{"id":58736,"date":"2026-11-01T04:42:05","date_gmt":"2026-11-01T02:42:05","guid":{"rendered":"https:\/\/batterado.com\/?post_type=product&#038;p=58736"},"modified":"2026-11-01T13:51:41","modified_gmt":"2026-11-01T11:51:41","slug":"solis-s6-gc3p150k07-nv-nd-trifazovy-sitovy-stridac","status":"publish","type":"product","link":"https:\/\/batterado.com\/en\/product\/solis-s6-gc3p150k07-nv-nd-trifazovy-sitovy-stridac\/","title":{"rendered":"Solis S6-GC3P150K07-NV-ND PID \u2014 150 kW three-phase grid inverter, 7 MPPT, IP66"},"content":{"rendered":"<h2>Technical specifications<\/h2>\n<div class=\"wt-tech-grid\">\n<table>\n<tbody>\n<tr>\n<th>Manufacturer<\/th>\n<td>Solis \/ Ginlong Technologies<\/td>\n<\/tr>\n<tr>\n<th>Manufacturer model<\/th>\n<td>S6-GC3P150K07-NV-ND<\/td>\n<\/tr>\n<tr>\n<th>Offered configuration<\/th>\n<td>DC switch and PID<\/td>\n<\/tr>\n<tr>\n<th>Operating system<\/th>\n<td>Commercial PV plant with modules and utility grid<\/td>\n<\/tr>\n<tr>\n<th>Rated AC output<\/th>\n<td>150000 W<\/td>\n<\/tr>\n<tr>\n<th>Maximum AC output<\/th>\n<td>165000 W<\/td>\n<\/tr>\n<tr>\n<th>Maximum apparent output<\/th>\n<td>165000 VA<\/td>\n<\/tr>\n<tr>\n<th>MPPT count<\/th>\n<td>7<\/td>\n<\/tr>\n<tr>\n<th>String count<\/th>\n<td>21<\/td>\n<\/tr>\n<tr>\n<th>Strings per MPPT<\/th>\n<td>3<\/td>\n<\/tr>\n<tr>\n<th>Input current per MPPT<\/th>\n<td>54 A<\/td>\n<\/tr>\n<tr>\n<th>Short-circuit current per MPPT<\/th>\n<td>75 A<\/td>\n<\/tr>\n<tr>\n<th>Maximum DC voltage<\/th>\n<td>1100 V<\/td>\n<\/tr>\n<tr>\n<th>Rated DC voltage<\/th>\n<td>600 V<\/td>\n<\/tr>\n<tr>\n<th>Start-up voltage<\/th>\n<td>180 V<\/td>\n<\/tr>\n<tr>\n<th>MPPT range<\/th>\n<td>160\u20131000 V<\/td>\n<\/tr>\n<tr>\n<th>Rated grid voltage<\/th>\n<td>3\/N\/PE; 220\/380 V; 230\/400 V<\/td>\n<\/tr>\n<tr>\n<th>Grid frequency<\/th>\n<td>50 \/60 Hz<\/td>\n<\/tr>\n<tr>\n<th>Maximum AC current<\/th>\n<td>250.6 A<\/td>\n<\/tr>\n<tr>\n<th>Power factor<\/th>\n<td>&gt;0.99; adjustable 0.8 leading to 0.8 lagging<\/td>\n<\/tr>\n<tr>\n<th>THDi<\/th>\n<td>&lt;3 %<\/td>\n<\/tr>\n<tr>\n<th>Maximum efficiency<\/th>\n<td>98.8 %<\/td>\n<\/tr>\n<tr>\n<th>European efficiency<\/th>\n<td>98.3 %<\/td>\n<\/tr>\n<tr>\n<th>Night consumption<\/th>\n<td>&lt;2 W<\/td>\n<\/tr>\n<tr>\n<th>Dimensions W \u00d7 H \u00d7 D<\/th>\n<td>1035.5 \u00d7869 \u00d7396 mm<\/td>\n<\/tr>\n<tr>\n<th>Weight<\/th>\n<td>105 kg<\/td>\n<\/tr>\n<tr>\n<th>Rated current at 400 V \/380 V<\/th>\n<td>216.5 \/227.9 A<\/td>\n<\/tr>\n<tr>\n<th>DC polarity protection<\/th>\n<td>Integrated function<\/td>\n<\/tr>\n<tr>\n<th>Short-circuit protection<\/th>\n<td>Integrated function<\/td>\n<\/tr>\n<tr>\n<th>AC overcurrent protection<\/th>\n<td>Integrated function<\/td>\n<\/tr>\n<tr>\n<th>Grid monitoring<\/th>\n<td>Integrated function<\/td>\n<\/tr>\n<tr>\n<th>Anti-islanding protection<\/th>\n<td>Integrated function<\/td>\n<\/tr>\n<tr>\n<th>Temperature protection<\/th>\n<td>Integrated function<\/td>\n<\/tr>\n<tr>\n<th>String monitoring<\/th>\n<td>Integrated function<\/td>\n<\/tr>\n<tr>\n<th>I\/V scanning<\/th>\n<td>Integrated function<\/td>\n<\/tr>\n<tr>\n<th>Night SVG<\/th>\n<td>Integrated function<\/td>\n<\/tr>\n<tr>\n<th>DC switch<\/th>\n<td>Integrated function<\/td>\n<\/tr>\n<tr>\n<th>Surge protection<\/th>\n<td>DC Type II \/AC Type II; AC Type I optional<\/td>\n<\/tr>\n<tr>\n<th>PID recovery<\/th>\n<td>Included in offered configuration<\/td>\n<\/tr>\n<tr>\n<th>AFCI 2.0<\/th>\n<td>Optional family configuration according to design<\/td>\n<\/tr>\n<tr>\n<th>PLC communication<\/th>\n<td>Optional family configuration according to design<\/td>\n<\/tr>\n<tr>\n<th>Master-Slave control<\/th>\n<td>Optional family configuration according to design<\/td>\n<\/tr>\n<tr>\n<th>PID \u2014 operating principle<\/th>\n<td>Automatic night recovery; at DC bus &lt;50 V generates 450 V between PV\u2212 and earth with AC active<\/td>\n<\/tr>\n<tr>\n<th>AFCI \u2014 recovery<\/th>\n<td>For AFCI configuration automatically after 5 min; more than 5 faults require DC inspection and manual Clear Immediately in app<\/td>\n<\/tr>\n<tr>\n<th>Fuseless DC design<\/th>\n<td>Internal string overcurrent protection<\/td>\n<\/tr>\n<tr>\n<th>Optional additional DC protection<\/th>\n<td>1.5\u20132.4 \u00d7Impp; IEC\/EN60269-6<\/td>\n<\/tr>\n<tr>\n<th>User interface<\/th>\n<td>LED \/Bluetooth \/SolisCloud APP<\/td>\n<\/tr>\n<tr>\n<th>Application and roles<\/th>\n<td>SolisCloud Android \/iOS; Installer \/Owner<\/td>\n<\/tr>\n<tr>\n<th>Application sections<\/th>\n<td>Home \/Info \/Alarm \/Settings<\/td>\n<\/tr>\n<tr>\n<th>Displayed data<\/th>\n<td>Power and energy, PV\/AC data, serial number, firmware and grid code<\/td>\n<\/tr>\n<tr>\n<th>Diagnostics<\/th>\n<td>Alarm codes and corresponding guidance in app<\/td>\n<\/tr>\n<tr>\n<th>Settings<\/th>\n<td>On\/off, date\/time, output percentage, power factor, grid code\/protection, work mode and EPM<\/td>\n<\/tr>\n<tr>\n<th>Communication ports<\/th>\n<td>USB logger, two RS485 monitoring ports, 16-pin METER\/RSD\/ATS and DRM RJ45<\/td>\n<\/tr>\n<tr>\n<th>Remote monitoring<\/th>\n<td>SolisCloud through suitable Wi-Fi\/LAN\/4G logger according to configuration<\/td>\n<\/tr>\n<tr>\n<th>Monitoring daisy chain<\/th>\n<td>RS485 or PLC according to selected communication<\/td>\n<\/tr>\n<tr>\n<th>PLC arrangement<\/th>\n<td>PLC CCO +datalogger<\/td>\n<\/tr>\n<tr>\n<th>16-pin \u2014 PC-485-IN<\/th>\n<td>1 B \/2 A \/3 GND<\/td>\n<\/tr>\n<tr>\n<th>16-pin \u2014 PC-485-OUT<\/th>\n<td>14 B \/15 A \/16 GND<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<th>PC-485 purpose<\/th>\n<td>Dedicated primary\/secondary EPM connection, independent of monitoring<\/td>\n<\/tr>\n<tr>\n<th>16-pin \u2014 Meter-2<\/th>\n<td>4 A \/5 B<\/td>\n<\/tr>\n<tr>\n<th>16-pin \u2014 Meter<\/th>\n<td>8 A \/9 B<\/td>\n<\/tr>\n<tr>\n<th>16-pin \u2014 ATS-IN<\/th>\n<td>6 0 V \/7 5 V<\/td>\n<\/tr>\n<tr>\n<th>16-pin \u2014 RSD<\/th>\n<td>10 RSD+ \/11 RSD\u2212<\/td>\n<\/tr>\n<tr>\n<th>DRM logic control<\/th>\n<td>RJ45:5 Switch_input1 \/6 Switch_input2<\/td>\n<\/tr>\n<tr>\n<th>Logic control \u2014 response<\/th>\n<td>When enabled opening limits output to 0 W within 5 s<\/td>\n<\/tr>\n<tr>\n<th>RS485 \u2014 cable \/ torque<\/th>\n<td>0.5\u20130.75 mm\u00b2 \/0.6 Nm<\/td>\n<\/tr>\n<tr>\n<th>EPM solution 1<\/th>\n<td>Solis-EPM3-5G-PRO +Meter; \u226420<\/td>\n<\/tr>\n<tr>\n<th>EPM solution 2<\/th>\n<td>S3-Logger-EPM \/MB-S4-W4 +Meter; \u226445<\/td>\n<\/tr>\n<tr>\n<th>EPM solution 3<\/th>\n<td>G3-Gateway +Meter; \u2264105<\/td>\n<\/tr>\n<tr>\n<th>EPM solution 4<\/th>\n<td>Meter; \u226410<\/td>\n<\/tr>\n<tr>\n<th>EPM primary \/ secondary meter<\/th>\n<td>ADL400-C; menu ADL400C<\/td>\n<\/tr>\n<tr>\n<th>Meter \u2014 connection<\/th>\n<td>21 A \/22 B \u2192Meter-2 4 A \/5 B<\/td>\n<\/tr>\n<tr>\n<th>Meter CTs<\/th>\n<td>Secondary current &lt;6 A; suitable class 0.5; primary range according to system maximum current<\/td>\n<\/tr>\n<tr>\n<th>CT orientation<\/th>\n<td>P2 towards utility grid<\/td>\n<\/tr>\n<tr>\n<th>Meter \u2014 reference settings<\/th>\n<td>38400 baud; CT 400:1 for documented arrangement, ratio according to actual CTs<\/td>\n<\/tr>\n<tr>\n<th>EPM addresses<\/th>\n<td>Primary 1, secondary 2\u201310, each unique; separate from monitoring address<\/td>\n<\/tr>\n<tr>\n<th>EPM interconnection<\/th>\n<td>PC-485-OUT14\/15\/16 \u2192PC-485-IN1\/2\/3 of next device<\/td>\n<\/tr>\n<tr>\n<th>AC source modes<\/th>\n<td>AUTO \/Forced Grid \/Forced Genset \/AutoACbox<\/td>\n<\/tr>\n<tr>\n<th>EPM grid configuration<\/th>\n<td>3P-3W; optional supported 3P-4W configuration<\/td>\n<\/tr>\n<tr>\n<th>EPM control<\/th>\n<td>Minimum \/Average; Unbalance in supported 3P-4W configuration<\/td>\n<\/tr>\n<tr>\n<th>Generator \u2014 control<\/th>\n<td>AUTO for one source; AutoACbox for multiple sources, up to 8 power settings; Minimum or supported Unbalance<\/td>\n<\/tr>\n<tr>\n<th>Unbalanced control \u2014 wiring<\/th>\n<td>Supported 3P-4W variant, connected neutral and consistent phase sequence across primary\/secondary units<\/td>\n<\/tr>\n<tr>\n<th>Ingress protection<\/th>\n<td>IP66<\/td>\n<\/tr>\n<tr>\n<th>Topology<\/th>\n<td>Transformerless<\/td>\n<\/tr>\n<tr>\n<th>Cooling<\/th>\n<td>Intelligent fan cooling, redundant per manual<\/td>\n<\/tr>\n<tr>\n<th>Operating temperature<\/th>\n<td>\u221230\u2026+60 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th>Operating humidity<\/th>\n<td>0\u2013100 % RH<\/td>\n<\/tr>\n<tr>\n<th>Altitude<\/th>\n<td>4000 m<\/td>\n<\/tr>\n<tr>\n<th>Storage temperature<\/th>\n<td>\u221240\u2026+70 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th>Storage humidity<\/th>\n<td>0\u201395 % RH non-condensing<\/td>\n<\/tr>\n<tr>\n<th>Package stacking<\/th>\n<td>3<\/td>\n<\/tr>\n<tr>\n<th>Mounting position<\/th>\n<td>Vertical on firm fire-resistant structure; other arrangements per mounting diagram<\/td>\n<\/tr>\n<tr>\n<th>Mounting clearances<\/th>\n<td>700 mm above, sides and floor; 1000 mm front<\/td>\n<\/tr>\n<tr>\n<th>Multiple unit clearances<\/th>\n<td>\u2265700 mm<\/td>\n<\/tr>\n<tr>\n<th>Mounting structure design load<\/th>\n<td>At least four times unit weight, 420 kg<\/td>\n<\/tr>\n<tr>\n<th>Handling<\/th>\n<td>Four supplied handles and suitable lifting equipment for 105 kg<\/td>\n<\/tr>\n<tr>\n<th>Bracket \u2014 dimensions<\/th>\n<td>873 \u00d7515 mm<\/td>\n<\/tr>\n<tr>\n<th>Bracket \u2014 hole spacing \/ slots<\/th>\n<td>817 \u00d7414.5 mm;4 \u00d721 \u00d711 mm<\/td>\n<\/tr>\n<tr>\n<th>Anchoring \u2014 depth \/ torque<\/th>\n<td>\u22643.8 in (96.52 mm) \/30\u201335 Nm<\/td>\n<\/tr>\n<tr>\n<th>Locking screws<\/th>\n<td>M6 \u00d714 \/2\u20133 Nm<\/td>\n<\/tr>\n<tr>\n<th>Cable support from terminals<\/th>\n<td>300\u2013350 mm<\/td>\n<\/tr>\n<tr>\n<th>External earthing<\/th>\n<td>M10 \u00d720, 10\u201312 Nm; outdoor copper conductor according to design<\/td>\n<\/tr>\n<tr>\n<th>Earthing \u2014 cable table<\/th>\n<td>35\u201350 mm\u00b2, recommended 50 mm\u00b2; final sizing according to ampacity and project<\/td>\n<\/tr>\n<tr>\n<th>AC phase conductors \u2014 detailed<\/th>\n<td>70\u2013400 mm\u00b2; recommended 120 mm\u00b2<\/td>\n<\/tr>\n<tr>\n<th>AC conductors \u2014 summary table<\/th>\n<td>95\u2013400 mm\u00b2<\/td>\n<\/tr>\n<tr>\n<th>AC conduit diameter<\/th>\n<td>30\u201375 mm<\/td>\n<\/tr>\n<tr>\n<th>Reference AC cable length<\/th>\n<td>140 m<\/td>\n<\/tr>\n<tr>\n<th>AC phase terminals<\/th>\n<td>M12 \/20\u201330 Nm<\/td>\n<\/tr>\n<tr>\n<th>AC neutral terminal<\/th>\n<td>M12 \/20\u201330 Nm; M6 \/5\u20137 Nm<\/td>\n<\/tr>\n<tr>\n<th>AC PE terminal<\/th>\n<td>M10 \/12\u201316 Nm<\/td>\n<\/tr>\n<tr>\n<th>AC stripping<\/th>\n<td>Sheath 200 mm; S2=S1+2\u20133 mm<\/td>\n<\/tr>\n<tr>\n<th>Aluminium AC conductors<\/th>\n<td>Cu\/Al bimetal lugs according to cable and design<\/td>\n<\/tr>\n<tr>\n<th>Recommended AC breaker<\/th>\n<td>300 A; IEC\/EN60947-3<\/td>\n<\/tr>\n<tr>\n<th>DC conductors<\/th>\n<td>PV1-F Cu 4\u20136 mm\u00b2, recommended 4 mm\u00b2; \u00d85.5\u20139 mm<\/td>\n<\/tr>\n<tr>\n<th>DC connectors \/ stripping \/ torque<\/th>\n<td>MC4 \/7 mm \/3\u20134 Nm<\/td>\n<\/tr>\n<tr>\n<th>Large cable grommets<\/th>\n<td>30\u201340 \/50\u201355 \/60\u201365 \/70\u201375 mm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<th>Small cable grommets<\/th>\n<td>18\u201322 \/28\u201332 mm<\/td>\n<\/tr>\n<tr>\n<th>Vent valve<\/th>\n<td>STG-4150HA \/3.5\u20134 Nm<\/td>\n<\/tr>\n<tr>\n<th>Fan servicing \u2014 space<\/th>\n<td>600 mm for module withdrawal<\/td>\n<\/tr>\n<tr>\n<th>Package \u2014 inverter \/ bracket \/ manual<\/th>\n<td>1 \/1 \/1<\/td>\n<\/tr>\n<tr>\n<th>Package \u2014 screws<\/th>\n<td>2 \u00d7M6 \u00d714;4 \u00d7M10 \u00d740 +nuts and washers<\/td>\n<\/tr>\n<tr>\n<th>Package \u2014 DC \/ 2-pin \/ RJ45<\/th>\n<td>21 \/2 \/1<\/td>\n<\/tr>\n<tr>\n<th>Package \u2014 handles \/16-pin COM<\/th>\n<td>4 \/1<\/td>\n<\/tr>\n<tr>\n<th>Plant components<\/th>\n<td>Modules, mounting accessories, cables and protection; meter, CTs, logger, EPM or AC source box according to design<\/td>\n<\/tr>\n<tr>\n<th>Grid standards<\/th>\n<td>G99; IEC61727; EN50549-1\/2; VDE4110<\/td>\n<\/tr>\n<tr>\n<th>Safety<\/th>\n<td>IEC\/EN62109-1\/-2; IEC60947-2<\/td>\n<\/tr>\n<tr>\n<th>EMC<\/th>\n<td>IEC\/EN61000-6-2\/-4<\/td>\n<\/tr>\n<tr>\n<th>Estimated delivery<\/th>\n<td>2\u20133 days<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2>Generation for commercial demand<\/h2>\n<p>Rated 150 kW describes instantaneous conversion power, while kWh generation depends on sunlight, orientation and array size. The plant combines PV modules, inverter, utility grid and electrical equipment selected by design. Suitable metering and selected EPM manage local consumption and grid export. Any storage uses a separately designed compatible battery system with an appropriate converter.<\/p>\n<h2>Seven MPPTs for 21 strings<\/h2>\n<p>Each of seven independent trackers connects three strings. MPPT input current is up to 54 A, short-circuit 75 A. Start-up is 180 V, MPPT range 160\u20131000 V, rated DC 600 V and maximum 1100 V. Design uses actual module currents and string voltage at local minimum temperature. Strings on the same tracker use matching voltage and orientation. Fuseless construction includes internal overcurrent protection.<\/p>\n<h2>Output and efficiency<\/h2>\n<p>Rated AC output is 150000 W, maximum 165000 W and maximum apparent output 165000 VA. Rated current is 216.5 A at 400 V and 227.9 A at 380 V; maximum current 250.6 A. 3\/N\/PE grid connection operates at 220\/380 or 230\/400 V and 50\/60 Hz. Maximum efficiency is 98.8%, European 98.3%, THDi below 3%. Adjustable power factor and night SVG support the designed grid connection.<\/p>\n<h2>Bluetooth and SolisCloud<\/h2>\n<p>SolisCloud for Android or iOS provides local Bluetooth connection with Installer and Owner roles. Home shows power, energy and PV\/AC data; Info shows serial number, firmware and grid code. Alarm provides codes and corresponding guidance. Settings control on\/off, time, output percentage, power factor, grid protection, work mode and EPM. Suitable Wi-Fi, LAN or 4G Solis loggers provide remote monitoring.<\/p>\n<h2>Separate monitoring and EPM communication<\/h2>\n<p>Two separate RS485 monitoring ports serve device daisy chaining. The selected route uses RS485 or PLC with PLC CCO and logger. The 16-pin METER\/RSD\/ATS connector serves metering, RSD, ATS and dedicated primary\/secondary EPM PC-485. PC-485-IN uses 1B\/2A\/3GND and OUT 14B\/15A\/16GND. Monitoring remains independent. Exact remaining pin assignments and original diagrams appear in the technical overview and gallery.<\/p>\n<h2>Four export-management arrangements<\/h2>\n<p>The manual describes optional EPM arrangements for different plant sizes. Solis-EPM3-5G-PRO with meter controls up to 20 units. S3-Logger-EPM or MB-S4-W4 with meter handles up to 45, G3-Gateway with meter up to 105. A dedicated primary\/secondary solution with meter supports up to 10 inverters. Each uses specific accessories, a matching communication route and project settings. Control accuracy follows the selected metering and control arrangement.<\/p>\n<h2>Metering and primary\/secondary system<\/h2>\n<p>For up to ten inverters, ADL400-C connects to the primary, 21A\/22B to Meter-2 4A\/5B. CTs match maximum system current and point P2 towards grid; the manual specifies secondary current below 6 A and documented 38400-baud settings. Set ratio for actual CTs. Primary address is 1, secondary 2\u201310, each unique. Optional 3P-4W with connected neutral and consistent phase sequence enables corresponding Unbalance control.<\/p>\n<h2>Grid, generator and selected equipment<\/h2>\n<p>This offer includes DC switch and PID. Supported EPM configurations select AUTO, Forced Grid, Forced Genset or AutoACbox. One generator uses AUTO; multiple sources use a suitable AC source box and up to eight power settings. Minimum, Average and any Unbalance modes match source type and wiring. Separate DRM contact RJ45 5\/6, when enabled, allows an open contact to limit output to 0 W within 5 s.<\/p>\n<h2>Construction and mounting<\/h2>\n<p>The 1035.5 \u00d7869 \u00d7396 mm enclosure weighs 105 kg. IP66 and intelligent fan cooling support suitable industrial indoor or outdoor locations, \u221230 to +60 \u00b0C, 0\u2013100% humidity and altitude up to 4000 m. A firm fire-resistant structure provides airflow, suitable sun\/weather shelter and at least 420 kg design load. The manual specifies 700 mm above, sides and floor, and 1000 mm front. Four supplied handles and suitable lifting equipment aid handling.<\/p>\n<h2>AC\/DC connection and protection<\/h2>\n<p>DC uses PV1-F copper 4\u20136 mm\u00b2, MC4 and 3\u20134 Nm torque. The detailed AC table gives 70\u2013400 mm\u00b2 with 120 mm\u00b2 recommended; the summary table gives 95\u2013400 mm\u00b2. Final cables and earthing follow project design and ampacity. The current AC diagram specifies M12 phases at 20\u201330 Nm, M12 or M6 neutral, and M10 PE at 12\u201316 Nm. Recommended AC protection is 300 A. DC\/AC Type II surge, grid and thermal protection complement nighttime PID recovery.<\/p>\n<h2>Equipment for the complete plant<\/h2>\n<p>The package includes inverter, bracket, two M6\u00d714 screws, four M10\u00d740 bolts with nuts\/washers, 21 DC connectors, two 2-pin ports, one RJ45, four handles, one 16-pin COM and manual. Modules, mounting accessories, cables, protection and suitable metering, logger or EPM follow system design and offered configuration. Batterado helps match suitable components. Storage conditions are \u221240 to +70 \u00b0C, 0\u201395% non-condensing humidity and up to three packaged units high.<\/p>\n<h2>Downloads<\/h2>\n<ul>\n<li><a href=\"https:\/\/batterado.com\/wp-content\/themes\/wodatherm\/assets\/documents\/solar-projects\/solis-s6-gc150-datasheet-v19.pdf\">Solis S6-GC3P150K \u2014 datasheet V1.9<\/a><\/li>\n<li><a href=\"https:\/\/batterado.com\/wp-content\/themes\/wodatherm\/assets\/documents\/solar-projects\/solis-s6-gc150-manual-v10.pdf\">Solis S6-GC150K \u2014 European manual V1.0<\/a><\/li>\n<li><a href=\"https:\/\/batterado.com\/wp-content\/themes\/wodatherm\/assets\/documents\/products\/solis-s6-gc3p150k07-nv-nd-en.md\">Complete product overview \u2014 Markdown<\/a><\/li>\n<\/ul>\n<section class=\"tomo-ai-search-profile\">\n<h2>AI search description<\/h2>\n<p>150 kW for large commercial PV with seven MPPTs, 21 strings and up to 54 A per tracker. Solis S6-GC3P150K07-NV-ND provides maximum AC output 165 kW, up to 98.8% efficiency and clear local Bluetooth control through SolisCloud. Its 105 kg IP66 enclosure connects a high-output PV array with a three-phase grid. String monitoring, I\/V scanning and thermal protection support plant operation. This offer includes DC switch and PID. Rated 150 kW describes instantaneous conversion power, while kWh generation depends on sunlight, orientation and array size. The plant combines PV modules, inverter, utility grid and electrical equipment selected by design. Suitable metering and selected EPM manage local consumption and grid export. Any storage uses a separately designed compatible battery system with an appropriate converter. The package includes inverter, bracket, two M6\u00d714 screws, four M10\u00d740 bolts with nuts\/washers, 21 DC connectors, two 2-pin ports, one RJ45, four handles, one 16-pin COM and manual. Modules, mounting accessories, cables, protection and suitable metering, logger or EPM follow system design and offered configuration. Batterado helps match suitable components. Storage conditions are \u221240 to +70 \u00b0C, 0\u201395% non-condensing humidity and up to three packaged units high.<\/p>\n<p>Manufacturer: Solis \/ Ginlong Technologies; Manufacturer model: S6-GC3P150K07-NV-ND; Offered configuration: DC switch and PID; Operating system: Commercial PV plant with modules and utility grid; Rated AC output: 150000 W; Maximum AC output: 165000 W; Maximum apparent output: 165000 VA; MPPT count: 7; String count: 21; Strings per MPPT: 3; Input current per MPPT: 54 A; Short-circuit current per MPPT: 75 A; Maximum DC voltage: 1100 V; Rated DC voltage: 600 V; Start-up voltage: 180 V; MPPT range: 160\u20131000 V; Rated grid voltage: 3\/N\/PE; 220\/380 V; 230\/400 V; Grid frequency: 50 \/60 Hz; Maximum AC current: 250.6 A; Power factor: &gt;0.99; adjustable 0.8 leading to 0.8 lagging; THDi: &lt;3 %; Maximum efficiency: 98.8 %; European efficiency: 98.3 %; Night consumption: &lt;2 W; Dimensions W \u00d7 H \u00d7 D: 1035.5 \u00d7869 \u00d7396 mm; Weight: 105 kg; Rated current at 400 V \/380 V: 216.5 \/227.9 A; DC polarity protection: Integrated function; Short-circuit protection: Integrated function; AC overcurrent protection: Integrated function; Grid monitoring: Integrated function; Anti-islanding protection: Integrated function; Temperature protection: Integrated function; String monitoring: Integrated function; I\/V scanning: Integrated function; Night SVG: Integrated function; DC switch: Integrated function; Surge protection: DC Type II \/AC Type II; AC Type I optional; PID recovery: Included in offered configuration; AFCI 2.0: Optional family configuration according to design; PLC communication: Optional family configuration according to design; Master-Slave control: Optional family configuration according to design; PID \u2014 operating principle: Automatic night recovery; at DC bus &lt;50 V generates 450 V between PV\u2212 and earth with AC active; AFCI \u2014 recovery: For AFCI configuration automatically after 5 min; more than 5 faults require DC inspection and manual Clear Immediately in app; Fuseless DC design: Internal string overcurrent protection; Optional additional DC protection: 1.5\u20132.4 \u00d7Impp; IEC\/EN60269-6; User interface: LED \/Bluetooth \/SolisCloud APP; Application and roles: SolisCloud Android \/iOS; Installer \/Owner; Application sections: Home \/Info \/Alarm \/Settings; Displayed data: Power and energy, PV\/AC data, serial number, firmware and grid code; Diagnostics: Alarm codes and corresponding guidance in app; Settings: On\/off, date\/time, output percentage, power factor, grid code\/protection, work mode and EPM; Communication ports: USB logger, two RS485 monitoring ports, 16-pin METER\/RSD\/ATS and DRM RJ45; Remote monitoring: SolisCloud through suitable Wi-Fi\/LAN\/4G logger according to configuration; Monitoring daisy chain: RS485 or PLC according to selected communication; PLC arrangement: PLC CCO +datalogger; 16-pin \u2014 PC-485-IN: 1 B \/2 A \/3 GND; 16-pin \u2014 PC-485-OUT: 14 B \/15 A \/16 GND; PC-485 purpose: Dedicated primary\/secondary EPM connection, independent of monitoring; 16-pin \u2014 Meter-2: 4 A \/5 B.<\/p>\n<p>16-pin \u2014 Meter: 8 A \/9 B; 16-pin \u2014 ATS-IN: 6 0 V \/7 5 V; 16-pin \u2014 RSD: 10 RSD+ \/11 RSD\u2212; DRM logic control: RJ45:5 Switch_input1 \/6 Switch_input2; Logic control \u2014 response: When enabled opening limits output to 0 W within 5 s; RS485 \u2014 cable \/ torque: 0.5\u20130.75 mm\u00b2 \/0.6 Nm; EPM solution 1: Solis-EPM3-5G-PRO +Meter; \u226420; EPM solution 2: S3-Logger-EPM \/MB-S4-W4 +Meter; \u226445; EPM solution 3: G3-Gateway +Meter; \u2264105; EPM solution 4: Meter; \u226410; EPM primary \/ secondary meter: ADL400-C; menu ADL400C; Meter \u2014 connection: 21 A \/22 B \u2192Meter-2 4 A \/5 B; Meter CTs: Secondary current &lt;6 A; suitable class 0.5; primary range according to system maximum current; CT orientation: P2 towards utility grid; Meter \u2014 reference settings: 38400 baud; CT 400:1 for documented arrangement, ratio according to actual CTs; EPM addresses: Primary 1, secondary 2\u201310, each unique; separate from monitoring address; EPM interconnection: PC-485-OUT14\/15\/16 \u2192PC-485-IN1\/2\/3 of next device; AC source modes: AUTO \/Forced Grid \/Forced Genset \/AutoACbox; EPM grid configuration: 3P-3W; optional supported 3P-4W configuration; EPM control: Minimum \/Average; Unbalance in supported 3P-4W configuration; Generator \u2014 control: AUTO for one source; AutoACbox for multiple sources, up to 8 power settings; Minimum or supported Unbalance; Unbalanced control \u2014 wiring: Supported 3P-4W variant, connected neutral and consistent phase sequence across primary\/secondary units; Ingress protection: IP66; Topology: Transformerless; Cooling: Intelligent fan cooling, redundant per manual; Operating temperature: \u221230\u2026+60 \u00b0C; Operating humidity: 0\u2013100 % RH; Altitude: 4000 m; Storage temperature: \u221240\u2026+70 \u00b0C; Storage humidity: 0\u201395 % RH non-condensing; Package stacking: 3; Mounting position: Vertical on firm fire-resistant structure; other arrangements per mounting diagram; Mounting clearances: 700 mm above, sides and floor; 1000 mm front; Multiple unit clearances: \u2265700 mm; Mounting structure design load: At least four times unit weight, 420 kg; Handling: Four supplied handles and suitable lifting equipment for 105 kg; Bracket \u2014 dimensions: 873 \u00d7515 mm; Bracket \u2014 hole spacing \/ slots: 817 \u00d7414.5 mm;4 \u00d721 \u00d711 mm; Anchoring \u2014 depth \/ torque: \u22643.8 in (96.52 mm) \/30\u201335 Nm; Locking screws: M6 \u00d714 \/2\u20133 Nm; Cable support from terminals: 300\u2013350 mm; External earthing: M10 \u00d720, 10\u201312 Nm; outdoor copper conductor according to design; Earthing \u2014 cable table: 35\u201350 mm\u00b2, recommended 50 mm\u00b2; final sizing according to ampacity and project; AC phase conductors \u2014 detailed: 70\u2013400 mm\u00b2; recommended 120 mm\u00b2; AC conductors \u2014 summary table: 95\u2013400 mm\u00b2; AC conduit diameter: 30\u201375 mm; Reference AC cable length: 140 m; AC phase terminals: M12 \/20\u201330 Nm; AC neutral terminal: M12 \/20\u201330 Nm; M6 \/5\u20137 Nm; AC PE terminal: M10 \/12\u201316 Nm; AC stripping: Sheath 200 mm; S2=S1+2\u20133 mm; Aluminium AC conductors: Cu\/Al bimetal lugs according to cable and design; Recommended AC breaker: 300 A; IEC\/EN60947-3; DC conductors: PV1-F Cu 4\u20136 mm\u00b2, recommended 4 mm\u00b2; \u00d85.5\u20139 mm; DC connectors \/ stripping \/ torque: MC4 \/7 mm \/3\u20134 Nm; Large cable grommets: 30\u201340 \/50\u201355 \/60\u201365 \/70\u201375 mm; Small cable grommets: 18\u201322 \/28\u201332 mm; Vent valve: STG-4150HA \/3.5\u20134 Nm; Fan servicing \u2014 space: 600 mm for module withdrawal; Package \u2014 inverter \/ bracket \/ manual: 1 \/1 \/1; Package \u2014 screws: 2 \u00d7M6 \u00d714;4 \u00d7M10 \u00d740 +nuts and washers; Package \u2014 DC \/ 2-pin \/ RJ45: 21 \/2 \/1; Package \u2014 handles \/16-pin COM: 4 \/1; Plant components: Modules, mounting accessories, cables and protection; meter, CTs, logger, EPM or AC source box according to design; Grid standards: G99; IEC61727; EN50549-1\/2; VDE4110; Safety: IEC\/EN62109-1\/-2; IEC60947-2; EMC: IEC\/EN61000-6-2\/-4; Estimated delivery: 2\u20133 days.<\/p>\n<p><a href=\"https:\/\/batterado.com\/product\/solis-s6-gc3p150k07-nv-nd-trifazovy-sitovy-stridac\/\">Batterado \u2014 SOLIS-S6-GC3P150K07-NV-ND<\/a><\/p>\n<p><a href=\"https:\/\/batterado.com\/wp-content\/themes\/wodatherm\/assets\/documents\/products\/solis-s6-gc3p150k07-nv-nd-en.md\">Markdown \u2014 SOLIS-S6-GC3P150K07-NV-ND<\/a><\/p>\n<\/section>\n","protected":false},"excerpt":{"rendered":"<p>150 kW for large commercial PV with seven MPPTs, 21 strings and up to 54 A per tracker. Solis S6-GC3P150K07-NV-ND provides maximum AC output 165 kW, up to 98.8% efficiency and clear local Bluetooth control through SolisCloud. Its 105 kg IP66 enclosure connects a high-output PV array with a three-phase grid. String monitoring, I\/V scanning and thermal protection support plant operation. This offer includes DC switch and PID.<\/p>\n","protected":false},"featured_media":58737,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[2881],"product_cat":[3088],"product_tag":[3491,3446,3492,3448],"class_list":["post-58736","product","type-product","status-publish","has-post-thumbnail","product_brand-solis-storage-energy","product_cat-solar-inverters","product_tag-7-mppt","product_tag-grid-inverter","product_tag-solis-s6-gc3p150k07-nv-nd","product_tag-three-phase-inverter","first","onbackorder","taxable","shipping-taxable","purchasable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product\/58736","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/comments?post=58736"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/media\/58737"}],"wp:attachment":[{"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/media?parent=58736"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product_brand?post=58736"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product_cat?post=58736"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product_tag?post=58736"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}