Description
Technical data
| Brand | Victron Energy |
|---|---|
| Model | MultiPlus-II 48/6k5/100-50 230V |
| Order code | PMP482605012 |
| Type | Inverter/charger with transfer switch |
| Nominal battery voltage | 48 V |
| Inverter: DC input voltage range | 38–60 V |
| Inverter: AC output voltage | 230 V ± 2 % |
| Inverter: output frequency | 50 Hz ± 0.1 % (adjustable to 60 Hz) |
| Inverter: continuous power at 25 °C | 6 kW |
| Inverter: continuous power at 40 °C | 5.7 kW |
| Inverter: continuous power at 65 °C | 4.6 kW |
| Inverter: time-limited power 1 (cold start) | 6.5 kW / 4 h |
| Inverter: time-limited power 2 (cold start) | 8 kW / 1 h |
| Inverter: max. apparent feed-in power | 6 kW |
| Inverter: peak power | 11 kW / 1 min |
| Inverter: max. efficiency | 96 % |
| Inverter: zero load power | 28 W |
| Inverter: zero load power in AES mode | 18 W |
| Inverter: zero load power in Search mode | 8 W |
| Switchover time to inverter (main output) | less than 20 ms |
| AC input: voltage range | 187–265 V |
| AC input: frequency range | 45–65 Hz |
| AC input: max. input current | 50 A |
| Transfer switch | 50 A |
| PowerControl and PowerAssist | yes |
| External AC current sensor (optional) | 100 A (100 A:50 mA) |
| Auxiliary AC output (AC-out-2) | yes (50 A) |
| Charger: absorption voltage | 57.6 V |
| Charger: float voltage | 55.2 V |
| Charger: storage mode voltage | 52.8 V |
| Charger: max. battery charge current at 25 °C | 100 A |
|---|---|
| Charger: max. battery charge current at 40 °C | 95 A |
| Charger: compatible battery types | lithium, lead-acid, zinc-bromine and more (other chemistries are possible if the charger is configured according to the battery manufacturer’s specification) |
| Battery temperature sensor | optional; order number ASS000001000 |
| Protection | output short circuit, overload, battery voltage too high, battery voltage too low, temperature too high, 230 V AC on inverter output, input voltage ripple too high |
| Anti-islanding protection | built-in function |
| Battery connection | M8 bolts |
| AC connection | screw terminals 13 mm² (6 AWG) |
| VE.Bus port | yes (parallel and three-phase operation, remote monitoring and system integration) |
| General purpose communication port | yes, 2× |
| Remote on/off terminal | yes |
| Programmable relay | yes (general alarm, DC undervoltage or genset start/stop; AC 230 V / 4 A, DC 4 A up to 35 V DC and 1 A up to 60 V DC) |
| VE.Bus protocol | connection of units in parallel and three-phase operation, remote monitoring and system integration; the MK3-USB interface connects via RJ45 UTP cable |
| Configuration and remote control | VictronConnect app, VEConfigure software (with MK3-USB interface), VRM portal |
| Compatibility: GX devices | GX devices Cerbo GX, Ekrano GX and other GX products |
| Compatibility: solar systems | solar charge controllers (MPPT) and grid-tie PV inverters |
| Compatibility: monitoring and control | VRM portal, VictronConnect with VE.Bus Smart dongle (Bluetooth), Battery Monitor, Digital Multi Control Panel |
| Parallel operation | up to 6 units |
| Three-phase operation | 3 units of the same model, up to 6 sets in parallel |
| Operating temperature range | −40 to +65 °C (fan-assisted cooling) |
| Humidity (non-condensing) | max. 95 % |
| Maximum altitude | 4000 m (power derating of 1 % per 100 m above 2000 m) |
| Material and colour | steel, blue RAL 5012 |
| Protection category | IP21 |
| Dimensions (h × w × d) | 644 × 320 × 150 mm |
| Weight | 29 kg |
| Standards: safety | EN-IEC 60335-1, EN-IEC 60335-2-29, EN-IEC 62109-1, EN-IEC 62109-2 |
| Standards: emission and immunity (EMC) | EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3, IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3 |
| Standards: uninterruptible power supply (UPS) | IEC 62040 |
| Standards: anti-islanding | IEC 62116 |
Powerful inverter/charger for large 48 V systems
The Victron Energy MultiPlus-II 48/6k5/100-50 230V is a multifunctional inverter/charger with transfer switch for a 48 V battery. Continuous power is 6 kW at 25 °C, peak power reaches 11 kW for 1 minute and efficiency is up to 96 %. The DC input range is 38–60 V and the output is 230 V ± 2 % at 50 Hz (adjustable to 60 Hz).
This model is meant for installations where a small inverter is not enough: larger houses, workshops, boats and vehicles, as well as off-grid and back-up systems. It has all the features of the classic MultiPlus plus an optional external current sensor that extends PowerControl and PowerAssist to 100 A. Anti-islanding protection is built in.
Power, time-limited loads and temperature
Continuous power drops only moderately with ambient temperature: 6 kW at 25 °C, 5.7 kW at 40 °C and 4.6 kW at 65 °C. Beyond that the inverter handles time-limited power of 6.5 kW for 4 hours and 8 kW for 1 hour (cold start), and a peak of 11 kW for 1 minute. Maximum apparent feed-in power is 6 kW. Cooling is fan-assisted, the operating range is −40 to +65 °C, and no derating is needed up to 2000 m altitude; above that, power is reduced by 1 % per 100 m up to 4000 m.
Zero load power is 28 W, 18 W in AES mode and 8 W in Search mode. For continuous operation at low load, the economy modes are worth using.
100 A charger and choosing a 48 V battery
The charger delivers up to 100 A at 25 °C ambient and 95 A at 40 °C. The absorption voltage is 57.6 V, float 55.2 V and storage mode 52.8 V. The AC input range is 187–265 V at 45–65 Hz. The charger works with lithium, lead-acid and zinc-bromine batteries and more; other chemistries are possible if the charger is set according to the battery manufacturer’s specification. The battery temperature sensor is optional (order number ASS000001000).
With a charge current of 100 A, choose a 48 V battery that can accept it, and size the cabling for the inverter currents. The battery is connected with M8 bolts.
Suitable battery chemistries are lithium, lead-acid, zinc-bromine and others; other chemistries are possible according to the battery manufacturer’s specification. The DC input voltage range is 38–60 V. When sizing the battery, allow for a charge current of up to 100 A and for the short-term draw during the 11 kW peak.
PowerControl, PowerAssist and 50 A input
The PowerControl function sets a maximum grid or generator current; the inverter then uses only what remains after the other loads for charging. PowerAssist tops up insufficient generator, shore or grid power from the battery and recharges it once the load drops. Unlike the smaller models in the range, this model handles an AC input current and transfer switch rating of 50 A.
The main output has no break: if the grid fails or the generator is disconnected, the inverter takes over the supply in less than 20 ms, so computers and electronics keep running.
Two AC outputs with a 50 A auxiliary output
The main output supplies critical loads and is backed up from the battery during an outage. The second output AC-out-2 (up to 50 A) is live only when AC is present on the input. It suits loads that should not discharge the battery, such as a water heater or an air conditioner.
Loads on the second output are taken into account by PowerControl and PowerAssist, so the AC input current stays at a safe value.
Solar systems, ESS and grid-parallel topology
The MultiPlus-II can be used in off-grid and grid-connected systems with photovoltaics. It is compatible with solar charge controllers and grid-tie PV inverters, so AC power is available even during a grid failure.
In a grid-parallel topology with an MPPT controller, the inverter takes data from the external AC current sensor (100 A, ordered separately) or a power meter, optimises self-consumption and, if required, prevents grid feed-in. In an outage it keeps supplying the critical loads. ESS system design is described in the Victron ESS Design and configuration manual.
Parallel and three-phase operation
Up to 6 units can be connected in parallel. Six 48/6k5/100-50 units give a continuous output of 36 kW and a charge current of 600 A. Three units of the same model can be configured for three-phase output, and up to six such sets of three can be paralleled.
The units are linked through the VE.Bus port with UTP cables with RJ45 connectors; configuration is done in VEConfigure software with the MK3-USB interface.
Switching between grid and battery takes less than 20 ms, so most sensitive loads do not notice an outage. With six units in parallel the system reaches 36 kW continuous power and 600 A charge current; the same model can therefore serve a small home installation as well as a large off-grid one.
Communication, monitoring and configuration
The inverter communicates over the VE.Bus. A GX device such as the Cerbo GX or Ekrano GX provides local and remote monitoring and access to the free VRM portal: data is displayed graphically, settings can be changed remotely, alarms arrive by e-mail or push notification, and the VRM app is available for iOS and Android.
Settings can be changed in minutes with VEConfigure software (a computer and the MK3-USB interface) or in the VictronConnect app. Further options are Bluetooth with the VE.Bus Smart dongle (which also measures battery voltage and temperature), a Battery Monitor and the Digital Multi Control Panel. The unit has two general purpose communication ports, a remote on/off terminal and a programmable relay (alarm, DC undervoltage or genset start/stop).
Installation, construction and standards
The blue steel enclosure (RAL 5012) has IP21 protection and weighs 29 kg. Dimensions (h × w × d) are 644 × 320 × 150 mm. Humidity is up to 95 % non-condensing. The battery is connected with M8 bolts; AC wiring goes to screw terminals for 13 mm² (6 AWG).
The unit conforms to EN-IEC 60335-1, EN-IEC 60335-2-29, EN-IEC 62109-1 and EN-IEC 62109-2 (safety), EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3, IEC 61000-6-1, IEC 61000-6-2 and IEC 61000-6-3 (EMC), IEC 62040 (uninterruptible power supply) and IEC 62116 (anti-islanding).
AI search description
The Victron Energy MultiPlus-II 48/6k5/100-50 230V (order code PMP482605012) is an inverter/charger with transfer switch for a 48 V battery (DC 38–60 V). Continuous power 6 kW at 25 °C, 4.6 kW at 65 °C, peak 11 kW for 1 minute, time-limited 6.5 kW for 4 h and 8 kW for 1 h, efficiency up to 96 %, switchover under 20 ms. 100 A charger, 50 A AC input and transfer switch, 50 A auxiliary output, PowerControl and PowerAssist. VE.Bus communication, GX devices, VRM and VictronConnect. Up to 6 units in parallel or three-phase. IP21, 29 kg, 644 × 320 × 150 mm. Use: large off-grid, back-up and hybrid systems.
Product page: https://batterado.com/product/victron-multiplus-ii-48-6500-100-50/













Reviews
There are no reviews yet.