{"id":59164,"date":"2026-11-01T06:10:16","date_gmt":"2026-11-01T04:10:16","guid":{"rendered":"https:\/\/batterado.com\/?post_type=product&#038;p=59164"},"modified":"2026-11-01T13:51:47","modified_gmt":"2026-11-01T11:51:47","slug":"solis-evercore-100-system","status":"publish","type":"product","link":"https:\/\/batterado.com\/en\/product\/solis-evercore-100-system\/","title":{"rendered":"Solis EverCore 100 \u2014 100.48 kWh storage with 50 kW inverter"},"content":{"rendered":"<h2>Technical specifications<\/h2>\n<div class=\"wt-tech-grid\">\n<table>\n<tbody>\n<tr>\n<th>Manufacturer<\/th>\n<td>Ginlong Energy Storage \/SolisStorage<\/td>\n<\/tr>\n<tr>\n<th>Family<\/th>\n<td>EverCore<\/td>\n<\/tr>\n<tr>\n<th>Variant<\/th>\n<td>100 kWh<\/td>\n<\/tr>\n<tr>\n<th>Device type<\/th>\n<td>Battery storage system with inverter<\/td>\n<\/tr>\n<tr>\n<th>Nominal energy<\/th>\n<td>100.48 kWh<\/td>\n<\/tr>\n<tr>\n<th>Cell chemistry<\/th>\n<td>LiFePO4 \/LFP<\/td>\n<\/tr>\n<tr>\n<th>Cells<\/th>\n<td>EVE MB31<\/td>\n<\/tr>\n<tr>\n<th>Nominal cell voltage<\/th>\n<td>3.2 V<\/td>\n<\/tr>\n<tr>\n<th>Cell capacity<\/th>\n<td>314 Ah<\/td>\n<\/tr>\n<tr>\n<th>Battery pack count<\/th>\n<td>5<\/td>\n<\/tr>\n<tr>\n<th>Pack model<\/th>\n<td>PACK-1P20S-314-01<\/td>\n<\/tr>\n<tr>\n<th>Pack configuration<\/th>\n<td>1P20S<\/td>\n<\/tr>\n<tr>\n<th>Pack energy per manual<\/th>\n<td>20.10 kWh<\/td>\n<\/tr>\n<tr>\n<th>Pack voltage<\/th>\n<td>64 V<\/td>\n<\/tr>\n<tr>\n<th>Pack voltage range<\/th>\n<td>58\u201372 V<\/td>\n<\/tr>\n<tr>\n<th>Pack weight<\/th>\n<td>138 kg<\/td>\n<\/tr>\n<tr>\n<th>Pack dimensions W \u00d7H \u00d7D<\/th>\n<td>435 \u00d7230 \u00d7904 mm<\/td>\n<\/tr>\n<tr>\n<th>Battery configuration<\/th>\n<td>1P100S<\/td>\n<\/tr>\n<tr>\n<th>Total cell count<\/th>\n<td>100<\/td>\n<\/tr>\n<tr>\n<th>Nominal DC voltage<\/th>\n<td>320 V<\/td>\n<\/tr>\n<tr>\n<th>Operating DC voltage<\/th>\n<td>290\u2013360 V<\/td>\n<\/tr>\n<tr>\n<th>Rated DC current<\/th>\n<td>157 A<\/td>\n<\/tr>\n<tr>\n<th>Cycle rate<\/th>\n<td>0.5 P<\/td>\n<\/tr>\n<tr>\n<th>Maximum battery charge power<\/th>\n<td>50 kW<\/td>\n<\/tr>\n<tr>\n<th>Maximum battery discharge power<\/th>\n<td>50 kW<\/td>\n<\/tr>\n<tr>\n<th>Actual power calculation<\/th>\n<td>Voltage \u00d7current, BMS, SOC, temperature and connected inverter<\/td>\n<\/tr>\n<tr>\n<th>Usable energy<\/th>\n<td>According to SOC settings, reserve and operating losses<\/td>\n<\/tr>\n<tr>\n<th>Battery management<\/th>\n<td>BMU \/BCU \/EMU<\/td>\n<\/tr>\n<tr>\n<th>Cell balancing<\/th>\n<td>Passive<\/td>\n<\/tr>\n<tr>\n<th>Communication protocols<\/th>\n<td>CAN \/RS485 \/TCP\/IP<\/td>\n<\/tr>\n<tr>\n<th>Battery-inverter communication<\/th>\n<td>CAN \/BMS1<\/td>\n<\/tr>\n<tr>\n<th>Cabinet controller<\/th>\n<td>EMU<\/td>\n<\/tr>\n<tr>\n<th>Power distribution<\/th>\n<td>PDU<\/td>\n<\/tr>\n<tr>\n<th>Cabinet cooling<\/th>\n<td>Industrial air conditioning<\/td>\n<\/tr>\n<tr>\n<th>Thermal modes<\/th>\n<td>Cooling, heating, dehumidification and air circulation<\/td>\n<\/tr>\n<tr>\n<th>Air-conditioner cooling capacity<\/th>\n<td>3.2 kW<\/td>\n<\/tr>\n<tr>\n<th>Air-conditioner heating capacity<\/th>\n<td>1 kW<\/td>\n<\/tr>\n<tr>\n<th>Refrigerant<\/th>\n<td>R134a<\/td>\n<\/tr>\n<tr>\n<th>Pack cooling<\/th>\n<td>Air cooling<\/td>\n<\/tr>\n<tr>\n<th>Auxiliary AC supply<\/th>\n<td>220 V AC<\/td>\n<\/tr>\n<tr>\n<th>Auxiliary supply rating<\/th>\n<td>2.3 kW<\/td>\n<\/tr>\n<tr>\n<th>Charging ambient temperature<\/th>\n<td>0\u2026+55 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th>Discharging ambient temperature<\/th>\n<td>\u221225\u2026+55 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th>Cabinet storage temperature per manual<\/th>\n<td>0\u2026+40 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th>Operating humidity<\/th>\n<td>\u226495 % non-condensing<\/td>\n<\/tr>\n<tr>\n<th>Cabinet ingress protection<\/th>\n<td>IP55<\/td>\n<\/tr>\n<tr>\n<th>Quoted anti-corrosion configuration<\/th>\n<td>C4H+C5 \/C5<\/td>\n<\/tr>\n<tr>\n<th>Family noise at rated operation<\/th>\n<td>70 dB(A) @1 m<\/td>\n<\/tr>\n<tr>\n<th>Cabinet dimensions W \u00d7H \u00d7D<\/th>\n<td>950 \u00d72030 \u00d71540 mm<\/td>\n<\/tr>\n<tr>\n<th>Reference battery-cabinet weight<\/th>\n<td>1500 kg<\/td>\n<\/tr>\n<tr>\n<th>Siting<\/th>\n<td>Fixed outdoor location according to site design<\/td>\n<\/tr>\n<tr>\n<th>Foundation<\/th>\n<td>Level non-combustible foundation sized for the actual system<\/td>\n<\/tr>\n<tr>\n<th>Handling<\/th>\n<td>Professional lifting or forklift equipment<\/td>\n<\/tr>\n<tr>\n<th>Protection sensing<\/th>\n<td>Temperature and smoke<\/td>\n<\/tr>\n<tr>\n<th>Pack protection<\/th>\n<td>Aerosol system<\/td>\n<\/tr>\n<tr>\n<th>Pressure relief<\/th>\n<td>Pressure-relief valve<\/td>\n<\/tr>\n<tr>\n<th>Indication<\/th>\n<td>Audible and visual<\/td>\n<\/tr>\n<tr>\n<th>Fire-water connection<\/th>\n<td>DN65<\/td>\n<\/tr>\n<tr>\n<th>Fire-linkage output<\/th>\n<td>XT3:1 \/XT3:2<\/td>\n<\/tr>\n<tr>\n<th>Safety equipment configuration<\/th>\n<td>Aerosol, temperature and smoke detection, pressure valve, visual and audible indication<\/td>\n<\/tr>\n<tr>\n<th>Cell cycle test<\/th>\n<td>8000; 25\u00b12 \u00b0C; 0.5 P; SOH70 %<\/td>\n<\/tr>\n<tr>\n<th>Cycle-value applicability<\/th>\n<td>Cell-manufacturer data under test conditions<\/td>\n<\/tr>\n<tr>\n<th>Estimated delivery<\/th>\n<td>2\u20133 days, seller operating estimate<\/td>\n<\/tr>\n<tr>\n<th>Installation arrangement<\/th>\n<td>Engineered connection by qualified personnel<\/td>\n<\/tr>\n<tr>\n<th>Inverter pairing<\/th>\n<td>S6-EH3P50K-H(21A) included in system<\/td>\n<\/tr>\n<tr>\n<th>Grid charging<\/th>\n<td>Through the supplied hybrid inverter according to settings and design<\/td>\n<\/tr>\n<tr>\n<th>PV connection<\/th>\n<td>To MPPTs of the matching hybrid inverter<\/td>\n<\/tr>\n<tr>\n<th>Battery-bank setting<\/th>\n<td>1<\/td>\n<\/tr>\n<tr>\n<th>DC port connection<\/th>\n<td>Two inverter ports to one bank according to EverCore diagram<\/td>\n<\/tr>\n<tr>\n<th>Battery model in app<\/th>\n<td>SolisStorage<\/td>\n<\/tr>\n<tr>\n<th>DC expansion<\/th>\n<td>Additional matching cabinets through busbars according to design<\/td>\n<\/tr>\n<tr>\n<th>Linked-cabinet control<\/th>\n<td>EMU CAN \/Cat6a STP \/T568B<\/td>\n<\/tr>\n<tr>\n<th>Controller network<\/th>\n<td>WAN1 \/Ethernet \/TCP\/IP<\/td>\n<\/tr>\n<tr>\n<th>Cabinet-count configuration<\/th>\n<td>According to actually connected cabinets<\/td>\n<\/tr>\n<tr>\n<th>Monitoring<\/th>\n<td>SolisCloud and local EMU<\/td>\n<\/tr>\n<tr>\n<th>Commissioning<\/th>\n<td>Installer role, verification of wiring, grid, BMS and SOC<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Rated AC output<\/th>\n<td>50000 W<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Maximum DC voltage<\/th>\n<td>1000 V<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Rated DC voltage<\/th>\n<td>600 V<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Battery communication<\/th>\n<td>CAN \/RS485<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Grid connection<\/th>\n<td>3\/N\/PE; 220\/380 V; 230\/400 V<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Grid frequency<\/th>\n<td>50 \/60 Hz<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Power factor<\/th>\n<td>&gt;0.99; 0.8 leading \/lagging<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 THDi<\/th>\n<td>&lt;3 %<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Keys<\/th>\n<td>ESC \/UP \/DOWN \/ENTER<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Status LEDs<\/th>\n<td>POWER \/OPERATION \/ALARM<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 App roles<\/th>\n<td>Installer \/Owner<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Operating modes<\/th>\n<td>Self Use \/Selling First \/Off Grid \/Peak Shaving<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Grid charging<\/th>\n<td>Allow Grid Charging<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Time scheduling<\/th>\n<td>6 charging and 6 discharging windows<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Backup reserve<\/th>\n<td>5\u201395 % SOC; default 80 %<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Default maximum charge<\/th>\n<td>100 % SOC<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 SOC setting order<\/th>\n<td>Force Charge &lt;Over-discharge &lt;Recovery<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Export measurement calibration<\/th>\n<td>\u2212500\u2026+500 W; default 20 W<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Smart port \u2014 function selection<\/th>\n<td>Genset input \/AC coupled \/Smart load output<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 CT orientation<\/th>\n<td>Arrow towards grid<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 BMS CAN RJ45<\/th>\n<td>4 CAN-H \/5 CAN-L<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 BMS RS485 RJ45<\/th>\n<td>3 B \/6 A<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Meter RJ45<\/th>\n<td>1 A \/2 B<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Eastron terminals<\/th>\n<td>13 B \/14 A<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 DRM \u2014 remote shutdown<\/th>\n<td>RJ45 5 \/6; open shuts down within 5 s<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<th>Inverter \u2014 PV conductors<\/th>\n<td>4\u20136 mm\u00b2; recommended 4 mm\u00b2<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 PV stripping<\/th>\n<td>7 \u00b10.5 mm<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 AC stripping<\/th>\n<td>13 mm<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Ingress protection<\/th>\n<td>IP66<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Operating temperature<\/th>\n<td>\u221225\u2026+60 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Operating humidity<\/th>\n<td>0\u2013100 % RH<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Maximum AC apparent output<\/th>\n<td>50000 VA<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Rated backup output<\/th>\n<td>50000 W<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Peak backup output \/duration<\/th>\n<td>80000 VA \/2 s; 75000 VA \/10 s<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Backup transfer<\/th>\n<td>&lt;10 ms<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Maximum imbalance power per phase per manual<\/th>\n<td>33% rated power<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 THDv linear load<\/th>\n<td>&lt;2 %<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 MPPT count<\/th>\n<td>4<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 String count<\/th>\n<td>8<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Strings per MPPT<\/th>\n<td>2<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Input current per MPPT<\/th>\n<td>42 A<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Current per string<\/th>\n<td>21 A<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Short-circuit current per MPPT<\/th>\n<td>60 A<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Recommended PV array rating<\/th>\n<td>100 kWp<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Maximum usable PV power<\/th>\n<td>100 kW<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Start-up voltage<\/th>\n<td>180 V<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 MPPT range<\/th>\n<td>150\u2013850 V<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Battery type<\/th>\n<td>Compatible HV Li-ion battery system with BMS<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Battery voltage<\/th>\n<td>150\u2013800 V<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Battery port count<\/th>\n<td>2<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Maximum battery-port current<\/th>\n<td>80 A +80 A<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Current with combined inputs<\/th>\n<td>Up to 160 A in the corresponding battery arrangement<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Maximum total charge \/discharge power<\/th>\n<td>55 \/55 kW<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Maximum charge \/discharge power per port<\/th>\n<td>35 \/35 kW<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Battery operating limits<\/th>\n<td>Actual U\u00d7I, BMS, model-specific port and total-system limits<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 One battery \u2014 one port<\/th>\n<td>DC1 +BMS1<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Two batteries<\/th>\n<td>Each with its own DC input and BMS connection<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 One battery \u2014 two ports<\/th>\n<td>DC1 and DC2 connection according to diagram, communication BMS1<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Battery-bank settings<\/th>\n<td>Count 1\u20132, model, connection method, current and SOC of each bank<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Rated AC current at 380\/400 V<\/th>\n<td>76.0 \/72.2 A<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Maximum AC passthrough at 380\/400 V<\/th>\n<td>152.0 \/144.4 A<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Generator \u2014 maximum input power<\/th>\n<td>50 kW<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Generator \u2014 current at 380\/400 V<\/th>\n<td>76.0 \/72.2 A<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Generator \u2014 power selection per datasheet<\/th>\n<td>20\u2013100% rated power according to design<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Maximum efficiency<\/th>\n<td>97.7 %<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 European efficiency<\/th>\n<td>97.3 %<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 PV \u2192battery efficiency<\/th>\n<td>98.5 %<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Battery \u2194AC efficiency<\/th>\n<td>97.5 %<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 User interface<\/th>\n<td>7.0\u2033 LCD \/Bluetooth \/SolisCloud APP<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Bluetooth<\/th>\n<td>BDR \/EDR \/BLE; 2.402\u20132.480 GHz; 8 dBm<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 App sections<\/th>\n<td>Home \/Info \/Alarm \/Settings<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Operating information<\/th>\n<td>PV \/Battery \/Grid \/Load \/Inverter; SOC \/SOH; energy history and generator yield<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Diagnostics<\/th>\n<td>Current and historical alarms<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Initial settings<\/th>\n<td>Time, CT\/meter, grid code, operating mode and battery banks<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Over-discharge SOC<\/th>\n<td>5\u201340 %; default 20 %<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Force-charge SOC<\/th>\n<td>From 4% to selected over-discharge SOC<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Discharge recovery<\/th>\n<td>1\u201320 percentage points above over-discharge SOC<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Peak Shaving \u2014 settings<\/th>\n<td>With battery reserve enabled; default limit 2\u00d7rated power<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Generator \u2014 start \/stop SOC<\/th>\n<td>1\u201395 % \/35\u2013100 %<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 AC coupling \u2014 start \/stop SOC<\/th>\n<td>1\u201395 % \/35\u2013100 %<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Included standard meter<\/th>\n<td>Eastron SDM630MCT V2<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Standard CTs<\/th>\n<td>3 \u00d7ESCT-T50; 300 A \/5 A<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 CT cable length<\/th>\n<td>4 m<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Reference CT ratio<\/th>\n<td>60; according to actual CTs<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 CT \u2014 HM terminals<\/th>\n<td>White S1:1\/3\/5; black S2:2\/4\/6<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 External RS485<\/th>\n<td>5 A \/4 B; Modbus RTU<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 GEN \u2014 start contact<\/th>\n<td>GEN DO1:21 (+), 22 (\u2212), voltage-free contact<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Generator at Grid \u2014 status signal<\/th>\n<td>GEN DI:25 (+), 26 (\u2212); 0 V generator, 5\u201312 V grid<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Communication glands<\/th>\n<td>COM1\/COM2:6 mm; COM3\/COM4:2 mm<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Parallel system<\/th>\n<td>Up to 10 units according to project; manufacturer recommends STS cabinet above 6<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Parallel connection<\/th>\n<td>P-B \u2192P-A; shielded STP CAT5; normally 3\u20135 m between units<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Parallel-system addresses<\/th>\n<td>Master 1; further units according to diagram<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Parallel bus termination<\/th>\n<td>Endpoint DIPs ON, intermediate OFF according to diagram<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Parallel AC paths above 2 units<\/th>\n<td>Grid\/Backup cable-length difference to busbar within 10%<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Battery conductors<\/th>\n<td>10\u201325 mm\u00b2<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Battery \u2014 internal \/external stripping<\/th>\n<td>15 \u00b11 \/18 \u00b11 mm<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Battery connector \u2014 torque<\/th>\n<td>4 \u00b10.1 Nm<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Reference battery protection<\/th>\n<td>100 A \/\u22651000 VDC \/\u226550 kA according to design<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 AC Grid conductors<\/th>\n<td>50 mm\u00b2<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 AC Backup \/Smart conductors<\/th>\n<td>20\u201325 mm\u00b2<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 PE bar \u2014 conductor<\/th>\n<td>33 mm\u00b2<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 AC terminals \u2014 torque<\/th>\n<td>Grid 5.1 Nm; Backup\/Smart 3.4 Nm<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 PE bar \u2014 torque<\/th>\n<td>3.4 Nm<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 AC glands \u2014 torque<\/th>\n<td>7\u20137.5 Nm<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 External earth<\/th>\n<td>M5 \/3.5 Nm<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Reference AC protection<\/th>\n<td>Grid 4p160 A; Backup\/Smart 125 A according to design<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Bracket \u2014 overall width \/height<\/th>\n<td>497 \/452.5 mm<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Altitude<\/th>\n<td>4000 m<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Design DC voltage at 2000\/2700\/3000\/3500\/4000 m<\/th>\n<td>1000 \/1000 \/981 \/925 \/875 V<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Cooling<\/th>\n<td>Intelligent redundant fan cooling<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Noise per manual<\/th>\n<td>&lt;65 dB(A)<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Surge protection<\/th>\n<td>DC Type II \/AC Type II<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Package \u2014 main parts<\/th>\n<td>Inverter, backplate, quick guide, S2-WL-ST logger, meter and three CTs<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Package \u2014 fasteners<\/th>\n<td>4 fastening screws, 5 expansion bolts, 2 handles<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Package \u2014 connectors and communication<\/th>\n<td>8 \u00d7PV; 13 \u00d7OT; 2 \u00d7BAT; 11 \u00d7RJ45; 1 \u00d7CAN 3 m<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Battery operating point 150 V<\/th>\n<td>30 A \/4.5 kW (U\u00d7I)<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Battery operating point 324 V<\/th>\n<td>80 A \/25.92 kW (U\u00d7I)<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Battery operating point 400 V<\/th>\n<td>80 A \/32 kW (U\u00d7I)<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Battery operating point 500 V<\/th>\n<td>70 A \/35 kW<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Maximum power per phase<\/th>\n<td>33% rated power<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 Phase imbalance<\/th>\n<td>100 %<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 EMS protocol<\/th>\n<td>Modbus RTU<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 AC-coupled relay control<\/th>\n<td>AC C+ \/AC C\u2212; 12V output according to diagram<\/td>\n<\/tr>\n<tr>\n<th>Inverter \u2014 External emergency power off EPO<\/th>\n<td>19 (+) \/20 (\u2212); master also stops slaves<\/td>\n<\/tr>\n<tr>\n<th>System dimensions W \u00d7H \u00d7D<\/th>\n<td>1250 \u00d72030 \u00d71540 mm<\/td>\n<\/tr>\n<tr>\n<th>Power and energy pairing<\/th>\n<td>50 kW \/100.48 kWh<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2>Energy for business operations<\/h2>\n<p>EverCore 100 offers 100.48 kWh in LFP battery modules for commercial PV, peak-demand management and scheduled use of stored electricity. This system combines the outdoor battery cabinet with the Solis S6-EH3P50K-H(21A) hybrid inverter rated at 50 kW.<\/p>\n<h2>What the offer includes<\/h2>\n<p>The 100 kWh variant contains 5 battery packs with 100.48 kWh total nominal energy, battery management, EMU, PDU and an air-conditioning system. This offer also includes the specific S6-EH3P50K-H(21A) inverter. Cabinet and inverter form a system for professional interconnection at the prepared site.<\/p>\n<h2>Capacity and power serve different purposes<\/h2>\n<p>The 100.48 kWh capacity describes stored energy. Power determines which appliances and processes can operate simultaneously. The manual specifies up to 50 kW charging and discharging for the battery section; actual AC delivery also depends on the connected inverter, current voltage, BMS limits, SOC and temperature. An initial runtime estimate uses average demand in kW multiplied by operating hours, with allowance for losses and the desired backup reserve.<\/p>\n<h2>Modular LFP architecture<\/h2>\n<p>EVE MB31 cells combine 314 Ah capacity with LiFePO4 chemistry. The 5-pack assembly has 320 V nominal voltage and a 290\u2013360 V operating range. Each pack monitors its cells and communicates with higher-level management. The 8000-cycle figure refers to cell testing at 25\u00b12\u00b0C, 0.5 P and an end SOH of 70%, providing a technology comparison under the same test conditions.<\/p>\n<h2>Climate control for the battery<\/h2>\n<p>Industrial air conditioning provides cooling, heating, dehumidification and air circulation. The exact air-conditioner table specifies 3.2 kW cooling and 1 kW heating. The manual distinguishes charging ambient temperature of 0 to +55\u00b0C and discharging ambient temperature of \u221225 to +55\u00b0C. Thermal management and BMS coordinate conditions inside the system. The auxiliary supply rating is a connection-design figure; actual air-conditioner consumption varies with thermal load and operating mode.<\/p>\n<h2>PV, grid and backup<\/h2>\n<p>Paired with the matching S6-EH3P50K-H(21A) hybrid inverter, the cabinet supports direct PV charging through MPPTs, configured grid charging and supply to designated backup circuits. Self-use, selling-first and off-grid modes are selected according to site design. PV serves loads first; scheduling, SOC reserve and peak management align storage with business operation. Each proposed system is assessed for simultaneous demand, starting loads, phase distribution and required backup duration.<\/p>\n<h2>Protection layers and PRO configuration<\/h2>\n<p>Equipment combines battery supervision, temperature and smoke sensors, aerosol protection, a pressure valve and audible\/visual indication. The DN65 connection and fire-linkage output support integration into an engineered fire-protection design. This standard configuration contains the specifically described protective equipment; a separate PRO catalogue variant provides the additional detection and pressure-relief components.<\/p>\n<h2>EMU and SolisCloud<\/h2>\n<p>EMU brings together cabinet operating information and control links. SolisCloud provides visibility and configuration for the connected hybrid inverter; initial commissioning uses the installer role. Settings specify one battery bank, the SolisStorage model, the two-DC-port connection method and the actual cabinet count. Meter, CT-ratio and measurement-direction checks form part of commissioning. Auxiliary supply and Only PV Power Load \/ Grid To Load (Bypass) functions are configured for the selected backup arrangement.<\/p>\n<h2>Expansion designed as a system<\/h2>\n<p>Documentation covers DC expansion with matching cabinets on one inverter and AC-parallel systems using matching models. In an AC-parallel arrangement, each inverter has its assigned battery. EMUs use their own communication chain and controllers use Ethernet; inverter-parallel communication is separate. Unit count, backup transfer, any STS, conductor sizes, protection and firmware are engineered for the specific models and required power.<\/p>\n<h2>How to select the right system<\/h2>\n<p>Selection starts with average and simultaneous demand, operating duration and the required reserve. Nominal 100.48 kWh is the starting energy figure; usable SOC, efficiency and auxiliary systems affect delivered energy. Inverter selection follows kW, phases and starting requirements, while battery selection also checks voltage, current and BMS. EverCore uses a fixed engineered site with suitable load-bearing capacity, service access and electrical preparation. This connects energy requirements to a specific configuration instead of a single search keyword.<\/p>\n<h2>Delivery and connection planning<\/h2>\n<p>Delivery is planned together with transport and professional cabinet unloading. Dimensions and reference weights in the specifications support site preparation; the installation design defines foundation, clearances, earthing, protection and cable routes. During assembly, the inverter attaches to the prepared cabinet structure. This offer is defined by cabinet versus cabinet-with-inverter selection and standard versus PRO equipment. The estimated 2\u20133-day lead time is the seller\u2019s operating estimate.<\/p>\n<h2>Downloads<\/h2>\n<ul>\n<li><a href=\"https:\/\/batterado.com\/wp-content\/themes\/wodatherm\/assets\/documents\/products\/solis-evercore-100-system-en.md\">Complete product overview \u2014 Markdown<\/a><\/li>\n<\/ul>\n<section class=\"tomo-ai-search-profile\">\n<h2>AI search description<\/h2>\n<p>Solis EverCore 100 \u2014 100.48 kWh storage with 50 kW inverter. The 100 kWh variant contains 5 battery packs with 100.48 kWh total nominal energy, battery management, EMU, PDU and an air-conditioning system. This offer also includes the specific S6-EH3P50K-H(21A) inverter. Cabinet and inverter form a system for professional interconnection at the prepared site. Paired with the matching S6-EH3P50K-H(21A) hybrid inverter, the cabinet supports direct PV charging through MPPTs, configured grid charging and supply to designated backup circuits. Self-use, selling-first and off-grid modes are selected according to site design. PV serves loads first; scheduling, SOC reserve and peak management align storage with business operation. Each proposed system is assessed for simultaneous demand, starting loads, phase distribution and required backup duration.<\/p>\n<p>Manufacturer: Ginlong Energy Storage \/SolisStorage; Family: EverCore; Variant: 100 kWh; Device type: Battery storage system with inverter; Nominal energy: 100.48 kWh; Cell chemistry: LiFePO4 \/LFP; Cells: EVE MB31; Nominal cell voltage: 3.2 V; Cell capacity: 314 Ah; Battery pack count: 5; Pack model: PACK-1P20S-314-01; Pack configuration: 1P20S; Pack energy per manual: 20.10 kWh; Pack voltage: 64 V; Pack voltage range: 58\u201372 V; Pack weight: 138 kg; Pack dimensions W \u00d7H \u00d7D: 435 \u00d7230 \u00d7904 mm; Battery configuration: 1P100S; Total cell count: 100; Nominal DC voltage: 320 V; Operating DC voltage: 290\u2013360 V; Rated DC current: 157 A; Cycle rate: 0.5 P; Maximum battery charge power: 50 kW; Maximum battery discharge power: 50 kW; Actual power calculation: Voltage \u00d7current, BMS, SOC, temperature and connected inverter; Usable energy: According to SOC settings, reserve and operating losses; Battery management: BMU \/BCU \/EMU; Cell balancing: Passive; Communication protocols: CAN \/RS485 \/TCP\/IP; Battery-inverter communication: CAN \/BMS1; Cabinet controller: EMU; Power distribution: PDU; Cabinet cooling: Industrial air conditioning; Thermal modes: Cooling, heating, dehumidification and air circulation; Air-conditioner cooling capacity: 3.2 kW; Air-conditioner heating capacity: 1 kW; Refrigerant: R134a; Pack cooling: Air cooling; Auxiliary AC supply: 220 V AC; Auxiliary supply rating: 2.3 kW; Charging ambient temperature: 0\u2026+55 \u00b0C; Discharging ambient temperature: \u221225\u2026+55 \u00b0C; Cabinet storage temperature per manual: 0\u2026+40 \u00b0C; Operating humidity: \u226495 % non-condensing; Cabinet ingress protection: IP55; Quoted anti-corrosion configuration: C4H+C5 \/C5; Family noise at rated operation: 70 dB(A) @1 m; Cabinet dimensions W \u00d7H \u00d7D: 950 \u00d72030 \u00d71540 mm; Reference battery-cabinet weight: 1500 kg; Siting: Fixed outdoor location according to site design; Foundation: Level non-combustible foundation sized for the actual system; Handling: Professional lifting or forklift equipment; Protection sensing: Temperature and smoke; Pack protection: Aerosol system; Pressure relief: Pressure-relief valve; Indication: Audible and visual; Fire-water connection: DN65; Fire-linkage output: XT3:1 \/XT3:2; Safety equipment configuration: Aerosol, temperature and smoke detection, pressure valve, visual and audible indication; Cell cycle test: 8000; 25\u00b12 \u00b0C; 0.5 P; SOH70 %; Cycle-value applicability: Cell-manufacturer data under test conditions; Estimated delivery: 2\u20133 days, seller operating estimate; Installation arrangement: Engineered connection by qualified personnel; Inverter pairing: S6-EH3P50K-H(21A) included in system.<\/p>\n<p>Grid charging: Through the supplied hybrid inverter according to settings and design; PV connection: To MPPTs of the matching hybrid inverter; Battery-bank setting: 1; DC port connection: Two inverter ports to one bank according to EverCore diagram; Battery model in app: SolisStorage; DC expansion: Additional matching cabinets through busbars according to design; Linked-cabinet control: EMU CAN \/Cat6a STP \/T568B; Controller network: WAN1 \/Ethernet \/TCP\/IP; Cabinet-count configuration: According to actually connected cabinets; Monitoring: SolisCloud and local EMU; Commissioning: Installer role, verification of wiring, grid, BMS and SOC; Inverter \u2014 Rated AC output: 50000 W; Inverter \u2014 Maximum DC voltage: 1000 V; Inverter \u2014 Rated DC voltage: 600 V; Inverter \u2014 Battery communication: CAN \/RS485; Inverter \u2014 Grid connection: 3\/N\/PE; 220\/380 V; 230\/400 V; Inverter \u2014 Grid frequency: 50 \/60 Hz; Inverter \u2014 Power factor: &gt;0.99; 0.8 leading \/lagging; Inverter \u2014 THDi: &lt;3 %; Inverter \u2014 Keys: ESC \/UP \/DOWN \/ENTER; Inverter \u2014 Status LEDs: POWER \/OPERATION \/ALARM; Inverter \u2014 App roles: Installer \/Owner; Inverter \u2014 Operating modes: Self Use \/Selling First \/Off Grid \/Peak Shaving; Inverter \u2014 Grid charging: Allow Grid Charging; Inverter \u2014 Time scheduling: 6 charging and 6 discharging windows; Inverter \u2014 Backup reserve: 5\u201395 % SOC; default 80 %; Inverter \u2014 Default maximum charge: 100 % SOC; Inverter \u2014 SOC setting order: Force Charge &lt;Over-discharge &lt;Recovery; Inverter \u2014 Export measurement calibration: \u2212500\u2026+500 W; default 20 W; Inverter \u2014 Smart port \u2014 function selection: Genset input \/AC coupled \/Smart load output; Inverter \u2014 CT orientation: Arrow towards grid; Inverter \u2014 BMS CAN RJ45: 4 CAN-H \/5 CAN-L; Inverter \u2014 BMS RS485 RJ45: 3 B \/6 A; Inverter \u2014 Meter RJ45: 1 A \/2 B; Inverter \u2014 Eastron terminals: 13 B \/14 A; Inverter \u2014 DRM \u2014 remote shutdown: RJ45 5 \/6; open shuts down within 5 s; Inverter \u2014 PV conductors: 4\u20136 mm\u00b2; recommended 4 mm\u00b2; Inverter \u2014 PV stripping: 7 \u00b10.5 mm; Inverter \u2014 AC stripping: 13 mm; Inverter \u2014 Ingress protection: IP66; Inverter \u2014 Operating temperature: \u221225\u2026+60 \u00b0C; Inverter \u2014 Operating humidity: 0\u2013100 % RH; Inverter \u2014 Maximum AC apparent output: 50000 VA; Inverter \u2014 Rated backup output: 50000 W; Inverter \u2014 Peak backup output \/duration: 80000 VA \/2 s; 75000 VA \/10 s; Inverter \u2014 Backup transfer: &lt;10 ms; Inverter \u2014 Maximum imbalance power per phase per manual: 33% rated power; Inverter \u2014 THDv linear load: &lt;2 %; Inverter \u2014 MPPT count: 4; Inverter \u2014 String count: 8; Inverter \u2014 Strings per MPPT: 2; Inverter \u2014 Input current per MPPT: 42 A; Inverter \u2014 Current per string: 21 A; Inverter \u2014 Short-circuit current per MPPT: 60 A; Inverter \u2014 Recommended PV array rating: 100 kWp; Inverter \u2014 Maximum usable PV power: 100 kW; Inverter \u2014 Start-up voltage: 180 V; Inverter \u2014 MPPT range: 150\u2013850 V; Inverter \u2014 Battery type: Compatible HV Li-ion battery system with BMS; Inverter \u2014 Battery voltage: 150\u2013800 V; Inverter \u2014 Battery port count: 2; Inverter \u2014 Maximum battery-port current: 80 A +80 A; Inverter \u2014 Current with combined inputs: Up to 160 A in the corresponding battery arrangement; Inverter \u2014 Maximum total charge \/discharge power: 55 \/55 kW; Inverter \u2014 Maximum charge \/discharge power per port: 35 \/35 kW; Inverter \u2014 Battery operating limits: Actual U\u00d7I, BMS, model-specific port and total-system limits; Inverter \u2014 One battery \u2014 one port: DC1 +BMS1; Inverter \u2014 Two batteries: Each with its own DC input and BMS connection; Inverter \u2014 One battery \u2014 two ports: DC1 and DC2 connection according to diagram, communication BMS1; Inverter \u2014 Battery-bank settings: Count 1\u20132, model, connection method, current and SOC of each bank; Inverter \u2014 Rated AC current at 380\/400 V: 76.0 \/72.2 A; Inverter \u2014 Maximum AC passthrough at 380\/400 V: 152.0 \/144.4 A; Inverter \u2014 Generator \u2014 maximum input power: 50 kW; Inverter \u2014 Generator \u2014 current at 380\/400 V: 76.0 \/72.2 A; Inverter \u2014 Generator \u2014 power selection per datasheet: 20\u2013100% rated power according to design; Inverter \u2014 Maximum efficiency: 97.7 %; Inverter \u2014 European efficiency: 97.3 %; Inverter \u2014 PV \u2192battery efficiency: 98.5 %; Inverter \u2014 Battery \u2194AC efficiency: 97.5 %; Inverter \u2014 User interface: 7.0\u2033 LCD \/Bluetooth \/SolisCloud APP; Inverter \u2014 Bluetooth: BDR \/EDR \/BLE; 2.402\u20132.480 GHz; 8 dBm; Inverter \u2014 App sections: Home \/Info \/Alarm \/Settings; Inverter \u2014 Operating information: PV \/Battery \/Grid \/Load \/Inverter; SOC \/SOH; energy history and generator yield; Inverter \u2014 Diagnostics: Current and historical alarms; Inverter \u2014 Initial settings: Time, CT\/meter, grid code, operating mode and battery banks; Inverter \u2014 Over-discharge SOC: 5\u201340 %; default 20 %; Inverter \u2014 Force-charge SOC: From 4% to selected over-discharge SOC; Inverter \u2014 Discharge recovery: 1\u201320 percentage points above over-discharge SOC; Inverter \u2014 Peak Shaving \u2014 settings: With battery reserve enabled; default limit 2\u00d7rated power; Inverter \u2014 Generator \u2014 start \/stop SOC: 1\u201395 % \/35\u2013100 %; Inverter \u2014 AC coupling \u2014 start \/stop SOC: 1\u201395 % \/35\u2013100 %; Inverter \u2014 Included standard meter: Eastron SDM630MCT V2; Inverter \u2014 Standard CTs: 3 \u00d7ESCT-T50; 300 A \/5 A; Inverter \u2014 CT cable length: 4 m; Inverter \u2014 Reference CT ratio: 60; according to actual CTs; Inverter \u2014 CT \u2014 HM terminals: White S1:1\/3\/5; black S2:2\/4\/6; Inverter \u2014 External RS485: 5 A \/4 B; Modbus RTU; Inverter \u2014 GEN \u2014 start contact: GEN DO1:21 (+), 22 (\u2212), voltage-free contact; Inverter \u2014 Generator at Grid \u2014 status signal: GEN DI:25 (+), 26 (\u2212); 0 V generator, 5\u201312 V grid; Inverter \u2014 Communication glands: COM1\/COM2:6 mm; COM3\/COM4:2 mm; Inverter \u2014 Parallel system: Up to 10 units according to project; manufacturer recommends STS cabinet above 6; Inverter \u2014 Parallel connection: P-B \u2192P-A; shielded STP CAT5; normally 3\u20135 m between units; Inverter \u2014 Parallel-system addresses: Master 1; further units according to diagram; Inverter \u2014 Parallel bus termination: Endpoint DIPs ON, intermediate OFF according to diagram; Inverter \u2014 Parallel AC paths above 2 units: Grid\/Backup cable-length difference to busbar within 10%; Inverter \u2014 Battery conductors: 10\u201325 mm\u00b2; Inverter \u2014 Battery \u2014 internal \/external stripping: 15 \u00b11 \/18 \u00b11 mm; Inverter \u2014 Battery connector \u2014 torque: 4 \u00b10.1 Nm; Inverter \u2014 Reference battery protection: 100 A \/\u22651000 VDC \/\u226550 kA according to design; Inverter \u2014 AC Grid conductors: 50 mm\u00b2; Inverter \u2014 AC Backup \/Smart conductors: 20\u201325 mm\u00b2; Inverter \u2014 PE bar \u2014 conductor: 33 mm\u00b2; Inverter \u2014 AC terminals \u2014 torque: Grid 5.1 Nm; Backup\/Smart 3.4 Nm; Inverter \u2014 PE bar \u2014 torque: 3.4 Nm; Inverter \u2014 AC glands \u2014 torque: 7\u20137.5 Nm; Inverter \u2014 External earth: M5 \/3.5 Nm; Inverter \u2014 Reference AC protection: Grid 4p160 A; Backup\/Smart 125 A according to design; Inverter \u2014 Bracket \u2014 overall width \/height: 497 \/452.5 mm; Inverter \u2014 Altitude: 4000 m; Inverter \u2014 Design DC voltage at 2000\/2700\/3000\/3500\/4000 m: 1000 \/1000 \/981 \/925 \/875 V; Inverter \u2014 Cooling: Intelligent redundant fan cooling; Inverter \u2014 Noise per manual: &lt;65 dB(A); Inverter \u2014 Surge protection: DC Type II \/AC Type II; Inverter \u2014 Package \u2014 main parts: Inverter, backplate, quick guide, S2-WL-ST logger, meter and three CTs; Inverter \u2014 Package \u2014 fasteners: 4 fastening screws, 5 expansion bolts, 2 handles; Inverter \u2014 Package \u2014 connectors and communication: 8 \u00d7PV; 13 \u00d7OT; 2 \u00d7BAT; 11 \u00d7RJ45; 1 \u00d7CAN 3 m; Inverter \u2014 Battery operating point 150 V: 30 A \/4.5 kW (U\u00d7I); Inverter \u2014 Battery operating point 324 V: 80 A \/25.92 kW (U\u00d7I); Inverter \u2014 Battery operating point 400 V: 80 A \/32 kW (U\u00d7I); Inverter \u2014 Battery operating point 500 V: 70 A \/35 kW; Inverter \u2014 Maximum power per phase: 33% rated power; Inverter \u2014 Phase imbalance: 100 %; Inverter \u2014 EMS protocol: Modbus RTU; Inverter \u2014 AC-coupled relay control: AC C+ \/AC C\u2212; 12V output according to diagram; Inverter \u2014 External emergency power off EPO: 19 (+) \/20 (\u2212); master also stops slaves; System dimensions W \u00d7H \u00d7D: 1250 \u00d72030 \u00d71540 mm; Power and energy pairing: 50 kW \/100.48 kWh. Selection starts with average and simultaneous demand, operating duration and the required reserve. Nominal 100.48 kWh is the starting energy figure; usable SOC, efficiency and auxiliary systems affect delivered energy. Inverter selection follows kW, phases and starting requirements, while battery selection also checks voltage, current and BMS. EverCore uses a fixed engineered site with suitable load-bearing capacity, service access and electrical preparation. This connects energy requirements to a specific configuration instead of a single search keyword.<\/p>\n<p><a href=\"https:\/\/batterado.com\/product\/solis-evercore-100-system\/\">Batterado \u2014 SOLIS-EVERCORE-100-SYSTEM<\/a><\/p>\n<p><a href=\"https:\/\/batterado.com\/wp-content\/themes\/wodatherm\/assets\/documents\/products\/solis-evercore-100-system-en.md\">Markdown \u2014 SOLIS-EVERCORE-100-SYSTEM<\/a><\/p>\n<\/section>\n","protected":false},"excerpt":{"rendered":"<p>EverCore 100 offers 100.48 kWh in LFP battery modules for commercial PV, peak-demand management and scheduled use of stored electricity. This system combines the outdoor battery cabinet with the Solis S6-EH3P50K-H(21A) hybrid inverter rated at 50 kW.<\/p>\n","protected":false},"featured_media":59452,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[2881],"product_cat":[3214,2760],"product_tag":[2925,3526,2861,3519],"class_list":["post-59164","product","type-product","status-publish","has-post-thumbnail","product_brand-solis-storage-energy","product_cat-battery-inverter-systems","product_cat-outdoor-battery-storage","product_tag-commercial-energy-storage","product_tag-solis-evercore-100-system","product_tag-lifepo4","product_tag-solis-evercore","first","onbackorder","taxable","shipping-taxable","purchasable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product\/59164","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/comments?post=59164"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/media\/59452"}],"wp:attachment":[{"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/media?parent=59164"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product_brand?post=59164"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product_cat?post=59164"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product_tag?post=59164"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}