{"id":59180,"date":"2026-11-01T06:11:07","date_gmt":"2026-11-01T04:11:07","guid":{"rendered":"https:\/\/batterado.com\/?post_type=product&#038;p=59180"},"modified":"2026-11-01T13:51:48","modified_gmt":"2026-11-01T11:51:48","slug":"solis-evercore-261-system","status":"publish","type":"product","link":"https:\/\/batterado.com\/en\/product\/solis-evercore-261-system\/","title":{"rendered":"Solis EverCore 261 \u2014 261.248 kWh storage with 125 kW inverter"},"content":{"rendered":"<h2>Technical specifications<\/h2>\n<div class=\"wt-tech-grid\">\n<table>\n<tbody>\n<tr>\n<th>Manufacturer<\/th>\n<td>Ginlong Energy Storage \/SolisStorage<\/td>\n<\/tr>\n<tr>\n<th>Family<\/th>\n<td>EverCore<\/td>\n<\/tr>\n<tr>\n<th>Variant<\/th>\n<td>261 kWh<\/td>\n<\/tr>\n<tr>\n<th>Device type<\/th>\n<td>Battery storage system with inverter<\/td>\n<\/tr>\n<tr>\n<th>Nominal energy<\/th>\n<td>261.248 kWh<\/td>\n<\/tr>\n<tr>\n<th>Cell chemistry<\/th>\n<td>LiFePO4 \/LFP<\/td>\n<\/tr>\n<tr>\n<th>Cells<\/th>\n<td>EVE MB31<\/td>\n<\/tr>\n<tr>\n<th>Nominal cell voltage<\/th>\n<td>3.2 V<\/td>\n<\/tr>\n<tr>\n<th>Cell capacity<\/th>\n<td>314 Ah<\/td>\n<\/tr>\n<tr>\n<th>Battery pack count<\/th>\n<td>13<\/td>\n<\/tr>\n<tr>\n<th>Pack model<\/th>\n<td>PACK-1P20S-314-01<\/td>\n<\/tr>\n<tr>\n<th>Pack configuration<\/th>\n<td>1P20S<\/td>\n<\/tr>\n<tr>\n<th>Pack energy per manual<\/th>\n<td>20.10 kWh<\/td>\n<\/tr>\n<tr>\n<th>Pack voltage<\/th>\n<td>64 V<\/td>\n<\/tr>\n<tr>\n<th>Pack voltage range<\/th>\n<td>58\u201372 V<\/td>\n<\/tr>\n<tr>\n<th>Pack weight<\/th>\n<td>138 kg<\/td>\n<\/tr>\n<tr>\n<th>Pack dimensions W \u00d7H \u00d7D<\/th>\n<td>435 \u00d7230 \u00d7904 mm<\/td>\n<\/tr>\n<tr>\n<th>Battery configuration<\/th>\n<td>1P260S<\/td>\n<\/tr>\n<tr>\n<th>Total cell count<\/th>\n<td>260<\/td>\n<\/tr>\n<tr>\n<th>Nominal DC voltage<\/th>\n<td>832 V<\/td>\n<\/tr>\n<tr>\n<th>Operating DC voltage<\/th>\n<td>754\u2013936 V<\/td>\n<\/tr>\n<tr>\n<th>Rated DC current<\/th>\n<td>157 A<\/td>\n<\/tr>\n<tr>\n<th>Cycle rate<\/th>\n<td>0.5 P<\/td>\n<\/tr>\n<tr>\n<th>Maximum battery charge power<\/th>\n<td>125 kW<\/td>\n<\/tr>\n<tr>\n<th>Maximum battery discharge power<\/th>\n<td>125 kW<\/td>\n<\/tr>\n<tr>\n<th>Actual power calculation<\/th>\n<td>Voltage \u00d7current, BMS, SOC, temperature and connected inverter<\/td>\n<\/tr>\n<tr>\n<th>Usable energy<\/th>\n<td>According to SOC settings, reserve and operating losses<\/td>\n<\/tr>\n<tr>\n<th>Battery management<\/th>\n<td>BMU \/BCU \/EMU<\/td>\n<\/tr>\n<tr>\n<th>Cell balancing<\/th>\n<td>Passive<\/td>\n<\/tr>\n<tr>\n<th>Communication protocols<\/th>\n<td>CAN \/RS485 \/TCP\/IP<\/td>\n<\/tr>\n<tr>\n<th>Battery-inverter communication<\/th>\n<td>CAN \/BMS1<\/td>\n<\/tr>\n<tr>\n<th>Cabinet controller<\/th>\n<td>EMU<\/td>\n<\/tr>\n<tr>\n<th>Power distribution<\/th>\n<td>PDU<\/td>\n<\/tr>\n<tr>\n<th>Cabinet cooling<\/th>\n<td>Industrial air conditioning<\/td>\n<\/tr>\n<tr>\n<th>Thermal modes<\/th>\n<td>Cooling, heating, dehumidification and air circulation<\/td>\n<\/tr>\n<tr>\n<th>Air-conditioner cooling capacity<\/th>\n<td>5 kW<\/td>\n<\/tr>\n<tr>\n<th>Air-conditioner heating capacity<\/th>\n<td>3 kW<\/td>\n<\/tr>\n<tr>\n<th>Refrigerant<\/th>\n<td>R134a<\/td>\n<\/tr>\n<tr>\n<th>Pack cooling<\/th>\n<td>Air cooling<\/td>\n<\/tr>\n<tr>\n<th>Auxiliary AC supply<\/th>\n<td>220 V AC<\/td>\n<\/tr>\n<tr>\n<th>Auxiliary supply rating<\/th>\n<td>~4 kW<\/td>\n<\/tr>\n<tr>\n<th>Charging ambient temperature<\/th>\n<td>0\u2026+55 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th>Discharging ambient temperature<\/th>\n<td>\u221225\u2026+55 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th>Cabinet storage temperature per manual<\/th>\n<td>\u221220\u2026+45 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th>Operating humidity<\/th>\n<td>\u226495 % non-condensing<\/td>\n<\/tr>\n<tr>\n<th>Cabinet ingress protection<\/th>\n<td>IP55<\/td>\n<\/tr>\n<tr>\n<th>Quoted anti-corrosion configuration<\/th>\n<td>C4H+C5 \/C5<\/td>\n<\/tr>\n<tr>\n<th>Family noise at rated operation<\/th>\n<td>75 dB(A) @1 m<\/td>\n<\/tr>\n<tr>\n<th>Cabinet dimensions W \u00d7H \u00d7D<\/th>\n<td>1400 \u00d72230 \u00d71600 mm<\/td>\n<\/tr>\n<tr>\n<th>Reference battery-cabinet weight<\/th>\n<td>2900 kg<\/td>\n<\/tr>\n<tr>\n<th>Siting<\/th>\n<td>Fixed outdoor location according to site design<\/td>\n<\/tr>\n<tr>\n<th>Foundation<\/th>\n<td>Level non-combustible foundation sized for the actual system<\/td>\n<\/tr>\n<tr>\n<th>Handling<\/th>\n<td>Professional lifting or forklift equipment<\/td>\n<\/tr>\n<tr>\n<th>Protection sensing<\/th>\n<td>Temperature and smoke<\/td>\n<\/tr>\n<tr>\n<th>Pack protection<\/th>\n<td>Aerosol system<\/td>\n<\/tr>\n<tr>\n<th>Pressure relief<\/th>\n<td>Pressure-relief valve<\/td>\n<\/tr>\n<tr>\n<th>Indication<\/th>\n<td>Audible and visual<\/td>\n<\/tr>\n<tr>\n<th>Fire-water connection<\/th>\n<td>DN65<\/td>\n<\/tr>\n<tr>\n<th>Fire-linkage output<\/th>\n<td>XT3:1 \/XT3:2<\/td>\n<\/tr>\n<tr>\n<th>Safety equipment configuration<\/th>\n<td>Aerosol, temperature and smoke detection, pressure valve, visual and audible indication<\/td>\n<\/tr>\n<tr>\n<th>Cell cycle test<\/th>\n<td>8000; 25\u00b12 \u00b0C; 0.5 P; SOH70 %<\/td>\n<\/tr>\n<tr>\n<th>Cycle-value applicability<\/th>\n<td>Cell-manufacturer data under test conditions<\/td>\n<\/tr>\n<tr>\n<th>Estimated delivery<\/th>\n<td>2\u20133 days, seller operating estimate<\/td>\n<\/tr>\n<tr>\n<th>Installation arrangement<\/th>\n<td>Engineered connection by qualified personnel<\/td>\n<\/tr>\n<tr>\n<th>Inverter pairing<\/th>\n<td>S6-EH3P125K10-NV-YD-H included in system<\/td>\n<\/tr>\n<tr>\n<th>Grid charging<\/th>\n<td>Through the supplied hybrid inverter according to settings and design<\/td>\n<\/tr>\n<tr>\n<th>PV connection<\/th>\n<td>To MPPTs of the matching hybrid inverter<\/td>\n<\/tr>\n<tr>\n<th>Battery-bank setting<\/th>\n<td>1<\/td>\n<\/tr>\n<tr>\n<th>DC port connection<\/th>\n<td>Two inverter ports to one bank according to EverCore diagram<\/td>\n<\/tr>\n<tr>\n<th>Battery model in app<\/th>\n<td>SolisStorage<\/td>\n<\/tr>\n<tr>\n<th>DC expansion<\/th>\n<td>Additional matching cabinets through busbars according to design<\/td>\n<\/tr>\n<tr>\n<th>Linked-cabinet control<\/th>\n<td>EMU CAN \/Cat6a STP \/T568B<\/td>\n<\/tr>\n<tr>\n<th>Controller network<\/th>\n<td>WAN1 \/Ethernet \/TCP\/IP<\/td>\n<\/tr>\n<tr>\n<th>Cabinet-count configuration<\/th>\n<td>According to actually connected cabinets<\/td>\n<\/tr>\n<tr>\n<th>Monitoring<\/th>\n<td>SolisCloud and local EMU<\/td>\n<\/tr>\n<tr>\n<th>Commissioning<\/th>\n<td>Installer role, verification of wiring, grid, BMS and SOC<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Rated AC output<\/th>\n<td>125000 W<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Grid connection<\/th>\n<td>3\/N\/PE; 220\/380 V; 230\/400 V<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Grid frequency<\/th>\n<td>50 \/60 Hz<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Power factor<\/th>\n<td>&gt;0.99; 0.8 leading \/lagging<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 THDi<\/th>\n<td>&lt;3 %<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Keys<\/th>\n<td>ESC \/UP \/DOWN \/ENTER<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Status LEDs<\/th>\n<td>POWER \/OPERATION \/ALARM<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 App roles<\/th>\n<td>Installer \/Owner<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Operating modes<\/th>\n<td>Self Use \/Selling First \/Off Grid \/Peak Shaving<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Grid charging<\/th>\n<td>Allow Grid Charging<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Time scheduling<\/th>\n<td>6 charging and 6 discharging windows<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Default maximum charge<\/th>\n<td>100 % SOC<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 SOC setting order<\/th>\n<td>Force Charge &lt;Over-discharge &lt;Recovery<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Smart port \u2014 function selection<\/th>\n<td>Genset input \/AC coupled \/Smart load output<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 PV conductors<\/th>\n<td>4\u20136 mm\u00b2; recommended 4 mm\u00b2<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 PV stripping<\/th>\n<td>7 \u00b10.5 mm<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Ingress protection<\/th>\n<td>IP66<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Operating temperature<\/th>\n<td>\u221225\u2026+60 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Operating humidity<\/th>\n<td>0\u2013100 % RH<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Bluetooth<\/th>\n<td>BDR \/EDR \/BLE; 2.402\u20132.480 GHz; 8 dBm<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 App sections<\/th>\n<td>Home \/Info \/Alarm \/Settings<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Operating information<\/th>\n<td>PV \/Battery \/Grid \/Load \/Inverter; SOC \/SOH; energy history and generator yield<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Diagnostics<\/th>\n<td>Current and historical alarms<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Initial settings<\/th>\n<td>Time, CT\/meter, grid code, operating mode and battery banks<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Over-discharge SOC<\/th>\n<td>5\u201340 %; default 20 %<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Force-charge SOC<\/th>\n<td>From 4% to selected over-discharge SOC<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Discharge recovery<\/th>\n<td>1\u201320 percentage points above over-discharge SOC<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<th>Inverter \u2014 Generator \u2014 start \/stop SOC<\/th>\n<td>1\u201395 % \/35\u2013100 %<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 AC coupling \u2014 start \/stop SOC<\/th>\n<td>1\u201395 % \/35\u2013100 %<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Maximum AC apparent output<\/th>\n<td>125000 VA<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Rated backup output<\/th>\n<td>125000 W<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Backup peak 10 seconds<\/th>\n<td>175.0 kVA \/10 s<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Backup peak 200 ms<\/th>\n<td>200.0 kVA \/200 ms<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Single-unit transfer<\/th>\n<td>&lt;10 ms<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Parallel transfer up to 6 units<\/th>\n<td>&lt;20 ms<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Maximum power per phase<\/th>\n<td>41.66 kW<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Phase imbalance<\/th>\n<td>100 %<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 THDv linear load<\/th>\n<td>&lt;3 %<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 MPPT count<\/th>\n<td>10<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 String count<\/th>\n<td>20<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Strings per MPPT<\/th>\n<td>2<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Input current per MPPT<\/th>\n<td>42 A<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Current per string<\/th>\n<td>21 A<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Short-circuit current per MPPT<\/th>\n<td>60 A<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Recommended PV array rating<\/th>\n<td>250 kWp<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Maximum usable PV power<\/th>\n<td>250 kW<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Maximum DC voltage<\/th>\n<td>1000 V<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Rated DC voltage<\/th>\n<td>600 V<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Start-up voltage<\/th>\n<td>180 V<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 MPPT range<\/th>\n<td>150\u2013950 V<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 DC switches<\/th>\n<td>2; PV1\u2013PV10 and PV11\u2013PV20<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Battery type<\/th>\n<td>Compatible HV Li-ion system with BMS<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Battery voltage<\/th>\n<td>300\u2013950 V<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Battery ports \/BMS count<\/th>\n<td>2 \/2<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Maximum battery current per port<\/th>\n<td>100 A<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Combined battery current<\/th>\n<td>Up to 200 A according to wiring and BMS<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Battery communication<\/th>\n<td>CAN<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 BMS CAN RJ45<\/th>\n<td>4 CAN-H \/5 CAN-L<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 One battery \u2014 one port<\/th>\n<td>BAT1 +BMS1<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 One battery \u2014 two ports<\/th>\n<td>BAT1 +BAT2, BMS1 according to diagram<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Two independent batteries<\/th>\n<td>Each with its own BAT and BMS port<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Bank settings<\/th>\n<td>Count 1\u20132, model, connection method, current and SOC<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Battery operating point 300 V<\/th>\n<td>90 A \/27 kW<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Battery operating point 400 V<\/th>\n<td>100 A \/40 kW<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Battery operating point 500 V<\/th>\n<td>100 A \/50 kW<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Battery operating point 600 V<\/th>\n<td>100 A \/60 kW<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Family battery-port limit<\/th>\n<td>65 kW<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Determining actual battery power<\/th>\n<td>U\u00d7I, BMS, port and specific model limits<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Rated AC current at 380\/400 V<\/th>\n<td>189.9 \/180.4 A<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Maximum grid input current<\/th>\n<td>250 A<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Grid voltage range<\/th>\n<td>304\u2013460 V<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Generator \u2014 maximum input power<\/th>\n<td>125 kW<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Generator \u2014 current at 380\/400 V<\/th>\n<td>189.9 \/180.4 A<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Maximum efficiency<\/th>\n<td>97.5 %<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 European efficiency<\/th>\n<td>97.2 %<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 PV \u2192battery efficiency<\/th>\n<td>98.2 %<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 AC \u2192battery efficiency<\/th>\n<td>97.0 %<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Battery \u2192AC efficiency<\/th>\n<td>97.0 %<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Self-consumption<\/th>\n<td>&lt;45 W<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 User interface<\/th>\n<td>7.0\u2033 LCD \/Bluetooth \/SolisCloud<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Battery reserve<\/th>\n<td>Batt saving; default SOC 80%<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Demand control<\/th>\n<td>Grid Peak Shaving according to mode, SOC and system capability<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Parallel-system export calibration<\/th>\n<td>0.5% total capacity according to manual<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Standard meter<\/th>\n<td>Eastron SDM630MCT V2<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Standard CTs<\/th>\n<td>3 \u00d7Acrel AKH-0.66-K-80\u00d740-600A; 600 A \/5 A<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 CT ratio<\/th>\n<td>120<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 CT cable<\/th>\n<td>5 m \/0.8 mm\u00b2<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 CT orientation<\/th>\n<td>P1 towards inverter, P2 towards grid<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 CT terminals L1<\/th>\n<td>1 black (+), 2 purple (\u2212)<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 CT terminals L2<\/th>\n<td>3 orange (+), 4 blue (\u2212)<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 CT terminals L3<\/th>\n<td>5 yellow (+), 6 green (\u2212)<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 METER terminals<\/th>\n<td>21 A \/22 B<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 RS485 for Solis PV inverter<\/th>\n<td>19 A \/20 B<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 EMS protocol \/RJ45<\/th>\n<td>Modbus RTU; 5 A \/4 B<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 ETH interface<\/th>\n<td>TCP\/IP; 1 TX+ \/2 TX\u2212 \/3 RX+ \/6 RX\u2212<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Communication glands<\/th>\n<td>COM1\/COM2: 7 holes, 6 mm<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 GEN DO1<\/th>\n<td>11\/12; generator start at Grid or Smart<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 GEN DO2<\/th>\n<td>13\/14; generator start at Smart<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 GEN DI1<\/th>\n<td>5\/6; ATS voltage-free contact<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 GEN DI2<\/th>\n<td>7\/8; external 5\/12 VDC status signal<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 RSD \/EPO<\/th>\n<td>External shutdown through designated terminals according to diagram<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 AC C<\/th>\n<td>External AC-coupled-source relay control<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 SG-DO<\/th>\n<td>Heat-pump interface<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 AC coupling \u2014 three-phase PV at Smart<\/th>\n<td>PV inverter rated output up to hybrid rating<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Dual AC-coupling metering<\/th>\n<td>Meter 001 grid, 002 PV source<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Parallel unit count<\/th>\n<td>Up to 6 basic layout; 7\u201310 with external STS according to project<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Parallel models<\/th>\n<td>Matching model and current ARM\/DSP firmware<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Parallel communication<\/th>\n<td>P-A \/P-B; shielded CAT5<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Total parallel connection length<\/th>\n<td>&lt;60 m<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 System addresses<\/th>\n<td>Primary 1; Secondary 2, 3\u2026<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 DIP termination<\/th>\n<td>Endpoint units ON, intermediate OFF<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Parallel-system batteries<\/th>\n<td>Assigned to individual inverters with separate battery settings<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 AC length difference above 2 units<\/th>\n<td>\u226410 %<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Altitude<\/th>\n<td>3000 m<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Cooling<\/th>\n<td>Intelligent redundant fan cooling<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Typical noise<\/th>\n<td>&lt;70 dB(A)<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Surge protection<\/th>\n<td>DC Type II \/AC Type II<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Battery conductors<\/th>\n<td>Cu 25\u201335 mm\u00b2; max.35 mm\u00b2<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Battery terminals<\/th>\n<td>M6; 4.5\u20135.0 Nm<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Backup conductors \/terminals<\/th>\n<td>Cu 70 mm\u00b2; max.95 mm\u00b2; M8; 10\u201312 Nm<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Smart conductors \/terminals<\/th>\n<td>Cu 70 mm\u00b2; max.120 mm\u00b2; M12; 20\u201330 Nm<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Grid conductors \/terminals<\/th>\n<td>Cu 95 mm\u00b2; max.150 mm\u00b2; M12; 20\u201330 Nm<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 PE conductors \/terminals<\/th>\n<td>Cu 50\u201370 mm\u00b2; M10; 10\u201312 Nm<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Battery \/AC stripping<\/th>\n<td>OT crimp-area length +2\u20133 mm<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Reference Grid protection<\/th>\n<td>\u2265315 A \/\u2265400 VAC according to design<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Reference Backup \/Smart protection<\/th>\n<td>&gt;225 A \/\u2265400 VAC according to design<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Maximum Backup AC passthrough<\/th>\n<td>189.9 \/180.4 A<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 125 kW model combined battery power example<\/th>\n<td>130 kW; 2 \u00d765 kW<\/td>\n<\/tr>\n<tr>\n<th>System dimensions W \u00d7H \u00d7D<\/th>\n<td>1850 \u00d72230 \u00d71600 mm<\/td>\n<\/tr>\n<tr>\n<th>Power and energy pairing<\/th>\n<td>125 kW \/261.248 kWh<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2>Energy for business operations<\/h2>\n<p>EverCore 261 offers 261.248 kWh in LFP battery modules for commercial PV, peak-demand management and scheduled use of stored electricity. This system combines the outdoor battery cabinet with the Solis S6-EH3P125K10-NV-YD-H hybrid inverter rated at 125 kW.<\/p>\n<h2>What the offer includes<\/h2>\n<p>The 261 kWh variant contains 13 battery packs with 261.248 kWh total nominal energy, battery management, EMU, PDU and an air-conditioning system. This offer also includes the specific S6-EH3P125K10-NV-YD-H inverter. Cabinet and inverter form a system for professional interconnection at the prepared site.<\/p>\n<h2>Capacity and power serve different purposes<\/h2>\n<p>The 261.248 kWh capacity describes stored energy. Power determines which appliances and processes can operate simultaneously. The manual specifies up to 125 kW charging and discharging for the battery section; actual AC delivery also depends on the connected inverter, current voltage, BMS limits, SOC and temperature. An initial runtime estimate uses average demand in kW multiplied by operating hours, with allowance for losses and the desired backup reserve.<\/p>\n<h2>Modular LFP architecture<\/h2>\n<p>EVE MB31 cells combine 314 Ah capacity with LiFePO4 chemistry. The 13-pack assembly has 832 V nominal voltage and a 754\u2013936 V operating range. Each pack monitors its cells and communicates with higher-level management. The 8000-cycle figure refers to cell testing at 25\u00b12\u00b0C, 0.5 P and an end SOH of 70%, providing a technology comparison under the same test conditions.<\/p>\n<h2>Climate control for the battery<\/h2>\n<p>Industrial air conditioning provides cooling, heating, dehumidification and air circulation. The exact air-conditioner table specifies 5 kW cooling and 3 kW heating. The manual distinguishes charging ambient temperature of 0 to +55\u00b0C and discharging ambient temperature of \u221225 to +55\u00b0C. Thermal management and BMS coordinate conditions inside the system. The auxiliary supply rating is a connection-design figure; actual air-conditioner consumption varies with thermal load and operating mode.<\/p>\n<h2>PV, grid and backup<\/h2>\n<p>Paired with the matching S6-EH3P125K10-NV-YD-H hybrid inverter, the cabinet supports direct PV charging through MPPTs, configured grid charging and supply to designated backup circuits. Self-use, selling-first and off-grid modes are selected according to site design. PV serves loads first; scheduling, SOC reserve and peak management align storage with business operation. Each proposed system is assessed for simultaneous demand, starting loads, phase distribution and required backup duration.<\/p>\n<h2>Protection layers and PRO configuration<\/h2>\n<p>Equipment combines battery supervision, temperature and smoke sensors, aerosol protection, a pressure valve and audible\/visual indication. The DN65 connection and fire-linkage output support integration into an engineered fire-protection design. This standard configuration contains the specifically described protective equipment; a separate PRO catalogue variant provides the additional detection and pressure-relief components.<\/p>\n<h2>EMU and SolisCloud<\/h2>\n<p>EMU brings together cabinet operating information and control links. SolisCloud provides visibility and configuration for the connected hybrid inverter; initial commissioning uses the installer role. Settings specify one battery bank, the SolisStorage model, the two-DC-port connection method and the actual cabinet count. Meter, CT-ratio and measurement-direction checks form part of commissioning. Auxiliary supply and Only PV Power Load \/ Grid To Load (Bypass) functions are configured for the selected backup arrangement.<\/p>\n<h2>Expansion designed as a system<\/h2>\n<p>Documentation covers DC expansion with matching cabinets on one inverter and AC-parallel systems using matching models. In an AC-parallel arrangement, each inverter has its assigned battery. EMUs use their own communication chain and controllers use Ethernet; inverter-parallel communication is separate. Unit count, backup transfer, any STS, conductor sizes, protection and firmware are engineered for the specific models and required power.<\/p>\n<h2>How to select the right system<\/h2>\n<p>Selection starts with average and simultaneous demand, operating duration and the required reserve. Nominal 261.248 kWh is the starting energy figure; usable SOC, efficiency and auxiliary systems affect delivered energy. Inverter selection follows kW, phases and starting requirements, while battery selection also checks voltage, current and BMS. EverCore uses a fixed engineered site with suitable load-bearing capacity, service access and electrical preparation. This connects energy requirements to a specific configuration instead of a single search keyword.<\/p>\n<h2>Delivery and connection planning<\/h2>\n<p>Delivery is planned together with transport and professional cabinet unloading. Dimensions and reference weights in the specifications support site preparation; the installation design defines foundation, clearances, earthing, protection and cable routes. During assembly, the inverter attaches to the prepared cabinet structure. This offer is defined by cabinet versus cabinet-with-inverter selection and standard versus PRO equipment. The estimated 2\u20133-day lead time is the seller\u2019s operating estimate.<\/p>\n<h2>Downloads<\/h2>\n<ul>\n<li><a href=\"https:\/\/batterado.com\/wp-content\/themes\/wodatherm\/assets\/documents\/products\/solis-evercore-261-system-en.md\">Complete product overview \u2014 Markdown<\/a><\/li>\n<\/ul>\n<section class=\"tomo-ai-search-profile\">\n<h2>AI search description<\/h2>\n<p>Solis EverCore 261 \u2014 261.248 kWh storage with 125 kW inverter. The 261 kWh variant contains 13 battery packs with 261.248 kWh total nominal energy, battery management, EMU, PDU and an air-conditioning system. This offer also includes the specific S6-EH3P125K10-NV-YD-H inverter. Cabinet and inverter form a system for professional interconnection at the prepared site. Paired with the matching S6-EH3P125K10-NV-YD-H hybrid inverter, the cabinet supports direct PV charging through MPPTs, configured grid charging and supply to designated backup circuits. Self-use, selling-first and off-grid modes are selected according to site design. PV serves loads first; scheduling, SOC reserve and peak management align storage with business operation. Each proposed system is assessed for simultaneous demand, starting loads, phase distribution and required backup duration.<\/p>\n<p>Manufacturer: Ginlong Energy Storage \/SolisStorage; Family: EverCore; Variant: 261 kWh; Device type: Battery storage system with inverter; Nominal energy: 261.248 kWh; Cell chemistry: LiFePO4 \/LFP; Cells: EVE MB31; Nominal cell voltage: 3.2 V; Cell capacity: 314 Ah; Battery pack count: 13; Pack model: PACK-1P20S-314-01; Pack configuration: 1P20S; Pack energy per manual: 20.10 kWh; Pack voltage: 64 V; Pack voltage range: 58\u201372 V; Pack weight: 138 kg; Pack dimensions W \u00d7H \u00d7D: 435 \u00d7230 \u00d7904 mm; Battery configuration: 1P260S; Total cell count: 260; Nominal DC voltage: 832 V; Operating DC voltage: 754\u2013936 V; Rated DC current: 157 A; Cycle rate: 0.5 P; Maximum battery charge power: 125 kW; Maximum battery discharge power: 125 kW; Actual power calculation: Voltage \u00d7current, BMS, SOC, temperature and connected inverter; Usable energy: According to SOC settings, reserve and operating losses; Battery management: BMU \/BCU \/EMU; Cell balancing: Passive; Communication protocols: CAN \/RS485 \/TCP\/IP; Battery-inverter communication: CAN \/BMS1; Cabinet controller: EMU; Power distribution: PDU; Cabinet cooling: Industrial air conditioning; Thermal modes: Cooling, heating, dehumidification and air circulation; Air-conditioner cooling capacity: 5 kW; Air-conditioner heating capacity: 3 kW; Refrigerant: R134a; Pack cooling: Air cooling; Auxiliary AC supply: 220 V AC; Auxiliary supply rating: ~4 kW; Charging ambient temperature: 0\u2026+55 \u00b0C; Discharging ambient temperature: \u221225\u2026+55 \u00b0C; Cabinet storage temperature per manual: \u221220\u2026+45 \u00b0C; Operating humidity: \u226495 % non-condensing; Cabinet ingress protection: IP55; Quoted anti-corrosion configuration: C4H+C5 \/C5; Family noise at rated operation: 75 dB(A) @1 m; Cabinet dimensions W \u00d7H \u00d7D: 1400 \u00d72230 \u00d71600 mm; Reference battery-cabinet weight: 2900 kg; Siting: Fixed outdoor location according to site design; Foundation: Level non-combustible foundation sized for the actual system; Handling: Professional lifting or forklift equipment; Protection sensing: Temperature and smoke; Pack protection: Aerosol system; Pressure relief: Pressure-relief valve; Indication: Audible and visual; Fire-water connection: DN65; Fire-linkage output: XT3:1 \/XT3:2; Safety equipment configuration: Aerosol, temperature and smoke detection, pressure valve, visual and audible indication; Cell cycle test: 8000; 25\u00b12 \u00b0C; 0.5 P; SOH70 %; Cycle-value applicability: Cell-manufacturer data under test conditions; Estimated delivery: 2\u20133 days, seller operating estimate; Installation arrangement: Engineered connection by qualified personnel; Inverter pairing: S6-EH3P125K10-NV-YD-H included in system.<\/p>\n<p>Grid charging: Through the supplied hybrid inverter according to settings and design; PV connection: To MPPTs of the matching hybrid inverter; Battery-bank setting: 1; DC port connection: Two inverter ports to one bank according to EverCore diagram; Battery model in app: SolisStorage; DC expansion: Additional matching cabinets through busbars according to design; Linked-cabinet control: EMU CAN \/Cat6a STP \/T568B; Controller network: WAN1 \/Ethernet \/TCP\/IP; Cabinet-count configuration: According to actually connected cabinets; Monitoring: SolisCloud and local EMU; Commissioning: Installer role, verification of wiring, grid, BMS and SOC; Inverter \u2014 Rated AC output: 125000 W; Inverter \u2014 Grid connection: 3\/N\/PE; 220\/380 V; 230\/400 V; Inverter \u2014 Grid frequency: 50 \/60 Hz; Inverter \u2014 Power factor: &gt;0.99; 0.8 leading \/lagging; Inverter \u2014 THDi: &lt;3 %; Inverter \u2014 Keys: ESC \/UP \/DOWN \/ENTER; Inverter \u2014 Status LEDs: POWER \/OPERATION \/ALARM; Inverter \u2014 App roles: Installer \/Owner; Inverter \u2014 Operating modes: Self Use \/Selling First \/Off Grid \/Peak Shaving; Inverter \u2014 Grid charging: Allow Grid Charging; Inverter \u2014 Time scheduling: 6 charging and 6 discharging windows; Inverter \u2014 Default maximum charge: 100 % SOC; Inverter \u2014 SOC setting order: Force Charge &lt;Over-discharge &lt;Recovery; Inverter \u2014 Smart port \u2014 function selection: Genset input \/AC coupled \/Smart load output; Inverter \u2014 PV conductors: 4\u20136 mm\u00b2; recommended 4 mm\u00b2; Inverter \u2014 PV stripping: 7 \u00b10.5 mm; Inverter \u2014 Ingress protection: IP66; Inverter \u2014 Operating temperature: \u221225\u2026+60 \u00b0C; Inverter \u2014 Operating humidity: 0\u2013100 % RH; Inverter \u2014 Bluetooth: BDR \/EDR \/BLE; 2.402\u20132.480 GHz; 8 dBm; Inverter \u2014 App sections: Home \/Info \/Alarm \/Settings; Inverter \u2014 Operating information: PV \/Battery \/Grid \/Load \/Inverter; SOC \/SOH; energy history and generator yield; Inverter \u2014 Diagnostics: Current and historical alarms; Inverter \u2014 Initial settings: Time, CT\/meter, grid code, operating mode and battery banks; Inverter \u2014 Over-discharge SOC: 5\u201340 %; default 20 %; Inverter \u2014 Force-charge SOC: From 4% to selected over-discharge SOC; Inverter \u2014 Discharge recovery: 1\u201320 percentage points above over-discharge SOC; Inverter \u2014 Generator \u2014 start \/stop SOC: 1\u201395 % \/35\u2013100 %; Inverter \u2014 AC coupling \u2014 start \/stop SOC: 1\u201395 % \/35\u2013100 %; Inverter \u2014 Maximum AC apparent output: 125000 VA; Inverter \u2014 Rated backup output: 125000 W; Inverter \u2014 Backup peak 10 seconds: 175.0 kVA \/10 s; Inverter \u2014 Backup peak 200 ms: 200.0 kVA \/200 ms; Inverter \u2014 Single-unit transfer: &lt;10 ms; Inverter \u2014 Parallel transfer up to 6 units: &lt;20 ms; Inverter \u2014 Maximum power per phase: 41.66 kW; Inverter \u2014 Phase imbalance: 100 %; Inverter \u2014 THDv linear load: &lt;3 %; Inverter \u2014 MPPT count: 10; Inverter \u2014 String count: 20; Inverter \u2014 Strings per MPPT: 2; Inverter \u2014 Input current per MPPT: 42 A; Inverter \u2014 Current per string: 21 A; Inverter \u2014 Short-circuit current per MPPT: 60 A; Inverter \u2014 Recommended PV array rating: 250 kWp; Inverter \u2014 Maximum usable PV power: 250 kW; Inverter \u2014 Maximum DC voltage: 1000 V; Inverter \u2014 Rated DC voltage: 600 V; Inverter \u2014 Start-up voltage: 180 V; Inverter \u2014 MPPT range: 150\u2013950 V; Inverter \u2014 DC switches: 2; PV1\u2013PV10 and PV11\u2013PV20; Inverter \u2014 Battery type: Compatible HV Li-ion system with BMS; Inverter \u2014 Battery voltage: 300\u2013950 V; Inverter \u2014 Battery ports \/BMS count: 2 \/2; Inverter \u2014 Maximum battery current per port: 100 A; Inverter \u2014 Combined battery current: Up to 200 A according to wiring and BMS; Inverter \u2014 Battery communication: CAN; Inverter \u2014 BMS CAN RJ45: 4 CAN-H \/5 CAN-L; Inverter \u2014 One battery \u2014 one port: BAT1 +BMS1; Inverter \u2014 One battery \u2014 two ports: BAT1 +BAT2, BMS1 according to diagram; Inverter \u2014 Two independent batteries: Each with its own BAT and BMS port; Inverter \u2014 Bank settings: Count 1\u20132, model, connection method, current and SOC; Inverter \u2014 Battery operating point 300 V: 90 A \/27 kW; Inverter \u2014 Battery operating point 400 V: 100 A \/40 kW; Inverter \u2014 Battery operating point 500 V: 100 A \/50 kW; Inverter \u2014 Battery operating point 600 V: 100 A \/60 kW; Inverter \u2014 Family battery-port limit: 65 kW; Inverter \u2014 Determining actual battery power: U\u00d7I, BMS, port and specific model limits; Inverter \u2014 Rated AC current at 380\/400 V: 189.9 \/180.4 A; Inverter \u2014 Maximum grid input current: 250 A; Inverter \u2014 Grid voltage range: 304\u2013460 V; Inverter \u2014 Generator \u2014 maximum input power: 125 kW; Inverter \u2014 Generator \u2014 current at 380\/400 V: 189.9 \/180.4 A; Inverter \u2014 Maximum efficiency: 97.5 %; Inverter \u2014 European efficiency: 97.2 %; Inverter \u2014 PV \u2192battery efficiency: 98.2 %; Inverter \u2014 AC \u2192battery efficiency: 97.0 %; Inverter \u2014 Battery \u2192AC efficiency: 97.0 %; Inverter \u2014 Self-consumption: &lt;45 W; Inverter \u2014 User interface: 7.0\u2033 LCD \/Bluetooth \/SolisCloud; Inverter \u2014 Battery reserve: Batt saving; default SOC 80%; Inverter \u2014 Demand control: Grid Peak Shaving according to mode, SOC and system capability; Inverter \u2014 Parallel-system export calibration: 0.5% total capacity according to manual; Inverter \u2014 Standard meter: Eastron SDM630MCT V2; Inverter \u2014 Standard CTs: 3 \u00d7Acrel AKH-0.66-K-80\u00d740-600A; 600 A \/5 A; Inverter \u2014 CT ratio: 120; Inverter \u2014 CT cable: 5 m \/0.8 mm\u00b2; Inverter \u2014 CT orientation: P1 towards inverter, P2 towards grid; Inverter \u2014 CT terminals L1: 1 black (+), 2 purple (\u2212); Inverter \u2014 CT terminals L2: 3 orange (+), 4 blue (\u2212); Inverter \u2014 CT terminals L3: 5 yellow (+), 6 green (\u2212); Inverter \u2014 METER terminals: 21 A \/22 B; Inverter \u2014 RS485 for Solis PV inverter: 19 A \/20 B; Inverter \u2014 EMS protocol \/RJ45: Modbus RTU; 5 A \/4 B; Inverter \u2014 ETH interface: TCP\/IP; 1 TX+ \/2 TX\u2212 \/3 RX+ \/6 RX\u2212; Inverter \u2014 Communication glands: COM1\/COM2: 7 holes, 6 mm; Inverter \u2014 GEN DO1: 11\/12; generator start at Grid or Smart; Inverter \u2014 GEN DO2: 13\/14; generator start at Smart; Inverter \u2014 GEN DI1: 5\/6; ATS voltage-free contact; Inverter \u2014 GEN DI2: 7\/8; external 5\/12 VDC status signal; Inverter \u2014 RSD \/EPO: External shutdown through designated terminals according to diagram; Inverter \u2014 AC C: External AC-coupled-source relay control; Inverter \u2014 SG-DO: Heat-pump interface; Inverter \u2014 AC coupling \u2014 three-phase PV at Smart: PV inverter rated output up to hybrid rating; Inverter \u2014 Dual AC-coupling metering: Meter 001 grid, 002 PV source; Inverter \u2014 Parallel unit count: Up to 6 basic layout; 7\u201310 with external STS according to project; Inverter \u2014 Parallel models: Matching model and current ARM\/DSP firmware; Inverter \u2014 Parallel communication: P-A \/P-B; shielded CAT5; Inverter \u2014 Total parallel connection length: &lt;60 m; Inverter \u2014 System addresses: Primary 1; Secondary 2, 3\u2026; Inverter \u2014 DIP termination: Endpoint units ON, intermediate OFF; Inverter \u2014 Parallel-system batteries: Assigned to individual inverters with separate battery settings; Inverter \u2014 AC length difference above 2 units: \u226410 %; Inverter \u2014 Altitude: 3000 m; Inverter \u2014 Cooling: Intelligent redundant fan cooling; Inverter \u2014 Typical noise: &lt;70 dB(A); Inverter \u2014 Surge protection: DC Type II \/AC Type II; Inverter \u2014 Battery conductors: Cu 25\u201335 mm\u00b2; max.35 mm\u00b2; Inverter \u2014 Battery terminals: M6; 4.5\u20135.0 Nm; Inverter \u2014 Backup conductors \/terminals: Cu 70 mm\u00b2; max.95 mm\u00b2; M8; 10\u201312 Nm; Inverter \u2014 Smart conductors \/terminals: Cu 70 mm\u00b2; max.120 mm\u00b2; M12; 20\u201330 Nm; Inverter \u2014 Grid conductors \/terminals: Cu 95 mm\u00b2; max.150 mm\u00b2; M12; 20\u201330 Nm; Inverter \u2014 PE conductors \/terminals: Cu 50\u201370 mm\u00b2; M10; 10\u201312 Nm; Inverter \u2014 Battery \/AC stripping: OT crimp-area length +2\u20133 mm; Inverter \u2014 Reference Grid protection: \u2265315 A \/\u2265400 VAC according to design; Inverter \u2014 Reference Backup \/Smart protection: &gt;225 A \/\u2265400 VAC according to design; Inverter \u2014 Maximum Backup AC passthrough: 189.9 \/180.4 A; Inverter \u2014 125 kW model combined battery power example: 130 kW; 2 \u00d765 kW; System dimensions W \u00d7H \u00d7D: 1850 \u00d72230 \u00d71600 mm; Power and energy pairing: 125 kW \/261.248 kWh. Selection starts with average and simultaneous demand, operating duration and the required reserve. Nominal 261.248 kWh is the starting energy figure; usable SOC, efficiency and auxiliary systems affect delivered energy. Inverter selection follows kW, phases and starting requirements, while battery selection also checks voltage, current and BMS. EverCore uses a fixed engineered site with suitable load-bearing capacity, service access and electrical preparation. This connects energy requirements to a specific configuration instead of a single search keyword.<\/p>\n<p><a href=\"https:\/\/batterado.com\/product\/solis-evercore-261-system\/\">Batterado \u2014 SOLIS-EVERCORE-261-SYSTEM<\/a><\/p>\n<p><a href=\"https:\/\/batterado.com\/wp-content\/themes\/wodatherm\/assets\/documents\/products\/solis-evercore-261-system-en.md\">Markdown \u2014 SOLIS-EVERCORE-261-SYSTEM<\/a><\/p>\n<\/section>\n","protected":false},"excerpt":{"rendered":"<p>EverCore 261 offers 261.248 kWh in LFP battery modules for commercial PV, peak-demand management and scheduled use of stored electricity. This system combines the outdoor battery cabinet with the Solis S6-EH3P125K10-NV-YD-H hybrid inverter rated at 125 kW.<\/p>\n","protected":false},"featured_media":59452,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[2881],"product_cat":[3214,2760],"product_tag":[2925,3530,2861,3519],"class_list":["post-59180","product","type-product","status-publish","has-post-thumbnail","product_brand-solis-storage-energy","product_cat-battery-inverter-systems","product_cat-outdoor-battery-storage","product_tag-commercial-energy-storage","product_tag-solis-evercore-261-system","product_tag-lifepo4","product_tag-solis-evercore","first","onbackorder","taxable","shipping-taxable","purchasable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product\/59180","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/comments?post=59180"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/media\/59452"}],"wp:attachment":[{"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/media?parent=59180"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product_brand?post=59180"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product_cat?post=59180"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product_tag?post=59180"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}