{"id":59089,"date":"2026-11-01T05:52:16","date_gmt":"2026-11-01T03:52:16","guid":{"rendered":"https:\/\/batterado.com\/?post_type=product&#038;p=59089"},"modified":"2026-11-01T11:01:16","modified_gmt":"2026-11-01T09:01:16","slug":"solis-s6-eh3p100k10-nv-yd-h-afci-hybridni-stridac","status":"publish","type":"product","link":"https:\/\/batterado.com\/en\/product\/solis-s6-eh3p100k10-nv-yd-h-afci-hybridni-stridac\/","title":{"rendered":"Solis S6-EH3P100K10-NV-YD-H AFCI 2.0 \u2014 100 kW hybrid inverter, 10 MPPTs, dual HV ports"},"content":{"rendered":"<h2>Technical specifications<\/h2>\n<div class=\"wt-tech-grid\">\n<table>\n<tbody>\n<tr>\n<th>Manufacturer<\/th>\n<td>Solis \/ Ginlong Technologies<\/td>\n<\/tr>\n<tr>\n<th>Manufacturer model<\/th>\n<td>S6-EH3P100K10-NV-YD-H<\/td>\n<\/tr>\n<tr>\n<th>Device type<\/th>\n<td>Three-phase hybrid inverter for PV and HV battery<\/td>\n<\/tr>\n<tr>\n<th>Offered configuration<\/th>\n<td>DC switches, Wi-Fi\/LAN, LCD, meter, DC\/AC SPD II, AFCI 2.0<\/td>\n<\/tr>\n<tr>\n<th>Rated AC output<\/th>\n<td>100000 W<\/td>\n<\/tr>\n<tr>\n<th>Storage capacity<\/th>\n<td>In kWh according to selected battery system<\/td>\n<\/tr>\n<tr>\n<th>Battery matching<\/th>\n<td>Exact model, module count, voltage, BMS, firmware and current capability<\/td>\n<\/tr>\n<tr>\n<th>Grid connection<\/th>\n<td>3\/N\/PE; 220\/380 V; 230\/400 V<\/td>\n<\/tr>\n<tr>\n<th>Grid frequency<\/th>\n<td>50 \/60 Hz<\/td>\n<\/tr>\n<tr>\n<th>Power factor<\/th>\n<td>&gt;0.99; 0.8 leading \/lagging<\/td>\n<\/tr>\n<tr>\n<th>THDi<\/th>\n<td>&lt;3 %<\/td>\n<\/tr>\n<tr>\n<th>Keys<\/th>\n<td>ESC \/UP \/DOWN \/ENTER<\/td>\n<\/tr>\n<tr>\n<th>Status LEDs<\/th>\n<td>POWER \/OPERATION \/ALARM<\/td>\n<\/tr>\n<tr>\n<th>App roles<\/th>\n<td>Installer \/Owner<\/td>\n<\/tr>\n<tr>\n<th>Operating modes<\/th>\n<td>Self Use \/Selling First \/Off Grid \/Peak Shaving<\/td>\n<\/tr>\n<tr>\n<th>Grid charging<\/th>\n<td>Allow Grid Charging<\/td>\n<\/tr>\n<tr>\n<th>Time scheduling<\/th>\n<td>6 charging and 6 discharging windows<\/td>\n<\/tr>\n<tr>\n<th>Default maximum charge<\/th>\n<td>100 % SOC<\/td>\n<\/tr>\n<tr>\n<th>SOC setting order<\/th>\n<td>Force Charge &lt;Over-discharge &lt;Recovery<\/td>\n<\/tr>\n<tr>\n<th>Smart port \u2014 function selection<\/th>\n<td>Genset input \/AC coupled \/Smart load output<\/td>\n<\/tr>\n<tr>\n<th>PV conductors<\/th>\n<td>4\u20136 mm\u00b2; recommended 4 mm\u00b2<\/td>\n<\/tr>\n<tr>\n<th>PV stripping<\/th>\n<td>7 \u00b10.5 mm<\/td>\n<\/tr>\n<tr>\n<th>Ingress protection<\/th>\n<td>IP66<\/td>\n<\/tr>\n<tr>\n<th>Operating temperature<\/th>\n<td>\u221225\u2026+60 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th>Operating humidity<\/th>\n<td>0\u2013100 % RH<\/td>\n<\/tr>\n<tr>\n<th>Estimated delivery<\/th>\n<td>2\u20133 days<\/td>\n<\/tr>\n<tr>\n<th>Bluetooth<\/th>\n<td>BDR \/EDR \/BLE; 2.402\u20132.480 GHz; 8 dBm<\/td>\n<\/tr>\n<tr>\n<th>App sections<\/th>\n<td>Home \/Info \/Alarm \/Settings<\/td>\n<\/tr>\n<tr>\n<th>Operating information<\/th>\n<td>PV \/Battery \/Grid \/Load \/Inverter; SOC \/SOH; energy history and generator yield<\/td>\n<\/tr>\n<tr>\n<th>Diagnostics<\/th>\n<td>Current and historical alarms<\/td>\n<\/tr>\n<tr>\n<th>Initial settings<\/th>\n<td>Time, CT\/meter, grid code, operating mode and battery banks<\/td>\n<\/tr>\n<tr>\n<th>Over-discharge SOC<\/th>\n<td>5\u201340 %; default 20 %<\/td>\n<\/tr>\n<tr>\n<th>Force-charge SOC<\/th>\n<td>From 4% to selected over-discharge SOC<\/td>\n<\/tr>\n<tr>\n<th>Discharge recovery<\/th>\n<td>1\u201320 percentage points above over-discharge SOC<\/td>\n<\/tr>\n<tr>\n<th>Generator \u2014 start \/stop SOC<\/th>\n<td>1\u201395 % \/35\u2013100 %<\/td>\n<\/tr>\n<tr>\n<th>AC coupling \u2014 start \/stop SOC<\/th>\n<td>1\u201395 % \/35\u2013100 %<\/td>\n<\/tr>\n<tr>\n<th>Maximum AC apparent output<\/th>\n<td>100000 VA<\/td>\n<\/tr>\n<tr>\n<th>Rated backup output<\/th>\n<td>100000 W<\/td>\n<\/tr>\n<tr>\n<th>Backup peak 10 seconds<\/th>\n<td>160.0 kVA \/10 s<\/td>\n<\/tr>\n<tr>\n<th>Backup peak 200 ms<\/th>\n<td>200 kVA \/200 ms<\/td>\n<\/tr>\n<tr>\n<th>Single-unit transfer<\/th>\n<td>&lt;10 ms<\/td>\n<\/tr>\n<tr>\n<th>Parallel transfer up to 6 units<\/th>\n<td>&lt;20 ms<\/td>\n<\/tr>\n<tr>\n<th>Maximum power per phase<\/th>\n<td>33.33 kW<\/td>\n<\/tr>\n<tr>\n<th>Phase imbalance<\/th>\n<td>100 %<\/td>\n<\/tr>\n<tr>\n<th>THDv linear load<\/th>\n<td>&lt;3 %<\/td>\n<\/tr>\n<tr>\n<th>MPPT count<\/th>\n<td>10<\/td>\n<\/tr>\n<tr>\n<th>String count<\/th>\n<td>20<\/td>\n<\/tr>\n<tr>\n<th>Strings per MPPT<\/th>\n<td>2<\/td>\n<\/tr>\n<tr>\n<th>Input current per MPPT<\/th>\n<td>42 A<\/td>\n<\/tr>\n<tr>\n<th>Current per string<\/th>\n<td>21 A<\/td>\n<\/tr>\n<tr>\n<th>Short-circuit current per MPPT<\/th>\n<td>60 A<\/td>\n<\/tr>\n<tr>\n<th>Recommended PV array rating<\/th>\n<td>200 kWp<\/td>\n<\/tr>\n<tr>\n<th>Maximum usable PV power<\/th>\n<td>200 kW<\/td>\n<\/tr>\n<tr>\n<th>Maximum DC voltage<\/th>\n<td>1000 V<\/td>\n<\/tr>\n<tr>\n<th>Rated DC voltage<\/th>\n<td>600 V<\/td>\n<\/tr>\n<tr>\n<th>Start-up voltage<\/th>\n<td>180 V<\/td>\n<\/tr>\n<tr>\n<th>MPPT range<\/th>\n<td>150\u2013950 V<\/td>\n<\/tr>\n<tr>\n<th>DC switches<\/th>\n<td>2; PV1\u2013PV10 and PV11\u2013PV20<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<th>Battery type<\/th>\n<td>Compatible HV Li-ion system with BMS<\/td>\n<\/tr>\n<tr>\n<th>Battery voltage<\/th>\n<td>300\u2013950 V<\/td>\n<\/tr>\n<tr>\n<th>Battery ports \/BMS count<\/th>\n<td>2 \/2<\/td>\n<\/tr>\n<tr>\n<th>Maximum battery current per port<\/th>\n<td>100 A<\/td>\n<\/tr>\n<tr>\n<th>Combined battery current<\/th>\n<td>Up to 200 A according to wiring and BMS<\/td>\n<\/tr>\n<tr>\n<th>Battery communication<\/th>\n<td>CAN<\/td>\n<\/tr>\n<tr>\n<th>BMS CAN RJ45<\/th>\n<td>4 CAN-H \/5 CAN-L<\/td>\n<\/tr>\n<tr>\n<th>One battery \u2014 one port<\/th>\n<td>BAT1 +BMS1<\/td>\n<\/tr>\n<tr>\n<th>One battery \u2014 two ports<\/th>\n<td>BAT1 +BAT2, BMS1 according to diagram<\/td>\n<\/tr>\n<tr>\n<th>Two independent batteries<\/th>\n<td>Each with its own BAT and BMS port<\/td>\n<\/tr>\n<tr>\n<th>Bank settings<\/th>\n<td>Count 1\u20132, model, connection method, current and SOC<\/td>\n<\/tr>\n<tr>\n<th>Battery operating point 300 V<\/th>\n<td>90 A \/27 kW<\/td>\n<\/tr>\n<tr>\n<th>Battery operating point 400 V<\/th>\n<td>100 A \/40 kW<\/td>\n<\/tr>\n<tr>\n<th>Battery operating point 500 V<\/th>\n<td>100 A \/50 kW<\/td>\n<\/tr>\n<tr>\n<th>Battery operating point 600 V<\/th>\n<td>100 A \/60 kW<\/td>\n<\/tr>\n<tr>\n<th>Family battery-port limit<\/th>\n<td>65 kW<\/td>\n<\/tr>\n<tr>\n<th>Determining actual battery power<\/th>\n<td>U\u00d7I, BMS, port and specific model limits<\/td>\n<\/tr>\n<tr>\n<th>Rated AC current at 380\/400 V<\/th>\n<td>151.9 \/144.3 A<\/td>\n<\/tr>\n<tr>\n<th>Maximum grid input current<\/th>\n<td>250 A<\/td>\n<\/tr>\n<tr>\n<th>Grid voltage range<\/th>\n<td>304\u2013460 V<\/td>\n<\/tr>\n<tr>\n<th>Generator \u2014 maximum input power<\/th>\n<td>100 kW<\/td>\n<\/tr>\n<tr>\n<th>Generator \u2014 current at 380\/400 V<\/th>\n<td>151.9 \/144.3 A<\/td>\n<\/tr>\n<tr>\n<th>Maximum efficiency<\/th>\n<td>97.5 %<\/td>\n<\/tr>\n<tr>\n<th>European efficiency<\/th>\n<td>97.1 %<\/td>\n<\/tr>\n<tr>\n<th>PV \u2192battery efficiency<\/th>\n<td>98.2 %<\/td>\n<\/tr>\n<tr>\n<th>AC \u2192battery efficiency<\/th>\n<td>97.0 %<\/td>\n<\/tr>\n<tr>\n<th>Battery \u2192AC efficiency<\/th>\n<td>97.0 %<\/td>\n<\/tr>\n<tr>\n<th>Self-consumption<\/th>\n<td>&lt;45 W<\/td>\n<\/tr>\n<tr>\n<th>User interface<\/th>\n<td>7.0\u2033 LCD \/Bluetooth \/SolisCloud<\/td>\n<\/tr>\n<tr>\n<th>Battery reserve<\/th>\n<td>Batt saving; default SOC 80%<\/td>\n<\/tr>\n<tr>\n<th>Demand control<\/th>\n<td>Grid Peak Shaving according to mode, SOC and system capability<\/td>\n<\/tr>\n<tr>\n<th>Parallel-system export calibration<\/th>\n<td>0.5% total capacity according to manual<\/td>\n<\/tr>\n<tr>\n<th>Standard meter<\/th>\n<td>Eastron SDM630MCT V2<\/td>\n<\/tr>\n<tr>\n<th>Standard CTs<\/th>\n<td>3 \u00d7Acrel AKH-0.66-K-80\u00d740-600A; 600 A \/5 A<\/td>\n<\/tr>\n<tr>\n<th>CT ratio<\/th>\n<td>120<\/td>\n<\/tr>\n<tr>\n<th>CT cable<\/th>\n<td>5 m \/0.8 mm\u00b2<\/td>\n<\/tr>\n<tr>\n<th>CT orientation<\/th>\n<td>P1 towards inverter, P2 towards grid<\/td>\n<\/tr>\n<tr>\n<th>CT terminals L1<\/th>\n<td>1 black (+), 2 purple (\u2212)<\/td>\n<\/tr>\n<tr>\n<th>CT terminals L2<\/th>\n<td>3 orange (+), 4 blue (\u2212)<\/td>\n<\/tr>\n<tr>\n<th>CT terminals L3<\/th>\n<td>5 yellow (+), 6 green (\u2212)<\/td>\n<\/tr>\n<tr>\n<th>METER terminals<\/th>\n<td>21 A \/22 B<\/td>\n<\/tr>\n<tr>\n<th>RS485 for Solis PV inverter<\/th>\n<td>19 A \/20 B<\/td>\n<\/tr>\n<tr>\n<th>EMS protocol \/RJ45<\/th>\n<td>Modbus RTU; 5 A \/4 B<\/td>\n<\/tr>\n<tr>\n<th>ETH interface<\/th>\n<td>TCP\/IP; 1 TX+ \/2 TX\u2212 \/3 RX+ \/6 RX\u2212<\/td>\n<\/tr>\n<tr>\n<th>Communication glands<\/th>\n<td>COM1\/COM2: 7 holes, 6 mm<\/td>\n<\/tr>\n<tr>\n<th>GEN DO1<\/th>\n<td>11\/12; generator start at Grid or Smart<\/td>\n<\/tr>\n<tr>\n<th>GEN DO2<\/th>\n<td>13\/14; generator start at Smart<\/td>\n<\/tr>\n<tr>\n<th>GEN DI1<\/th>\n<td>5\/6; ATS voltage-free contact<\/td>\n<\/tr>\n<tr>\n<th>GEN DI2<\/th>\n<td>7\/8; external 5\/12 VDC status signal<\/td>\n<\/tr>\n<tr>\n<th>RSD \/EPO<\/th>\n<td>External shutdown through designated terminals according to diagram<\/td>\n<\/tr>\n<tr>\n<th>AC C<\/th>\n<td>External AC-coupled-source relay control<\/td>\n<\/tr>\n<tr>\n<th>SG-DO<\/th>\n<td>Heat-pump interface<\/td>\n<\/tr>\n<tr>\n<th>AC coupling \u2014 three-phase PV at Smart<\/th>\n<td>PV inverter rated output up to hybrid rating<\/td>\n<\/tr>\n<tr>\n<th>Dual AC-coupling metering<\/th>\n<td>Meter 001 grid, 002 PV source<\/td>\n<\/tr>\n<tr>\n<th>Parallel unit count<\/th>\n<td>Up to 6 basic layout; 7\u201310 with external STS according to project<\/td>\n<\/tr>\n<tr>\n<th>Parallel models<\/th>\n<td>Matching model and current ARM\/DSP firmware<\/td>\n<\/tr>\n<tr>\n<th>Parallel communication<\/th>\n<td>P-A \/P-B; shielded CAT5<\/td>\n<\/tr>\n<tr>\n<th>Total parallel connection length<\/th>\n<td>&lt;60 m<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<th>System addresses<\/th>\n<td>Primary 1; Secondary 2, 3\u2026<\/td>\n<\/tr>\n<tr>\n<th>DIP termination<\/th>\n<td>Endpoint units ON, intermediate OFF<\/td>\n<\/tr>\n<tr>\n<th>Parallel-system batteries<\/th>\n<td>Assigned to individual inverters with separate battery settings<\/td>\n<\/tr>\n<tr>\n<th>AC length difference above 2 units<\/th>\n<td>\u226410 %<\/td>\n<\/tr>\n<tr>\n<th>Dimensions W \u00d7H \u00d7D<\/th>\n<td>1174 \u00d7814 \u00d7400 mm<\/td>\n<\/tr>\n<tr>\n<th>Weight<\/th>\n<td>170 kg<\/td>\n<\/tr>\n<tr>\n<th>Altitude<\/th>\n<td>3000 m<\/td>\n<\/tr>\n<tr>\n<th>Cooling<\/th>\n<td>Intelligent redundant fan cooling<\/td>\n<\/tr>\n<tr>\n<th>Typical noise<\/th>\n<td>&lt;70 dB(A)<\/td>\n<\/tr>\n<tr>\n<th>Surge protection<\/th>\n<td>DC Type II \/AC Type II<\/td>\n<\/tr>\n<tr>\n<th>AFCI 2.0<\/th>\n<td>Included in this configuration<\/td>\n<\/tr>\n<tr>\n<th>Mounting<\/th>\n<td>Fixed wall or post structure; vertical up to 15\u00b0 rearward<\/td>\n<\/tr>\n<tr>\n<th>Mounting clearances<\/th>\n<td>Top 200, sides 450, bottom 400, front 1000 mm<\/td>\n<\/tr>\n<tr>\n<th>Structure design load<\/th>\n<td>\u2265680 kg<\/td>\n<\/tr>\n<tr>\n<th>Battery conductors<\/th>\n<td>Cu 25\u201335 mm\u00b2; max.35 mm\u00b2<\/td>\n<\/tr>\n<tr>\n<th>Battery terminals<\/th>\n<td>M6; 4.5\u20135.0 Nm<\/td>\n<\/tr>\n<tr>\n<th>Backup conductors \/terminals<\/th>\n<td>Cu 70 mm\u00b2; max.95 mm\u00b2; M8; 10\u201312 Nm<\/td>\n<\/tr>\n<tr>\n<th>Smart conductors \/terminals<\/th>\n<td>Cu 70 mm\u00b2; max.120 mm\u00b2; M12; 20\u201330 Nm<\/td>\n<\/tr>\n<tr>\n<th>Grid conductors \/terminals<\/th>\n<td>Cu 95 mm\u00b2; max.150 mm\u00b2; M12; 20\u201330 Nm<\/td>\n<\/tr>\n<tr>\n<th>PE conductors \/terminals<\/th>\n<td>Cu 50\u201370 mm\u00b2; M10; 10\u201312 Nm<\/td>\n<\/tr>\n<tr>\n<th>Battery \/AC stripping<\/th>\n<td>OT crimp-area length +2\u20133 mm<\/td>\n<\/tr>\n<tr>\n<th>Reference Grid protection<\/th>\n<td>\u2265315 A \/\u2265400 VAC according to design<\/td>\n<\/tr>\n<tr>\n<th>Reference Backup \/Smart protection<\/th>\n<td>&gt;225 A \/\u2265400 VAC according to design<\/td>\n<\/tr>\n<tr>\n<th>Package \u2014 main items<\/th>\n<td>Inverter, backplate, quick guide, 4 handles, 2 lifting eyes<\/td>\n<\/tr>\n<tr>\n<th>Package \u2014 metering and monitoring<\/th>\n<td>Eastron meter, 3 CTs, CT cable, S2-WL-ST logger<\/td>\n<\/tr>\n<tr>\n<th>Package \u2014 connectors<\/th>\n<td>20 \u00d7PV; 10 \u00d7RJ45; 1 \u00d7shielded RJ45 5 m<\/td>\n<\/tr>\n<tr>\n<th>Maximum Backup AC passthrough<\/th>\n<td>151.9 \/144.3 A<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2>An energy centre for business<\/h2>\n<p>Solis S6-EH3P100K10-NV-YD-H connects commercial PV, high-voltage batteries and three-phase loads at 100 kW. Operating power in kW and stored energy in kWh are designed separately: appliances determine simultaneous and starting demand, while required runtime determines battery capacity. Batterado brings modules, compatible battery system, metering and inverter together for the actual project.<\/p>\n<h2>Ten MPPTs and twenty strings<\/h2>\n<p>Ten independent trackers connect twenty strings, two per MPPT. Tracker current reaches 42 A, string current 21 A and MPPT short-circuit current 60 A. This model has 200 kW recommended PV array size and maximum usable PV input. Start-up voltage is 180 V, MPPT range 150\u2013950 V and maximum input voltage 1000 V. Two DC switches serve PV1\u2013PV10 and PV11\u2013PV20.<\/p>\n<h2>Dual HV ports and actual battery power<\/h2>\n<p>Two independent ports work with compatible 300\u2013950 V Li-ion batteries at up to 100 A per port. The single-port curve includes 300 V \/90 A \/27 kW, 400 V \/100 A \/40 kW and 600 V \/100 A \/60 kW. The family single-port limit reaches 65 kW; the manual gives 130 kW combined as an example for the 125 kW model. Design always combines actual voltage, current, BMS and the specific inverter limits. Battery selection and module count determine capacity in kWh.<\/p>\n<h2>Three battery connection arrangements<\/h2>\n<p>A single battery on one input connects to BAT1 and BMS1. A suitable battery system can connect to both power ports with shared BMS1 communication according to the diagram. Two independent batteries each have their own BAT and BMS port. HMI sets bank count, model and actual connection arrangement; current and SOC settings follow the battery. CAN communication uses pins 4 CAN-H and 5 CAN-L and must match the battery system.<\/p>\n<h2>Backup matched to power and starting demand<\/h2>\n<p>Backup delivers 100 kW rated output. Short-term output reaches 160.0 kVA for ten seconds and 200 kVA for 200 ms. A single inverter transfers from grid to backup in less than 10 ms, and a parallel system of up to six units in less than 20 ms. Maximum single-phase output is 33.33 kW according to the model table. Design distributes loads across phases and accounts for starting demand and actual battery capability.<\/p>\n<h2>Local operation and SolisCloud<\/h2>\n<p>A seven-inch LCD is complemented by ESC, UP, DOWN and ENTER buttons and POWER, OPERATION and ALARM indicators. SolisCloud through Bluetooth enables local settings with Installer and Owner roles; Wi-Fi\/LAN provides remote visibility. Home, Info, Alarm and Settings show energy flows, PV generation, grid demand, battery operation, SOC\/SOH and historical energy. Initial settings cover time, metering, grid code, operating mode and battery banks.<\/p>\n<h2>Scheduled charging and demand control<\/h2>\n<p>Self Use supplies loads first and then the battery; Selling First prioritises grid export after loads, while Off Grid supplies a designed independent system. Six charging and six discharging windows use time, current and target SOC. Allow Grid Charging enables battery replenishment from the grid. Battery reserve keeps energy for outages. Peak Shaving uses actual import and SOC settings; the resulting supply is designed around PV, battery and loads.<\/p>\n<h2>Smart port and generator integration<\/h2>\n<p>Smart port is configured as Genset input, AC coupled or Smart load output. This model accepts up to 100 kW generator input. GEN-DO1 on pins 11\/12 and GEN-DO2 on 13\/14 provide voltage-free starting signals according to the connection arrangement. GEN-DI1 on 5\/6 receives an ATS contact; GEN-DI2 on 7\/8 receives an external 5\/12 VDC adaptor status signal. Automatic control can start and stop the generator by SOC. The designated SG-DO interface serves heat-pump control according to the wiring.<\/p>\n<h2>Accurate metering and AC coupling<\/h2>\n<p>The offered configuration includes Eastron SDM630MCT V2 and Acrel 600 A\/5 A CT metering. Default CT ratio is 120, cable length 5 m, with P1 towards inverter and P2 towards grid. METER uses terminals 21 A and 22 B; the separate RS485 connection for a Solis PV inverter uses 19 A and 20 B. EMS uses Modbus RTU. AC coupling can connect a suitable three-phase PV inverter to Smart port or the grid side. Dual-meter operation uses address 001 at grid and 002 at PV; control method follows the actual system.<\/p>\n<h2>Parallel capacity by design<\/h2>\n<p>A basic parallel system connects up to six matching models through P-A\/P-B with shielded CAT5. Projects with seven to ten units use an external STS switching device according to the current manual. Primary address is 1, followed by subsequent units; endpoint DIPs are ON and intermediate DIPs OFF. Total parallel distance stays below 60 m. Batteries are assigned to individual inverters with separate battery settings. Design also covers busbars, metering and AC cable-length differences within 10% above two units.<\/p>\n<h2>IP66 and completing the installation<\/h2>\n<p>The IP66 enclosure operates from \u221225 to +60 \u00b0C. Its 170 kg weight and 1174 \u00d7814 \u00d7400 mm dimensions inform fixed wall or post structure, lifting and service access. The detailed mounting diagram specifies 200 mm above, 450 mm at sides, 400 mm below and 1000 mm in front. The package includes bracket, four handles, two lifting eyes, twenty PV connector pairs, logger, meter, CTs and a 5 m shielded RJ45 cable. Modules, compatible batteries, mounting accessories, cables and protection complete the actual project.<\/p>\n<h2>Downloads<\/h2>\n<ul>\n<li><a href=\"https:\/\/batterado.com\/wp-content\/themes\/wodatherm\/assets\/documents\/solar-projects\/solis-hv-xl-ie-datasheet-v20.pdf\">Solis HV XL80\u2013125 kW \u2014 European datasheet V2.0<\/a><\/li>\n<li><a href=\"https:\/\/batterado.com\/wp-content\/themes\/wodatherm\/assets\/documents\/solar-projects\/solis-hv-xl-manual-v11.pdf\">Solis HV XL \u2014 European manual V1.1, October 2026<\/a><\/li>\n<li><a href=\"https:\/\/batterado.com\/wp-content\/themes\/wodatherm\/assets\/documents\/products\/solis-s6-eh3p100k10-nv-yd-h-afci-en.md\">Complete product overview \u2014 Markdown<\/a><\/li>\n<\/ul>\n<section class=\"tomo-ai-search-profile\">\n<h2>AI search description<\/h2>\n<p>Solis S6-EH3P100K10-NV-YD-H AFCI 2.0 \u2014 100 kW hybrid inverter, 10 MPPTs, dual HV ports. Solis S6-EH3P100K10-NV-YD-H connects commercial PV, high-voltage batteries and three-phase loads at 100 kW. Operating power in kW and stored energy in kWh are designed separately: appliances determine simultaneous and starting demand, while required runtime determines battery capacity. Batterado brings modules, compatible battery system, metering and inverter together for the actual project. Two independent ports work with compatible 300\u2013950 V Li-ion batteries at up to 100 A per port. The single-port curve includes 300 V \/90 A \/27 kW, 400 V \/100 A \/40 kW and 600 V \/100 A \/60 kW. The family single-port limit reaches 65 kW; the manual gives 130 kW combined as an example for the 125 kW model. Design always combines actual voltage, current, BMS and the specific inverter limits. Battery selection and module count determine capacity in kWh.<\/p>\n<p>Manufacturer: Solis \/ Ginlong Technologies; Manufacturer model: S6-EH3P100K10-NV-YD-H; Device type: Three-phase hybrid inverter for PV and HV battery; Offered configuration: DC switches, Wi-Fi\/LAN, LCD, meter, DC\/AC SPD II, AFCI 2.0; Rated AC output: 100000 W; Storage capacity: In kWh according to selected battery system; Battery matching: Exact model, module count, voltage, BMS, firmware and current capability; Grid connection: 3\/N\/PE; 220\/380 V; 230\/400 V; Grid frequency: 50 \/60 Hz; Power factor: &gt;0.99; 0.8 leading \/lagging; THDi: &lt;3 %; Keys: ESC \/UP \/DOWN \/ENTER; Status LEDs: POWER \/OPERATION \/ALARM; App roles: Installer \/Owner; Operating modes: Self Use \/Selling First \/Off Grid \/Peak Shaving; Grid charging: Allow Grid Charging; Time scheduling: 6 charging and 6 discharging windows; Default maximum charge: 100 % SOC; SOC setting order: Force Charge &lt;Over-discharge &lt;Recovery; Smart port \u2014 function selection: Genset input \/AC coupled \/Smart load output; PV conductors: 4\u20136 mm\u00b2; recommended 4 mm\u00b2; PV stripping: 7 \u00b10.5 mm; Ingress protection: IP66; Operating temperature: \u221225\u2026+60 \u00b0C; Operating humidity: 0\u2013100 % RH; Estimated delivery: 2\u20133 days; Bluetooth: BDR \/EDR \/BLE; 2.402\u20132.480 GHz; 8 dBm; App sections: Home \/Info \/Alarm \/Settings; Operating information: PV \/Battery \/Grid \/Load \/Inverter; SOC \/SOH; energy history and generator yield; Diagnostics: Current and historical alarms; Initial settings: Time, CT\/meter, grid code, operating mode and battery banks; Over-discharge SOC: 5\u201340 %; default 20 %; Force-charge SOC: From 4% to selected over-discharge SOC; Discharge recovery: 1\u201320 percentage points above over-discharge SOC; Generator \u2014 start \/stop SOC: 1\u201395 % \/35\u2013100 %; AC coupling \u2014 start \/stop SOC: 1\u201395 % \/35\u2013100 %; Maximum AC apparent output: 100000 VA; Rated backup output: 100000 W; Backup peak 10 seconds: 160.0 kVA \/10 s; Backup peak 200 ms: 200 kVA \/200 ms; Single-unit transfer: &lt;10 ms; Parallel transfer up to 6 units: &lt;20 ms; Maximum power per phase: 33.33 kW; Phase imbalance: 100 %; THDv linear load: &lt;3 %; MPPT count: 10; String count: 20; Strings per MPPT: 2; Input current per MPPT: 42 A; Current per string: 21 A; Short-circuit current per MPPT: 60 A; Recommended PV array rating: 200 kWp; Maximum usable PV power: 200 kW; Maximum DC voltage: 1000 V; Rated DC voltage: 600 V; Start-up voltage: 180 V; MPPT range: 150\u2013950 V; DC switches: 2; PV1\u2013PV10 and PV11\u2013PV20; Battery type: Compatible HV Li-ion system with BMS; Battery voltage: 300\u2013950 V; Battery ports \/BMS count: 2 \/2; Maximum battery current per port: 100 A; Combined battery current: Up to 200 A according to wiring and BMS; Battery communication: CAN; BMS CAN RJ45: 4 CAN-H \/5 CAN-L; One battery \u2014 one port: BAT1 +BMS1; One battery \u2014 two ports: BAT1 +BAT2, BMS1 according to diagram; Two independent batteries: Each with its own BAT and BMS port; Bank settings: Count 1\u20132, model, connection method, current and SOC; Battery operating point 300 V: 90 A \/27 kW; Battery operating point 400 V: 100 A \/40 kW; Battery operating point 500 V: 100 A \/50 kW; Battery operating point 600 V: 100 A \/60 kW; Family battery-port limit: 65 kW; Determining actual battery power: U\u00d7I, BMS, port and specific model limits.<\/p>\n<p>Rated AC current at 380\/400 V: 151.9 \/144.3 A; Maximum grid input current: 250 A; Grid voltage range: 304\u2013460 V; Generator \u2014 maximum input power: 100 kW; Generator \u2014 current at 380\/400 V: 151.9 \/144.3 A; Maximum efficiency: 97.5 %; European efficiency: 97.1 %; PV \u2192battery efficiency: 98.2 %; AC \u2192battery efficiency: 97.0 %; Battery \u2192AC efficiency: 97.0 %; Self-consumption: &lt;45 W; User interface: 7.0\u2033 LCD \/Bluetooth \/SolisCloud; Battery reserve: Batt saving; default SOC 80%; Demand control: Grid Peak Shaving according to mode, SOC and system capability; Parallel-system export calibration: 0.5% total capacity according to manual; Standard meter: Eastron SDM630MCT V2; Standard CTs: 3 \u00d7Acrel AKH-0.66-K-80\u00d740-600A; 600 A \/5 A; CT ratio: 120; CT cable: 5 m \/0.8 mm\u00b2; CT orientation: P1 towards inverter, P2 towards grid; CT terminals L1: 1 black (+), 2 purple (\u2212); CT terminals L2: 3 orange (+), 4 blue (\u2212); CT terminals L3: 5 yellow (+), 6 green (\u2212); METER terminals: 21 A \/22 B; RS485 for Solis PV inverter: 19 A \/20 B; EMS protocol \/RJ45: Modbus RTU; 5 A \/4 B; ETH interface: TCP\/IP; 1 TX+ \/2 TX\u2212 \/3 RX+ \/6 RX\u2212; Communication glands: COM1\/COM2: 7 holes, 6 mm; GEN DO1: 11\/12; generator start at Grid or Smart; GEN DO2: 13\/14; generator start at Smart; GEN DI1: 5\/6; ATS voltage-free contact; GEN DI2: 7\/8; external 5\/12 VDC status signal; RSD \/EPO: External shutdown through designated terminals according to diagram; AC C: External AC-coupled-source relay control; SG-DO: Heat-pump interface; AC coupling \u2014 three-phase PV at Smart: PV inverter rated output up to hybrid rating; Dual AC-coupling metering: Meter 001 grid, 002 PV source; Parallel unit count: Up to 6 basic layout; 7\u201310 with external STS according to project; Parallel models: Matching model and current ARM\/DSP firmware; Parallel communication: P-A \/P-B; shielded CAT5; Total parallel connection length: &lt;60 m; System addresses: Primary 1; Secondary 2, 3\u2026; DIP termination: Endpoint units ON, intermediate OFF; Parallel-system batteries: Assigned to individual inverters with separate battery settings; AC length difference above 2 units: \u226410 %; Dimensions W \u00d7H \u00d7D: 1174 \u00d7814 \u00d7400 mm; Weight: 170 kg; Altitude: 3000 m; Cooling: Intelligent redundant fan cooling; Typical noise: &lt;70 dB(A); Surge protection: DC Type II \/AC Type II; AFCI 2.0: Included in this configuration; Mounting: Fixed wall or post structure; vertical up to 15\u00b0 rearward; Mounting clearances: Top 200, sides 450, bottom 400, front 1000 mm; Structure design load: \u2265680 kg; Battery conductors: Cu 25\u201335 mm\u00b2; max.35 mm\u00b2; Battery terminals: M6; 4.5\u20135.0 Nm; Backup conductors \/terminals: Cu 70 mm\u00b2; max.95 mm\u00b2; M8; 10\u201312 Nm; Smart conductors \/terminals: Cu 70 mm\u00b2; max.120 mm\u00b2; M12; 20\u201330 Nm; Grid conductors \/terminals: Cu 95 mm\u00b2; max.150 mm\u00b2; M12; 20\u201330 Nm; PE conductors \/terminals: Cu 50\u201370 mm\u00b2; M10; 10\u201312 Nm; Battery \/AC stripping: OT crimp-area length +2\u20133 mm; Reference Grid protection: \u2265315 A \/\u2265400 VAC according to design; Reference Backup \/Smart protection: &gt;225 A \/\u2265400 VAC according to design; Package \u2014 main items: Inverter, backplate, quick guide, 4 handles, 2 lifting eyes; Package \u2014 metering and monitoring: Eastron meter, 3 CTs, CT cable, S2-WL-ST logger; Package \u2014 connectors: 20 \u00d7PV; 10 \u00d7RJ45; 1 \u00d7shielded RJ45 5 m; Maximum Backup AC passthrough: 151.9 \/144.3 A.<\/p>\n<p><a href=\"https:\/\/batterado.com\/product\/solis-s6-eh3p100k10-nv-yd-h-afci-hybridni-stridac\/\">Batterado \u2014 SOLIS-S6-EH3P100K10-NV-YD-H-AFCI<\/a><\/p>\n<p><a href=\"https:\/\/batterado.com\/wp-content\/themes\/wodatherm\/assets\/documents\/products\/solis-s6-eh3p100k10-nv-yd-h-afci-en.md\">Markdown \u2014 SOLIS-S6-EH3P100K10-NV-YD-H-AFCI<\/a><\/p>\n<\/section>\n","protected":false},"excerpt":{"rendered":"<p>100 kW for commercial PV and battery backup. Ten MPPTs connect twenty strings, while two 300\u2013950 V HV battery ports work at up to 100 A each. 7\u2033 LCD, Wi-Fi\/LAN, meter and Smart port connect monitoring, scheduled charging and demand control.<\/p>\n","protected":false},"featured_media":59090,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[2881],"product_cat":[3088],"product_tag":[3484,3418,3412,3516,3448],"class_list":["post-59089","product","type-product","status-publish","has-post-thumbnail","product_brand-solis-storage-energy","product_cat-solar-inverters","product_tag-10-mppt","product_tag-hv-battery-inverter","product_tag-hybrid-inverter","product_tag-solis-s6-eh3p100k10-nv-yd-h-afci","product_tag-three-phase-inverter","first","onbackorder","taxable","shipping-taxable","purchasable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product\/59089","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/comments?post=59089"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/media\/59090"}],"wp:attachment":[{"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/media?parent=59089"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product_brand?post=59089"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product_cat?post=59089"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product_tag?post=59089"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}