{"id":58851,"date":"2026-11-01T05:16:50","date_gmt":"2026-11-01T03:16:50","guid":{"rendered":"https:\/\/batterado.com\/?post_type=product&#038;p=58851"},"modified":"2026-11-01T13:51:42","modified_gmt":"2026-11-01T11:51:42","slug":"solis-s6-eh3p12k-h-hybridni-stridac-lcd","status":"publish","type":"product","link":"https:\/\/batterado.com\/en\/product\/solis-s6-eh3p12k-h-hybridni-stridac-lcd\/","title":{"rendered":"Solis S6-EH3P12K-H \u2014 12 kW hybrid inverter, 4 MPPTs, 7\u2033 LCD"},"content":{"rendered":"<h2>Technical specifications<\/h2>\n<div class=\"wt-tech-grid\">\n<table>\n<tbody>\n<tr>\n<th>Manufacturer<\/th>\n<td>Solis \/ Ginlong Technologies<\/td>\n<\/tr>\n<tr>\n<th>Manufacturer model<\/th>\n<td>S6-EH3P12K-H<\/td>\n<\/tr>\n<tr>\n<th>Offered configuration<\/th>\n<td>DC switch, Wi-Fi\/LAN, 7\u2033 LCD and meter<\/td>\n<\/tr>\n<tr>\n<th>Device type<\/th>\n<td>Three-phase hybrid inverter for PV and HV battery<\/td>\n<\/tr>\n<tr>\n<th>Rated AC output<\/th>\n<td>12000 W<\/td>\n<\/tr>\n<tr>\n<th>Maximum AC apparent output<\/th>\n<td>12000 VA<\/td>\n<\/tr>\n<tr>\n<th>Rated backup output<\/th>\n<td>12000 W<\/td>\n<\/tr>\n<tr>\n<th>Peak backup output \/ duration<\/th>\n<td>19200 VA \/10 s<\/td>\n<\/tr>\n<tr>\n<th>Single-unit transfer<\/th>\n<td>&lt;10 ms<\/td>\n<\/tr>\n<tr>\n<th>Output per phase<\/th>\n<td>4800 W<\/td>\n<\/tr>\n<tr>\n<th>MPPT \/string count<\/th>\n<td>4 \/4<\/td>\n<\/tr>\n<tr>\n<th>Input current per MPPT<\/th>\n<td>20 A<\/td>\n<\/tr>\n<tr>\n<th>Short-circuit current per MPPT<\/th>\n<td>30 A<\/td>\n<\/tr>\n<tr>\n<th>Recommended PV array rating<\/th>\n<td>24 kWp<\/td>\n<\/tr>\n<tr>\n<th>Maximum usable PV power<\/th>\n<td>19.2 kW<\/td>\n<\/tr>\n<tr>\n<th>Maximum DC voltage<\/th>\n<td>1000 V<\/td>\n<\/tr>\n<tr>\n<th>Rated DC voltage<\/th>\n<td>600 V<\/td>\n<\/tr>\n<tr>\n<th>Start-up voltage<\/th>\n<td>160 V<\/td>\n<\/tr>\n<tr>\n<th>MPPT range<\/th>\n<td>200\u2013850 V<\/td>\n<\/tr>\n<tr>\n<th>Full-load MPPT range<\/th>\n<td>300\u2013850 V<\/td>\n<\/tr>\n<tr>\n<th>Battery type<\/th>\n<td>Compatible HV Li-ion system with BMS<\/td>\n<\/tr>\n<tr>\n<th>Battery voltage<\/th>\n<td>120\u2013800 V<\/td>\n<\/tr>\n<tr>\n<th>Maximum charge \/discharge current<\/th>\n<td>50 \/50 A<\/td>\n<\/tr>\n<tr>\n<th>Maximum charge \/discharge power<\/th>\n<td>12 \/12 kW<\/td>\n<\/tr>\n<tr>\n<th>Battery \u2014 120 V reference point<\/th>\n<td>25 A<\/td>\n<\/tr>\n<tr>\n<th>Battery \u2014 200 V reference point<\/th>\n<td>50 A<\/td>\n<\/tr>\n<tr>\n<th>Battery \u2014 full-output reference<\/th>\n<td>240 V \/50 A<\/td>\n<\/tr>\n<tr>\n<th>Battery port \/BMS port<\/th>\n<td>1 \/1<\/td>\n<\/tr>\n<tr>\n<th>Storage capacity<\/th>\n<td>In kWh according to selected battery system<\/td>\n<\/tr>\n<tr>\n<th>Battery matching<\/th>\n<td>Exact model, module count, voltage, BMS, firmware and current capability<\/td>\n<\/tr>\n<tr>\n<th>Battery communication<\/th>\n<td>CAN \/RS485<\/td>\n<\/tr>\n<tr>\n<th>Grid connection<\/th>\n<td>3\/N\/PE; 220\/380 V; 230\/400 V<\/td>\n<\/tr>\n<tr>\n<th>Grid frequency<\/th>\n<td>50 \/60 Hz<\/td>\n<\/tr>\n<tr>\n<th>Rated AC current at 380\/400 V<\/th>\n<td>18.2 \/17.3 A<\/td>\n<\/tr>\n<tr>\n<th>Maximum AC input power<\/th>\n<td>18 kW<\/td>\n<\/tr>\n<tr>\n<th>Maximum AC input current at 380\/400 V<\/th>\n<td>27.3 \/26.0 A<\/td>\n<\/tr>\n<tr>\n<th>AC input voltage<\/th>\n<td>304\u2013437 \/320\u2013460 V<\/td>\n<\/tr>\n<tr>\n<th>AC input frequency<\/th>\n<td>45\u201355 \/55\u201365 Hz<\/td>\n<\/tr>\n<tr>\n<th>Power factor<\/th>\n<td>&gt;0.99; 0.8 leading \/lagging<\/td>\n<\/tr>\n<tr>\n<th>THDi<\/th>\n<td>&lt;3 %<\/td>\n<\/tr>\n<tr>\n<th>THDv linear load<\/th>\n<td>&lt;3 %<\/td>\n<\/tr>\n<tr>\n<th>Generator \u2014 maximum input power<\/th>\n<td>12 kW<\/td>\n<\/tr>\n<tr>\n<th>Generator \u2014 current at 380\/400 V<\/th>\n<td>18.2 \/17.3 A<\/td>\n<\/tr>\n<tr>\n<th>Generator \u2014 connection<\/th>\n<td>Three-phase, GEN port or designed Grid\/ATS arrangement<\/td>\n<\/tr>\n<tr>\n<th>Maximum efficiency<\/th>\n<td>97.7 %<\/td>\n<\/tr>\n<tr>\n<th>European efficiency<\/th>\n<td>97.5 %<\/td>\n<\/tr>\n<tr>\n<th>PV \u2192battery efficiency<\/th>\n<td>98.5 %<\/td>\n<\/tr>\n<tr>\n<th>Battery \u2194AC efficiency<\/th>\n<td>97.2 %<\/td>\n<\/tr>\n<tr>\n<th>MPPT efficiency<\/th>\n<td>99.9 %<\/td>\n<\/tr>\n<tr>\n<th>User interface<\/th>\n<td>7.0\u2033 LCD \/Bluetooth \/SolisCloud APP<\/td>\n<\/tr>\n<tr>\n<th>Keys<\/th>\n<td>ESC \/UP \/DOWN \/ENTER<\/td>\n<\/tr>\n<tr>\n<th>Status LEDs<\/th>\n<td>POWER \/OPERATION \/ALARM<\/td>\n<\/tr>\n<tr>\n<th>App roles<\/th>\n<td>Installer \/Owner<\/td>\n<\/tr>\n<tr>\n<th>Operating modes<\/th>\n<td>Self Use \/Selling First \/Off Grid \/Peak Shaving<\/td>\n<\/tr>\n<tr>\n<th>Grid charging<\/th>\n<td>Allow Grid Charging<\/td>\n<\/tr>\n<tr>\n<th>Time scheduling<\/th>\n<td>6 charging and 6 discharging windows<\/td>\n<\/tr>\n<tr>\n<th>Backup reserve<\/th>\n<td>5\u201395 % SOC; default 80 %<\/td>\n<\/tr>\n<tr>\n<th>Default over-discharge \/force-charge SOC<\/th>\n<td>20 \/10 %<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<th>Default maximum charge<\/th>\n<td>100 % SOC<\/td>\n<\/tr>\n<tr>\n<th>SOC setting order<\/th>\n<td>Force Charge &lt;Over-discharge &lt;Recovery<\/td>\n<\/tr>\n<tr>\n<th>Export measurement calibration<\/th>\n<td>\u2212500\u2026+500 W; default 20 W<\/td>\n<\/tr>\n<tr>\n<th>Peak Shaving<\/th>\n<td>Pmax \/Peak SOC<\/td>\n<\/tr>\n<tr>\n<th>Battery Saving \/ECO<\/th>\n<td>Grid standby supply according to SOC and PV power<\/td>\n<\/tr>\n<tr>\n<th>Battery Wakeup<\/th>\n<td>Manual\/automatic wake-up from PV or grid according to battery<\/td>\n<\/tr>\n<tr>\n<th>Wake-up \u2014 voltage<\/th>\n<td>120\u2013600 V; default 120 V<\/td>\n<\/tr>\n<tr>\n<th>Wake-up \u2014 time<\/th>\n<td>20\u2013300 s; default 180 s<\/td>\n<\/tr>\n<tr>\n<th>Wake-up \u2014 current<\/th>\n<td>Up to 6 A according to battery<\/td>\n<\/tr>\n<tr>\n<th>Battery Healing<\/th>\n<td>Controlled recovery to selected SOC<\/td>\n<\/tr>\n<tr>\n<th>Smart port \u2014 function selection<\/th>\n<td>Genset input \/AC coupled \/Smart load output<\/td>\n<\/tr>\n<tr>\n<th>Smart load \u2014 power allocation<\/th>\n<td>Backup +Smart load \u226412 kW<\/td>\n<\/tr>\n<tr>\n<th>Smart load \u2014 control<\/th>\n<td>ON\/OFF SOC; On-grid always on; Off-grid always off<\/td>\n<\/tr>\n<tr>\n<th>AC coupling \u2014 existing PV inverter<\/th>\n<td>3-phase \u226412 kW; Freq-Watt according to design<\/td>\n<\/tr>\n<tr>\n<th>AC coupling \u2014 control<\/th>\n<td>Max Export Control; Export Power \/SOC<\/td>\n<\/tr>\n<tr>\n<th>Dual meters<\/th>\n<td>Grid 001 \/PV inverter 002<\/td>\n<\/tr>\n<tr>\n<th>Included standard meter<\/th>\n<td>Eastron SDM630MCT<\/td>\n<\/tr>\n<tr>\n<th>Standard CTs<\/th>\n<td>3 \u00d7ESCT-TA16; 120 A \/40 mA<\/td>\n<\/tr>\n<tr>\n<th>Metering above 3 parallel units<\/th>\n<td>SDM630MCT V2 +ESCT-T50; 300 A \/5 A<\/td>\n<\/tr>\n<tr>\n<th>CT orientation<\/th>\n<td>Arrow towards grid<\/td>\n<\/tr>\n<tr>\n<th>Reference CT ratio<\/th>\n<td>3000; according to actual CTs<\/td>\n<\/tr>\n<tr>\n<th>BMS CAN RJ45<\/th>\n<td>4 CAN-H \/5 CAN-L<\/td>\n<\/tr>\n<tr>\n<th>BMS RS485 RJ45<\/th>\n<td>3 B \/6 A<\/td>\n<\/tr>\n<tr>\n<th>Meter RJ45<\/th>\n<td>1 A \/2 B<\/td>\n<\/tr>\n<tr>\n<th>Eastron terminals<\/th>\n<td>13 B \/14 A<\/td>\n<\/tr>\n<tr>\n<th>External RS485 Modbus RTU<\/th>\n<td>1 A \/2 B<\/td>\n<\/tr>\n<tr>\n<th>Communication glands<\/th>\n<td>COM1 \/COM2; 6 mm<\/td>\n<\/tr>\n<tr>\n<th>Parallel system<\/th>\n<td>2\u20136 identical models, each with its own battery and BMS<\/td>\n<\/tr>\n<tr>\n<th>Parallel connection<\/th>\n<td>PAR-B \u2192PAR-A; shielded CAT5; \u22645 m<\/td>\n<\/tr>\n<tr>\n<th>Parallel-system addresses<\/th>\n<td>Master 1; Slave 2\u20136<\/td>\n<\/tr>\n<tr>\n<th>Parallel bus termination<\/th>\n<td>Both DIPs ON at first and last unit according to diagram<\/td>\n<\/tr>\n<tr>\n<th>GEN \u2014 start contact<\/th>\n<td>1 \/2; voltage-free<\/td>\n<\/tr>\n<tr>\n<th>Generator at Grid \u2014 DI signal<\/th>\n<td>5 +5\/12 VDC \/6 GND; external 220 VAC \u21925\/12 VDC converter<\/td>\n<\/tr>\n<tr>\n<th>Heat pump \u2014 signal<\/th>\n<td>SG Ready; 11 \/12<\/td>\n<\/tr>\n<tr>\n<th>Heat pump \u2014 modes<\/th>\n<td>Manual \/Smart<\/td>\n<\/tr>\n<tr>\n<th>Heat pump \u2014 default ON\/OFF SOC<\/th>\n<td>90 \/70 %<\/td>\n<\/tr>\n<tr>\n<th>Heat pump \u2014 default ON\/OFF power<\/th>\n<td>2000 \/\u2212500 W<\/td>\n<\/tr>\n<tr>\n<th>Heat pump \u2014 minimum runtime<\/th>\n<td>5\u201360 min; default 10 min; step 5 min<\/td>\n<\/tr>\n<tr>\n<th>DRM \u2014 remote shutdown<\/th>\n<td>RJ45 5 \/6; open shuts down within 5 s<\/td>\n<\/tr>\n<tr>\n<th>DRM \u2014 power steps<\/th>\n<td>S1\u2013S4: 0 \/30 \/60 \/100 %<\/td>\n<\/tr>\n<tr>\n<th>DRM mode2 \u2014 default S4 import<\/th>\n<td>4.2 kW<\/td>\n<\/tr>\n<tr>\n<th>PV conductors<\/th>\n<td>4\u20136 mm\u00b2; recommended 4 mm\u00b2<\/td>\n<\/tr>\n<tr>\n<th>PV stripping<\/th>\n<td>7 \u00b10.5 mm<\/td>\n<\/tr>\n<tr>\n<th>Recommended battery conductor<\/th>\n<td>8 AWG \/8.37 mm\u00b2<\/td>\n<\/tr>\n<tr>\n<th>Battery fuse<\/th>\n<td>1000 V \/100 A<\/td>\n<\/tr>\n<tr>\n<th>Reference battery protection<\/th>\n<td>2-pole 63 A; according to design<\/td>\n<\/tr>\n<tr>\n<th>AC Grid conductors<\/th>\n<td>6\u201310 mm\u00b2<\/td>\n<\/tr>\n<tr>\n<th>AC Backup \/GEN conductors<\/th>\n<td>4\u201310 mm\u00b2<\/td>\n<\/tr>\n<tr>\n<th>PE conductor<\/th>\n<td>10 mm\u00b2<\/td>\n<\/tr>\n<tr>\n<th>AC stripping<\/th>\n<td>13 mm<\/td>\n<\/tr>\n<tr>\n<th>AC terminals \/glands<\/th>\n<td>4\u20135 Nm<\/td>\n<\/tr>\n<tr>\n<th>External earth<\/th>\n<td>M4 \/2 Nm<\/td>\n<\/tr>\n<tr>\n<th>Reference AC protection<\/th>\n<td>4-pole 63 A; according to design<\/td>\n<\/tr>\n<tr>\n<th>Mounting<\/th>\n<td>Vertical wall mounting, up to \u00b15\u00b0<\/td>\n<\/tr>\n<tr>\n<th>Mounting clearance \/front access<\/th>\n<td>300 \/500 mm<\/td>\n<\/tr>\n<tr>\n<th>Bracket hole spacing<\/th>\n<td>289 \u00d7175 mm<\/td>\n<\/tr>\n<tr>\n<th>Dimensions W \u00d7H \u00d7D<\/th>\n<td>563 \u00d7546 \u00d7250 mm<\/td>\n<\/tr>\n<tr>\n<th>Weight<\/th>\n<td>35.2 kg<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<th>Ingress protection<\/th>\n<td>IP66<\/td>\n<\/tr>\n<tr>\n<th>Operating temperature<\/th>\n<td>\u221225\u2026+60 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th>Operating humidity<\/th>\n<td>0\u2013100 % RH<\/td>\n<\/tr>\n<tr>\n<th>Altitude<\/th>\n<td>2000 m<\/td>\n<\/tr>\n<tr>\n<th>Cooling<\/th>\n<td>Intelligent fan cooling<\/td>\n<\/tr>\n<tr>\n<th>Noise<\/th>\n<td>&lt;65 dB(A)<\/td>\n<\/tr>\n<tr>\n<th>Self-consumption<\/th>\n<td>&lt;25 W<\/td>\n<\/tr>\n<tr>\n<th>Package \u2014 fasteners<\/th>\n<td>2 \u00d7M4\u00d712; 4 \u00d7M10\u00d770<\/td>\n<\/tr>\n<tr>\n<th>Package \u2014 main parts<\/th>\n<td>Inverter, backplate, quick guide, Bluetooth antenna, logger, meter and CTs<\/td>\n<\/tr>\n<tr>\n<th>Package \u2014 communications and PV<\/th>\n<td>1 \u00d7CAN; 1 \u00d7meter cable; 6 \u00d7RJ45; 4 \u00d7PV pairs<\/td>\n<\/tr>\n<tr>\n<th>Estimated delivery<\/th>\n<td>2\u20133 days<\/td>\n<\/tr>\n<tr>\n<th>Surge and arc equipment<\/th>\n<td>According to selected family protection configuration<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2>A plant matched to your demand<\/h2>\n<p>Solis S6-EH3P12K-H combines a PV array, compatible HV battery and three-phase appliances in homes or smaller businesses. Rated 12 kW describes instantaneous conversion capability. Selected battery-system kWh, usable SOC and reserve determine stored energy. Runtime follows actual consumption and simultaneous loads. Batterado helps match modules, storage, metering and electrical equipment.<\/p>\n<h2>Four MPPTs for different roof sections<\/h2>\n<p>Four independent trackers connect four strings with up to 20 A input and 30 A short-circuit current per MPPT. Recommended PV array is 24 kWp and maximum usable input 19.2 kW. Start-up voltage is 160 V, working range 200\u2013850 V and full-load range 300\u2013850 V. Design uses actual module currents and string voltage at local minimum temperature within the 1000 V DC maximum.<\/p>\n<h2>Battery: matching voltage, power and capacity<\/h2>\n<p>The 120\u2013800 V input serves a compatible high-voltage Li-ion battery with BMS. Maximum current is 50 A and power up to 12 kW according to operating point. Manual references are 120 V at 25 A, 200 V at 50 A and 240 V at 50 A for this model\u2019s full output. Design therefore matches exact battery, module count, voltage, current limits, BMS and firmware. Required kWh follows runtime and demand. Temperature conditions are checked separately for the chosen battery.<\/p>\n<h2>Backup and appliance allocation across phases<\/h2>\n<p>Backup output provides rated 12 kW and peak 19.2 kVA for 10 seconds. A single inverter transfers from grid to backup in less than 10 ms. One phase delivers up to 4.8 kW within total output. Dedicated backup circuits use Backup and utility uses Grid. Design considers motor starting, simultaneous appliances and battery capability. Smart loads can be prioritised within a combined Backup plus Smart-load total of 12 kW.<\/p>\n<h2>Seven-inch display and SolisCloud<\/h2>\n<p>A large 7\u2033 LCD shows energy flows and operating information on the device. Four keys ESC, UP, DOWN and ENTER complement three LEDs POWER, OPERATION and ALARM. SolisCloud supports local Bluetooth setup with Installer and Owner roles and remote information through included Wi-Fi\/LAN. Initial setup covers time, meter, grid code, operating mode and battery model. HMI and app provide corresponding operating data, alarms and system settings.<\/p>\n<h2>Self-consumption, time tariffs and grid charging<\/h2>\n<p>Self Use prioritises local consumption and storage; Selling First prioritises export after supplying appliances. Off Grid supports designed independent operation. Six charging and six discharging windows schedule energy. Allow Grid Charging enables recovery at Force Charge SOC or charging when PV is insufficient during a charge window. Adjustable 5\u201395% SOC reserve keeps energy available for backup. Peak Shaving uses Pmax and target SOC according to system capability.<\/p>\n<h2>Smart port for generator, AC coupling or controlled load<\/h2>\n<p>Select the Smart-port role matching the system: Genset input, AC coupled or Smart load output. A three-phase generator up to 12 kW connects at GEN for backup loads or through a designed metered Grid\/ATS arrangement. GEN start contact 1\/2 is voltage-free; a generator at Grid uses a 5\/12 VDC status DI signal on pins 5\/6 with the matching external converter. AC coupling integrates a supported three-phase PV inverter up to 12 kW with configured Freq-Watt response. Smart load switches lower-priority demand according to SOC and selected rules.<\/p>\n<h2>Metering and exact battery communications<\/h2>\n<p>The offered metering configuration includes Eastron SDM630MCT and three ESCT-TA16 120 A\/40 mA CTs. CT arrows point towards grid; standard ratio is 3000 and custom CTs use their actual ratio. Meter RJ45 uses pin 1 A and 2 B, Eastron 14 A and 13 B. BMS CAN is 4 H and 5 L; BMS RS485 uses 3 B and 6 A. Separate external Modbus RTU uses 1 A and 2 B. Dual meters for AC coupling distinguish Grid address 001 and PV inverter 002.<\/p>\n<h2>Expansion and SG Ready heat-pump control<\/h2>\n<p>Two to six identical models connect through PAR-B and PAR-A using shielded CAT5 up to 5 m between units. Each inverter has its own battery and BMS; Master address is 1 and other units 2\u20136. Both DIPs at endpoints terminate the bus according to the original diagram. More than three units use a designed SDM630MCT V2 and ESCT-T50 300 A\/5 A metering kit. SG Ready heat pumps use contacts 11\/12 for manual or Smart control by SOC and export; default thresholds 90\/70% and 2000\/\u2212500 W complement minimum runtime 5\u201360 minutes.<\/p>\n<h2>IP66 mounting and power connections<\/h2>\n<p>The 563 \u00d7546 \u00d7250 mm enclosure weighs 35.2 kg, offers IP66 and operates from \u221225 to +60 \u00b0C. Intelligent fan cooling uses 300 mm clearance and 500 mm front service access. Wall-bracket spacing is 289 \u00d7175 mm and vertical mounting allows \u00b15\u00b0. Manual AC Grid conductors are 6\u201310 mm\u00b2, Backup\/GEN 4\u201310 mm\u00b2 and PE 10 mm\u00b2; AC terminals and glands use 4\u20135 Nm. Recommended battery conductor is 8 AWG \/8.37 mm\u00b2. Final cables, protection and earthing follow the actual project.<\/p>\n<h2>Equipment for a complete energy solution<\/h2>\n<p>The package includes inverter, backplate, two M4\u00d712 screws, four M10\u00d770 expansion bolts, four pairs of PV connectors, CAN cable, six RJ45s, Bluetooth antenna and quick guide. The offered configuration includes DC switch, Wi-Fi\/LAN, 7\u2033 LCD and meter. Selected modules, mounting accessories, compatible HV battery system and electrical equipment complete the plant. The public technical overview, original diagrams and AI search description connect individual specifications to whole-system design.<\/p>\n<h2>Downloads<\/h2>\n<ul>\n<li><a href=\"https:\/\/batterado.com\/wp-content\/themes\/wodatherm\/assets\/documents\/solar-projects\/solis-hv-lcd-datasheet-v38.pdf\">Solis LCD \u2014 datasheet V3.8<\/a><\/li>\n<li><a href=\"https:\/\/batterado.com\/wp-content\/themes\/wodatherm\/assets\/documents\/solar-projects\/solis-hv-lcd-manual-v15.pdf\">Solis LCD \u2014 European manual V1.5<\/a><\/li>\n<li><a href=\"https:\/\/batterado.com\/wp-content\/themes\/wodatherm\/assets\/documents\/products\/solis-s6-eh3p12k-h-en.md\">Complete product overview \u2014 Markdown<\/a><\/li>\n<\/ul>\n<section class=\"tomo-ai-search-profile\">\n<h2>AI search description<\/h2>\n<p>Solis S6-EH3P12K-H \u2014 12 kW hybrid inverter, 4 MPPTs, 7\u2033 LCD. Solis S6-EH3P12K-H combines a PV array, compatible HV battery and three-phase appliances in homes or smaller businesses. Rated 12 kW describes instantaneous conversion capability. Selected battery-system kWh, usable SOC and reserve determine stored energy. Runtime follows actual consumption and simultaneous loads. Batterado helps match modules, storage, metering and electrical equipment. The 120\u2013800 V input serves a compatible high-voltage Li-ion battery with BMS. Maximum current is 50 A and power up to 12 kW according to operating point. Manual references are 120 V at 25 A, 200 V at 50 A and 240 V at 50 A for this model\u2019s full output. Design therefore matches exact battery, module count, voltage, current limits, BMS and firmware. Required kWh follows runtime and demand. Temperature conditions are checked separately for the chosen battery.<\/p>\n<p>Manufacturer: Solis \/ Ginlong Technologies; Manufacturer model: S6-EH3P12K-H; Offered configuration: DC switch, Wi-Fi\/LAN, 7\u2033 LCD and meter; Device type: Three-phase hybrid inverter for PV and HV battery; Rated AC output: 12000 W; Maximum AC apparent output: 12000 VA; Rated backup output: 12000 W; Peak backup output \/ duration: 19200 VA \/10 s; Single-unit transfer: &lt;10 ms; Output per phase: 4800 W; MPPT \/string count: 4 \/4; Input current per MPPT: 20 A; Short-circuit current per MPPT: 30 A; Recommended PV array rating: 24 kWp; Maximum usable PV power: 19.2 kW; Maximum DC voltage: 1000 V; Rated DC voltage: 600 V; Start-up voltage: 160 V; MPPT range: 200\u2013850 V; Full-load MPPT range: 300\u2013850 V; Battery type: Compatible HV Li-ion system with BMS; Battery voltage: 120\u2013800 V; Maximum charge \/discharge current: 50 \/50 A; Maximum charge \/discharge power: 12 \/12 kW; Battery \u2014 120 V reference point: 25 A; Battery \u2014 200 V reference point: 50 A; Battery \u2014 full-output reference: 240 V \/50 A; Battery port \/BMS port: 1 \/1; Storage capacity: In kWh according to selected battery system; Battery matching: Exact model, module count, voltage, BMS, firmware and current capability; Battery communication: CAN \/RS485; Grid connection: 3\/N\/PE; 220\/380 V; 230\/400 V; Grid frequency: 50 \/60 Hz; Rated AC current at 380\/400 V: 18.2 \/17.3 A; Maximum AC input power: 18 kW; Maximum AC input current at 380\/400 V: 27.3 \/26.0 A; AC input voltage: 304\u2013437 \/320\u2013460 V; AC input frequency: 45\u201355 \/55\u201365 Hz; Power factor: &gt;0.99; 0.8 leading \/lagging; THDi: &lt;3 %; THDv linear load: &lt;3 %; Generator \u2014 maximum input power: 12 kW; Generator \u2014 current at 380\/400 V: 18.2 \/17.3 A; Generator \u2014 connection: Three-phase, GEN port or designed Grid\/ATS arrangement; Maximum efficiency: 97.7 %; European efficiency: 97.5 %; PV \u2192battery efficiency: 98.5 %; Battery \u2194AC efficiency: 97.2 %; MPPT efficiency: 99.9 %; User interface: 7.0\u2033 LCD \/Bluetooth \/SolisCloud APP; Keys: ESC \/UP \/DOWN \/ENTER; Status LEDs: POWER \/OPERATION \/ALARM; App roles: Installer \/Owner; Operating modes: Self Use \/Selling First \/Off Grid \/Peak Shaving; Grid charging: Allow Grid Charging; Time scheduling: 6 charging and 6 discharging windows; Backup reserve: 5\u201395 % SOC; default 80 %; Default over-discharge \/force-charge SOC: 20 \/10 %; Default maximum charge: 100 % SOC; SOC setting order: Force Charge &lt;Over-discharge &lt;Recovery; Export measurement calibration: \u2212500\u2026+500 W; default 20 W; Peak Shaving: Pmax \/Peak SOC; Battery Saving \/ECO: Grid standby supply according to SOC and PV power; Battery Wakeup: Manual\/automatic wake-up from PV or grid according to battery; Wake-up \u2014 voltage: 120\u2013600 V; default 120 V; Wake-up \u2014 time: 20\u2013300 s; default 180 s; Wake-up \u2014 current: Up to 6 A according to battery.<\/p>\n<p>Battery Healing: Controlled recovery to selected SOC; Smart port \u2014 function selection: Genset input \/AC coupled \/Smart load output; Smart load \u2014 power allocation: Backup +Smart load \u226412 kW; Smart load \u2014 control: ON\/OFF SOC; On-grid always on; Off-grid always off; AC coupling \u2014 existing PV inverter: 3-phase \u226412 kW; Freq-Watt according to design; AC coupling \u2014 control: Max Export Control; Export Power \/SOC; Dual meters: Grid 001 \/PV inverter 002; Included standard meter: Eastron SDM630MCT; Standard CTs: 3 \u00d7ESCT-TA16; 120 A \/40 mA; Metering above 3 parallel units: SDM630MCT V2 +ESCT-T50; 300 A \/5 A; CT orientation: Arrow towards grid; Reference CT ratio: 3000; according to actual CTs; BMS CAN RJ45: 4 CAN-H \/5 CAN-L; BMS RS485 RJ45: 3 B \/6 A; Meter RJ45: 1 A \/2 B; Eastron terminals: 13 B \/14 A; External RS485 Modbus RTU: 1 A \/2 B; Communication glands: COM1 \/COM2; 6 mm; Parallel system: 2\u20136 identical models, each with its own battery and BMS; Parallel connection: PAR-B \u2192PAR-A; shielded CAT5; \u22645 m; Parallel-system addresses: Master 1; Slave 2\u20136; Parallel bus termination: Both DIPs ON at first and last unit according to diagram; GEN \u2014 start contact: 1 \/2; voltage-free; Generator at Grid \u2014 DI signal: 5 +5\/12 VDC \/6 GND; external 220 VAC \u21925\/12 VDC converter; Heat pump \u2014 signal: SG Ready; 11 \/12; Heat pump \u2014 modes: Manual \/Smart; Heat pump \u2014 default ON\/OFF SOC: 90 \/70 %; Heat pump \u2014 default ON\/OFF power: 2000 \/\u2212500 W; Heat pump \u2014 minimum runtime: 5\u201360 min; default 10 min; step 5 min; DRM \u2014 remote shutdown: RJ45 5 \/6; open shuts down within 5 s; DRM \u2014 power steps: S1\u2013S4: 0 \/30 \/60 \/100 %; DRM mode2 \u2014 default S4 import: 4.2 kW; PV conductors: 4\u20136 mm\u00b2; recommended 4 mm\u00b2; PV stripping: 7 \u00b10.5 mm; Recommended battery conductor: 8 AWG \/8.37 mm\u00b2; Battery fuse: 1000 V \/100 A; Reference battery protection: 2-pole 63 A; according to design; AC Grid conductors: 6\u201310 mm\u00b2; AC Backup \/GEN conductors: 4\u201310 mm\u00b2; PE conductor: 10 mm\u00b2; AC stripping: 13 mm; AC terminals \/glands: 4\u20135 Nm; External earth: M4 \/2 Nm; Reference AC protection: 4-pole 63 A; according to design; Mounting: Vertical wall mounting, up to \u00b15\u00b0; Mounting clearance \/front access: 300 \/500 mm; Bracket hole spacing: 289 \u00d7175 mm; Dimensions W \u00d7H \u00d7D: 563 \u00d7546 \u00d7250 mm; Weight: 35.2 kg; Ingress protection: IP66; Operating temperature: \u221225\u2026+60 \u00b0C; Operating humidity: 0\u2013100 % RH; Altitude: 2000 m; Cooling: Intelligent fan cooling; Noise: &lt;65 dB(A); Self-consumption: &lt;25 W; Package \u2014 fasteners: 2 \u00d7M4\u00d712; 4 \u00d7M10\u00d770; Package \u2014 main parts: Inverter, backplate, quick guide, Bluetooth antenna, logger, meter and CTs; Package \u2014 communications and PV: 1 \u00d7CAN; 1 \u00d7meter cable; 6 \u00d7RJ45; 4 \u00d7PV pairs; Estimated delivery: 2\u20133 days; Surge and arc equipment: According to selected family protection configuration.<\/p>\n<p><a href=\"https:\/\/batterado.com\/product\/solis-s6-eh3p12k-h-hybridni-stridac-lcd\/\">Batterado \u2014 SOLIS-S6-EH3P12K-H<\/a><\/p>\n<p><a href=\"https:\/\/batterado.com\/wp-content\/themes\/wodatherm\/assets\/documents\/products\/solis-s6-eh3p12k-h-en.md\">Markdown \u2014 SOLIS-S6-EH3P12K-H<\/a><\/p>\n<\/section>\n","protected":false},"excerpt":{"rendered":"<p>12 kW for PV, self-consumption and battery backup. Four 20 A MPPTs, a 120\u2013800 V HV battery and clear 7\u2033 LCD connect generation, storage and consumption. Select the Smart port role for generator, AC coupling or managed loads according to system design. The offer includes DC switch, Wi-Fi\/LAN, 7\u2033 LCD and meter.<\/p>\n","protected":false},"featured_media":58852,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[2881],"product_cat":[3088],"product_tag":[3462,3418,3412,3502,3448],"class_list":["post-58851","product","type-product","status-publish","has-post-thumbnail","product_brand-solis-storage-energy","product_cat-solar-inverters","product_tag-4-mppt","product_tag-hv-battery-inverter","product_tag-hybrid-inverter","product_tag-solis-s6-eh3p12k-h","product_tag-three-phase-inverter","first","onbackorder","taxable","shipping-taxable","purchasable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product\/58851","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/comments?post=58851"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/media\/58852"}],"wp:attachment":[{"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/media?parent=58851"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product_brand?post=58851"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product_cat?post=58851"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product_tag?post=58851"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}