Description
Technical specifications
| Manufacturer | Solis / Ginlong Technologies |
|---|---|
| Model | S5-GR3P15K |
| Type and role | Three-phase grid-connected PV inverter |
| Offered configuration | Standard model with 2 MPPTs and DC switch |
| Operating configuration | PV array and three-phase utility grid |
| Recommended maximum PV power | 22500 Wp |
| Maximum DC voltage | 1100 V |
| Rated DC voltage | 600 V |
| Start-up voltage | 180 V |
| MPPT range | 160–1000 V |
| Maximum input current MPPT 1 / 2 | 32 / 32 A |
| Maximum short-circuit current MPPT 1 / 2 | 40 / 40 A |
| Independent MPPT count | 2 |
| Maximum PV string count | 4 |
| Strings on MPPT 1 / 2 | 2 / 2 |
| Rated AC power | 15000 W |
| Maximum AC power | 16500 W |
| Maximum apparent AC power | 16500 VA |
| Grid conductors | 3 / N / PE |
| Rated grid voltage | 220 / 380 V; 230 / 400 V |
| Rated frequency | 50 / 60 Hz |
| Operating frequency | 45–55 / 55–65 Hz |
| Rated current at 380/400 V | 22.8 / 21.7 A |
| Maximum AC current | 23.8 A |
| Power factor | >0.99; adjustable 0.8 leading to 0.8 lagging |
| THDi | <2 % |
| Maximum efficiency | 98.6 % |
| European efficiency | 98.0 % |
| Topology | Transformerless |
| Night consumption | <1 W |
| DC polarity protection | Integrated function |
| Short-circuit protection | Integrated function |
| AC overcurrent protection | Integrated function |
| Surge protection | Integrated function |
| Grid monitoring | Integrated function |
| Anti-islanding protection | Integrated function |
| Temperature protection | Integrated function |
| Multi-peak MPPT scanning | Integrated function |
| DC switch | Integrated function |
| AFCI 2.0 arc protection | Optional configuration |
| DC connectors | MC4 |
| AC connector | Quick connector L1 / L2 / L3 / N / PE |
| Communication | RS485; DO / DI |
| Communication connectors | RS485 COM, CT/Meter, DRM; RJ45 and terminal connections according to manual |
| Digital meter | DTSD1352-C / DTSD1352 |
| Direct metering | DTSD1352-C, up to 80 A |
| Transformer metering | DTSD1352-C; 150 A / 5 A CT |
| Meter — communication terminals | 21 A / 22 B → two-pin inverter connector |
| Remote monitoring | Optional Wi-Fi / GPRS data logger and Solis monitoring |
| Inverter monitoring address | 01–99; default 01 |
| LCD display | 2 lines × 20 characters |
| Controls | ESC / UP / DOWN / ENTER |
| LED indicators | POWER / OPERATION / ALARM |
| Displayed operating data | PV and phase voltages/currents, power, frequency, energy, status, serial number and version |
| Generation history | Daily, monthly and yearly energy |
| Alarm / warning history | Latest 100 records in each history |
|---|---|
| Export control | Internal EPM; Meter in Load / Meter in Grid / Consumption Monitor |
| Permitted-export setting range | 0–29,900 W; output according to model rating and connection |
| Export-limit modes | 01 average / 02 according to lowest-loaded phase |
| 24-hour consumption monitoring | Grid-side meter, 24H Switch and Solis monitoring |
| Meter failsafe | Configurable alarm and generation stop on metering loss |
| External EPM | 5G-EPM / Others-EPM according to actual device |
| Active and reactive power control | Power settings and PF Curve |
| DRM — logic interface | RJ45: pin 5 Switch_input1 / pin 6 Switch_input2 |
| DRM — response after opening | Limit to 0 W within 5 s when enabled according to grid profile |
| Service updates | HMI / DSP |
| User-Def — grid-profile use | Service configuration with grid-operator permission; L–N ranges per manual |
| User-Def — overvoltage OV-G-V1 / V2 | 220–374 V; 0.01–300 s |
| User-Def — undervoltage UN-G-V1 / V2 | 110–277 V; 0.01–300 s |
| User-Def — overfrequency OV-G-F1 / F2 | 50.1–65 Hz; 0.01–300 s |
| User-Def — underfrequency UN-G-F1 / F2 | 45–59.9 Hz; 0.01–300 s |
| User-Def — Startup-T / Restore-T | 10–600 s / 10–600 s |
| Dimensions W × H × D | 310 × 563 × 219 mm |
| Weight | 19.6 kg |
| Ingress protection | IP66 |
| Operating temperature | −25 to +60 °C |
| Relative operating humidity | 0–100 % RH |
| Cooling | Intelligent fan cooling |
| Typical noise | <60 dB(A) |
| Maximum altitude | 4000 m |
| Storage temperature | −40 to +70 °C |
| Storage humidity | 0–95 % RH, non-condensing |
| Stacking packaged units | Maximum 3 units high |
| Mounting position | Vertical ±5° or backward tilt up to 15° |
| Airflow clearance | 500 mm above, at the sides and above floor; 1000 mm in front as illustrated |
| Mounting structure | Firm fire-resistant wall with airflow |
| Mounting — anchors in manual | ST6.3 × 60; HJ0108 10 × 50 mm; Ø10 × 60 mm drilling |
| Opening for own security lock | Ø5 mm |
| External earthing | Copper conductor ≥6 mm², M6 lug, 3 Nm |
| DC cable | 4–6 mm²; recommended 4 mm², PV1-F |
| DC — stripping length | 7 mm |
| DC — connector torque | 2.5–3 Nm |
| AC cable | 6–16 mm² |
| AC — cable outer diameter | 13–25 mm |
| AC — sheath / PE / conductor stripping | 70 / 70 / 9 mm; other conductors 60 mm |
| AC — terminal torque | 1.8–2.0 Nm |
| AC — swivel-nut torque | 3–4 Nm |
| AC — maximum cable resistance per manual | <1.5 Ω |
| Recommended AC breaker | 32 A |
| AC — cross-section beyond 20 m | 10–16 mm² |
| AC — sealing rings | Thick 12–18 mm / thin 16–21 mm according to cable |
| Package — inverter / bracket | 1 / 1 |
| Package — fastening screws | 2 |
| Package — DC connectors | 4 |
| Package — AC / RJ45 / manual | 1 / 1 / 1 |
| Optional system components | Digital meter, Wi-Fi/GPRS logger, external EPM and security lock according to design |
| Safety | IEC / EN 62109-1 / -2 |
| EMC | IEC / EN 61000-6-1 / -2 / -3 / -4 |
| Grid standards | G99; VDE-AR-N 4105 / VDE V 0124; EN 50549-1; VDE 0126 / UTE C 15 / VFR:2019; RD 1699 / RD 244 / UNE 206006 / UNE 206007-1; CEI 0-21; C10/11; NRS 097-2-1; EIFS 2018.2; IEC 62116 / 61727 / 60068 / 61683; EN 50530 |
| Estimated delivery | 2–3 days |
Own electricity for a three-phase supply
S5-GR3P15K uses module energy for normal grid-connected operation in a home, workshop or smaller business. Its 15000 W rating describes conversion power; daily kWh depend on irradiation, orientation and array size. Operation requires a PV array and connected utility grid. Local loads use generation directly at the supply point.
Two MPPTs for array design
Two independent trackers follow separate string groups. This model accepts up to 4 strings, two per MPPT. Operating current is limited to 32 A and short-circuit current to 40 A per tracker. Recommended maximum array power is 22500 Wp, start-up voltage 180 V, MPPT range 160–1000 V and maximum DC voltage 1100 V. Design compares actual module currents and open-circuit voltage at the local minimum temperature.
Output, phases and efficiency
The datasheet specifies 15000 W rated output, 16500 W maximum AC output and 16500 VA apparent power. Connection is 3/N/PE at 220/380 or 230/400 V, 50/60 Hz. Maximum efficiency is 98.6 %, European efficiency 98.0 % and THDi below 2 %. Adjustable power factor supports the actual grid requirements at the supply point.
Three-phase metering and export
The optional DTSD1352-C measures energy flow directly up to 80 A or through matching 150 A/5 A transformers. The manual also abbreviates the model to DTSD1352. A two-pin communication connector links the meter; its communication terminals are 21 A and 22 B. Export management supports grid-side or load-side metering. Select the actual meter and version as installation components.
Power control for the connection
Internal EPM configures permitted export and metering mode. Mode 01 uses average three-phase consumption; mode 02 bases limiting on the lowest-loaded phase. Configurable failsafe can report lost metering and stop generation. External EPM uses 5G-EPM or Others-EPM according to the actual device. Commissioning verifies flow direction and response.
Monitoring and generation overview
The LCD shows voltage, current, power, frequency, energy and operating state. Separate views track daily, monthly and yearly generation; diagnosis retains the latest 100 alarms and 100 warnings. An optional Wi-Fi or GPRS logger connects the system to monitoring. A 24-hour consumption overview uses a grid-side meter, enabled 24H Switch and configured Solis monitoring. Inverter addresses for shared monitoring range from 01 to 99.
Construction and operating environment
The 310 × 563 × 219 mm enclosure weighs 19.6 kg. The model uses intelligent fan cooling; typical noise is below 60 dB(A). IP66 is complemented by a −25 to +60 °C operating range, 0–100 % humidity and altitude up to 4000 m. A suitable indoor or outdoor location provides airflow and shelter from direct sun and rain.
Mounting and model-specific connections
Mount on a firm fire-resistant structure with appropriate clearance. The manual allows vertical mounting within ±5° or backward tilt up to 15°. The AC connector distinguishes L1, L2, L3, N and PE; the external earthing point uses an M6 lug and copper conductor of at least 6 mm². DC uses MC4 and 4–6 mm² conductors. Exact AC cross-section, torques and recommended breaker for this variant are listed in the technical overview.
Protection and logic control
Integrated functions cover DC polarity, short circuit, AC overcurrent, surge, grid monitoring, anti-islanding and temperature protection. The current datasheet lists AFCI 2.0 as optional. DRM uses RJ45 pins 5 and 6; when enabled, opening the contact allows output reduction to 0 W within five seconds according to the grid profile. Active power, reactive power and PF Curve settings match the actual connection.
Supplied inverter and system components
The standard package includes the inverter, backplate, two fastening screws, 4 DC connectors, one AC connector, one RJ45 connector and manual. This offer includes the DC switch. Select PV modules, meter, logger, wiring, protection and mounting accessories for the whole plant design. Any energy storage is provided by a separately designed compatible battery system with an appropriate converter.
Design around generation and consumption
Selection combines PV output, string voltage and current, available three-phase grid connection and the local consumption profile. Required energy in kWh is assessed separately from instantaneous kW. The Batterado product enquiry helps match system components. For storage the manual specifies −40 to +70 °C and 0–95 % non-condensing humidity; packaged units may be stacked up to three high.
Downloads
- Solis S5-GR3P — datasheet V3.8
- Solis S5-GR3P 15-20 kW — user manual
- Complete product overview — Markdown
AI search description
Three-phase solar generation for homes and smaller businesses. Solis S5-GR3P15K supplies 15 kW rated output and accepts up to 22.5 kWp of PV through two independent MPPTs. It connects up to 4 strings with 32 A per tracker and a 160–1000 V MPPT range. IP66, intelligent fan cooling, efficiency up to 98.6 % and a weight of 19.6 kg complement the compact enclosure. An optional DTSD1352-C meter enables export management and, with suitable monitoring, a 24-hour consumption overview. The offer supplies the specified inverter with DC switch and standard connection components. S5-GR3P15K uses module energy for normal grid-connected operation in a home, workshop or smaller business. Its 15000 W rating describes conversion power; daily kWh depend on irradiation, orientation and array size. Operation requires a PV array and connected utility grid. Local loads use generation directly at the supply point. The standard package includes the inverter, backplate, two fastening screws, 4 DC connectors, one AC connector, one RJ45 connector and manual. This offer includes the DC switch. Select PV modules, meter, logger, wiring, protection and mounting accessories for the whole plant design. Any energy storage is provided by a separately designed compatible battery system with an appropriate converter.
Manufacturer: Solis / Ginlong Technologies; Model: S5-GR3P15K; Type and role: Three-phase grid-connected PV inverter; Offered configuration: Standard model with 2 MPPTs and DC switch; Operating configuration: PV array and three-phase utility grid; Recommended maximum PV power: 22500 Wp; Maximum DC voltage: 1100 V; Rated DC voltage: 600 V; Start-up voltage: 180 V; MPPT range: 160–1000 V; Maximum input current MPPT 1 / 2: 32 / 32 A; Maximum short-circuit current MPPT 1 / 2: 40 / 40 A; Independent MPPT count: 2; Maximum PV string count: 4; Strings on MPPT 1 / 2: 2 / 2; Rated AC power: 15000 W; Maximum AC power: 16500 W; Maximum apparent AC power: 16500 VA; Grid conductors: 3 / N / PE; Rated grid voltage: 220 / 380 V; 230 / 400 V; Rated frequency: 50 / 60 Hz; Operating frequency: 45–55 / 55–65 Hz; Rated current at 380/400 V: 22.8 / 21.7 A; Maximum AC current: 23.8 A; Power factor: >0.99; adjustable 0.8 leading to 0.8 lagging; THDi: <2 %; Maximum efficiency: 98.6 %; European efficiency: 98.0 %; Topology: Transformerless; Night consumption: <1 W; DC polarity protection: Integrated function; Short-circuit protection: Integrated function; AC overcurrent protection: Integrated function; Surge protection: Integrated function; Grid monitoring: Integrated function; Anti-islanding protection: Integrated function; Temperature protection: Integrated function; Multi-peak MPPT scanning: Integrated function; DC switch: Integrated function; AFCI 2.0 arc protection: Optional configuration; DC connectors: MC4; AC connector: Quick connector L1 / L2 / L3 / N / PE; Communication: RS485; DO / DI; Communication connectors: RS485 COM, CT/Meter, DRM; RJ45 and terminal connections according to manual; Digital meter: DTSD1352-C / DTSD1352; Direct metering: DTSD1352-C, up to 80 A; Transformer metering: DTSD1352-C; 150 A / 5 A CT; Meter — communication terminals: 21 A / 22 B → two-pin inverter connector; Remote monitoring: Optional Wi-Fi / GPRS data logger and Solis monitoring; Inverter monitoring address: 01–99; default 01.
LCD display: 2 lines × 20 characters; Controls: ESC / UP / DOWN / ENTER; LED indicators: POWER / OPERATION / ALARM; Displayed operating data: PV and phase voltages/currents, power, frequency, energy, status, serial number and version; Generation history: Daily, monthly and yearly energy; Alarm / warning history: Latest 100 records in each history; Export control: Internal EPM; Meter in Load / Meter in Grid / Consumption Monitor; Permitted-export setting range: 0–29,900 W; output according to model rating and connection; Export-limit modes: 01 average / 02 according to lowest-loaded phase; 24-hour consumption monitoring: Grid-side meter, 24H Switch and Solis monitoring; Meter failsafe: Configurable alarm and generation stop on metering loss; External EPM: 5G-EPM / Others-EPM according to actual device; Active and reactive power control: Power settings and PF Curve; DRM — logic interface: RJ45: pin 5 Switch_input1 / pin 6 Switch_input2; DRM — response after opening: Limit to 0 W within 5 s when enabled according to grid profile; Service updates: HMI / DSP; User-Def — grid-profile use: Service configuration with grid-operator permission; L–N ranges per manual; User-Def — overvoltage OV-G-V1 / V2: 220–374 V; 0.01–300 s; User-Def — undervoltage UN-G-V1 / V2: 110–277 V; 0.01–300 s; User-Def — overfrequency OV-G-F1 / F2: 50.1–65 Hz; 0.01–300 s; User-Def — underfrequency UN-G-F1 / F2: 45–59.9 Hz; 0.01–300 s; User-Def — Startup-T / Restore-T: 10–600 s / 10–600 s; Dimensions W × H × D: 310 × 563 × 219 mm; Weight: 19.6 kg; Ingress protection: IP66; Operating temperature: −25 to +60 °C; Relative operating humidity: 0–100 % RH; Cooling: Intelligent fan cooling; Typical noise: <60 dB(A); Maximum altitude: 4000 m; Storage temperature: −40 to +70 °C; Storage humidity: 0–95 % RH, non-condensing; Stacking packaged units: Maximum 3 units high; Mounting position: Vertical ±5° or backward tilt up to 15°; Airflow clearance: 500 mm above, at the sides and above floor; 1000 mm in front as illustrated; Mounting structure: Firm fire-resistant wall with airflow; Mounting — anchors in manual: ST6.3 × 60; HJ0108 10 × 50 mm; Ø10 × 60 mm drilling; Opening for own security lock: Ø5 mm; External earthing: Copper conductor ≥6 mm², M6 lug, 3 Nm; DC cable: 4–6 mm²; recommended 4 mm², PV1-F; DC — stripping length: 7 mm; DC — connector torque: 2.5–3 Nm; AC cable: 6–16 mm²; AC — cable outer diameter: 13–25 mm; AC — sheath / PE / conductor stripping: 70 / 70 / 9 mm; other conductors 60 mm; AC — terminal torque: 1.8–2.0 Nm; AC — swivel-nut torque: 3–4 Nm; AC — maximum cable resistance per manual: <1.5 Ω; Recommended AC breaker: 32 A; AC — cross-section beyond 20 m: 10–16 mm²; AC — sealing rings: Thick 12–18 mm / thin 16–21 mm according to cable; Package — inverter / bracket: 1 / 1; Package — fastening screws: 2; Package — DC connectors: 4; Package — AC / RJ45 / manual: 1 / 1 / 1; Optional system components: Digital meter, Wi-Fi/GPRS logger, external EPM and security lock according to design; Safety: IEC / EN 62109-1 / -2; EMC: IEC / EN 61000-6-1 / -2 / -3 / -4; Grid standards: G99; VDE-AR-N 4105 / VDE V 0124; EN 50549-1; VDE 0126 / UTE C 15 / VFR:2019; RD 1699 / RD 244 / UNE 206006 / UNE 206007-1; CEI 0-21; C10/11; NRS 097-2-1; EIFS 2018.2; IEC 62116 / 61727 / 60068 / 61683; EN 50530; Estimated delivery: 2–3 days.













Reviews
There are no reviews yet.