{"id":58545,"date":"2026-11-01T03:57:22","date_gmt":"2026-11-01T01:57:22","guid":{"rendered":"https:\/\/batterado.com\/?post_type=product&#038;p=58545"},"modified":"2026-11-01T13:51:36","modified_gmt":"2026-11-01T11:51:36","slug":"solis-s5-gc60k-trifazovy-sitovy-stridac","status":"publish","type":"product","link":"https:\/\/batterado.com\/en\/product\/solis-s5-gc60k-trifazovy-sitovy-stridac\/","title":{"rendered":"Solis S5-GC60K \u2014 60 kW three-phase grid inverter, 6 MPPT, IP66"},"content":{"rendered":"<h2>Technical specifications<\/h2>\n<div class=\"wt-tech-grid\">\n<table>\n<tbody>\n<tr>\n<th>Manufacturer<\/th>\n<td>Solis \/ Ginlong Technologies<\/td>\n<\/tr>\n<tr>\n<th>Model<\/th>\n<td>S5-GC60K<\/td>\n<\/tr>\n<tr>\n<th>Type and role<\/th>\n<td>Three-phase grid-connected PV inverter<\/td>\n<\/tr>\n<tr>\n<th>Offered configuration<\/th>\n<td>Standard 400V model with 6 MPPTs and DC switch<\/td>\n<\/tr>\n<tr>\n<th>Operating configuration<\/th>\n<td>PV array and three-phase utility grid<\/td>\n<\/tr>\n<tr>\n<th>Maximum DC voltage<\/th>\n<td>1100 V<\/td>\n<\/tr>\n<tr>\n<th>Rated DC voltage<\/th>\n<td>600 V<\/td>\n<\/tr>\n<tr>\n<th>Start-up voltage<\/th>\n<td>195 V<\/td>\n<\/tr>\n<tr>\n<th>MPPT range<\/th>\n<td>180\u20131000 V<\/td>\n<\/tr>\n<tr>\n<th>Full-load MPPT range<\/th>\n<td>550\u2013850 V<\/td>\n<\/tr>\n<tr>\n<th>Maximum input current per MPPT<\/th>\n<td>32 A \/ MPPT<\/td>\n<\/tr>\n<tr>\n<th>Maximum short-circuit current per MPPT<\/th>\n<td>40 A \/ MPPT<\/td>\n<\/tr>\n<tr>\n<th>Independent MPPT count<\/th>\n<td>6<\/td>\n<\/tr>\n<tr>\n<th>Maximum PV string count<\/th>\n<td>12<\/td>\n<\/tr>\n<tr>\n<th>Strings per MPPT<\/th>\n<td>2 \/ MPPT<\/td>\n<\/tr>\n<tr>\n<th>Rated AC power<\/th>\n<td>60000 W<\/td>\n<\/tr>\n<tr>\n<th>Maximum AC power<\/th>\n<td>66000 W<\/td>\n<\/tr>\n<tr>\n<th>Maximum apparent AC power<\/th>\n<td>66000 VA<\/td>\n<\/tr>\n<tr>\n<th>Grid conductors<\/th>\n<td>3 \/ N \/ PE<\/td>\n<\/tr>\n<tr>\n<th>Rated grid voltage<\/th>\n<td>220 \/ 380 V; 230 \/ 400 V<\/td>\n<\/tr>\n<tr>\n<th>Rated frequency<\/th>\n<td>50 \/ 60 Hz<\/td>\n<\/tr>\n<tr>\n<th>Rated current at 380\/400 V<\/th>\n<td>91.2 \/ 86.6 A<\/td>\n<\/tr>\n<tr>\n<th>Maximum AC current<\/th>\n<td>100.3 A<\/td>\n<\/tr>\n<tr>\n<th>Power factor<\/th>\n<td>&gt;0.99; adjustable 0.8 leading to 0.8 lagging<\/td>\n<\/tr>\n<tr>\n<th>THDi<\/th>\n<td>&lt;3 %<\/td>\n<\/tr>\n<tr>\n<th>Maximum efficiency<\/th>\n<td>98.7 %<\/td>\n<\/tr>\n<tr>\n<th>European efficiency<\/th>\n<td>98.3 %<\/td>\n<\/tr>\n<tr>\n<th>Topology<\/th>\n<td>Transformerless<\/td>\n<\/tr>\n<tr>\n<th>Night consumption<\/th>\n<td>&lt;1 W<\/td>\n<\/tr>\n<tr>\n<th>DC polarity protection<\/th>\n<td>Integrated function<\/td>\n<\/tr>\n<tr>\n<th>Short-circuit protection<\/th>\n<td>Integrated function<\/td>\n<\/tr>\n<tr>\n<th>AC overcurrent protection<\/th>\n<td>Integrated function<\/td>\n<\/tr>\n<tr>\n<th>Surge protection<\/th>\n<td>DC Type II \/ AC Type II<\/td>\n<\/tr>\n<tr>\n<th>Grid monitoring<\/th>\n<td>Integrated function<\/td>\n<\/tr>\n<tr>\n<th>Anti-islanding protection<\/th>\n<td>Integrated function<\/td>\n<\/tr>\n<tr>\n<th>Temperature protection<\/th>\n<td>Integrated function<\/td>\n<\/tr>\n<tr>\n<th>Multi-peak MPPT scanning<\/th>\n<td>Integrated function<\/td>\n<\/tr>\n<tr>\n<th>DC switch<\/th>\n<td>Integrated function<\/td>\n<\/tr>\n<tr>\n<th>AFCI 2.0 arc protection<\/th>\n<td>Optional configuration<\/td>\n<\/tr>\n<tr>\n<th>DC connectors<\/th>\n<td>MC4<\/td>\n<\/tr>\n<tr>\n<th>AC terminal connection<\/th>\n<td>OT terminal block up to 70 mm\u00b2; L1 \/ L2 \/ L3 \/ N \/ PE<\/td>\n<\/tr>\n<tr>\n<th>AC \u2014 phase \/ PE lugs<\/th>\n<td>M8 \/ M6<\/td>\n<\/tr>\n<tr>\n<th>AC \u2014 neutral connection<\/th>\n<td>With or without neutral according to local grid requirements<\/td>\n<\/tr>\n<tr>\n<th>Communication<\/th>\n<td>RS485 \/ USB<\/td>\n<\/tr>\n<tr>\n<th>Communication connectors<\/th>\n<td>4-pin COM for data logger; 16-pin COM for RS485, meter and DRM<\/td>\n<\/tr>\n<tr>\n<th>COM \u2014 nut \/ terminals<\/th>\n<td>3.5\u20134 Nm \/ 0.4\u20130.6 Nm<\/td>\n<\/tr>\n<tr>\n<th>16-pin COM \u2014 DRM pins 9\u201312<\/th>\n<td>9 DRM1\/5; 10 DRM2\/6; 11 DRM3\/7; 12 DRM4\/8<\/td>\n<\/tr>\n<tr>\n<th>16-pin COM \u2014 supply pins<\/th>\n<td>15 V+ 12 V; 16 V\u2212 GND<\/td>\n<\/tr>\n<tr>\n<th>16-pin COM \u2014 reserved pins<\/th>\n<td>5 \/ 8<\/td>\n<\/tr>\n<tr>\n<th>RS485 \u2014 IN \/ OUT terminals<\/th>\n<td>16pin COM: 3 A \/ 4 B IN; 6 A \/ 7 B OUT<\/td>\n<\/tr>\n<tr>\n<th>RS485 \u2014 conductor \/ cable diameter<\/th>\n<td>0.75\u20133 mm\u00b2 \/ 4\u20136 mm<\/td>\n<\/tr>\n<tr>\n<th>COM \u2014 conductor stripping<\/th>\n<td>10\u201312 mm<\/td>\n<\/tr>\n<tr>\n<th>Digital meter<\/th>\n<td>Compatible Solis three-phase meter with external CTs according to design<\/td>\n<\/tr>\n<tr>\n<th>Meter \u2014 communication terminals<\/th>\n<td>Meter 21 A \/ 22 B \u2192 pins 1 A \/ 2 B of 16-pin COM<\/td>\n<\/tr>\n<tr>\n<th>Remote monitoring<\/th>\n<td>Optional Wi-Fi \/ GPRS \/ LAN loggers and Wi-Fi \/ GPRS box for multiple devices<\/td>\n<\/tr>\n<tr>\n<th>Inverter monitoring address<\/th>\n<td>01\u201399; default 01<\/td>\n<\/tr>\n<tr>\n<th>LCD display<\/th>\n<td>LCD with capacitive touch buttons<\/td>\n<\/tr>\n<tr>\n<th>Controls<\/th>\n<td>ESC \/ UP \/ DOWN \/ ENTER<\/td>\n<\/tr>\n<tr>\n<th>LED indicators<\/th>\n<td>POWER \/ OPERATION \/ ALARM<\/td>\n<\/tr>\n<tr>\n<th>Displayed operating data<\/th>\n<td>PV and phase voltages\/currents, power, frequency, energy, status, serial number and version<\/td>\n<\/tr>\n<tr>\n<th>Generation history<\/th>\n<td>Daily, monthly and yearly energy<\/td>\n<\/tr>\n<tr>\n<th>Alarm \/ warning history<\/th>\n<td>Latest 100 records in each history<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<th>Export control<\/th>\n<td>Internal EPM; Meter in Load \/ Meter in Grid \/ Consumption Monitor<\/td>\n<\/tr>\n<tr>\n<th>Export-limit modes<\/th>\n<td>01 average \/ 02 according to lowest-loaded phase<\/td>\n<\/tr>\n<tr>\n<th>24-hour consumption monitoring<\/th>\n<td>Grid-side meter, 24H Switch and Solis monitoring<\/td>\n<\/tr>\n<tr>\n<th>Meter failsafe<\/th>\n<td>Configurable alarm and generation stop on metering loss<\/td>\n<\/tr>\n<tr>\n<th>External EPM<\/th>\n<td>5G-EPM \/ Others-EPM according to actual device<\/td>\n<\/tr>\n<tr>\n<th>Active and reactive power control<\/th>\n<td>Active\/reactive output settings and grid working mode<\/td>\n<\/tr>\n<tr>\n<th>DRM \u2014 logic interface<\/th>\n<td>16pin COM: 13 RefGen \/ 14 Com\/DRM0<\/td>\n<\/tr>\n<tr>\n<th>DRM \u2014 response after opening<\/th>\n<td>Limit to 0 W within 5 s when enabled according to grid profile<\/td>\n<\/tr>\n<tr>\n<th>Service updates<\/th>\n<td>HMI \/ DSP<\/td>\n<\/tr>\n<tr>\n<th>Service compensation settings<\/th>\n<td>Output energy and voltage calibration for grid-operator requirements<\/td>\n<\/tr>\n<tr>\n<th>String monitoring<\/th>\n<td>Integrated<\/td>\n<\/tr>\n<tr>\n<th>PID recovery<\/th>\n<td>Optional configuration<\/td>\n<\/tr>\n<tr>\n<th>Night reactive-power compensation<\/th>\n<td>Night SVG; configuration according to design<\/td>\n<\/tr>\n<tr>\n<th>Night-function selection<\/th>\n<td>Select PID-recovery or night reactive-power-compensation configuration according to design<\/td>\n<\/tr>\n<tr>\n<th>I\/V curve scanning<\/th>\n<td>Integrated function<\/td>\n<\/tr>\n<tr>\n<th>I\/V scan \u2014 start \/ step \/ points<\/th>\n<td>100\u20131100 V \/ 1\u2013100 V \/ 60<\/td>\n<\/tr>\n<tr>\n<th>Service fan test<\/th>\n<td>Fan Test<\/td>\n<\/tr>\n<tr>\n<th>User-Def \u2014 grid-profile use<\/th>\n<td>Service configuration with grid-operator permission; L\u2013N ranges per manual<\/td>\n<\/tr>\n<tr>\n<th>User-Def \u2014 overvoltage OV-G-V1 \/ V2<\/th>\n<td>220\u2013374 V; 0.01\u2013300 s<\/td>\n<\/tr>\n<tr>\n<th>User-Def \u2014 undervoltage UN-G-V1 \/ V2<\/th>\n<td>110\u2013277 V; 0.01\u2013300 s<\/td>\n<\/tr>\n<tr>\n<th>User-Def \u2014 overfrequency OV-G-F1 \/ F2<\/th>\n<td>50.1\u201365 Hz; 0.01\u2013300 s<\/td>\n<\/tr>\n<tr>\n<th>User-Def \u2014 underfrequency UN-G-F1 \/ F2<\/th>\n<td>45\u201359.9 Hz; 0.01\u2013300 s<\/td>\n<\/tr>\n<tr>\n<th>User-Def \u2014 Startup-T \/ Restore-T<\/th>\n<td>10\u2013600 s \/ 10\u2013600 s<\/td>\n<\/tr>\n<tr>\n<th>Dimensions W \u00d7 H \u00d7 D<\/th>\n<td>691 \u00d7 578 \u00d7 338 mm<\/td>\n<\/tr>\n<tr>\n<th>Weight<\/th>\n<td>53.7 kg<\/td>\n<\/tr>\n<tr>\n<th>Ingress protection<\/th>\n<td>IP66<\/td>\n<\/tr>\n<tr>\n<th>Corrosion resistance<\/th>\n<td>C5<\/td>\n<\/tr>\n<tr>\n<th>Operating temperature<\/th>\n<td>\u221225 to +60 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th>Relative operating humidity<\/th>\n<td>0\u2013100 % RH<\/td>\n<\/tr>\n<tr>\n<th>Cooling<\/th>\n<td>Intelligent fan cooling<\/td>\n<\/tr>\n<tr>\n<th>Typical noise<\/th>\n<td>&lt;55 dB(A)<\/td>\n<\/tr>\n<tr>\n<th>Maximum altitude<\/th>\n<td>4000 m<\/td>\n<\/tr>\n<tr>\n<th>Storage temperature<\/th>\n<td>\u221240 to +70 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th>Storage humidity<\/th>\n<td>0\u201395 % RH, non-condensing<\/td>\n<\/tr>\n<tr>\n<th>Stacking packaged units<\/th>\n<td>Maximum 4 units high<\/td>\n<\/tr>\n<tr>\n<th>Mounting position<\/th>\n<td>Vertical or backward tilt up to 15\u00b0<\/td>\n<\/tr>\n<tr>\n<th>Airflow clearance<\/th>\n<td>500 mm at sides and above floor, 800 mm above enclosure and 1000 mm in front per figure3.1<\/td>\n<\/tr>\n<tr>\n<th>Mounting structure<\/th>\n<td>Firm fire-resistant wall or metal rack with airflow<\/td>\n<\/tr>\n<tr>\n<th>Mounting \u2014 anchors in manual<\/th>\n<td>Wall M10 \u00d7 90, maximum hole depth 90 mm; rack M10 \u00d7 40<\/td>\n<\/tr>\n<tr>\n<th>Mounting \u2014 bracket dimensions<\/th>\n<td>636 \u00d7 272 mm; \u00d811 mm; 44.5 \/ 24 \/ 11 mm<\/td>\n<\/tr>\n<tr>\n<th>Mounting \u2014 bracket \/ fastening torque<\/th>\n<td>30\u201335 Nm \/ 2\u20133 Nm<\/td>\n<\/tr>\n<tr>\n<th>Rack mounting \u2014 hole and torque<\/th>\n<td>\u00d812.5 mm \/ 35 Nm<\/td>\n<\/tr>\n<tr>\n<th>Handling and lifting points<\/th>\n<td>Two people, integrated handles and suitable lifting technique<\/td>\n<\/tr>\n<tr>\n<th>External earthing<\/th>\n<td>Copper 25\u201350 mm\u00b2 per connection table, at least half the phase conductor size; external M10 lug, 5\u20136 Nm<\/td>\n<\/tr>\n<tr>\n<th>DC cable<\/th>\n<td>4\u20136 mm\u00b2; recommended 4 mm\u00b2, PV1-F; diameter 5.5\u20139 mm<\/td>\n<\/tr>\n<tr>\n<th>DC \u2014 stripping length<\/th>\n<td>7 mm<\/td>\n<\/tr>\n<tr>\n<th>DC \u2014 connector torque<\/th>\n<td>3\u20134 Nm<\/td>\n<\/tr>\n<tr>\n<th>AC cable<\/th>\n<td>Terminal range 10\u201370 mm\u00b2; connection overview 35\u201370 mm\u00b2; recommended 35 mm\u00b2<\/td>\n<\/tr>\n<tr>\n<th>AC \u2014 cable outer diameter<\/th>\n<td>37\u201344 mm; recommended 40 mm<\/td>\n<\/tr>\n<tr>\n<th>AC \u2014 sheath and conductor stripping<\/th>\n<td>Sheath about 300 mm; conductor S2 = OT crimp length S1 + 2\u20133 mm<\/td>\n<\/tr>\n<tr>\n<th>AC \u2014 terminal torque<\/th>\n<td>10\u201320 Nm<\/td>\n<\/tr>\n<tr>\n<th>Recommended AC breaker<\/th>\n<td>125 A<\/td>\n<\/tr>\n<tr>\n<th>Package \u2014 inverter \/ bracket<\/th>\n<td>1 \/ 1<\/td>\n<\/tr>\n<tr>\n<th>Package \u2014 cross \/ hex screws<\/th>\n<td>4 \u00d7 M4 \u00d7 14 \/ 2 \u00d7 M6 \u00d7 12<\/td>\n<\/tr>\n<tr>\n<th>Package \u2014 DC connectors<\/th>\n<td>12<\/td>\n<\/tr>\n<tr>\n<th>Package \u2014 AC cover \/ 16-pin COM \/ tool \/ manual<\/th>\n<td>1 \/ 1 \/ 1 \/ 1<\/td>\n<\/tr>\n<tr>\n<th>Optional system components<\/th>\n<td>Compatible three-phase CT meter, logger and external EPM according to design<\/td>\n<\/tr>\n<tr>\n<th>Safety<\/th>\n<td>IEC \/ EN 62109-1 \/ -2<\/td>\n<\/tr>\n<tr>\n<th>EMC<\/th>\n<td>IEC \/ EN 61000-6-1 \/ -2 \/ -3 \/ -4<\/td>\n<\/tr>\n<tr>\n<th>Grid standards<\/th>\n<td>G99; VDE-AR-N 4105 \/ VDE V 0124; EN 50549-1; VDE 0126 \/ UTE C 15 \/ VFR:2019; RD 1699 \/ RD 244 \/ UNE 206006 \/ UNE 206007-1; CEI 0-21; C10\/11; NRS 097-2-1; EIFS 2018.2; IEC 62116 \/ 61727 \/ 60068 \/ 61683; EN 50530<\/td>\n<\/tr>\n<tr>\n<th>Estimated delivery<\/th>\n<td>2\u20133 days<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2>Generation for business and industry<\/h2>\n<p>S5-GC60K converts module energy for the three-phase supply point of a commercial site, hall or industrial building. Its 60 kW rating describes instantaneous conversion; daily kWh depend on irradiation and array design. The operating system consists of PV modules, grid inverter and connected utility grid. Generation serves local consumption and grid export is managed for the actual connection.<\/p>\n<h2>Distributing arrays across MPPTs<\/h2>\n<p>6 independent trackers serve up to 12 strings, two per MPPT. Maximum input current is 32 A and short-circuit current 40 A per tracker. Start-up voltage is 195 V, MPPT range 180\u20131000 V and full-load range 550\u2013850 V. Maximum DC voltage is 1100 V. Each MPPT group uses matching module type and count with corresponding orientation; design checks currents and open-circuit voltage at the local minimum temperature.<\/p>\n<h2>Output and efficient conversion<\/h2>\n<p>Rated output of 60000 W is complemented by maximum 66000 W and 66000 VA. The manufacturer specifies 100.3 A maximum AC current and 91.2 \/ 86.6 A rated current at 380\/400 V. Connection 3\/N\/PE uses 220\/380 or 230\/400 V at 50\/60 Hz. Maximum efficiency is 98.7 %, European efficiency 98.3 % and THDi below 3 %. Adjustable power factor supports grid requirements. Transformerless construction has night consumption below 1 W.<\/p>\n<h2>Metering for export and consumption<\/h2>\n<p>A compatible three-phase meter with external current transformers provides energy-flow data. Terminals 21 A and 22 B of the illustrated meter connect to pins 1 A and 2 B of the 16-pin COM. The manual shows grid-side and load-side metering for export control. A 24-hour overview uses a grid-side meter, enabled 24H Switch and Solis monitoring. Select the meter and transformers for the actual installation.<\/p>\n<h2>Output and export management<\/h2>\n<p>Internal EPM offers Meter in Load, Meter in Grid and Consumption Monitor. Mode 01 uses average three-phase consumption; mode 02 follows the lowest-loaded phase. Permitted export is configured for the connection design. Configurable failsafe can alarm and stop generation on metering loss. External control supports 5G-EPM or Others-EPM according to the device. Commissioning verifies metering direction and overall response.<\/p>\n<h2>Multi-device communication<\/h2>\n<p>The 4-pin COM accepts an optional logger for one inverter. The 16-pin COM combines RS485, metering and logic control. Daisy-chain communication uses pins 3\/4 as input and 6\/7 as output; addresses range 01\u201399, default 01. The manual lists Wi-Fi, GPRS and LAN loggers and Wi-Fi\/GPRS boxes for multiple devices. Communication cable uses 0.75\u20133 mm\u00b2 conductors, 4\u20136 mm diameter and 10\u201312 mm stripping; the full pinout appears in the technical overview and gallery.<\/p>\n<h2>Generation overview and I\/V curves<\/h2>\n<p>The LCD with capacitive buttons shows MPPT and individual string voltages\/currents, output, frequency, energy and operating state. Daily, monthly and yearly history and the latest 100 alarms and 100 warnings are available. Individual-string I\/V scanning sets a 100\u20131100 V start and 1\u2013100 V step with 60 data points. Service menus include fan testing, HMI\/DSP updates and output-energy\/voltage calibration for grid-operator requirements.<\/p>\n<h2>Durable construction and environment<\/h2>\n<p>The 691 \u00d7 578 \u00d7 338 mm enclosure weighs 53.7 kg. IP66 provides dust-tight protection against powerful water jets; C5 corrosion resistance complements suitable indoor or outdoor placement. Intelligent fan cooling supports \u221225 to +60 \u00b0C operation at 0\u2013100 % humidity and altitude up to 4000 m. Typical noise is below 55 dB(A). The site provides airflow and shelter from direct sun. Storage conditions are \u221240 to +70 \u00b0C and 0\u201395 % non-condensing humidity; packaged units may be stacked up to four high.<\/p>\n<h2>Mounting and power terminals<\/h2>\n<p>Mount on a fire-resistant wall or metal rack vertically or tilted backward up to 15\u00b0. Exact bracket dimensions, clearances and torques appear in the technical overview. Two people and suitable technique use the integrated handles. AC terminals accept M8 lugs, PE uses M6 and the separate external earth point uses M10. Recommended AC conductor size is 35 mm\u00b2 and this model\u2019s breaker is 125 A. Neutral connection follows local grid requirements. DC uses MC4 and 4\u20136 mm\u00b2 copper conductors.<\/p>\n<h2>Protection and night-function selection<\/h2>\n<p>Integrated protection covers DC polarity, short circuit, AC overcurrent, grid monitoring, anti-islanding and temperature; Type II surge protection is fitted on DC and AC sides. The current matrix listsAFCI 2.0 as optional. Night functions use a selected PID-recovery or Night SVG reactive-power-compensation configuration. The European logic interface uses pins 13 RefGen and 14 Com\/DRM0; when enabled under the grid profile, opening the contact reduces output to 0 W within five seconds.<\/p>\n<h2>Equipment and matching components<\/h2>\n<p>The package includes the inverter, bracket, four M4 \u00d7 14 screws, two M6 \u00d7 12 screws, 12 DC connectors, AC terminal cover, 16-pin COM connector, unlocking tool and manual. The offer includes the DC switch. Modules, CT meter, logger, protection and mounting components are selected for the whole plant. Design compares kW output with consumption patterns and kWh energy. Any storage uses a separate compatible battery system and appropriate converter. Batterado helps match the components for the connection.<\/p>\n<h2>Downloads<\/h2>\n<ul>\n<li><a href=\"https:\/\/batterado.com\/wp-content\/themes\/wodatherm\/assets\/documents\/solar-projects\/solis-s5-gc50-60-datasheet-v38.pdf\">Solis S5-GC 50\u201360 kW \u2014 datasheet V3.8<\/a><\/li>\n<li><a href=\"https:\/\/batterado.com\/wp-content\/themes\/wodatherm\/assets\/documents\/solar-projects\/solis-s5-gc50-60-manual-v13.pdf\">Solis S5-GC 50\u201360 kW \u2014 EUR user manual V1.3<\/a><\/li>\n<li><a href=\"https:\/\/batterado.com\/wp-content\/themes\/wodatherm\/assets\/documents\/products\/solis-s5-gc60k-en.md\">Complete product overview \u2014 Markdown<\/a><\/li>\n<\/ul>\n<section class=\"tomo-ai-search-profile\">\n<h2>AI search description<\/h2>\n<p>High-output PV for commercial and industrial sites with flexible array grouping. Solis S5-GC60K delivers 60 kW rated output to a three-phase grid and connects up to 12 strings through 6 independent MPPTs. Each tracker supports 32 A and a 180\u20131000 V operating range. Up to 98.7 % efficiency, intelligent fan cooling, IP66 and C5 corrosion resistance support demanding installations at suitable locations. String monitoring and I\/V scanning provide insight into generation. A compatible meter adds export control and suitable Solis monitoring enables a 24-hour consumption view. The practical 16-pin COM combines metering, multi-inverter communication and logic control. This offer includes the DC switch and standard connection components. S5-GC60K converts module energy for the three-phase supply point of a commercial site, hall or industrial building. Its 60 kW rating describes instantaneous conversion; daily kWh depend on irradiation and array design. The operating system consists of PV modules, grid inverter and connected utility grid. Generation serves local consumption and grid export is managed for the actual connection. The package includes the inverter, bracket, four M4 \u00d7 14 screws, two M6 \u00d7 12 screws, 12 DC connectors, AC terminal cover, 16-pin COM connector, unlocking tool and manual. The offer includes the DC switch. Modules, CT meter, logger, protection and mounting components are selected for the whole plant. Design compares kW output with consumption patterns and kWh energy. Any storage uses a separate compatible battery system and appropriate converter. Batterado helps match the components for the connection.<\/p>\n<p>Manufacturer: Solis \/ Ginlong Technologies; Model: S5-GC60K; Type and role: Three-phase grid-connected PV inverter; Offered configuration: Standard 400V model with 6 MPPTs and DC switch; Operating configuration: PV array and three-phase utility grid; Maximum DC voltage: 1100 V; Rated DC voltage: 600 V; Start-up voltage: 195 V; MPPT range: 180\u20131000 V; Full-load MPPT range: 550\u2013850 V; Maximum input current per MPPT: 32 A \/ MPPT; Maximum short-circuit current per MPPT: 40 A \/ MPPT; Independent MPPT count: 6; Maximum PV string count: 12; Strings per MPPT: 2 \/ MPPT; Rated AC power: 60000 W; Maximum AC power: 66000 W; Maximum apparent AC power: 66000 VA; Grid conductors: 3 \/ N \/ PE; Rated grid voltage: 220 \/ 380 V; 230 \/ 400 V; Rated frequency: 50 \/ 60 Hz; Rated current at 380\/400 V: 91.2 \/ 86.6 A; Maximum AC current: 100.3 A; Power factor: &gt;0.99; adjustable 0.8 leading to 0.8 lagging; THDi: &lt;3 %; Maximum efficiency: 98.7 %; European efficiency: 98.3 %; Topology: Transformerless; Night consumption: &lt;1 W; DC polarity protection: Integrated function; Short-circuit protection: Integrated function; AC overcurrent protection: Integrated function; Surge protection: DC Type II \/ AC Type II; Grid monitoring: Integrated function; Anti-islanding protection: Integrated function; Temperature protection: Integrated function; Multi-peak MPPT scanning: Integrated function; DC switch: Integrated function; AFCI 2.0 arc protection: Optional configuration; DC connectors: MC4; AC terminal connection: OT terminal block up to 70 mm\u00b2; L1 \/ L2 \/ L3 \/ N \/ PE; AC \u2014 phase \/ PE lugs: M8 \/ M6; AC \u2014 neutral connection: With or without neutral according to local grid requirements; Communication: RS485 \/ USB; Communication connectors: 4-pin COM for data logger; 16-pin COM for RS485, meter and DRM; COM \u2014 nut \/ terminals: 3.5\u20134 Nm \/ 0.4\u20130.6 Nm; 16-pin COM \u2014 DRM pins 9\u201312: 9 DRM1\/5; 10 DRM2\/6; 11 DRM3\/7; 12 DRM4\/8; 16-pin COM \u2014 supply pins: 15 V+ 12 V; 16 V\u2212 GND; 16-pin COM \u2014 reserved pins: 5 \/ 8; RS485 \u2014 IN \/ OUT terminals: 16pin COM: 3 A \/ 4 B IN; 6 A \/ 7 B OUT; RS485 \u2014 conductor \/ cable diameter: 0.75\u20133 mm\u00b2 \/ 4\u20136 mm; COM \u2014 conductor stripping: 10\u201312 mm; Digital meter: Compatible Solis three-phase meter with external CTs according to design; Meter \u2014 communication terminals: Meter 21 A \/ 22 B \u2192 pins 1 A \/ 2 B of 16-pin COM; Remote monitoring: Optional Wi-Fi \/ GPRS \/ LAN loggers and Wi-Fi \/ GPRS box for multiple devices; Inverter monitoring address: 01\u201399; default 01; LCD display: LCD with capacitive touch buttons; Controls: ESC \/ UP \/ DOWN \/ ENTER; LED indicators: POWER \/ OPERATION \/ ALARM; Displayed operating data: PV and phase voltages\/currents, power, frequency, energy, status, serial number and version.<\/p>\n<p>Generation history: Daily, monthly and yearly energy; Alarm \/ warning history: Latest 100 records in each history; Export control: Internal EPM; Meter in Load \/ Meter in Grid \/ Consumption Monitor; Export-limit modes: 01 average \/ 02 according to lowest-loaded phase; 24-hour consumption monitoring: Grid-side meter, 24H Switch and Solis monitoring; Meter failsafe: Configurable alarm and generation stop on metering loss; External EPM: 5G-EPM \/ Others-EPM according to actual device; Active and reactive power control: Active\/reactive output settings and grid working mode; DRM \u2014 logic interface: 16pin COM: 13 RefGen \/ 14 Com\/DRM0; DRM \u2014 response after opening: Limit to 0 W within 5 s when enabled according to grid profile; Service updates: HMI \/ DSP; Service compensation settings: Output energy and voltage calibration for grid-operator requirements; String monitoring: Integrated; PID recovery: Optional configuration; Night reactive-power compensation: Night SVG; configuration according to design; Night-function selection: Select PID-recovery or night reactive-power-compensation configuration according to design; I\/V curve scanning: Integrated function; I\/V scan \u2014 start \/ step \/ points: 100\u20131100 V \/ 1\u2013100 V \/ 60; Service fan test: Fan Test; User-Def \u2014 grid-profile use: Service configuration with grid-operator permission; L\u2013N ranges per manual; User-Def \u2014 overvoltage OV-G-V1 \/ V2: 220\u2013374 V; 0.01\u2013300 s; User-Def \u2014 undervoltage UN-G-V1 \/ V2: 110\u2013277 V; 0.01\u2013300 s; User-Def \u2014 overfrequency OV-G-F1 \/ F2: 50.1\u201365 Hz; 0.01\u2013300 s; User-Def \u2014 underfrequency UN-G-F1 \/ F2: 45\u201359.9 Hz; 0.01\u2013300 s; User-Def \u2014 Startup-T \/ Restore-T: 10\u2013600 s \/ 10\u2013600 s; Dimensions W \u00d7 H \u00d7 D: 691 \u00d7 578 \u00d7 338 mm; Weight: 53.7 kg; Ingress protection: IP66; Corrosion resistance: C5; Operating temperature: \u221225 to +60 \u00b0C; Relative operating humidity: 0\u2013100 % RH; Cooling: Intelligent fan cooling; Typical noise: &lt;55 dB(A); Maximum altitude: 4000 m; Storage temperature: \u221240 to +70 \u00b0C; Storage humidity: 0\u201395 % RH, non-condensing; Stacking packaged units: Maximum 4 units high; Mounting position: Vertical or backward tilt up to 15\u00b0; Airflow clearance: 500 mm at sides and above floor, 800 mm above enclosure and 1000 mm in front per figure3.1; Mounting structure: Firm fire-resistant wall or metal rack with airflow; Mounting \u2014 anchors in manual: Wall M10 \u00d7 90, maximum hole depth 90 mm; rack M10 \u00d7 40; Mounting \u2014 bracket dimensions: 636 \u00d7 272 mm; \u00d811 mm; 44.5 \/ 24 \/ 11 mm; Mounting \u2014 bracket \/ fastening torque: 30\u201335 Nm \/ 2\u20133 Nm; Rack mounting \u2014 hole and torque: \u00d812.5 mm \/ 35 Nm; Handling and lifting points: Two people, integrated handles and suitable lifting technique; External earthing: Copper 25\u201350 mm\u00b2 per connection table, at least half the phase conductor size; external M10 lug, 5\u20136 Nm; DC cable: 4\u20136 mm\u00b2; recommended 4 mm\u00b2, PV1-F; diameter 5.5\u20139 mm; DC \u2014 stripping length: 7 mm; DC \u2014 connector torque: 3\u20134 Nm; AC cable: Terminal range 10\u201370 mm\u00b2; connection overview 35\u201370 mm\u00b2; recommended 35 mm\u00b2; AC \u2014 cable outer diameter: 37\u201344 mm; recommended 40 mm; AC \u2014 sheath and conductor stripping: Sheath about 300 mm; conductor S2 = OT crimp length S1 + 2\u20133 mm; AC \u2014 terminal torque: 10\u201320 Nm; Recommended AC breaker: 125 A; Package \u2014 inverter \/ bracket: 1 \/ 1; Package \u2014 cross \/ hex screws: 4 \u00d7 M4 \u00d7 14 \/ 2 \u00d7 M6 \u00d7 12; Package \u2014 DC connectors: 12; Package \u2014 AC cover \/ 16-pin COM \/ tool \/ manual: 1 \/ 1 \/ 1 \/ 1; Optional system components: Compatible three-phase CT meter, logger and external EPM according to design; Safety: IEC \/ EN 62109-1 \/ -2; EMC: IEC \/ EN 61000-6-1 \/ -2 \/ -3 \/ -4; Grid standards: G99; VDE-AR-N 4105 \/ VDE V 0124; EN 50549-1; VDE 0126 \/ UTE C 15 \/ VFR:2019; RD 1699 \/ RD 244 \/ UNE 206006 \/ UNE 206007-1; CEI 0-21; C10\/11; NRS 097-2-1; EIFS 2018.2; IEC 62116 \/ 61727 \/ 60068 \/ 61683; EN 50530; Estimated delivery: 2\u20133 days.<\/p>\n<p><a href=\"https:\/\/batterado.com\/product\/solis-s5-gc60k-trifazovy-sitovy-stridac\/\">Batterado \u2014 SOLIS-S5-GC60K<\/a><\/p>\n<p><a href=\"https:\/\/batterado.com\/wp-content\/themes\/wodatherm\/assets\/documents\/products\/solis-s5-gc60k-en.md\">Markdown \u2014 SOLIS-S5-GC60K<\/a><\/p>\n<\/section>\n","protected":false},"excerpt":{"rendered":"<p>High-output PV for commercial and industrial sites with flexible array grouping. Solis S5-GC60K delivers 60 kW rated output to a three-phase grid and connects up to 12 strings through 6 independent MPPTs. Each tracker supports 32 A and a 180\u20131000 V operating range. Up to 98.7 % efficiency, intelligent fan cooling, IP66 and C5 corrosion resistance support demanding installations at suitable locations. String monitoring and I\/V scanning provide insight into generation. A compatible meter adds export control and suitable Solis monitoring enables a 24-hour consumption view. The practical 16-pin COM combines metering, multi-inverter communication and logic control. This offer includes the DC switch and standard connection components.<\/p>\n","protected":false},"featured_media":58546,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[2881],"product_cat":[3088],"product_tag":[3467,3446,3468,3448],"class_list":["post-58545","product","type-product","status-publish","has-post-thumbnail","product_brand-solis-storage-energy","product_cat-solar-inverters","product_tag-6-mppt","product_tag-grid-inverter","product_tag-solis-s5-gc60k","product_tag-three-phase-inverter","first","onbackorder","taxable","shipping-taxable","purchasable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product\/58545","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/comments?post=58545"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/media\/58546"}],"wp:attachment":[{"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/media?parent=58545"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product_brand?post=58545"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product_cat?post=58545"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/batterado.com\/en\/wp-json\/wp\/v2\/product_tag?post=58545"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}