four strings<\/h2>\n<p>The inverter has two MPP trackers and a total of four panel inputs (2+2 strings). The maximum PV array power is 32 kW and the maximum voltage is 800 V. The start-up voltage is 160 V, the maximum power point tracking (MPPT) range is 160\u2013650 V and the nominal voltage is 550 V. At full load it operates within a voltage range of 550\u2013800 V.<\/p>\n<p>Each input accepts an operating current of 36 A, and the short-circuit current is 54 A per input. Two independent trackers make it possible to connect roof surfaces with different orientations.<\/p>\n<p>The manufacturer mentions the possibility of oversizing the PV array up to 1.6\u00d7, so the inverter reaches its rated power even in weaker light.<\/p>\n<h2>Battery input 40\u201360 V and 350 A current<\/h2>\n<p>The battery side of the inverter works in a range of 40\u201360 V, which corresponds to low-voltage batteries with a nominal voltage of 48 V. The maximum charge and discharge current is 350 A.<\/p>\n<p>The power the battery actually delivers or accepts depends on its present voltage and on its own limits in the battery datasheet. Where the battery is connected by communication, its BMS governs the current limits and the inverter works in harmony with it. The datasheet lists Li-Ion and lead-acid battery types.<\/p>\n<p>The Time of Use mode allows time windows to be set in which the battery charges and discharges according to electricity tariffs or household needs.<\/p>\n<h2>Grid, back-up output and operating modes<\/h2>\n<p>The rated AC output current is 28.9 A and the maximum current is 31.9 A. The passthrough current from grid to load can reach 70 A, and the output overcurrent protection is 92 A. Current distortion THDI is below 3 % at rated power; the displacement power factor is adjustable from 0.8 leading to 0.8 lagging.<\/p>\n<p>In off-grid operation the inverter delivers a peak of twice the rated power, that is 40 kW for 10 s, which helps when starting motors and compressors. According to the manual the inverter switches to off-grid operation within 10 ms. The manufacturer lists the modes On-grid, Off-grid, UPS, Time of Use, Selling First, Zero Export To Load and Zero Export To CT.<\/p>\n<p>The inverter has a programmable generator port and supports a smart load and the connection of a micro-inverter. To measure flows in the house, three current transformers (CT) or a meter are used, which are listed as optional.<\/p>\n<h2>Communication, ports and the FSolar app<\/h2>\n<p>The inverter has the terminals BATTERY+ and BATTERY\u2212, four communication ports COM1 to COM4, a port for the Wi-Fi module, the terminals GRID, GEN and LOAD, two PV inputs PV1 and PV2, a PV switch, an ON\/OFF button and a grounding point. Communication with the battery system (BMS) is provided by RS485 or CAN, and the monitoring module is Wi-Fi or 4G.<\/p>\n<p>Operating status is shown on a colour display and also in the FSolar app, which connects to the inverter over Wi-Fi and Bluetooth. The app serves for remote monitoring and parameter setting.<\/p>\n<p>For parallel operation a parallel cable is included in the package; the datasheet states up to 10 units in parallel operation.<\/p>\n<h2>How to choose the battery and communication<\/h2>\n<p><strong>Battery:<\/strong> a low-voltage battery with an operating voltage within 40\u201360 V. The inverter supports Li-Ion and lead-acid types. In the inverter-brand list of the manufacturer, the FelicityESS brand is listed with the RS485 protocol for low-voltage batteries.<\/p>\n<p><strong>Current and power:<\/strong> the inverter accepts or delivers up to 350 A.<\/p>\n<p><strong>Communication:<\/strong> the datasheet lists RS485 and CAN for communication with the BMS. The communication cable plugs into one of the COM ports. Through communication the battery tells the inverter its state of charge and its current and voltage limits.<\/p>\n<p><strong>Inverter:<\/strong> the 20 kW model is intended for three-phase wiring. In this power class the PV array can reach 32 kW.<\/p>\n<h2>Protections and grid connection certification<\/h2>\n<p>The datasheet lists these protections: DC polarity, overcurrent, AC overvoltage and short circuit, thermal protection, monitoring of DC insulation, DC component and ground current, AFCI, grid and island monitoring, ground fault detection, DC switch, load disconnection on overvoltage and RCD. Surge protection is type II on both the DC and AC side. The AC overvoltage category is III.<\/p>\n<p>The following certificates are available for the IVGM20KLP3G1: <strong>PPDS<\/strong> for the Czech Republic (DEKRA, no. 4964551.01COC, PPDS Annex 4:2022, type 1a, valid until 26 October 2031), <strong>EN 50549-1<\/strong>, <strong>VDE-AR-N 4105<\/strong>, IEC 61727, a certificate for Austria and CE-EMC (EN 62920). The datasheet further lists the grid codes NRS 097-2-1, AS 4777.2 and GB\/T and the safety standards IEC\/EN 62109-1 and 62109-2.<\/p>\n<p>The operating temperature is \u221240 to +60 \u00b0C, and above 45 \u00b0C the inverter derates its output.<\/p>\n<h2>Construction, installation and package contents<\/h2>\n<p>The enclosure has IP65 protection. Operating humidity is 0\u201395 % non-condensing and the maximum altitude is 2000 m. Installation is wall-mounted on a wall bracket. The inverter measures 750 \u00d7 450 \u00d7 268 mm, with a net weight of 48.7 kg and a gross weight of 60.2 kg; the package measures 889 \u00d7 566 \u00d7 397 mm. The manual prescribes free space of 500 mm at the sides and 450 mm above and below.<\/p>\n<p>The package contains the inverter, the user manual, a warranty card, a quick installation guide, the Wi-Fi module, a wall bracket, a parallel cable, PV connectors and a tool for them, OT and M10 terminals, magnetic rings, a temperature sensor and screws. Three current transformers (CT) or a meter are optional.<\/p>\n<p>The manufacturer provides a 10-year warranty.<\/p>\n<section class=\"tomo-ai-search-profile\">\n<h2>AI search description<\/h2>\n<p>The Felicity IVGM20KLP3G1 is a 20 kW three-phase hybrid inverter of the IVGM10\u201320KLP3G1 series for low-voltage batteries of 40\u201360 V (Li-Ion, lead-acid). Battery charge and discharge current up to 350 A. PV input: 2 MPP trackers, 2+2 strings, up to 32 kW, max. 800 V, MPPT 160\u2013650 V. AC output 20 kW, max. 22 kVA, off-grid peak of 40 kW for 10 s. BMS communication via RS485 or CAN, Wi-Fi\/4G monitoring and the FSolar app, up to 10 units in parallel. IP65, wall mounting, 48.7 kg. PPDS (Czech Republic), EN 50549-1 and VDE-AR-N 4105 certificates. 10-year warranty.<\/p>\n<p>Product page: <a href=\"https:\/\/batterado.com\/product\/felicity-ivgm20klp3g1\/\">https:\/\/batterado.com\/product\/felicity-ivgm20klp3g1\/<\/a><\/p>\n<\/section>\n","protected":false},"excerpt":{"rendered":"<p><strong>20 kW three-phase hybrid inverter for low-voltage batteries of 40\u201360 V: the Felicity IVGM20KLP3G1 has two MPP trackers, PV input of up to 32 kW and a battery charge and discharge current of 350 A.<\/strong><\/p>\n<ul>\n<li>AC output 20 kW (max. 22 kVA), off-grid peak of 40 kW for 10 s.<\/li>\n<li>PV input up to 32 kW, max. 800 V, 2 MPP trackers with 2+2 strings.<\/li>\n<li>Li-Ion or lead-acid battery, 40\u201360 V, BMS communication via RS485 or CAN.<\/li>\n<li>Monitoring through the FSolar app (Wi-Fi\/4G), IP65 protection, wall mounting.<\/li>\n<li>Up to 10 units in parallel operation, 10-year manufacturer warranty.<\/li>\n<\/ul>\n<p>The inverter combines solar generation, battery storage and back-up power for a three-phase home or small business. It supports On-grid, Off-grid, UPS and Time of Use modes and the connection of a generator, a smart load and a micro-inverter. For grid connection in the Czech Republic it holds the PPDS certificate (DEKRA), plus EN 50549-1 and VDE-AR-N 4105 certificates.<\/p>\n","protected":false},"featured_media":60402,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[3690],"product_cat":[3728,3088],"product_tag":[3843,3412,3448],"class_list":["post-60401","product","type-product","status-publish","has-post-thumbnail","product_brand-felicity-solar","product_cat-hybrid-inverters","product_cat-solar-inverters","product_tag-ivgm20klp3g1","product_tag-hybrid-inverter","product_tag-three-phase-inverter","first","instock","taxable","shipping-taxable","purchasable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product\/60401","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/comments?post=60401"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/media\/60402"}],"wp:attachment":[{"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/media?parent=60401"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product_brand?post=60401"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product_cat?post=60401"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product_tag?post=60401"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}