Store energy. Every way.™

Helping with technology for more than 25 years.More than 25 years on the market

Victron Energy Energy Meter VM-3P75CT three-phase energy meter 75 A with CTs, Ethernet and VE.Can (REL200300100)

5 150 Kč incl. VAT

Seller: Tomorrow Systems® s.r.o. – VAT payer

The Victron Energy Energy Meter VM-3P75CT measures power and energy of single-, split- and three-phase installations and connects without modifying existing wiring, because snap-on 75 A current transformers are included in the box.

  • Plug & Play as a grid meter, with the roles Grid Meter, PV Inverter, AC Genset or AC Load Meter selectable in VictronConnect.
  • Communication over Ethernet (Modbus UDP) and two VE.Can ports, 100 ms refresh rate.
  • Accurate measurement for ESS: grid import and grid feed-in.
  • 85 to 265 V AC L-N voltage input, self-powered via L1 and neutral.
  • Data in VictronConnect, on GX devices (Cerbo GX, Ekrano GX) and in the VRM portal.

The compact 90 × 71 × 59 mm module belongs in the distribution box next to the breakers. The package includes three snap-on transformers with a 640 mm cable and VE.Can terminators.

In stock

Enquiry

Description

Technical data

BrandVictron Energy
ModelEnergy Meter VM-3P75CT
Order codeREL200300100
TypeThree-phase energy meter with Ethernet and VE.Can
Usemeasuring power and energy of single-, split- and three-phase installations
Voltage connectiondirect
Input voltage range L-N85 to 265 V AC
Input voltage range L-L150 to 460 V AC
Frequency50/60 Hz
Current connectionvia current transformers (included, wire length 640 mm, bore diameter 10 ±0.5 mm)
Rated current75 A
Refresh rate100 ms
Power supplyself-powered via L1-N
Consumption1.45 W / 3.1 VA
VE.Can communication porttwo RJ45 connectors (VE.Can terminators included)
Ethernet communication portone RJ45 connector
Modbus UDPsupported via the Ethernet port, registers in the appendix of the manual
Communication protocolsVE.Can, Ethernet, Modbus UDP
Meter rolesGrid Meter, PV Inverter, AC Genset, AC Load Meter (set in VictronConnect)
Energy registration methodvector, arithmetic or absolute (configurable)
Measured parametersline-to-neutral and line-to-line voltage, power factor (IEEE convention), phase sequence, phase rotation warning, protective earth voltage, neutral and line currents
LEDstatus LED, configurable as an energy pulse output
CompatibilityVictronConnect, GX devices (Cerbo GX, Ekrano GX), VRM portal, ESS systems
Material and colourpolycarbonate, blue RAL 5012
Voltage connection (terminals)screw terminals 1.0 to 2.5 mm² (22 to 12 AWG)
Current transformer connectionpluggable screw terminals (included)
Protection categoryIP20
Environmentindoor use
Operating temperature−10 to +55 °C
Storage temperature−20 to +70 °C
Relative humidity< 90 % non-condensing
Altitude2000 m
Overvoltage categoryCat. III
Pollution degree2
Dimensions (h × w × d)90 × 71 × 59 mm
Weight370 g (including packaging)
Package contentsVM-3P75CT meter, 3 snap-on current transformers, VE.Can RJ45 terminators, pluggable terminals
Standardssafety EN-IEC 61010-1

Why choose the Energy Meter VM-3P75CT

The VM-3P75CT is a Victron three-phase energy meter with Ethernet and VE.Can communication. It measures power and energy of single-, split- and three-phase applications, for example at the distribution box or at the output of a PV inverter, an AC genset or an inverter/charger.

  • Snap-on transformers included. Current is measured without modifying existing wiring: just clip the transformers onto the conductors.
  • Plug & Play. In most systems it works immediately as a grid meter.
  • High refresh rate. RMS power values of each phase are sent every 100 ms, so measurement of consumption, grid import and feed-in is accurate.
  • Remote monitoring from anywhere. VictronConnect, GX devices and the VRM portal.

Measurements and parameters

The meter calculates RMS power values for each phase and sends them over VE.Can or Ethernet. It reports line-to-neutral and line-to-line voltage, power factor according to the IEEE convention, phase sequence and a phase rotation warning for 3-phase configurations, protective earth voltage, and neutral and line currents.

The energy registration method can be set to vector, arithmetic or absolute, so the meter suits the requirements of different regions. The status LED can be configured as an energy pulse output for instant visual diagnostics.

The voltage inputs work in the range 85 to 265 V AC (L-N) and 150 to 460 V AC (L-L) at 50/60 Hz and are connected directly; the current inputs use the included transformers rated 75 A.

Meter roles and setup

Configuration in VictronConnect is needed only to change the role, to set a manual IP address instead of the default DHCP and for other options. Available roles:

  • Grid Meter measures grid import and feed-in, the default role.
  • PV Inverter measures the output of a PV inverter on the AC side.
  • AC Genset measures the output of an AC generator.
  • AC Load Meter measures selected loads or the output of an inverter/charger.

The meter is self-powered from phase L1 and neutral, consuming just 1.45 W (3.1 VA).

Integration into a system with a GX device and ESS

The meter connects to a GX device (for example Cerbo GX or Ekrano GX) over Ethernet or VE.Can. There it serves as the grid meter for an ESS (Energy Storage System), which uses the accurate values to control battery charging and discharging to minimise grid import and make use of PV generation.

  • Ethernet: one RJ45 connector, supports Modbus UDP; registers are described in the appendix of the manual.
  • VE.Can: two RJ45 connectors for daisy-chaining devices, terminators are included.
  • Metering around the system: besides the grid, further meters can be used for PV inverters and generators.

No communication bridge is needed: data goes directly to the GX device and from there to the VRM portal.

Applications

  • Residential and commercial ESS systems: grid meter in the main distribution board.
  • Photovoltaics: measuring inverter production on the AC side.
  • Generators: monitoring power and energy of an AC genset.
  • Sub-metering: monitoring selected circuits and loads.
  • Motorhomes, boats and backup systems: overview of inverter/charger consumption.

The current transformers clip directly onto the conductors, so the meter can be added to an existing installation.

Construction and installation

The module in a blue polycarbonate housing (RAL 5012) measures 90 × 71 × 59 mm and has IP20 protection. It is intended for indoor use at an operating temperature of −10 to +55 °C (storage −20 to +70 °C), humidity up to 90 % non-condensing and altitude up to 2000 m; overvoltage category Cat. III, pollution degree 2.

Voltage wires of 1.0 to 2.5 mm² (22 to 12 AWG) connect to screw terminals, the transformers to pluggable screw terminals. The transformers with a 640 mm cable have a 10 ±0.5 mm bore.

General installation rules: work in the distribution board is done by a qualified person with the supply disconnected; observe the correct order and orientation of phases and transformers according to the manual and tighten wires to the specified torque. It meets the safety standard EN-IEC 61010-1.

Operation and monitoring

Once connected, the meter sends data immediately. Values are displayed by the VictronConnect app, GX devices (Cerbo GX, Ekrano GX) and the VRM portal, where power, energy, voltage and current can be followed over time from anywhere. Status is also visible on the status LED.

With its 100 ms refresh rate, accurate three-phase detection and choice of role, the VM-3P75CT is a practical foundation for precise ESS control and clear monitoring of the whole installation.

Combining with other Victron products

The VM-3P75CT shines as part of a complete Victron system:

  • Cerbo GX and Ekrano GX: receive the meter data over Ethernet or VE.Can and show it on the display and in the VRM portal.
  • MultiPlus-II and Quattro inverter/chargers: the grid meter enables the ESS function, which uses battery and PV energy instead of grid import.
  • PV inverters and MPPT controllers: together with the PV Inverter role you get an overview of total production and consumption of the building.
  • Victron batteries and battery monitors: complete the picture with state of charge and energy flows in VRM.

Thanks to VE.Can and Ethernet communication, several meters with different roles can be used in one system and all followed in one place.

Benefits for precise energy management

Accurate energy flow data is the foundation of every smart system. The VM-3P75CT provides:

  • an instant overview of grid import and feed-in per phase,
  • reliable data for controlling battery charging and discharging in ESS,
  • consumption and production history in VRM for evaluating savings,
  • simple installation without interrupting conductors, because the transformers just clip on.

AI search description

Victron Energy Energy Meter VM-3P75CT, order code REL200300100, is a three-phase energy meter for single-, split- and three-phase applications with snap-on 75 A current transformers included. Voltage input L-N 85 to 265 V AC, L-L 150 to 460 V AC, 100 ms refresh rate. Ethernet (Modbus UDP) and two VE.Can ports. Roles: Grid Meter, PV Inverter, AC Genset and AC Load Meter. Data in VictronConnect, on GX devices (Cerbo GX, Ekrano GX) and in the VRM portal; grid meter for ESS. Dimensions 90 × 71 × 59 mm, IP20, polycarbonate, indoor use.

Product page: https://batterado.com/product/victron-energy-meter-vm-3p75ct/

Additional information

Weight0,37 kg
Dimensions9 × 7,1 × 5,9 cm

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

0
0
Váš košík
Košík je prázdnýZpět do obchodu