{"id":59761,"date":"2026-11-04T11:44:00","date_gmt":"2026-11-04T09:44:00","guid":{"rendered":"https:\/\/batterado.com\/?post_type=product&#038;p=59761"},"modified":"2026-11-21T15:46:55","modified_gmt":"2026-11-21T13:46:55","slug":"felicity-solar-11-52kwp-10kw-8-75kwh-solar-kit","status":"publish","type":"product","link":"https:\/\/batterado.com\/en\/product\/felicity-solar-11-52kwp-10kw-8-75kwh-solar-kit\/","title":{"rendered":"Felicity Solar T-REX + AIKO \u2014 11.52 kWp, 10 kW, 8.75 kWh"},"content":{"rendered":"<figure class=\"batterado-energy-journey\"><picture><source media=\"(max-width:600px)\" srcset=\"https:\/\/batterado.com\/wp-content\/uploads\/batterado-journey-20261112\/journey-59761-en-mobile.webp\" width=\"900\" height=\"1740\"><img decoding=\"async\" src=\"https:\/\/batterado.com\/wp-content\/uploads\/batterado-journey-20261112\/journey-59761-en.webp\" alt=\"Felicity + AIKO 11.52 kWp \u2014 8.75 kWh. Store energy \u2192 Transport components \u2192 Use at the installation site. Illustrative use and handling diagram.\" width=\"1800\" height=\"900\" loading=\"lazy\" style=\"width:100%;height:auto\"><\/picture><figcaption>Illustrative use and handling diagram<\/figcaption><\/figure>\n<h2>BATTERADO \u2014 Energy with you.<\/h2>\n<p>Nominal storage energy 8.75 kWh.<\/p>\n<p class=\"batterado-energy-use\">Energy generated by the supplied solar panels can be stored in the battery and used later by selected circuits in the building. The inverter connects generation, storage and consumption at the installation site. The capacity shown above the table is the nominal energy of the complete battery bank offered here. Individual components can be moved to their installation position with suitable handling equipment. Our <a href=\"https:\/\/batterado.com\/en\/product\/batterado-prepravni-vozik-150-kg-pro-power-stations\/\">BATTERADO 150 kg transport trolley<\/a> is available for individual components weighing up to 150 kg.<\/p>\n<h2>Technical specifications<\/h2>\n<div class=\"wt-technical-grid\" style=\"display:flex;flex-wrap:wrap;gap:20px;align-items:flex-start\">\n<table style=\"flex:1 1 300px;width:100%;min-width:0;table-layout:fixed;overflow-wrap:anywhere\">\n<thead>\n<tr>\n<th>Parameter<\/th>\n<th>Value<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">PV array<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">11.52 kWp<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">Inverter<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">T-REX-10KLP3G01, 10 kW<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">Battery storage<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">8.75 kWh<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">Solar panels<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">24 \u00d7 480 W<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">Battery modules<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">1<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">Battery chemistry<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">LiFePO4<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">Inverter \/ AC<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">3L + N + PE, 230\/400 V<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">Inverter battery input<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">40\u201360 V DC; 200 A<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">Battery charge\/discharge current<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">120 A \/ 120 A<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">MPPT voltage range<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">200\u2013850 V DC<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">Maximum PV input power<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">13 kW<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">MPPT<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">2<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">PV max.<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">900 V<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">CAN \/ RS485<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">BMS<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">T-REX IP<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">IP65<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">AIKO<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">Neostar 3S+54 480 W<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">Felicity<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">FLA48171-EU<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">Nominal energy<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">8.75 kWh<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">Maximum continuous battery power<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">6000 W<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">Rated capacity<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">171 Ah \/ 51.2 V<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">Battery operating voltage<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">44.8\u201357.6 V<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">Charging temperature<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">0\u201355 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">Discharging temperature<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">\u221220\u201355 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">Battery protection rating<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">IP21<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">Depth of discharge<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">\u226595%<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">Parallel expansion<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">15 \u00d7 FLA48171-EU; 131.25 kWh (15 \u00d7 8.75 kWh)<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">Cycle life<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">\u22656000<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">Battery communication<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">CAN \/ RS485<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">Mounting<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">Wall \/ floor<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">AIKO<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">AIKO-A480-MCE54Db, N-type ABC, 108 (6 \u00d7 18)<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">AIKO STC<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">480 W; Voc 40.90 V; Vmp 34.50 V; Isc 14.80 A; Imp 13.92 A; 24.0%<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">AIKO NOCT<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">364 W; Voc 38.80 V; Vmp 32.73 V; Isc 11.96 A; Imp 11.13 A<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">AIKO mm \/ kg<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">1762 \u00d7 1134 \u00d7 30 mm; 24.2 kg \u00b13%<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">AIKO<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">2 + 2 mm; IP68; 3 diodes; MC4; 4 mm\u00b2 \/ 12 AWG \/ 1200 mm<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">AIKO \u00b0C<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">\u221240\u201385 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">AIKO Isc \/ Voc \/ Pmax<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">+0.05 \/ \u22120.22 \/ \u22120.26 %\/\u00b0C<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">AIKO max.<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">1500 V DC; 30 A<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">AIKO Pa<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">5400 \/ 2400 Pa<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table style=\"flex:1 1 300px;width:100%;min-width:0;table-layout:fixed;overflow-wrap:anywhere\">\n<thead>\n<tr>\n<th>Parameter<\/th>\n<th>Value<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">AIKO<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">Class II; IEC fire class A<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">T-REX PV<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">900 V max.; start 180 V; nominal 720 V; MPPT 200\u2013850 V<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">T-REX MPPT<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">2 MPPT; 1 string\/MPPT; 15 A\/MPPT; Isc 18 A\/MPPT<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">T-REX: BMS connector, pins 1\u20138<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">\u2014 \/ CANL1 \/ +VCC \/ COM-GND \/ RS485-B1 \/ RS485-A1 \/ CANH1 \/ \u2014<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">T-REX: battery selection<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">App: Lithium; LCD: Li; BMS indicator confirms communication<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">T-REX: COM, pins 1\u20136<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">RYL4 \/ RYL5 \/ RS485B3 \/ RS485A3 \/ RS485A2 \/ RS485B2<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">T-REX: metering \/ dry contact<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">Meter with CT according to wiring diagram; contact max. 3 A \/ 250 V AC<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">T-REX: DRM, pins 1\u20138<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">DRM1\/5 \/ DRM2\/6 \/ DRM3\/7 \/ DRM4\/8 \/ REF \/ COM \/ \u2014 \/ \u2014<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">Battery: peak current (15 s)<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">150 A<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">Battery: dimensions \/ packaging<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">735 \u00d7 433 \u00d7 188 mm \/ 849 \u00d7 550 \u00d7 362 mm<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">Battery: net weight<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">68 kg<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">Battery: protection<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">BMS, circuit breaker, fuse, aerosol suppression system<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">Battery: local and remote monitoring<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">LCD + LED; Wi-Fi \/ Bluetooth<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">Battery: power lead specified in manual<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">0.9 m \/ 35 mm\u00b2 \/ 150 A<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">Battery: CAN\/RS485 connector, pins 1\u20138<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">CAN-GND \/ +5V-BUS \/ CANL-PCS \/ CANH-PCS \/ RS485-B \/ RS485-A \/ CANL \/ CANH<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">Battery: RS485 application profile in manual<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">Felicity IVCM, IVEM, IVPS\/M, IVGM and others; grey lead specified in manual<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">Battery: settings without communication<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">Maximum \/ float voltage 57.6 V; cutoff 48 V; maximum charging 120 A per module<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">T-REX: charge \/ discharge power<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">10 000 W \/ 10 000 W<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">T-REX: PV operating range \/ full-load MPPT<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">160\u2013900 V \/ 450\u2013850 V<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">T-REX: grid input<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">L1\/L2\/L3\/N\/PE; 230\/400 V AC; 184\u2013264.5 V AC; 50\/60 Hz<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">T-REX: max. input current \/ AC passthrough<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">30 A \/ 30 A<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">T-REX: rated \/ max. AC output current<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">14.5 A \/ 18 A<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">T-REX: power factor \/ displacement range<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">&gt;0.99 \/ 0.8 leading \u2026 0.8 lagging<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">T-REX: THD<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">&lt;3%<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">T-REX: backup output<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">10 000 VA \/ 10 000 W; L1\/L2\/L3\/N\/PE; 230\/400 V AC; 50\/60 Hz; max. 30 A<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">T-REX: max. \/ European \/ MPPT efficiency<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">97.6% \/ 97.0% \/ 99.9%<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">T-REX: protective functions<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">Overcurrent, overload, short circuit, anti-islanding, GFCI, insulation resistance detection<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">T-REX: temperature \/ power management<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">\u221225 to +60\u00b0C; derating above 45\u00b0C<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">T-REX: humidity \/ altitude<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">100% \/ 2 000 m<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">T-REX: system communication \/ BMS<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">RS232 \/ RS485; BMS: CAN \/ RS485<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">T-REX: monitoring \/ display<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">Wi-Fi\/GPRS; LCD + LED<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">T-REX: dimensions \/ packaging<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">655 \u00d7 475 \u00d7 266 mm \/ 792 \u00d7 597 \u00d7 351 mm<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">T-REX: net \/ packed weight<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">38.9 kg \/ 47.1 kg<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">T-REX: grid standards listed in datasheet<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">VDE-AR-N 4105; G99\/1; EN 50549-1; CEI 0-21; AS 4777.2; NRS 097-2-1<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">T-REX: safety \/ EMC listed in datasheet<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">IEC 62109-1 \/ IEC 62040-1; EN 61000-6-1 \/ EN 61000-6-3<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">AIKO: hail test \/ dimensional tolerance<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">35 mm \/ 23 m\/s; L \u00b12 mm, W \u00b12 mm<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">AIKO: STC \/ NOCT conditions<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">AM1.5, 1 000 W\/m\u00b2, 25 \u00b0C \/ AM1.5, 800 W\/m\u00b2, 20 \u00b0C, 1 m\/s<\/td>\n<\/tr>\n<tr>\n<th style=\"border-bottom:1px solid #ddd;padding:9px;text-align:left\">AIKO: power degradation<\/th>\n<td style=\"border-bottom:1px solid #ddd;padding:9px\">Year 1 \u22641%; from year 2 \u22640.35% per year<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2>Three-phase solar generation with stored energy<\/h2>\n<p>This configuration combines 24 AIKO Neostar 3S+54 full-black 480 W modules, a Felicity T-REX-10KLP3G01 three-phase hybrid inverter and one FLA48171-EU battery. The array has a nominal output of 11.52 kWp, the inverter is rated at 10 kW and the battery stores 8.75 kWh of nominal energy. Each component has a distinct role: the modules generate electricity, the inverter manages conversion and the battery makes solar energy available at a later time. The combination suits a three-phase installation in a home, small business or workshop.<\/p>\n<p>The hybrid architecture connects photovoltaic inputs, a low-voltage battery, the utility supply and a dedicated backup output. Installation design and operating settings determine how energy is used directly, stored and supplied to selected circuits. Two independent MPPT trackers allow two PV strings to operate at their respective maximum power points. This is useful when dividing the array between roof areas with different orientations.<\/p>\n<h2>AIKO ABC modules with a uniform black finish<\/h2>\n<p>The AIKO-A480-MCE54Db module uses N-type ABC cells and a dual-glass construction with 2 + 2 mm glass. Its black anodised aluminium frame and full-black appearance create a consistent roof surface. The 480 W rating and 24.0% efficiency refer to standard test conditions, or STC. Twenty-four modules provide a combined nameplate rating of 11,520 Wp. Actual energy production depends on irradiation, module temperature, orientation and shading at the installation site.<\/p>\n<p>Each module measures 1,762 \u00d7 1,134 \u00d7 30 mm and weighs 24.2 kg with a tolerance of \u00b13%. These figures support roof layout and mounting-system selection. The IP68 junction box incorporates three bypass diodes. Original MC4 connectors and 4 mm\u00b2 cables provide the electrical connections. The stated front and rear static load ratings are 5,400 Pa and 2,400 Pa respectively under the manufacturer&#8217;s mounting conditions. The roof design also accounts for support positions and local loading.<\/p>\n<p>A power temperature coefficient of \u22120.26%\/\u00b0C describes how output changes as cell temperature increases. Electrical design also uses the 40.90 V open-circuit voltage, 34.50 V maximum-power voltage and \u22120.22%\/\u00b0C voltage temperature coefficient. These values, together with the site&#8217;s minimum design temperature, determine a suitable string length. The NOCT figures in the technical table describe a second defined set of test conditions and provide additional context when assessing module operation.<\/p>\n<h2>T-REX hybrid conversion across three phases<\/h2>\n<p>The T-REX-10KLP3G01 supports a 230\/400 V three-phase connection and two MPPT inputs, each accommodating one PV string. Its MPPT operating range is 200\u2013850 V, starting voltage is 180 V and maximum PV voltage is 900 V. The datasheet specifies a maximum recommended PV array power of 13 kW. Each tracker handles an operating current of 15 A and a short-circuit current of 18 A.<\/p>\n<p>A dedicated backup AC output is rated at 10,000 VA \/ 10,000 W. The selected backup circuits are designed around simultaneous loads and the power available from the connected energy sources. Maximum conversion efficiency is 97.6%, European efficiency is 97.0% and MPPT efficiency is 99.9%. These figures describe different aspects of inverter performance. An energy assessment for the complete system also considers battery operation, conversion losses and the timing of demand.<\/p>\n<p>The wall-mounted inverter measures 655 \u00d7 475 \u00d7 266 mm and weighs 38.9 kg. Its IP65 enclosure and operating range of \u221225 to +60\u00b0C provide installation flexibility; the manufacturer specifies power derating above 45\u00b0C. Smart cooling responds to operating conditions. An LCD and LED indicators give local status information. Wi-Fi\/GPRS monitoring-module support and the listed communication interfaces provide further integration options. The installation position includes suitable access and ventilation clearance.<\/p>\n<h2>FLA48171-EU storage for later consumption<\/h2>\n<p>The battery uses LiFePO4 chemistry and a nominal voltage of 51.2 V, with 8.75 kWh of nominal energy in one module. Its integrated BMS manages battery operation alongside a circuit breaker and fuse. Local LCD and LED indicators show operating information. The battery manual also describes built-in Wi-Fi\/Bluetooth monitoring and an aerosol fire-suppression system. Together these features form a managed battery unit that exchanges operating information with the hybrid inverter.<\/p>\n<p>The battery&#8217;s maximum continuous charge and discharge current is 120 A. Its peak rating is 150 A for 15 seconds, while maximum charge and discharge power is specified as 6,000 W. These battery limits determine the design when one module is supplying the installation. The inverter&#8217;s 10 kW rating and the battery&#8217;s 6 kW rating describe separate components. Available system output depends on the operating mode and the energy supplied simultaneously by the PV array, battery and grid.<\/p>\n<p>An indoor location matching the battery&#8217;s IP21 rating is required. Charging temperature is 0 to 55\u00b0C and discharging temperature is \u221220 to 55\u00b0C. The manufacturer provides for wall mounting or floor installation with the specified restraints. At 735 \u00d7 433 \u00d7 188 mm, the unit can be incorporated into a utility-room layout. Positioning considers structural support, access to connectors and the routes taken by power and communication cables.<\/p>\n<h2>Communication and expansion<\/h2>\n<p>CAN or RS485 communication links the battery management system to the inverter using the appropriate wiring and configuration. The battery manual distinguishes inverter communication leads from the cable used between battery modules. LINK connections and address switches organise a parallel battery bank. The locally hosted manual contains the connector pin assignments. Commissioning uses the lead and settings intended for the installed equipment combination.<\/p>\n<p>The battery family supports up to 15 modules connected in parallel. Fifteen modules at the stated 8.75 kWh nominal energy give a calculated total of 131.25 kWh. This is an expansion capability of the battery family and requires suitably designed busbars, protection and connected equipment. The offered base configuration contains one battery. Additional modules can increase stored energy as demand develops and as permitted by the complete installation design.<\/p>\n<h2>A defined set of main components<\/h2>\n<p>The base offer consists of 24 AIKO-A480-MCE54Db modules, one Felicity T-REX-10KLP3G01 hybrid inverter and one FLA48171-EU battery. A mounting structure is selected for the actual roof and forms a separate part of project design. Installation cable lengths and distribution equipment are likewise chosen for the building. The technical documents below support component positioning, electrical planning and space allocation before installation. They also keep panel, inverter and battery specifications clearly separated when comparing configurations.<\/p>\n<h2>Downloads<\/h2>\n<ul>\n<li><a href=\"https:\/\/batterado.com\/wp-content\/uploads\/solar-kits-20261104\/fla48171-cs.pdf\">FLA48171-EU \u2014 n\u00e1vod (CS)<\/a><\/li>\n<li><a href=\"https:\/\/batterado.com\/wp-content\/uploads\/solar-kits-20261104\/fla48171-de.pdf\">FLA48171-EU \u2014 Benutzerhandbuch (DE)<\/a><\/li>\n<li><a href=\"https:\/\/batterado.com\/wp-content\/uploads\/solar-kits-20261104\/aiko480-datasheet.pdf\">AIKO-A480-MCE54Db \u2014 Datenblatt (DE)<\/a><\/li>\n<li><a href=\"https:\/\/batterado.com\/wp-content\/uploads\/solar-kits-20261104\/trex10-datasheet-en.pdf\">T-REX-10KLP3G01 \u2014 datasheet (EN)<\/a><\/li>\n<li><a href=\"https:\/\/batterado.com\/wp-content\/uploads\/solar-kits-20261104\/trex10-manual-en.pdf\">T-REX-10KLP3G01 \u2014 user guide (EN)<\/a><\/li>\n<li><a href=\"https:\/\/batterado.com\/wp-content\/uploads\/solar-kits-20261104\/solar-kit-59761-en.md\">Product overview \u2014 Markdown (.md)<\/a><\/li>\n<\/ul>\n<section class=\"batterado-product-details\">\n<h2>Views and dimensions<\/h2>\n<\/section>\n<section class=\"tomo-ai-search-profile\">\n<h2>AI search description<\/h2>\n<p>This three-phase hybrid configuration combines an 11.52 kWp array of full-black AIKO modules with a 10 kW Felicity T-REX inverter and an 8.75 kWh FLA48171-EU battery. Two MPPT inputs independently manage two PV strings, while the battery stores energy for later consumption. The offer comprises 24 AIKO-A480-MCE54Db dual-glass N-type ABC modules, one T-REX-10KLP3G01 and one LiFePO4 battery module. The inverter provides grid and dedicated backup connections at 230\/400 V. The battery has its own BMS, LCD and LED indication, with CAN or RS485 communication and a maximum continuous power rating of 6 kW. The battery is rated IP21 for indoor use, and the wall-mounted inverter has IP65 protection. The system suits a home, small business or workshop with a three-phase supply. Roof mounting and installation equipment are selected for the individual building.<\/p>\n<p><a href=\"https:\/\/batterado.com\/en\/product\/felicity-solar-11-52kwp-10kw-8-75kwh-solar-kit\/\">https:\/\/batterado.com\/en\/product\/felicity-solar-11-52kwp-10kw-8-75kwh-solar-kit\/<\/a><\/p>\n<\/section>\n","protected":false},"excerpt":{"rendered":"<p>This three-phase hybrid configuration combines an 11.52 kWp array of full-black AIKO modules with a 10 kW Felicity T-REX inverter and an 8.75 kWh FLA48171-EU battery. Two MPPT inputs independently manage two PV strings, while the battery stores energy for later consumption. The offer comprises 24 AIKO-A480-MCE54Db dual-glass N-type ABC modules, one T-REX-10KLP3G01 and one LiFePO4 battery module. The inverter provides grid and dedicated backup connections at 230\/400 V. The battery has its own BMS, LCD and LED indication, with CAN or RS485 communication and a maximum continuous power rating of 6 kW. The battery is rated IP21 for indoor use, and the wall-mounted inverter has IP65 protection. The system suits a home, small business or workshop with a three-phase supply. Roof mounting and installation equipment are selected for the individual building.<\/p>\n","protected":false},"featured_media":59762,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[3690],"product_cat":[3424],"product_tag":[3812,3811,3813,3810],"class_list":["post-59761","product","type-product","status-publish","has-post-thumbnail","product_brand-felicity-solar","product_cat-fotovoltaicke-komplety","product_tag-aiko-a480-mce54db","product_tag-fla48171-eu","product_tag-hybridni-fotovoltaicke-sestavy","product_tag-felicity-t-rex-10klp3g01","first","instock","purchasable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product\/59761","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/comments?post=59761"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/media\/59762"}],"wp:attachment":[{"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/media?parent=59761"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product_brand?post=59761"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product_cat?post=59761"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product_tag?post=59761"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}