{"id":59140,"date":"2026-11-01T06:06:40","date_gmt":"2026-11-01T04:06:40","guid":{"rendered":"https:\/\/batterado.com\/?post_type=product&#038;p=59140"},"modified":"2026-11-01T11:11:26","modified_gmt":"2026-11-01T09:11:26","slug":"solis-evercore-100-cabinet","status":"publish","type":"product","link":"https:\/\/batterado.com\/en\/product\/solis-evercore-100-cabinet\/","title":{"rendered":"Solis EverCore 100 \u2014 100.48 kWh outdoor battery cabinet"},"content":{"rendered":"<h2>Technical specifications<\/h2>\n<div class=\"wt-tech-grid\">\n<table>\n<tbody>\n<tr>\n<th>Manufacturer<\/th>\n<td>Ginlong Energy Storage \/SolisStorage<\/td>\n<\/tr>\n<tr>\n<th>Family<\/th>\n<td>EverCore<\/td>\n<\/tr>\n<tr>\n<th>Variant<\/th>\n<td>100 kWh<\/td>\n<\/tr>\n<tr>\n<th>Device type<\/th>\n<td>Outdoor HV battery cabinet<\/td>\n<\/tr>\n<tr>\n<th>Nominal energy<\/th>\n<td>100.48 kWh<\/td>\n<\/tr>\n<tr>\n<th>Cell chemistry<\/th>\n<td>LiFePO4 \/LFP<\/td>\n<\/tr>\n<tr>\n<th>Cells<\/th>\n<td>EVE MB31<\/td>\n<\/tr>\n<tr>\n<th>Nominal cell voltage<\/th>\n<td>3.2 V<\/td>\n<\/tr>\n<tr>\n<th>Cell capacity<\/th>\n<td>314 Ah<\/td>\n<\/tr>\n<tr>\n<th>Battery pack count<\/th>\n<td>5<\/td>\n<\/tr>\n<tr>\n<th>Pack model<\/th>\n<td>PACK-1P20S-314-01<\/td>\n<\/tr>\n<tr>\n<th>Pack configuration<\/th>\n<td>1P20S<\/td>\n<\/tr>\n<tr>\n<th>Pack energy per manual<\/th>\n<td>20.10 kWh<\/td>\n<\/tr>\n<tr>\n<th>Pack voltage<\/th>\n<td>64 V<\/td>\n<\/tr>\n<tr>\n<th>Pack voltage range<\/th>\n<td>58\u201372 V<\/td>\n<\/tr>\n<tr>\n<th>Pack weight<\/th>\n<td>138 kg<\/td>\n<\/tr>\n<tr>\n<th>Pack dimensions W \u00d7H \u00d7D<\/th>\n<td>435 \u00d7230 \u00d7904 mm<\/td>\n<\/tr>\n<tr>\n<th>Battery configuration<\/th>\n<td>1P100S<\/td>\n<\/tr>\n<tr>\n<th>Total cell count<\/th>\n<td>100<\/td>\n<\/tr>\n<tr>\n<th>Nominal DC voltage<\/th>\n<td>320 V<\/td>\n<\/tr>\n<tr>\n<th>Operating DC voltage<\/th>\n<td>290\u2013360 V<\/td>\n<\/tr>\n<tr>\n<th>Rated DC current<\/th>\n<td>157 A<\/td>\n<\/tr>\n<tr>\n<th>Cycle rate<\/th>\n<td>0.5 P<\/td>\n<\/tr>\n<tr>\n<th>Maximum battery charge power<\/th>\n<td>50 kW<\/td>\n<\/tr>\n<tr>\n<th>Maximum battery discharge power<\/th>\n<td>50 kW<\/td>\n<\/tr>\n<tr>\n<th>Actual power calculation<\/th>\n<td>Voltage \u00d7current, BMS, SOC, temperature and connected inverter<\/td>\n<\/tr>\n<tr>\n<th>Usable energy<\/th>\n<td>According to SOC settings, reserve and operating losses<\/td>\n<\/tr>\n<tr>\n<th>Battery management<\/th>\n<td>BMU \/BCU \/EMU<\/td>\n<\/tr>\n<tr>\n<th>Cell balancing<\/th>\n<td>Passive<\/td>\n<\/tr>\n<tr>\n<th>Communication protocols<\/th>\n<td>CAN \/RS485 \/TCP\/IP<\/td>\n<\/tr>\n<tr>\n<th>Battery-inverter communication<\/th>\n<td>CAN \/BMS1<\/td>\n<\/tr>\n<tr>\n<th>Cabinet controller<\/th>\n<td>EMU<\/td>\n<\/tr>\n<tr>\n<th>Power distribution<\/th>\n<td>PDU<\/td>\n<\/tr>\n<tr>\n<th>Cabinet cooling<\/th>\n<td>Industrial air conditioning<\/td>\n<\/tr>\n<tr>\n<th>Thermal modes<\/th>\n<td>Cooling, heating, dehumidification and air circulation<\/td>\n<\/tr>\n<tr>\n<th>Air-conditioner cooling capacity<\/th>\n<td>3.2 kW<\/td>\n<\/tr>\n<tr>\n<th>Air-conditioner heating capacity<\/th>\n<td>1 kW<\/td>\n<\/tr>\n<tr>\n<th>Refrigerant<\/th>\n<td>R134a<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<th>Pack cooling<\/th>\n<td>Air cooling<\/td>\n<\/tr>\n<tr>\n<th>Auxiliary AC supply<\/th>\n<td>220 V AC<\/td>\n<\/tr>\n<tr>\n<th>Auxiliary supply rating<\/th>\n<td>2.3 kW<\/td>\n<\/tr>\n<tr>\n<th>Charging ambient temperature<\/th>\n<td>0\u2026+55 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th>Discharging ambient temperature<\/th>\n<td>\u221225\u2026+55 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th>Cabinet storage temperature per manual<\/th>\n<td>0\u2026+40 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th>Operating humidity<\/th>\n<td>\u226495 % non-condensing<\/td>\n<\/tr>\n<tr>\n<th>Cabinet ingress protection<\/th>\n<td>IP55<\/td>\n<\/tr>\n<tr>\n<th>Quoted anti-corrosion configuration<\/th>\n<td>C4H+C5 \/C5<\/td>\n<\/tr>\n<tr>\n<th>Family noise at rated operation<\/th>\n<td>70 dB(A) @1 m<\/td>\n<\/tr>\n<tr>\n<th>Cabinet dimensions W \u00d7H \u00d7D<\/th>\n<td>950 \u00d72030 \u00d71540 mm<\/td>\n<\/tr>\n<tr>\n<th>Reference battery-cabinet weight<\/th>\n<td>1500 kg<\/td>\n<\/tr>\n<tr>\n<th>Siting<\/th>\n<td>Fixed outdoor location according to site design<\/td>\n<\/tr>\n<tr>\n<th>Foundation<\/th>\n<td>Level non-combustible foundation sized for the actual system<\/td>\n<\/tr>\n<tr>\n<th>Handling<\/th>\n<td>Professional lifting or forklift equipment<\/td>\n<\/tr>\n<tr>\n<th>Protection sensing<\/th>\n<td>Temperature and smoke<\/td>\n<\/tr>\n<tr>\n<th>Pack protection<\/th>\n<td>Aerosol system<\/td>\n<\/tr>\n<tr>\n<th>Pressure relief<\/th>\n<td>Pressure-relief valve<\/td>\n<\/tr>\n<tr>\n<th>Indication<\/th>\n<td>Audible and visual<\/td>\n<\/tr>\n<tr>\n<th>Fire-water connection<\/th>\n<td>DN65<\/td>\n<\/tr>\n<tr>\n<th>Fire-linkage output<\/th>\n<td>XT3:1 \/XT3:2<\/td>\n<\/tr>\n<tr>\n<th>Safety equipment configuration<\/th>\n<td>Aerosol, temperature and smoke detection, pressure valve, visual and audible indication<\/td>\n<\/tr>\n<tr>\n<th>Cell cycle test<\/th>\n<td>8000; 25\u00b12 \u00b0C; 0.5 P; SOH70 %<\/td>\n<\/tr>\n<tr>\n<th>Cycle-value applicability<\/th>\n<td>Cell-manufacturer data under test conditions<\/td>\n<\/tr>\n<tr>\n<th>Estimated delivery<\/th>\n<td>2\u20133 days, seller operating estimate<\/td>\n<\/tr>\n<tr>\n<th>Installation arrangement<\/th>\n<td>Engineered connection by qualified personnel<\/td>\n<\/tr>\n<tr>\n<th>Inverter pairing<\/th>\n<td>S6-EH3P50K-H(21A) \u2014 matching EverCore configuration<\/td>\n<\/tr>\n<tr>\n<th>Grid charging<\/th>\n<td>Through a matching connected hybrid inverter<\/td>\n<\/tr>\n<tr>\n<th>PV connection<\/th>\n<td>To MPPTs of the matching hybrid inverter<\/td>\n<\/tr>\n<tr>\n<th>Battery-bank setting<\/th>\n<td>1<\/td>\n<\/tr>\n<tr>\n<th>DC port connection<\/th>\n<td>Two inverter ports to one bank according to EverCore diagram<\/td>\n<\/tr>\n<tr>\n<th>Battery model in app<\/th>\n<td>SolisStorage<\/td>\n<\/tr>\n<tr>\n<th>DC expansion<\/th>\n<td>Additional matching cabinets through busbars according to design<\/td>\n<\/tr>\n<tr>\n<th>Linked-cabinet control<\/th>\n<td>EMU CAN \/Cat6a STP \/T568B<\/td>\n<\/tr>\n<tr>\n<th>Controller network<\/th>\n<td>WAN1 \/Ethernet \/TCP\/IP<\/td>\n<\/tr>\n<tr>\n<th>Cabinet-count configuration<\/th>\n<td>According to actually connected cabinets<\/td>\n<\/tr>\n<tr>\n<th>Monitoring<\/th>\n<td>SolisCloud and local EMU<\/td>\n<\/tr>\n<tr>\n<th>Commissioning<\/th>\n<td>Installer role, verification of wiring, grid, BMS and SOC<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2>Energy for business operations<\/h2>\n<p>EverCore 100 offers 100.48 kWh in LFP battery modules for commercial PV, peak-demand management and scheduled use of stored electricity. This offer contains the outdoor battery cabinet with EMU, power distribution and active air conditioning, ready for a matching Solis hybrid inverter.<\/p>\n<h2>What the offer includes<\/h2>\n<p>The 100 kWh variant contains 5 battery packs with 100.48 kWh total nominal energy, battery management, EMU, PDU and an air-conditioning system. The AC system is formed by connecting a matching inverter; the documented configuration for this capacity uses S6-EH3P50K-H(21A). Inverter selection and wiring follow the voltage range, current, BMS and site design.<\/p>\n<h2>Capacity and power serve different purposes<\/h2>\n<p>The 100.48 kWh capacity describes stored energy. Power determines which appliances and processes can operate simultaneously. The manual specifies up to 50 kW charging and discharging for the battery section; actual AC delivery also depends on the connected inverter, current voltage, BMS limits, SOC and temperature. An initial runtime estimate uses average demand in kW multiplied by operating hours, with allowance for losses and the desired backup reserve.<\/p>\n<h2>Modular LFP architecture<\/h2>\n<p>EVE MB31 cells combine 314 Ah capacity with LiFePO4 chemistry. The 5-pack assembly has 320 V nominal voltage and a 290\u2013360 V operating range. Each pack monitors its cells and communicates with higher-level management. The 8000-cycle figure refers to cell testing at 25\u00b12\u00b0C, 0.5 P and an end SOH of 70%, providing a technology comparison under the same test conditions.<\/p>\n<h2>Climate control for the battery<\/h2>\n<p>Industrial air conditioning provides cooling, heating, dehumidification and air circulation. The exact air-conditioner table specifies 3.2 kW cooling and 1 kW heating. The manual distinguishes charging ambient temperature of 0 to +55\u00b0C and discharging ambient temperature of \u221225 to +55\u00b0C. Thermal management and BMS coordinate conditions inside the system. The auxiliary supply rating is a connection-design figure; actual air-conditioner consumption varies with thermal load and operating mode.<\/p>\n<h2>PV, grid and backup<\/h2>\n<p>Paired with the matching S6-EH3P50K-H(21A) hybrid inverter, the cabinet supports direct PV charging through MPPTs, configured grid charging and supply to designated backup circuits. Self-use, selling-first and off-grid modes are selected according to site design. PV serves loads first; scheduling, SOC reserve and peak management align storage with business operation. Each proposed system is assessed for simultaneous demand, starting loads, phase distribution and required backup duration.<\/p>\n<h2>Protection layers and PRO configuration<\/h2>\n<p>Equipment combines battery supervision, temperature and smoke sensors, aerosol protection, a pressure valve and audible\/visual indication. The DN65 connection and fire-linkage output support integration into an engineered fire-protection design. This standard configuration contains the specifically described protective equipment; a separate PRO catalogue variant provides the additional detection and pressure-relief components.<\/p>\n<h2>EMU and SolisCloud<\/h2>\n<p>EMU brings together cabinet operating information and control links. SolisCloud provides visibility and configuration for the connected hybrid inverter; initial commissioning uses the installer role. Settings specify one battery bank, the SolisStorage model, the two-DC-port connection method and the actual cabinet count. Meter, CT-ratio and measurement-direction checks form part of commissioning. Auxiliary supply and Only PV Power Load \/ Grid To Load (Bypass) functions are configured for the selected backup arrangement.<\/p>\n<h2>Expansion designed as a system<\/h2>\n<p>Documentation covers DC expansion with matching cabinets on one inverter and AC-parallel systems using matching models. In an AC-parallel arrangement, each inverter has its assigned battery. EMUs use their own communication chain and controllers use Ethernet; inverter-parallel communication is separate. Unit count, backup transfer, any STS, conductor sizes, protection and firmware are engineered for the specific models and required power.<\/p>\n<h2>How to select the right system<\/h2>\n<p>Selection starts with average and simultaneous demand, operating duration and the required reserve. Nominal 100.48 kWh is the starting energy figure; usable SOC, efficiency and auxiliary systems affect delivered energy. Inverter selection follows kW, phases and starting requirements, while battery selection also checks voltage, current and BMS. EverCore uses a fixed engineered site with suitable load-bearing capacity, service access and electrical preparation. This connects energy requirements to a specific configuration instead of a single search keyword.<\/p>\n<h2>Delivery and connection planning<\/h2>\n<p>Delivery is planned together with transport and professional cabinet unloading. Dimensions and reference weights in the specifications support site preparation; the installation design defines foundation, clearances, earthing, protection and cable routes. During assembly, the inverter attaches to the prepared cabinet structure. This offer is defined by cabinet versus cabinet-with-inverter selection and standard versus PRO equipment. The estimated 2\u20133-day lead time is the seller\u2019s operating estimate.<\/p>\n<h2>Downloads<\/h2>\n<ul>\n<li><a href=\"https:\/\/batterado.com\/wp-content\/themes\/wodatherm\/assets\/documents\/products\/solis-evercore-100-cabinet-en.md\">Complete product overview \u2014 Markdown<\/a><\/li>\n<\/ul>\n<section class=\"tomo-ai-search-profile\">\n<h2>AI search description<\/h2>\n<p>Solis EverCore 100 \u2014 100.48 kWh outdoor battery cabinet. The 100 kWh variant contains 5 battery packs with 100.48 kWh total nominal energy, battery management, EMU, PDU and an air-conditioning system. The AC system is formed by connecting a matching inverter; the documented configuration for this capacity uses S6-EH3P50K-H(21A). Inverter selection and wiring follow the voltage range, current, BMS and site design. Paired with the matching S6-EH3P50K-H(21A) hybrid inverter, the cabinet supports direct PV charging through MPPTs, configured grid charging and supply to designated backup circuits. Self-use, selling-first and off-grid modes are selected according to site design. PV serves loads first; scheduling, SOC reserve and peak management align storage with business operation. Each proposed system is assessed for simultaneous demand, starting loads, phase distribution and required backup duration.<\/p>\n<p>Manufacturer: Ginlong Energy Storage \/SolisStorage; Family: EverCore; Variant: 100 kWh; Device type: Outdoor HV battery cabinet; Nominal energy: 100.48 kWh; Cell chemistry: LiFePO4 \/LFP; Cells: EVE MB31; Nominal cell voltage: 3.2 V; Cell capacity: 314 Ah; Battery pack count: 5; Pack model: PACK-1P20S-314-01; Pack configuration: 1P20S; Pack energy per manual: 20.10 kWh; Pack voltage: 64 V; Pack voltage range: 58\u201372 V; Pack weight: 138 kg; Pack dimensions W \u00d7H \u00d7D: 435 \u00d7230 \u00d7904 mm; Battery configuration: 1P100S; Total cell count: 100; Nominal DC voltage: 320 V; Operating DC voltage: 290\u2013360 V; Rated DC current: 157 A; Cycle rate: 0.5 P; Maximum battery charge power: 50 kW; Maximum battery discharge power: 50 kW; Actual power calculation: Voltage \u00d7current, BMS, SOC, temperature and connected inverter; Usable energy: According to SOC settings, reserve and operating losses; Battery management: BMU \/BCU \/EMU; Cell balancing: Passive; Communication protocols: CAN \/RS485 \/TCP\/IP; Battery-inverter communication: CAN \/BMS1; Cabinet controller: EMU; Power distribution: PDU; Cabinet cooling: Industrial air conditioning; Thermal modes: Cooling, heating, dehumidification and air circulation; Air-conditioner cooling capacity: 3.2 kW; Air-conditioner heating capacity: 1 kW; Refrigerant: R134a; Pack cooling: Air cooling; Auxiliary AC supply: 220 V AC; Auxiliary supply rating: 2.3 kW; Charging ambient temperature: 0\u2026+55 \u00b0C; Discharging ambient temperature: \u221225\u2026+55 \u00b0C; Cabinet storage temperature per manual: 0\u2026+40 \u00b0C; Operating humidity: \u226495 % non-condensing; Cabinet ingress protection: IP55; Quoted anti-corrosion configuration: C4H+C5 \/C5; Family noise at rated operation: 70 dB(A) @1 m; Cabinet dimensions W \u00d7H \u00d7D: 950 \u00d72030 \u00d71540 mm; Reference battery-cabinet weight: 1500 kg; Siting: Fixed outdoor location according to site design; Foundation: Level non-combustible foundation sized for the actual system; Handling: Professional lifting or forklift equipment; Protection sensing: Temperature and smoke; Pack protection: Aerosol system; Pressure relief: Pressure-relief valve; Indication: Audible and visual; Fire-water connection: DN65; Fire-linkage output: XT3:1 \/XT3:2; Safety equipment configuration: Aerosol, temperature and smoke detection, pressure valve, visual and audible indication; Cell cycle test: 8000; 25\u00b12 \u00b0C; 0.5 P; SOH70 %; Cycle-value applicability: Cell-manufacturer data under test conditions; Estimated delivery: 2\u20133 days, seller operating estimate; Installation arrangement: Engineered connection by qualified personnel; Inverter pairing: S6-EH3P50K-H(21A) \u2014 matching EverCore configuration.<\/p>\n<p>Grid charging: Through a matching connected hybrid inverter; PV connection: To MPPTs of the matching hybrid inverter; Battery-bank setting: 1; DC port connection: Two inverter ports to one bank according to EverCore diagram; Battery model in app: SolisStorage; DC expansion: Additional matching cabinets through busbars according to design; Linked-cabinet control: EMU CAN \/Cat6a STP \/T568B; Controller network: WAN1 \/Ethernet \/TCP\/IP; Cabinet-count configuration: According to actually connected cabinets; Monitoring: SolisCloud and local EMU; Commissioning: Installer role, verification of wiring, grid, BMS and SOC. Selection starts with average and simultaneous demand, operating duration and the required reserve. Nominal 100.48 kWh is the starting energy figure; usable SOC, efficiency and auxiliary systems affect delivered energy. Inverter selection follows kW, phases and starting requirements, while battery selection also checks voltage, current and BMS. EverCore uses a fixed engineered site with suitable load-bearing capacity, service access and electrical preparation. This connects energy requirements to a specific configuration instead of a single search keyword.<\/p>\n<p><a href=\"https:\/\/batterado.com\/product\/solis-evercore-100-cabinet\/\">Batterado \u2014 SOLIS-EVERCORE-100-CABINET<\/a><\/p>\n<p><a href=\"https:\/\/batterado.com\/wp-content\/themes\/wodatherm\/assets\/documents\/products\/solis-evercore-100-cabinet-en.md\">Markdown \u2014 SOLIS-EVERCORE-100-CABINET<\/a><\/p>\n<\/section>\n","protected":false},"excerpt":{"rendered":"<p>EverCore 100 offers 100.48 kWh in LFP battery modules for commercial PV, peak-demand management and scheduled use of stored electricity. This offer contains the outdoor battery cabinet with EMU, power distribution and active air conditioning, ready for a matching Solis hybrid inverter.<\/p>\n","protected":false},"featured_media":59449,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[2881],"product_cat":[2912,2760],"product_tag":[2925,3520,2861,3519],"class_list":["post-59140","product","type-product","status-publish","has-post-thumbnail","product_brand-solis-storage-energy","product_cat-batteries-with-bms","product_cat-outdoor-battery-storage","product_tag-commercial-energy-storage","product_tag-solis-evercore-100-cabinet","product_tag-lifepo4","product_tag-solis-evercore","first","onbackorder","taxable","shipping-taxable","purchasable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product\/59140","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/comments?post=59140"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/media\/59449"}],"wp:attachment":[{"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/media?parent=59140"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product_brand?post=59140"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product_cat?post=59140"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product_tag?post=59140"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}