Store energy. Every way.™

Helping with technology for more than 25 years.More than 25 years on the market

Victron Energy MultiPlus-II 48/5000/70-50 Inverter/Charger 5 kVA 48 V

24 700 Kč incl. VAT

Seller: Tomorrow Systems® s.r.o.

5 kVA inverter/charger for a 48 V battery: the Victron Energy MultiPlus-II 48/5000/70-50 delivers a peak power of 9,000 W and switches to battery operation in under 20 ms when the grid fails.

  • Continuous power 5,000 VA (4,000 W at 25 °C), efficiency up to 96 %.
  • 70 A charger for lead-acid and lithium batteries, DC voltage 38–66 V.
  • PowerControl and PowerAssist: tops up grid or generator power from the battery, 50 A AC input.
  • Two AC outputs: uninterrupted and auxiliary (up to 50 A).
  • VE.Bus communication, up to 6 units in parallel, 3 units three-phase; monitoring via GX devices and VRM.

The steel unit has IP22 protection, measures 565 × 320 × 149 mm and weighs 30 kg. It suits off-grid, back-up and hybrid systems with photovoltaics and a 48 V battery, as well as marine and mobile use.

In stock

Enquiry

Description

Technical data

BrandVictron Energy
ModelMultiPlus-II 48/5000/70-50 230V
Order codePMP482505012
TypeInverter/charger with transfer switch
Nominal battery voltage48 V
Inverter: DC input voltage range38–66 V
Inverter: AC output voltage230 V ± 2 %
Inverter: output frequency50 Hz ± 0.1 % (adjustable to 60 Hz)
Inverter: continuous power at 25 °C (non-linear load, crest factor 3:1)5,000 VA
Inverter: continuous power at 25 °C4,000 W
Inverter: continuous power at 40 °C3,700 W
Inverter: continuous power at 65 °C3,000 W
Inverter: peak power9,000 W
Inverter: max. apparent feed-in power5,000 VA
Inverter: max. efficiency96 %
Inverter: zero load power18 W
Inverter: zero load power in AES mode12 W
Inverter: zero load power in Search mode2 W
Switchover time to inverter (main output AC-out-1)less than 20 ms
AC input: voltage range187–265 V
AC input: frequency range45–65 Hz
AC input: max. input current50 A
Transfer switch50 A
PowerControl and PowerAssistyes
External AC current sensor (optional)100 A (100 A:50 mA)
Auxiliary AC output (AC-out-2)yes (50 A)
Charger: absorption voltage57.6 V
Charger: float voltage55.2 V
Charger: storage mode voltage52.8 V
Charger: max. battery charge current (up to 25 °C ambient)70 A
Charger: compatible battery typeslead-acid, lithium, zinc-bromine and others (other chemistries only with the charger set to the battery manufacturer’s specifications)
Battery temperature sensoroptional, not included with 48 V models; order number ASS000001000
Protectionoutput short circuit, overload, battery voltage too high, battery voltage too low, temperature too high, 230 V AC on inverter output, input voltage ripple too high
Anti-islanding protectionbuilt-in function
Battery connectionfour M8 bolts (2 plus and 2 minus connections)
AC connectionscrew terminals 13 mm² (6 AWG)
VE.Bus portyes (parallel and three-phase operation, remote monitoring and system integration)
General purpose communication portyes, 2×
Remote on/off terminalyes
Programmable relayyes (general alarm, DC undervoltage or genset start/stop; AC 230 V / 4 A, DC 4 A up to 35 V DC and 1 A up to 60 V DC)
VE.Bus protocolcommunication with GX devices, control panel, MK3-USB interface and between units in parallel and three-phase operation (UTP cables with RJ45 connectors)
Ports Aux 1 and Aux 2 (analogue/digital inputs/outputs)e.g. communication with the BMS of a lithium-ion battery
Configuration and remote controlVictronConnect app, VEConfigure software (with MK3-USB interface), VRM portal
Compatibility: GX devicesGX devices Cerbo GX and Ekrano GX
Compatibility: Victron Lithium Smart batteriesvia VE.Bus BMS V2 or Lynx Smart BMS
Compatibility: other lithium batteriesaccording to the list of compatible Victron battery types and others
Compatibility: solar systemssolar charge controllers (MPPT) and grid-tie (AC) PV inverters
Compatibility: monitoring and controlVRM portal, VictronConnect with VE.Bus Smart dongle (Bluetooth), Battery Monitor, Digital Multi Control Panel
Parallel operationup to 6 units (6× 48/5000/70: 25 kW / 30 kVA, 420 A charging capacity)
Three-phase operation3 units of the same model, up to 6 sets in parallel (75 kW / 90 kVA, more than 1,200 A charging)
Operating temperature range−40 to +65 °C (fan-assisted cooling)
Humidity (non-condensing)max. 95 %
Maximum altitude2000 m
Material and coloursteel, blue RAL 5012
Protection categoryIP22
Dimensions (h × w × d)565 × 320 × 149 mm
Weight30 kg
Standards: safetyEN-IEC 60335-1, EN-IEC 60335-2-29, EN-IEC 62109-1, EN-IEC 62109-2
Standards: emission and immunity (EMC)EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3, IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3

5 kVA inverter/charger for a 48 V battery

The Victron Energy MultiPlus-II 48/5000/70-50 230V is a multifunctional inverter/charger that combines a powerful sine-wave inverter, a battery charger and an AC transfer switch in one enclosure. Its rated power is 5,000 VA (4,000 W at 25 °C), peak power reaches 9,000 W and maximum efficiency is 96 %. The unit works with a battery of 48 V nominal voltage; the DC input voltage range is 38–66 V and the output is 230 V ± 2 % at 50 Hz, with the frequency adjustable to 60 Hz.

Compared with the classic MultiPlus, the MultiPlus-II offers an optional external current sensor that extends PowerControl and PowerAssist to an input current of 50 A or 100 A. It is well suited to professional marine, yachting, vehicle and land-based off-grid applications, and has built-in anti-islanding protection and a growing list of country approvals for ESS applications.

Inverter: power, temperature derating and peaks

Continuous power depends on the ambient temperature: 4,000 W at 25 °C, 3,700 W at 40 °C and 3,000 W at 65 °C. The 5,000 VA figure applies at 25 °C for a non-linear load with a crest factor of 3:1. When feeding into the grid, the maximum apparent power is 5,000 VA. The peak power of 9,000 W is available for short-term demands from loads with a high inrush current.

Zero load power is 18 W, 12 W in AES mode and only 2 W in Search mode. AES mode reduces consumption at low loads by slightly narrowing the sine wave and is used in stand-alone systems; in Search mode the inverter switches off when there is no load and switches on briefly at intervals to detect whether a load has been connected. Cooling is fan-assisted and the operating temperature range is −40 to +65 °C.

Battery charger and battery selection

The charger delivers a current of up to 70 A (at ambient temperatures up to 25 °C) and uses an adaptive four-stage algorithm: bulk – absorption – float – storage. The absorption voltage is 57.6 V, float 55.2 V and storage mode 52.8 V. Adaptive control adjusts the absorption time according to how deeply the battery was discharged, and BatterySafe mode limits gassing at high charge currents. The battery temperature sensor is optional (order number ASS000001000) and is not included with 48 V models.

Lead-acid, lithium and zinc-bromine batteries and others are compatible; other chemistries are possible if the charger is set according to the battery manufacturer’s specifications. With Victron Lithium Smart batteries, use the VE.Bus BMS V2 or the Lynx Smart BMS. For other lithium batteries, refer to the list of compatible Victron battery types; the programmable ports Aux 1 and Aux 2 can be used for communication with the BMS of a lithium-ion battery. The list is not exhaustive and more batteries are compatible.

PowerControl, PowerAssist and uninterrupted supply

The PowerControl function lets you set a maximum grid or generator current. The inverter then takes the other AC loads into account and uses only the remaining current for battery charging, so the source is not overloaded. PowerAssist goes a step further: where peak power is needed only briefly, the inverter compensates insufficient grid, shore or generator power with power from the battery, and when the load drops, the spare power is used to recharge the battery. The maximum AC input current and the transfer switch rating are 50 A; the optional 100 A external current sensor (100 A:50 mA) extends PowerControl and PowerAssist in grid-parallel topologies.

If the grid fails or the generator is disconnected, the inverter takes over the main output in less than 20 ms, so computers and other electronic equipment continue to operate without disruption.

Two AC outputs: uninterrupted and auxiliary

The main output AC-out-1 has no break functionality and supplies critical loads. The second, auxiliary output AC-out-2 (up to 50 A) is live only when grid or generator power is present on the AC input. It is meant for loads that should not discharge the battery, such as a water heater or an air conditioner. When the unit switches to battery operation, the load on AC-out-2 is disconnected immediately, and once AC power returns to the input it is reconnected after a delay of about 2 minutes so the generator can stabilise. Loads on AC-out-2 are taken into account by PowerControl and PowerAssist, so the AC input current stays within safe limits.

Solar energy and ESS systems

The MultiPlus-II can be used in off-grid as well as grid-connected systems with photovoltaics and other alternative energy sources. It is compatible with DC solar charge controllers and with AC PV inverters, so AC power remains available even during a grid failure. When PV inverters are connected to the inverter output, surplus solar energy is used to recharge the batteries; once the absorption voltage is reached, the charge current is reduced and the surplus is fed back into the grid. If the grid is not available, the inverter slightly raises the AC frequency to reduce the output of the PV inverter (frequency shift).

In a grid-parallel topology the inverter uses data from the external AC current sensor (ordered separately) or from a power meter to optimise self-consumption and, if required, to prevent grid feed-in; in a power outage it continues to supply the critical loads. In an ESS (Energy Storage System) in which the inverter feeds energy back into the grid, the country grid code setting is selected in VEConfigure; once set, a password is required to change grid-code parameters. Depending on the grid code, several reactive power control modes are available: fixed cos φ, cos φ as a function of power P, fixed Q and Q as a function of input voltage.

Parallel and three-phase operation

Up to 6 units can be operated in parallel: six 48/5000/70 units provide 25 kW / 30 kVA of output power with 420 A charging capacity. In addition to parallel connection, three units of the same model can be configured for three-phase output, and up to 6 sets of three units can be connected in parallel for 75 kW / 90 kVA and more than 1,200 A charging capacity.

For parallel and three-phase operation, all units must be identical and connected to the same battery, and the DC cables must have the same length and cross-section. The units are interconnected with UTP (RJ45) cables, directly from one unit to the next. The system is then configured in VEConfigure.

Communication, monitoring and configuration

The inverter communicates over the VE.Bus with GX devices, a control panel and other units. A Cerbo GX or Ekrano GX can be added for local and remote connection. Operational data is stored and displayed free of charge on the VRM (Victron Remote Management) portal; once connected to the internet, the system can be controlled and configured remotely, alarms can be received by e-mail or push notification, and the VRM app is available for iOS and Android.

Settings can be changed in a matter of minutes with the VEConfigure software (MK3-USB interface needed), in the VictronConnect app or via the VRM portal. Further monitoring and control options: the VictronConnect app over Bluetooth with the VE.Bus Smart dongle (which also measures battery voltage and temperature), a Battery Monitor, or the Digital Multi Control Panel with an on/off/charger-only switch, LED readout and a rotary knob for setting PowerControl and PowerAssist levels. The unit has two general purpose communication ports, a remote on/off terminal and a programmable relay (alarm, DC undervoltage or genset start/stop).

Installation, construction and standards

The inverter is housed in a blue steel enclosure (RAL 5012) with IP22 protection. It should be installed in a dry, well-ventilated area, as close as possible to the batteries. Dimensions (h × w × d) are 565 × 320 × 149 mm and the weight is 30 kg. The battery is connected with four M8 bolts (2 plus and 2 minus connections); AC wiring is connected to screw terminals for conductors up to 13 mm² (6 AWG). The maximum altitude is 2000 m and humidity up to 95 % non-condensing.

The unit conforms to EN-IEC 60335-1, EN-IEC 60335-2-29, EN-IEC 62109-1 and EN-IEC 62109-2 (safety) and EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3, IEC 61000-6-1, IEC 61000-6-2 and IEC 61000-6-3 (emission and immunity).

AI search description

The Victron Energy MultiPlus-II 48/5000/70-50 230V (order code PMP482505012) is an inverter/charger with transfer switch for a 48 V battery (DC 38–66 V). Continuous power 5,000 VA, 4,000 W at 25 °C, peak 9,000 W, efficiency up to 96 %, switchover under 20 ms. Charger up to 70 A, PowerControl and PowerAssist, 50 A AC input, two AC outputs (auxiliary up to 50 A). VE.Bus communication, compatible GX devices Cerbo GX and Ekrano GX, VRM and VictronConnect monitoring, lead-acid and lithium batteries. IP22, 30 kg. Use: off-grid, back-up and hybrid systems with photovoltaics.

Product page: https://batterado.com/product/victron-multiplus-ii-48-5000-70-50/

Additional information

Weight30 kg
Dimensions56,5 × 32,0 × 14,9 cm

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.