Description
Technical specifications
| Manufacturer | Solis / Ginlong Technologies |
|---|---|
| Model | S5-GC36K |
| Type and role | Three-phase grid-connected PV inverter |
| Offered configuration | Standard model with 4 MPPTs and DC switch |
| Operating configuration | PV array and three-phase utility grid |
| Recommended maximum PV power | 54000 Wp |
| Maximum DC voltage | 1100 V |
| Rated DC voltage | 600 V |
| Start-up voltage | 180 V |
| MPPT range | 200–1000 V |
| Maximum input current per MPPT | 32 A / MPPT |
| Maximum short-circuit current per MPPT | 40 A / MPPT |
| Independent MPPT count | 4 |
| Maximum PV string count | 8 |
| Strings per MPPT | 2 / MPPT |
| Rated AC power | 36000 W |
| Maximum AC power | 39600 W |
| Maximum apparent AC power | 39600 VA |
| Grid conductors | 3 / N / PE |
| Rated grid voltage | 220 / 380 V; 230 / 400 V |
| Rated frequency | 50 / 60 Hz |
| Rated current at 380/400 V | 54.7 / 52 A |
| Maximum AC current | 60.2 A |
| Power factor | >0.99; adjustable 0.8 leading to 0.8 lagging |
| THDi | <3 % |
| Maximum efficiency | 98.7 % |
| European efficiency | 98.3 % |
| Topology | Transformerless |
| Night consumption | <1 W |
| DC polarity protection | Integrated function |
| Short-circuit protection | Integrated function |
| AC overcurrent protection | Integrated function |
| Surge protection | DC Type II / AC Type II |
| Grid monitoring | Integrated function |
| Anti-islanding protection | Integrated function |
| Temperature protection | Integrated function |
| Multi-peak MPPT scanning | Integrated function |
| DC switch | Integrated function |
| AFCI 2.0 arc protection | Optional configuration |
| DC connectors | MC4 |
| AC terminal connection | OT-lug terminal block; L1 / L2 / L3 / N / PE |
| Communication | RS485 |
| Communication connectors | RS485 input/output, two-pin Meter and RJ45 DRM per manual |
| RS485 — IN / OUT terminals | 1 A1 IN (+); 2 B1 IN (−); 3 A2 OUT (+); 4 B2 OUT (−) |
| RS485 — conductor / cable diameter | 0.2–1.5 mm² / 5–10 mm |
| RS485 — sheath / conductor stripping | 30 / 8 mm |
| Digital meter | DTSD1352 |
| Direct metering | DTSD1352, up to 80 A |
| Transformer metering | DTSD1352; 150 A / 5 A CT |
| Meter — communication terminals | 21 A / 22 B → two-pin inverter connector |
| Remote monitoring | Optional Wi-Fi / GPRS data logger and Solis monitoring |
| Inverter monitoring address | 01–99; default 01 |
| LCD display | 2 lines × 20 characters |
| Controls | ESC / UP / DOWN / ENTER |
| LED indicators | POWER / OPERATION / ALARM |
| Displayed operating data | PV and phase voltages/currents, power, frequency, energy, status, serial number and version |
| Generation history | Daily, monthly and yearly energy |
| Alarm / warning history | Latest 100 records in each history |
| Export control | Internal EPM; Meter in Load / Meter in Grid / Consumption Monitor |
|---|---|
| Permitted-export setting range | 0–29,900 W in Internal EPM menu |
| Export-limit modes | 01 average / 02 according to lowest-loaded phase |
| 24-hour consumption monitoring | Grid-side meter, 24H Switch and Solis monitoring |
| Meter failsafe | Configurable alarm and generation stop on metering loss |
| External EPM | 5G-EPM / Others-EPM according to actual device |
| Active and reactive power control | Power settings and PF Curve |
| DRM — logic interface | RJ45: pin 5 Switch_input1 / pin 6 Switch_input2 |
| DRM — response after opening | Limit to 0 W within 5 s when enabled according to grid profile |
| Service updates | HMI / DSP |
| String monitoring | Integrated |
| PID recovery | Optional configuration |
| I/V curve scanning | Integrated function |
| I/V scan — start / step / points | 300–1000 V / 1–100 V / 60 |
| Grid check at start-up | 30–300 s |
| Service fan test | Fan Test |
| User-Def — grid-profile use | Service configuration with grid-operator permission; L–N ranges per manual |
| User-Def — overvoltage OV-G-V1 / V2 | 220–374 V; 0.01–300 s |
| User-Def — undervoltage UN-G-V1 / V2 | 110–277 V; 0.01–300 s |
| User-Def — overfrequency OV-G-F1 / F2 | 50.1–65 Hz; 0.01–300 s |
| User-Def — underfrequency UN-G-F1 / F2 | 45–59.9 Hz; 0.01–300 s |
| User-Def — Startup-T / Restore-T | 10–600 s / 10–600 s |
| Dimensions W × H × D | 647 × 629 × 252 mm |
| Weight | 42.1 kg |
| Ingress protection | IP66 |
| Operating temperature | −25 to +60 °C |
| Relative operating humidity | 0–100 % RH |
| Cooling | Intelligent fan cooling |
| Typical noise | ≤60 dB(A) |
| Maximum altitude | 4000 m |
| Storage temperature | −40 to +70 °C |
| Storage humidity | 0–95 % RH, non-condensing |
| Stacking packaged units | Maximum 3 units high |
| Mounting position | Vertical or backward tilt up to 15° |
| Airflow clearance | 500 mm above, at the sides and above floor; 1000 mm in front as illustrated |
| Mounting structure | Firm fire-resistant wall with airflow |
| Mounting — anchors in manual | M10 × 70; drill Ø10 mm, depth 60 mm |
| Handling and lifting points | Two people; two top holes for suitable lifting equipment |
| External earthing | Copper conductor ≥16 mm², M6 lug, 3–4 Nm |
| DC cable | 4–6 mm²; recommended 4 mm², PV1-F |
| DC — stripping length | 7 mm |
| DC — connector torque | 3–4 Nm |
| AC cable | 10–35 mm²; recommended 25 mm² |
| AC — cable outer diameter | 22–32 mm; recommended 27 mm |
| AC — sheath and conductor stripping | Sheath 80 mm; conductors according to OT-lug crimp length (S2 = S1) |
| AC — terminal torque | 3–4 Nm |
| AC — maximum cable resistance per manual | <1.5 Ω |
| Recommended AC breaker | 80 A |
| Package — inverter / bracket | 1 / 1 |
| Package — cross / hex screws | 4 + 2 |
| Package — DC connectors | 8 |
| Package — AC terminal cover / RJ45 / manual | 1 / 1 / 1 |
| Optional system components | DTSD1352 meter, Wi-Fi/GPRS logger and external EPM according to design |
| Safety | IEC / EN 62109-1 / -2 |
| EMC | IEC / EN 61000-6-1 / -2 / -3 / -4 |
| Grid standards | G99; VDE-AR-N 4105 / VDE V 0124; EN 50549-1; VDE 0126 / UTE C 15 / VFR:2019; RD 1699 / RD 244 / UNE 206006 / UNE 206007-1; CEI 0-21; C10/11; NRS 097-2-1; EIFS 2018.2; IEC 62116 / 61727 / 60068 / 61683; EN 50530 |
| Estimated delivery | 2–3 days |
Solar generation for larger loads
S5-GC36K delivers PV energy to the three-phase supply point of a business, commercial site or larger building. Its 36 kW rating describes instantaneous conversion power; kWh generation depends on irradiation, orientation and array size. The operating system consists of modules, inverter and connected utility grid. Generation serves local loads according to their consumption profile.
Independent MPPTs for module groups
4 independent trackers follow separate string groups. Each accepts two strings, giving 8 overall. Each tracker supports 32 A maximum input current and 40 A short-circuit current. Recommended array power reaches 54000 Wp; MPPT operates at 200–1000 V, start-up begins at 180 V and maximum DC voltage is 1100 V. Design compares actual module currents and cold-weather open-circuit voltage.
Output and efficient conversion
The datasheet specifies 36000 W rated output, 39600 W maximum AC output and 39600 VA maximum apparent power. The 3/N/PE connection uses 220/380 or 230/400 V at 50/60 Hz. Maximum efficiency is 98.7 % and European efficiency 98.3 %. THDi is below 3 %; power factor above 0.99 is adjustable from 0.8 leading to 0.8 lagging for grid requirements. Transformerless construction has night consumption below 1 W.
Metering and self-consumption
The optional three-phase DTSD1352 measures directly up to 80 A or, in its CT version, through matching 150 A/5 A transformers. Meter terminals 21 A and 22 B connect to the inverter’s two-pin connector. Export management supports grid-side or load-side metering. A 24-hour consumption view uses a grid-side meter, enabled 24H Switch and Solis monitoring. Select the actual meter version for the installation.
Output and export management
Internal EPM offers Meter in Load, Meter in Grid and Consumption Monitor. Mode 01 uses average three-phase consumption; mode 02 follows the lowest-loaded phase. The permitted-export menu spans 0–29,900 W. Configurable failsafe can report metering loss and stop generation. External control uses 5G-EPM or Others-EPM according to the device. Commissioning verifies metering direction and system response.
Monitoring and linking inverters
The LCD and LEDs show operation, output, voltages, currents and energy. Daily, monthly and yearly production history and the latest 100 alarms and 100 warnings are available. RS485 supports daisy chaining: A1/B1 input and A2/B2 output, with addresses 01–99 and default 01. An optional Wi-Fi/GPRS logger links a suitably designed system to remote monitoring. Communication wiring, conductor sizes and stripping lengths appear in the technical overview and manual.
Strings and I/V diagnostics
Integrated string monitoring and I/V curve scanning provide insight into individual PV branches. Service scanning sets a 300–1000 V starting voltage and 1–100 V step and uses 60 data points. Multi-peak MPPT scanning supports operating-point tracking. Service menus include fan testing and HMI/DSP updates; the supplied manual contains the complete procedures.
Construction and environment
The 647 × 629 × 252 mm enclosure weighs 42.1 kg. IP66 provides dust-tight construction and protection against powerful water jets; a suitable location supports indoor or outdoor mounting. Intelligent fan cooling accompanies a −25 to +60 °C operating range, 0–100 % humidity and altitude up to 4000 m. Datasheet typical noise is at most 60 dB(A). The mounting site provides airflow and shelter from direct sun and rain.
Mounting and power connections
A firm fire-resistant structure supports vertical mounting or backward tilt up to 15°. The manual shows 500 mm around the enclosure and above floor and 1000 mm in front. Two people or appropriate lifting equipment at the top points handle the unit. MC4 DC connectors use 4–6 mm² conductors. The OT-lug AC terminal block accepts 10–35 mm², with 25 mm² recommended. External earthing uses at least 16 mm² copper and an M6 lug. This model’s recommended AC breaker is 80 A; torques and cable preparation appear in the technical overview.
Protection and available configurations
Standard protection covers DC polarity, short circuit, AC overcurrent, grid monitoring, anti-islanding and temperature. Surge protection is Type II on both DC and AC sides. The datasheet lists AFCI 2.0 and PID recovery as optional configurations. DRM uses RJ45 pins 5 and 6; with the feature enabled under the grid profile, opening the contact limits output to 0 W within five seconds. Active and reactive power, PF Curve and grid profile are configured for the actual connection.
Supply and complete plant design
The standard package contains the inverter, backplate, four cross screws, two hex screws, 8 DC connectors, AC terminal cover, RJ45 connector and manual. The offer includes the DC switch. Modules, meter, logger, protection and mounting components are selected for the plant. Energy in kWh and power in kW are assessed separately; any storage uses a separately designed compatible battery system with an appropriate converter. Batterado helps match related products. Storage conditions are −40 to +70 °C and 0–95 % non-condensing humidity, with up to three packaged units stacked.
Downloads
- Solis S5-GC 25–40 kW — datasheet V3.8
- Solis S5-GC — EUR user manual V1.3
- Complete product overview — Markdown
AI search description
High-output three-phase solar generation for businesses, workshops and larger properties. Solis S5-GC36K converts module energy at 36 kW rated output and supports up to 54 kWp of PV. Its 4 independent MPPTs accept 8 strings, two per tracker, at up to 32 A per MPPT. IP66, intelligent cooling and a −25 to +60 °C operating range support suitable indoor and outdoor locations. Up to 98.7 % efficiency, string monitoring and I/V curve scanning provide an informed view of production. An optional DTSD1352 meter adds export management; suitable Solis monitoring provides a 24-hour consumption overview. This offer includes the DC switch and standard connection components. S5-GC36K delivers PV energy to the three-phase supply point of a business, commercial site or larger building. Its 36 kW rating describes instantaneous conversion power; kWh generation depends on irradiation, orientation and array size. The operating system consists of modules, inverter and connected utility grid. Generation serves local loads according to their consumption profile. The standard package contains the inverter, backplate, four cross screws, two hex screws, 8 DC connectors, AC terminal cover, RJ45 connector and manual. The offer includes the DC switch. Modules, meter, logger, protection and mounting components are selected for the plant. Energy in kWh and power in kW are assessed separately; any storage uses a separately designed compatible battery system with an appropriate converter. Batterado helps match related products. Storage conditions are −40 to +70 °C and 0–95 % non-condensing humidity, with up to three packaged units stacked.
Manufacturer: Solis / Ginlong Technologies; Model: S5-GC36K; Type and role: Three-phase grid-connected PV inverter; Offered configuration: Standard model with 4 MPPTs and DC switch; Operating configuration: PV array and three-phase utility grid; Recommended maximum PV power: 54000 Wp; Maximum DC voltage: 1100 V; Rated DC voltage: 600 V; Start-up voltage: 180 V; MPPT range: 200–1000 V; Maximum input current per MPPT: 32 A / MPPT; Maximum short-circuit current per MPPT: 40 A / MPPT; Independent MPPT count: 4; Maximum PV string count: 8; Strings per MPPT: 2 / MPPT; Rated AC power: 36000 W; Maximum AC power: 39600 W; Maximum apparent AC power: 39600 VA; Grid conductors: 3 / N / PE; Rated grid voltage: 220 / 380 V; 230 / 400 V; Rated frequency: 50 / 60 Hz; Rated current at 380/400 V: 54.7 / 52 A; Maximum AC current: 60.2 A; Power factor: >0.99; adjustable 0.8 leading to 0.8 lagging; THDi: <3 %; Maximum efficiency: 98.7 %; European efficiency: 98.3 %; Topology: Transformerless; Night consumption: <1 W; DC polarity protection: Integrated function; Short-circuit protection: Integrated function; AC overcurrent protection: Integrated function; Surge protection: DC Type II / AC Type II; Grid monitoring: Integrated function; Anti-islanding protection: Integrated function; Temperature protection: Integrated function; Multi-peak MPPT scanning: Integrated function; DC switch: Integrated function; AFCI 2.0 arc protection: Optional configuration; DC connectors: MC4; AC terminal connection: OT-lug terminal block; L1 / L2 / L3 / N / PE; Communication: RS485; Communication connectors: RS485 input/output, two-pin Meter and RJ45 DRM per manual; RS485 — IN / OUT terminals: 1 A1 IN (+); 2 B1 IN (−); 3 A2 OUT (+); 4 B2 OUT (−); RS485 — conductor / cable diameter: 0.2–1.5 mm² / 5–10 mm; RS485 — sheath / conductor stripping: 30 / 8 mm; Digital meter: DTSD1352; Direct metering: DTSD1352, up to 80 A; Transformer metering: DTSD1352; 150 A / 5 A CT; Meter — communication terminals: 21 A / 22 B → two-pin inverter connector; Remote monitoring: Optional Wi-Fi / GPRS data logger and Solis monitoring; Inverter monitoring address: 01–99; default 01; LCD display: 2 lines × 20 characters; Controls: ESC / UP / DOWN / ENTER; LED indicators: POWER / OPERATION / ALARM.
Displayed operating data: PV and phase voltages/currents, power, frequency, energy, status, serial number and version; Generation history: Daily, monthly and yearly energy; Alarm / warning history: Latest 100 records in each history; Export control: Internal EPM; Meter in Load / Meter in Grid / Consumption Monitor; Permitted-export setting range: 0–29,900 W in Internal EPM menu; Export-limit modes: 01 average / 02 according to lowest-loaded phase; 24-hour consumption monitoring: Grid-side meter, 24H Switch and Solis monitoring; Meter failsafe: Configurable alarm and generation stop on metering loss; External EPM: 5G-EPM / Others-EPM according to actual device; Active and reactive power control: Power settings and PF Curve; DRM — logic interface: RJ45: pin 5 Switch_input1 / pin 6 Switch_input2; DRM — response after opening: Limit to 0 W within 5 s when enabled according to grid profile; Service updates: HMI / DSP; String monitoring: Integrated; PID recovery: Optional configuration; I/V curve scanning: Integrated function; I/V scan — start / step / points: 300–1000 V / 1–100 V / 60; Grid check at start-up: 30–300 s; Service fan test: Fan Test; User-Def — grid-profile use: Service configuration with grid-operator permission; L–N ranges per manual; User-Def — overvoltage OV-G-V1 / V2: 220–374 V; 0.01–300 s; User-Def — undervoltage UN-G-V1 / V2: 110–277 V; 0.01–300 s; User-Def — overfrequency OV-G-F1 / F2: 50.1–65 Hz; 0.01–300 s; User-Def — underfrequency UN-G-F1 / F2: 45–59.9 Hz; 0.01–300 s; User-Def — Startup-T / Restore-T: 10–600 s / 10–600 s; Dimensions W × H × D: 647 × 629 × 252 mm; Weight: 42.1 kg; Ingress protection: IP66; Operating temperature: −25 to +60 °C; Relative operating humidity: 0–100 % RH; Cooling: Intelligent fan cooling; Typical noise: ≤60 dB(A); Maximum altitude: 4000 m; Storage temperature: −40 to +70 °C; Storage humidity: 0–95 % RH, non-condensing; Stacking packaged units: Maximum 3 units high; Mounting position: Vertical or backward tilt up to 15°; Airflow clearance: 500 mm above, at the sides and above floor; 1000 mm in front as illustrated; Mounting structure: Firm fire-resistant wall with airflow; Mounting — anchors in manual: M10 × 70; drill Ø10 mm, depth 60 mm; Handling and lifting points: Two people; two top holes for suitable lifting equipment; External earthing: Copper conductor ≥16 mm², M6 lug, 3–4 Nm; DC cable: 4–6 mm²; recommended 4 mm², PV1-F; DC — stripping length: 7 mm; DC — connector torque: 3–4 Nm; AC cable: 10–35 mm²; recommended 25 mm²; AC — cable outer diameter: 22–32 mm; recommended 27 mm; AC — sheath and conductor stripping: Sheath 80 mm; conductors according to OT-lug crimp length (S2 = S1); AC — terminal torque: 3–4 Nm; AC — maximum cable resistance per manual: <1.5 Ω; Recommended AC breaker: 80 A; Package — inverter / bracket: 1 / 1; Package — cross / hex screws: 4 + 2; Package — DC connectors: 8; Package — AC terminal cover / RJ45 / manual: 1 / 1 / 1; Optional system components: DTSD1352 meter, Wi-Fi/GPRS logger and external EPM according to design; Safety: IEC / EN 62109-1 / -2; EMC: IEC / EN 61000-6-1 / -2 / -3 / -4; Grid standards: G99; VDE-AR-N 4105 / VDE V 0124; EN 50549-1; VDE 0126 / UTE C 15 / VFR:2019; RD 1699 / RD 244 / UNE 206006 / UNE 206007-1; CEI 0-21; C10/11; NRS 097-2-1; EIFS 2018.2; IEC 62116 / 61727 / 60068 / 61683; EN 50530; Estimated delivery: 2–3 days.