{"id":59292,"date":"2026-11-01T07:25:28","date_gmt":"2026-11-01T05:25:28","guid":{"rendered":"https:\/\/batterado.com\/?post_type=product&#038;p=59292"},"modified":"2026-11-01T13:51:53","modified_gmt":"2026-11-01T11:51:53","slug":"huawei-sun2000-12k-map0-asymetricky-hybridni-stridac","status":"publish","type":"product","link":"https:\/\/batterado.com\/en\/product\/huawei-sun2000-12k-map0-asymetricky-hybridni-stridac\/","title":{"rendered":"Huawei SUN2000-12K-MAP0 \u2014 12 kW asymmetric three-phase hybrid inverter"},"content":{"rendered":"<h2>Technical specifications<\/h2>\n<div class=\"wt-tech-grid\">\n<table>\n<tbody>\n<tr>\n<th>Manufacturer<\/th>\n<td>Huawei<\/td>\n<\/tr>\n<tr>\n<th>Model<\/th>\n<td>SUN2000-12K-MAP0<\/td>\n<\/tr>\n<tr>\n<th>Type and role<\/th>\n<td>Three-phase hybrid PV inverter for external high-voltage storage<\/td>\n<\/tr>\n<tr>\n<th>Rated AC output<\/th>\n<td>12 kW<\/td>\n<\/tr>\n<tr>\n<th>Maximum apparent AC output<\/th>\n<td>13200 VA<\/td>\n<\/tr>\n<tr>\n<th>Grid voltage<\/th>\n<td>220\/380 V \/230\/400 V \/240\/415 V \/3L+N+PE<\/td>\n<\/tr>\n<tr>\n<th>Grid frequency<\/th>\n<td>50 \/60 Hz<\/td>\n<\/tr>\n<tr>\n<th>Maximum AC current<\/th>\n<td>20.2 A \/380 V<\/td>\n<\/tr>\n<tr>\n<th>Power factor<\/th>\n<td>0.8 leading\u20260.8 lagging<\/td>\n<\/tr>\n<tr>\n<th>THD at rated output<\/th>\n<td>\u22643 %<\/td>\n<\/tr>\n<tr>\n<th>Recommended maximum PV power<\/th>\n<td>22000 Wp<\/td>\n<\/tr>\n<tr>\n<th>Maximum DC voltage<\/th>\n<td>1100 V<\/td>\n<\/tr>\n<tr>\n<th>Start-up voltage<\/th>\n<td>160 V<\/td>\n<\/tr>\n<tr>\n<th>MPPT range<\/th>\n<td>160\u20131000 V<\/td>\n<\/tr>\n<tr>\n<th>Rated DC voltage<\/th>\n<td>600 V<\/td>\n<\/tr>\n<tr>\n<th>MPPT count<\/th>\n<td>2<\/td>\n<\/tr>\n<tr>\n<th>Strings per MPPT<\/th>\n<td>1<\/td>\n<\/tr>\n<tr>\n<th>PV string count<\/th>\n<td>2<\/td>\n<\/tr>\n<tr>\n<th>Current per MPPT<\/th>\n<td>16 A<\/td>\n<\/tr>\n<tr>\n<th>Short-circuit current per MPPT<\/th>\n<td>22 A<\/td>\n<\/tr>\n<tr>\n<th>Maximum efficiency<\/th>\n<td>98.6 %<\/td>\n<\/tr>\n<tr>\n<th>European efficiency<\/th>\n<td>98.2 %<\/td>\n<\/tr>\n<tr>\n<th>Battery interface \u2014 manual voltage range<\/th>\n<td>600\u2013980 V DC<\/td>\n<\/tr>\n<tr>\n<th>Maximum battery current<\/th>\n<td>20 A<\/td>\n<\/tr>\n<tr>\n<th>Maximum battery charging power<\/th>\n<td>12 kW<\/td>\n<\/tr>\n<tr>\n<th>Maximum discharge power per specification<\/th>\n<td>12000 W<\/td>\n<\/tr>\n<tr>\n<th>Rated three-phase backup output<\/th>\n<td>12000 W \/3-phase<\/td>\n<\/tr>\n<tr>\n<th>Ingress protection<\/th>\n<td>IP66<\/td>\n<\/tr>\n<tr>\n<th>Operating temperature<\/th>\n<td>\u221225\u2026+60 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th>Operating relative humidity<\/th>\n<td>0\u2013100 %<\/td>\n<\/tr>\n<tr>\n<th>Operating altitude<\/th>\n<td>0\u20134000 m<\/td>\n<\/tr>\n<tr>\n<th>Weight including bracket<\/th>\n<td>\u226421 kg<\/td>\n<\/tr>\n<tr>\n<th>Dimensions W \u00d7 H \u00d7 D including bracket<\/th>\n<td>490 \u00d7460 \u00d7130 mm<\/td>\n<\/tr>\n<tr>\n<th>Standard communication<\/th>\n<td>RS485; local WLAN for commissioning<\/td>\n<\/tr>\n<tr>\n<th>Built-in WLAN<\/th>\n<td>802.11b\/g\/n \/2400\u20132483.5 MHz<\/td>\n<\/tr>\n<tr>\n<th>Reference AC protection<\/th>\n<td>32 A \/\u2265415 V AC \/3-phase<\/td>\n<\/tr>\n<tr>\n<th>DC conductors<\/th>\n<td>4\u20136 mm\u00b2 Cu<\/td>\n<\/tr>\n<tr>\n<th>Battery conductors<\/th>\n<td>4\u20136 mm\u00b2 Cu<\/td>\n<\/tr>\n<tr>\n<th>AC conductors<\/th>\n<td>4\u20136 mm\u00b2 Cu<\/td>\n<\/tr>\n<tr>\n<th>PE conductor<\/th>\n<td>4\u20136 mm\u00b2 Cu<\/td>\n<\/tr>\n<tr>\n<th>Grid systems<\/th>\n<td>TN-S \/TN-C \/TN-C-S \/TT \/IT<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<th>Safety standards<\/th>\n<td>EN\/IEC62109-1 \/EN\/IEC62109-2<\/td>\n<\/tr>\n<tr>\n<th>Cooling<\/th>\n<td>Natural convection<\/td>\n<\/tr>\n<tr>\n<th>Topology<\/th>\n<td>Transformerless<\/td>\n<\/tr>\n<tr>\n<th>Local control<\/th>\n<td>LED \/WLAN \/FusionSolar App for configuration<\/td>\n<\/tr>\n<tr>\n<th>Supported battery systems<\/th>\n<td>LUNA2000-5\/10\/15-S0 \/LUNA2000-7\/14\/21-S1<\/td>\n<\/tr>\n<tr>\n<th>Battery assembly<\/th>\n<td>Compatible modules with matching power and control module<\/td>\n<\/tr>\n<tr>\n<th>Storage capacity<\/th>\n<td>Defined by the selected complete battery in kWh<\/td>\n<\/tr>\n<tr>\n<th>Battery charging from grid<\/th>\n<td>Supported with appropriate configuration<\/td>\n<\/tr>\n<tr>\n<th>Backup system pairing<\/th>\n<td>LUNA2000 +SmartGuard-63A-T0<\/td>\n<\/tr>\n<tr>\n<th>Ethernet connection<\/th>\n<td>With a separate WLAN-FE Smart Dongle<\/td>\n<\/tr>\n<tr>\n<th>Mobile data connection<\/th>\n<td>Optional compatible 4G Smart Dongle<\/td>\n<\/tr>\n<tr>\n<th>Energy metering<\/th>\n<td>DTSU666-H \/YDS60-C24 \/DTSU71 \/DHSU1079-CT according to firmware and design<\/td>\n<\/tr>\n<tr>\n<th>Additional control<\/th>\n<td>SmartAssistant \/SmartGuard-63A-T0 according to design<\/td>\n<\/tr>\n<tr>\n<th>PV optimizers<\/th>\n<td>Optional according to approved string layout<\/td>\n<\/tr>\n<tr>\n<th>Anti-islanding protection<\/th>\n<td>Integrated<\/td>\n<\/tr>\n<tr>\n<th>DC polarity protection<\/th>\n<td>Integrated<\/td>\n<\/tr>\n<tr>\n<th>Insulation monitoring<\/th>\n<td>Integrated<\/td>\n<\/tr>\n<tr>\n<th>Residual current monitoring<\/th>\n<td>Integrated<\/td>\n<\/tr>\n<tr>\n<th>AC overcurrent and short circuit<\/th>\n<td>Integrated<\/td>\n<\/tr>\n<tr>\n<th>Temperature protection<\/th>\n<td>Integrated<\/td>\n<\/tr>\n<tr>\n<th>AFCI arc-fault protection<\/th>\n<td>Integrated<\/td>\n<\/tr>\n<tr>\n<th>Surge protection<\/th>\n<td>DC and AC, Type II-compatible according to specification<\/td>\n<\/tr>\n<tr>\n<th>Mounting<\/th>\n<td>Fixed wall installation<\/td>\n<\/tr>\n<tr>\n<th>Offered scope<\/th>\n<td>Individual inverter with system interfaces for external components<\/td>\n<\/tr>\n<tr>\n<th>Estimated delivery<\/th>\n<td>2\u20133 days, seller estimate<\/td>\n<\/tr>\n<tr>\n<th>PV input allocation design<\/th>\n<td>One or two appropriately designed strings<\/td>\n<\/tr>\n<tr>\n<th>Storage temperature<\/th>\n<td>\u221240\u2026+70 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th>Typical noise<\/th>\n<td>\u226429 dB<\/td>\n<\/tr>\n<tr>\n<th>Night consumption<\/th>\n<td>&lt;5.5 W<\/td>\n<\/tr>\n<tr>\n<th>Battery operating range per datasheet<\/th>\n<td>600\u2013980 V DC<\/td>\n<\/tr>\n<tr>\n<th>Remote monitoring<\/th>\n<td>With suitable Smart Dongle or system network equipment<\/td>\n<\/tr>\n<tr>\n<th>Asymmetric control<\/th>\n<td>Supports100% three-phase imbalance according to specification and phase limits<\/td>\n<\/tr>\n<tr>\n<th>Long-term backup output<\/th>\n<td>13200 W \/110 %<\/td>\n<\/tr>\n<tr>\n<th>150% backup overload \u2014 three phases<\/th>\n<td>1 min<\/td>\n<\/tr>\n<tr>\n<th>150% backup overload \u2014 single phase<\/th>\n<td>5 min<\/td>\n<\/tr>\n<tr>\n<th>200% backup overload \u2014 three phases<\/th>\n<td>10 s<\/td>\n<\/tr>\n<tr>\n<th>Transfer with SmartGuard<\/th>\n<td>\u226420 ms \/SmartGuard-63A-T0<\/td>\n<\/tr>\n<tr>\n<th>Connector temperature monitoring<\/th>\n<td>PV \/battery<\/td>\n<\/tr>\n<tr>\n<th>PID recovery<\/th>\n<td>Supported<\/td>\n<\/tr>\n<tr>\n<th>Battery signal cable<\/th>\n<td>Cat5e outdoor shielded<\/td>\n<\/tr>\n<tr>\n<th>PV configuration requirement<\/th>\n<td>Direct modules or compatible optimization according to design<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2>Asymmetric solar and three-phase backup<\/h2>\n<p>Huawei SUN2000-12K-MAP0 is an asymmetric three-phase hybrid inverter rated at 12 kW, with two MPPTs and an interface for complete LUNA2000 storage. It supports different loads on individual phases within total-output and phase-current limits. With a compatible battery and SmartGuard-63A-T0, it forms an engineered three-phase backup system. Optimizers can be selected according to the actual array design.<\/p>\n<h2>Two strings matched to the roof<\/h2>\n<p>The manufacturer recommends up to 22000 Wp of PV for this model. Each of the two MPPTs has one string input, with 16 A input and 22 A short-circuit limits according to the actual nameplate version. The design assigns modules by orientation, tilt, operating current and voltage, allowing two appropriately designed roof sections to track independently.<\/p>\n<h2>PV voltage design<\/h2>\n<p>MPPT operates over 160\u20131000 V, with 600 V nominal input and 160 V start-up voltage. Maximum DC voltage is 1100 V. Series module count is checked against cold open-circuit voltage and the actual input-current limit. Compatible optimizers can be incorporated according to their exact family, firmware and approved layout.<\/p>\n<h2>Output for a three-phase system<\/h2>\n<p>Rated three-phase output is 12 kW, with 13200 VA maximum apparent output. The family supports 100% three-phase imbalance according to specification; design still accounts for total output and each phase current. This model reaches 98.6% maximum and 98.2% European efficiency. Appropriate metering and control coordinate generation, phase-specific demand and configured grid requirements.<\/p>\n<h2>LUNA2000 storage as part of the assembly<\/h2>\n<p>Supported systems include LUNA2000-5\/10\/15-S0 and LUNA2000-7\/14\/21-S1 according to the current specification and appropriate configuration. Battery modules are combined with the correct power and control module for their generation. Capacity in kWh follows the selected complete battery; inverter output in kW describes a different property. Protection, communication and firmware form part of the design.<\/p>\n<h2>Charging from solar and grid<\/h2>\n<p>The 600\u2013980 V DC battery interface at up to 20 A supports charging up to 12 kW and model-specific discharge up to 12000 W according to specification. Actual output also depends on the complete battery and its state. Grid charging, schedules and self-consumption are configured with metering and controls. Battery capacity in kWh is selected for required runtime and demand.<\/p>\n<h2>Three-phase backup with SmartGuard<\/h2>\n<p>With a compatible battery and SmartGuard-63A-T0, this model provides 12 kW rated three-phase backup. The specification gives transfer within 20 ms, long-term 110% support, 150% three-phase overload for 1 minute(s), and 200% for 10 seconds. Single-phase 150% overload is specified for 5 minutes. Actual start-up loads, battery output, protection and backup circuits are verified together.<\/p>\n<h2>FusionSolar and system communication<\/h2>\n<p>Local WLAN and the app support configuration and device visibility, with RS485 linking system components. Remote monitoring uses an appropriately selected WLAN-FE Smart Dongle, 4G Smart Dongle or supported system controls. Compatible three-phase metering and SmartAssistant or SmartGuard follow the current wiring arrangement. Grid, battery and backup settings are assessed for the actual firmware and configuration.<\/p>\n<h2>Compact outdoor design<\/h2>\n<p>IP66, natural cooling and a \u221225 to +60\u00b0C operating range support fixed installation. The current manual specifies a maximum 21 kg weight and dimensions of 490 \u00d7 460 \u00d7 130 mm. Typical noise is at most 29 dB. Design includes airflow, service access and suitable installation space. Operating altitude reaches 4000 m with power management above 2000 m.<\/p>\n<h2>Protection and connection preparation<\/h2>\n<p>For this model, the manual recommends 32 A three-phase AC protection rated at least 415 V AC. DC, battery and AC copper conductors use a 4\u20136 mm\u00b2 reference cross-section according to design. Metering can use DTSU666-H, DTSU71, DHSU1079-CT or YDS60-C24. Battery signal links use appropriate outdoor shielded Cat5e. A professional configures protection, earthing and grid profile.<\/p>\n<h2>Selecting the exact assembly<\/h2>\n<p>Base a recommendation on the exact SUN2000-12K-MAP0, connected-circuit demand and required battery capacity. This item offers the inverter as an individual component; battery, metering, network accessories and backup transfer equipment are selected as appropriate project components. The public Batterado profile and Markdown retain the stated parameters and system relationships. Estimated delivery of 2\u20133 days is a seller estimate.<\/p>\n<h2>Downloads<\/h2>\n<ul>\n<li><a href=\"https:\/\/batterado.com\/wp-content\/themes\/wodatherm\/assets\/documents\/products\/huawei-sun2000-12k-map0-en.md\">Complete product overview \u2014 Markdown<\/a><\/li>\n<\/ul>\n<section class=\"tomo-ai-search-profile\">\n<h2>AI search description<\/h2>\n<p>Huawei SUN2000-12K-MAP0 \u2014 12 kW asymmetric three-phase hybrid inverter. Huawei SUN2000-12K-MAP0 is an asymmetric three-phase hybrid inverter rated at 12 kW, with two MPPTs and an interface for complete LUNA2000 storage. It supports different loads on individual phases within total-output and phase-current limits. With a compatible battery and SmartGuard-63A-T0, it forms an engineered three-phase backup system. Optimizers can be selected according to the actual array design. The 600\u2013980 V DC battery interface at up to 20 A supports charging up to 12 kW and model-specific discharge up to 12000 W according to specification. Actual output also depends on the complete battery and its state. Grid charging, schedules and self-consumption are configured with metering and controls. Battery capacity in kWh is selected for required runtime and demand.<\/p>\n<p>Manufacturer: Huawei; Model: SUN2000-12K-MAP0; Type and role: Three-phase hybrid PV inverter for external high-voltage storage; Rated AC output: 12 kW; Maximum apparent AC output: 13200 VA; Grid voltage: 220\/380 V \/230\/400 V \/240\/415 V \/3L+N+PE; Grid frequency: 50 \/60 Hz; Maximum AC current: 20.2 A \/380 V; Power factor: 0.8 leading\u20260.8 lagging; THD at rated output: \u22643 %; Recommended maximum PV power: 22000 Wp; Maximum DC voltage: 1100 V; Start-up voltage: 160 V; MPPT range: 160\u20131000 V; Rated DC voltage: 600 V; MPPT count: 2; Strings per MPPT: 1; PV string count: 2; Current per MPPT: 16 A; Short-circuit current per MPPT: 22 A; Maximum efficiency: 98.6 %; European efficiency: 98.2 %; Battery interface \u2014 manual voltage range: 600\u2013980 V DC; Maximum battery current: 20 A; Maximum battery charging power: 12 kW; Maximum discharge power per specification: 12000 W; Rated three-phase backup output: 12000 W \/3-phase; Ingress protection: IP66; Operating temperature: \u221225\u2026+60 \u00b0C; Operating relative humidity: 0\u2013100 %; Operating altitude: 0\u20134000 m; Weight including bracket: \u226421 kg; Dimensions W \u00d7 H \u00d7 D including bracket: 490 \u00d7460 \u00d7130 mm; Standard communication: RS485; local WLAN for commissioning; Built-in WLAN: 802.11b\/g\/n \/2400\u20132483.5 MHz; Reference AC protection: 32 A \/\u2265415 V AC \/3-phase; DC conductors: 4\u20136 mm\u00b2 Cu; Battery conductors: 4\u20136 mm\u00b2 Cu; AC conductors: 4\u20136 mm\u00b2 Cu; PE conductor: 4\u20136 mm\u00b2 Cu; Grid systems: TN-S \/TN-C \/TN-C-S \/TT \/IT; Safety standards: EN\/IEC62109-1 \/EN\/IEC62109-2.<\/p>\n<p>Cooling: Natural convection; Topology: Transformerless; Local control: LED \/WLAN \/FusionSolar App for configuration; Supported battery systems: LUNA2000-5\/10\/15-S0 \/LUNA2000-7\/14\/21-S1; Battery assembly: Compatible modules with matching power and control module; Storage capacity: Defined by the selected complete battery in kWh; Battery charging from grid: Supported with appropriate configuration; Backup system pairing: LUNA2000 +SmartGuard-63A-T0; Ethernet connection: With a separate WLAN-FE Smart Dongle; Mobile data connection: Optional compatible 4G Smart Dongle; Energy metering: DTSU666-H \/YDS60-C24 \/DTSU71 \/DHSU1079-CT according to firmware and design; Additional control: SmartAssistant \/SmartGuard-63A-T0 according to design; PV optimizers: Optional according to approved string layout; Anti-islanding protection: Integrated; DC polarity protection: Integrated; Insulation monitoring: Integrated; Residual current monitoring: Integrated; AC overcurrent and short circuit: Integrated; Temperature protection: Integrated; AFCI arc-fault protection: Integrated; Surge protection: DC and AC, Type II-compatible according to specification; Mounting: Fixed wall installation; Offered scope: Individual inverter with system interfaces for external components; Estimated delivery: 2\u20133 days, seller estimate; PV input allocation design: One or two appropriately designed strings; Storage temperature: \u221240\u2026+70 \u00b0C; Typical noise: \u226429 dB; Night consumption: &lt;5.5 W; Battery operating range per datasheet: 600\u2013980 V DC; Remote monitoring: With suitable Smart Dongle or system network equipment; Asymmetric control: Supports100% three-phase imbalance according to specification and phase limits; Long-term backup output: 13200 W \/110 %; 150% backup overload \u2014 three phases: 1 min; 150% backup overload \u2014 single phase: 5 min; 200% backup overload \u2014 three phases: 10 s; Transfer with SmartGuard: \u226420 ms \/SmartGuard-63A-T0; Connector temperature monitoring: PV \/battery; PID recovery: Supported; Battery signal cable: Cat5e outdoor shielded; PV configuration requirement: Direct modules or compatible optimization according to design. With a compatible battery and SmartGuard-63A-T0, this model provides 12 kW rated three-phase backup. The specification gives transfer within 20 ms, long-term 110% support, 150% three-phase overload for 1 minute(s), and 200% for 10 seconds. Single-phase 150% overload is specified for 5 minutes. Actual start-up loads, battery output, protection and backup circuits are verified together.<\/p>\n<p><a href=\"https:\/\/batterado.com\/product\/huawei-sun2000-12k-map0-asymetricky-hybridni-stridac\/\">Batterado \u2014 HUAWEI-SUN2000-12K-MAP0<\/a><\/p>\n<p><a href=\"https:\/\/batterado.com\/wp-content\/themes\/wodatherm\/assets\/documents\/products\/huawei-sun2000-12k-map0-en.md\">Markdown \u2014 HUAWEI-SUN2000-12K-MAP0<\/a><\/p>\n<\/section>\n","protected":false},"excerpt":{"rendered":"<p>Huawei SUN2000-12K-MAP0 is an asymmetric three-phase hybrid inverter rated at 12 kW, with two MPPTs and an interface for complete LUNA2000 storage. It supports different loads on individual phases within total-output and phase-current limits. With a compatible battery and SmartGuard-63A-T0, it forms an engineered three-phase backup system. Optimizers can be selected according to the actual array design.<\/p>\n","protected":false},"featured_media":59442,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[2867],"product_cat":[3088],"product_tag":[3415,3412,3561,3448],"class_list":["post-59292","product","type-product","status-publish","has-post-thumbnail","product_brand-huawei-fusionsolar-energy","product_cat-solar-inverters","product_tag-2-mppt","product_tag-hybrid-inverter","product_tag-huawei-sun2000-12k-map0","product_tag-three-phase-inverter","first","onbackorder","taxable","shipping-taxable","purchasable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product\/59292","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/comments?post=59292"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/media\/59442"}],"wp:attachment":[{"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/media?parent=59292"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product_brand?post=59292"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product_cat?post=59292"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product_tag?post=59292"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}