Solis S6-EH3P15K-H AFCI 1.0 — 15 kW hybrid inverter, 4 MPPTs, 7″ LCD

46 786 Kč incl. VAT

Ask about this product

15 kW for PV, self-consumption and battery backup. Four 20 A MPPTs, a 120–800 V HV battery and clear 7″ LCD connect generation, storage and consumption. Select the Smart port role for generator, AC coupling or managed loads according to system design. The offer includes DC switch, Wi-Fi/LAN, 7″ LCD and meter; DC/AC Type II SPD and AFCI 1.0.

Available on back-order

Description

Technical specifications

Manufacturer Solis / Ginlong Technologies
Manufacturer model S6-EH3P15K-H
Offered configuration DC switch, Wi-Fi/LAN, 7″ LCD and meter; DC/AC Type II SPD and AFCI 1.0
Device type Three-phase hybrid inverter for PV and HV battery
Rated AC output 15000 W
Maximum AC apparent output 15000 VA
Rated backup output 15000 W
Peak backup output / duration 24000 VA /10 s
Single-unit transfer <10 ms
Output per phase 6000 W
MPPT /string count 4 /4
Input current per MPPT 20 A
Short-circuit current per MPPT 30 A
Recommended PV array rating 30 kWp
Maximum usable PV power 24 kW
Maximum DC voltage 1000 V
Rated DC voltage 600 V
Start-up voltage 160 V
MPPT range 200–850 V
Full-load MPPT range 300–850 V
Battery type Compatible HV Li-ion system with BMS
Battery voltage 120–800 V
Maximum charge /discharge current 50 /50 A
Maximum charge /discharge power 15 /15 kW
Battery — 120 V reference point 25 A
Battery — 200 V reference point 50 A
Battery — full-output reference 300 V /50 A
Battery port /BMS port 1 /1
Storage capacity In kWh according to selected battery system
Battery matching Exact model, module count, voltage, BMS, firmware and current capability
Battery communication CAN /RS485
Grid connection 3/N/PE; 220/380 V; 230/400 V
Grid frequency 50 /60 Hz
Rated AC current at 380/400 V 22.8 /21.7 A
Maximum AC input power 22.5 kW
Maximum AC input current at 380/400 V 34.2 /32.5 A
AC input voltage 304–437 /320–460 V
AC input frequency 45–55 /55–65 Hz
Power factor >0.99; 0.8 leading /lagging
THDi <3 %
THDv linear load <3 %
Generator — maximum input power 15 kW
Generator — current at 380/400 V 22.8 /21.7 A
Generator — connection Three-phase, GEN port or designed Grid/ATS arrangement
Maximum efficiency 97.7 %
European efficiency 97.5 %
PV →battery efficiency 98.5 %
Battery ↔AC efficiency 97.2 %
MPPT efficiency 99.9 %
User interface 7.0″ LCD /Bluetooth /SolisCloud APP
Keys ESC /UP /DOWN /ENTER
Status LEDs POWER /OPERATION /ALARM
App roles Installer /Owner
Operating modes Self Use /Selling First /Off Grid /Peak Shaving
Grid charging Allow Grid Charging
Time scheduling 6 charging and 6 discharging windows
Backup reserve 5–95 % SOC; default 80 %
Default over-discharge /force-charge SOC 20 /10 %
Default maximum charge 100 % SOC
SOC setting order Force Charge <Over-discharge <Recovery
Export measurement calibration −500…+500 W; default 20 W
Peak Shaving Pmax /Peak SOC
Battery Saving /ECO Grid standby supply according to SOC and PV power
Battery Wakeup Manual/automatic wake-up from PV or grid according to battery
Wake-up — voltage 120–600 V; default 120 V
Wake-up — time 20–300 s; default 180 s
Wake-up — current Up to 6 A according to battery
Battery Healing Controlled recovery to selected SOC
Smart port — function selection Genset input /AC coupled /Smart load output
Smart load — power allocation Backup +Smart load ≤15 kW
Smart load — control ON/OFF SOC; On-grid always on; Off-grid always off
AC coupling — existing PV inverter 3-phase ≤15 kW; Freq-Watt according to design
AC coupling — control Max Export Control; Export Power /SOC
Dual meters Grid 001 /PV inverter 002
Included standard meter Eastron SDM630MCT
Standard CTs 3 ×ESCT-TA16; 120 A /40 mA
Metering above 3 parallel units SDM630MCT V2 +ESCT-T50; 300 A /5 A
CT orientation Arrow towards grid
Reference CT ratio 3000; according to actual CTs
BMS CAN RJ45 4 CAN-H /5 CAN-L
BMS RS485 RJ45 3 B /6 A
Meter RJ45 1 A /2 B
Eastron terminals 13 B /14 A
External RS485 Modbus RTU 1 A /2 B
Communication glands COM1 /COM2; 6 mm
Parallel system 2–6 identical models, each with its own battery and BMS
Parallel connection PAR-B →PAR-A; shielded CAT5; ≤5 m
Parallel-system addresses Master 1; Slave 2–6
Parallel bus termination Both DIPs ON at first and last unit according to diagram
GEN — start contact 1 /2; voltage-free
Generator at Grid — DI signal 5 +5/12 VDC /6 GND; external 220 VAC →5/12 VDC converter
Heat pump — signal SG Ready; 11 /12
Heat pump — modes Manual /Smart
Heat pump — default ON/OFF SOC 90 /70 %
Heat pump — default ON/OFF power 2000 /−500 W
Heat pump — minimum runtime 5–60 min; default 10 min; step 5 min
DRM — remote shutdown RJ45 5 /6; open shuts down within 5 s
DRM — power steps S1–S4: 0 /30 /60 /100 %
DRM mode2 — default S4 import 4.2 kW
PV conductors 4–6 mm²; recommended 4 mm²
PV stripping 7 ±0.5 mm
Recommended battery conductor 8 AWG /8.37 mm²
Battery fuse 1000 V /100 A
Reference battery protection 2-pole 63 A; according to design
AC Grid conductors 6–10 mm²
AC Backup /GEN conductors 4–10 mm²
PE conductor 10 mm²
AC stripping 13 mm
AC terminals /glands 4–5 Nm
External earth M4 /2 Nm
Reference AC protection 4-pole 63 A; according to design
Mounting Vertical wall mounting, up to ±5°
Mounting clearance /front access 300 /500 mm
Bracket hole spacing 289 ×175 mm
Dimensions W ×H ×D 563 ×546 ×250 mm
Weight 35.2 kg
Ingress protection IP66
Operating temperature −25…+60 °C
Operating humidity 0–100 % RH
Altitude 2000 m
Cooling Intelligent fan cooling
Noise <65 dB(A)
Self-consumption <25 W
Package — fasteners 2 ×M4×12; 4 ×M10×70
Package — main parts Inverter, backplate, quick guide, Bluetooth antenna, logger, meter and CTs
Package — communications and PV 1 ×CAN; 1 ×meter cable; 6 ×RJ45; 4 ×PV pairs
Estimated delivery 2–3 days
Parallel-system transfer up to 6 units <20 ms
Maximum AC passthrough at 380/400 V 34.2 /32.5 A
Surge and arc equipment DC/AC Type II SPD and AFCI 1.0 included in this offer

A plant matched to your demand

Solis S6-EH3P15K-H combines a PV array, compatible HV battery and three-phase appliances in homes or smaller businesses. Rated 15 kW describes instantaneous conversion capability. Selected battery-system kWh, usable SOC and reserve determine stored energy. Runtime follows actual consumption and simultaneous loads. Batterado helps match modules, storage, metering and electrical equipment.

Four MPPTs for different roof sections

Four independent trackers connect four strings with up to 20 A input and 30 A short-circuit current per MPPT. Recommended PV array is 30 kWp and maximum usable input 24 kW. Start-up voltage is 160 V, working range 200–850 V and full-load range 300–850 V. Design uses actual module currents and string voltage at local minimum temperature within the 1000 V DC maximum.

Battery: matching voltage, power and capacity

The 120–800 V input serves a compatible high-voltage Li-ion battery with BMS. Maximum current is 50 A and power up to 15 kW according to operating point. Manual references are 120 V at 25 A, 200 V at 50 A and 300 V at 50 A for this model’s full output. Design therefore matches exact battery, module count, voltage, current limits, BMS and firmware. Required kWh follows runtime and demand. Temperature conditions are checked separately for the chosen battery.

Backup and appliance allocation across phases

Backup output provides rated 15 kW and peak 24 kVA for 10 seconds. A single inverter transfers from grid to backup in less than 10 ms. One phase delivers up to 6 kW within total output. Dedicated backup circuits use Backup and utility uses Grid. Design considers motor starting, simultaneous appliances and battery capability. Smart loads can be prioritised within a combined Backup plus Smart-load total of 15 kW.

Seven-inch display and SolisCloud

A large 7″ LCD shows energy flows and operating information on the device. Four keys ESC, UP, DOWN and ENTER complement three LEDs POWER, OPERATION and ALARM. SolisCloud supports local Bluetooth setup with Installer and Owner roles and remote information through included Wi-Fi/LAN. Initial setup covers time, meter, grid code, operating mode and battery model. HMI and app provide corresponding operating data, alarms and system settings.

Self-consumption, time tariffs and grid charging

Self Use prioritises local consumption and storage; Selling First prioritises export after supplying appliances. Off Grid supports designed independent operation. Six charging and six discharging windows schedule energy. Allow Grid Charging enables recovery at Force Charge SOC or charging when PV is insufficient during a charge window. Adjustable 5–95% SOC reserve keeps energy available for backup. Peak Shaving uses Pmax and target SOC according to system capability.

Smart port for generator, AC coupling or controlled load

Select the Smart-port role matching the system: Genset input, AC coupled or Smart load output. A three-phase generator up to 15 kW connects at GEN for backup loads or through a designed metered Grid/ATS arrangement. GEN start contact 1/2 is voltage-free; a generator at Grid uses a 5/12 VDC status DI signal on pins 5/6 with the matching external converter. AC coupling integrates a supported three-phase PV inverter up to 15 kW with configured Freq-Watt response. Smart load switches lower-priority demand according to SOC and selected rules.

Metering and exact battery communications

The offered metering configuration includes Eastron SDM630MCT and three ESCT-TA16 120 A/40 mA CTs. CT arrows point towards grid; standard ratio is 3000 and custom CTs use their actual ratio. Meter RJ45 uses pin 1 A and 2 B, Eastron 14 A and 13 B. BMS CAN is 4 H and 5 L; BMS RS485 uses 3 B and 6 A. Separate external Modbus RTU uses 1 A and 2 B. Dual meters for AC coupling distinguish Grid address 001 and PV inverter 002.

Expansion and SG Ready heat-pump control

Two to six identical models connect through PAR-B and PAR-A using shielded CAT5 up to 5 m between units. Each inverter has its own battery and BMS; Master address is 1 and other units 2–6. Both DIPs at endpoints terminate the bus according to the original diagram. More than three units use a designed SDM630MCT V2 and ESCT-T50 300 A/5 A metering kit. SG Ready heat pumps use contacts 11/12 for manual or Smart control by SOC and export; default thresholds 90/70% and 2000/−500 W complement minimum runtime 5–60 minutes.

IP66 mounting and power connections

The 563 ×546 ×250 mm enclosure weighs 35.2 kg, offers IP66 and operates from −25 to +60 °C. Intelligent fan cooling uses 300 mm clearance and 500 mm front service access. Wall-bracket spacing is 289 ×175 mm and vertical mounting allows ±5°. Manual AC Grid conductors are 6–10 mm², Backup/GEN 4–10 mm² and PE 10 mm²; AC terminals and glands use 4–5 Nm. Recommended battery conductor is 8 AWG /8.37 mm². Final cables, protection and earthing follow the actual project.

Equipment for a complete energy solution

The package includes inverter, backplate, two M4×12 screws, four M10×70 expansion bolts, four pairs of PV connectors, CAN cable, six RJ45s, Bluetooth antenna and quick guide. The offered configuration includes DC switch, Wi-Fi/LAN, 7″ LCD and meter; DC/AC Type II SPD and AFCI 1.0. Selected modules, mounting accessories, compatible HV battery system and electrical equipment complete the plant. The public technical overview, original diagrams and AI search description connect individual specifications to whole-system design.

Downloads

AI search description

Solis S6-EH3P15K-H AFCI 1.0 — 15 kW hybrid inverter, 4 MPPTs, 7″ LCD. Solis S6-EH3P15K-H combines a PV array, compatible HV battery and three-phase appliances in homes or smaller businesses. Rated 15 kW describes instantaneous conversion capability. Selected battery-system kWh, usable SOC and reserve determine stored energy. Runtime follows actual consumption and simultaneous loads. Batterado helps match modules, storage, metering and electrical equipment. The 120–800 V input serves a compatible high-voltage Li-ion battery with BMS. Maximum current is 50 A and power up to 15 kW according to operating point. Manual references are 120 V at 25 A, 200 V at 50 A and 300 V at 50 A for this model’s full output. Design therefore matches exact battery, module count, voltage, current limits, BMS and firmware. Required kWh follows runtime and demand. Temperature conditions are checked separately for the chosen battery.

Manufacturer: Solis / Ginlong Technologies; Manufacturer model: S6-EH3P15K-H; Offered configuration: DC switch, Wi-Fi/LAN, 7″ LCD and meter; DC/AC Type II SPD and AFCI 1.0; Device type: Three-phase hybrid inverter for PV and HV battery; Rated AC output: 15000 W; Maximum AC apparent output: 15000 VA; Rated backup output: 15000 W; Peak backup output / duration: 24000 VA /10 s; Single-unit transfer: <10 ms; Output per phase: 6000 W; MPPT /string count: 4 /4; Input current per MPPT: 20 A; Short-circuit current per MPPT: 30 A; Recommended PV array rating: 30 kWp; Maximum usable PV power: 24 kW; Maximum DC voltage: 1000 V; Rated DC voltage: 600 V; Start-up voltage: 160 V; MPPT range: 200–850 V; Full-load MPPT range: 300–850 V; Battery type: Compatible HV Li-ion system with BMS; Battery voltage: 120–800 V; Maximum charge /discharge current: 50 /50 A; Maximum charge /discharge power: 15 /15 kW; Battery — 120 V reference point: 25 A; Battery — 200 V reference point: 50 A; Battery — full-output reference: 300 V /50 A; Battery port /BMS port: 1 /1; Storage capacity: In kWh according to selected battery system; Battery matching: Exact model, module count, voltage, BMS, firmware and current capability; Battery communication: CAN /RS485; Grid connection: 3/N/PE; 220/380 V; 230/400 V; Grid frequency: 50 /60 Hz; Rated AC current at 380/400 V: 22.8 /21.7 A; Maximum AC input power: 22.5 kW; Maximum AC input current at 380/400 V: 34.2 /32.5 A; AC input voltage: 304–437 /320–460 V; AC input frequency: 45–55 /55–65 Hz; Power factor: >0.99; 0.8 leading /lagging; THDi: <3 %; THDv linear load: <3 %; Generator — maximum input power: 15 kW; Generator — current at 380/400 V: 22.8 /21.7 A; Generator — connection: Three-phase, GEN port or designed Grid/ATS arrangement; Maximum efficiency: 97.7 %; European efficiency: 97.5 %; PV →battery efficiency: 98.5 %; Battery ↔AC efficiency: 97.2 %; MPPT efficiency: 99.9 %; User interface: 7.0″ LCD /Bluetooth /SolisCloud APP; Keys: ESC /UP /DOWN /ENTER; Status LEDs: POWER /OPERATION /ALARM; App roles: Installer /Owner; Operating modes: Self Use /Selling First /Off Grid /Peak Shaving; Grid charging: Allow Grid Charging; Time scheduling: 6 charging and 6 discharging windows; Backup reserve: 5–95 % SOC; default 80 %; Default over-discharge /force-charge SOC: 20 /10 %; Default maximum charge: 100 % SOC; SOC setting order: Force Charge <Over-discharge <Recovery; Export measurement calibration: −500…+500 W; default 20 W; Peak Shaving: Pmax /Peak SOC; Battery Saving /ECO: Grid standby supply according to SOC and PV power; Battery Wakeup: Manual/automatic wake-up from PV or grid according to battery; Wake-up — voltage: 120–600 V; default 120 V; Wake-up — time: 20–300 s; default 180 s; Wake-up — current: Up to 6 A according to battery.

Battery Healing: Controlled recovery to selected SOC; Smart port — function selection: Genset input /AC coupled /Smart load output; Smart load — power allocation: Backup +Smart load ≤15 kW; Smart load — control: ON/OFF SOC; On-grid always on; Off-grid always off; AC coupling — existing PV inverter: 3-phase ≤15 kW; Freq-Watt according to design; AC coupling — control: Max Export Control; Export Power /SOC; Dual meters: Grid 001 /PV inverter 002; Included standard meter: Eastron SDM630MCT; Standard CTs: 3 ×ESCT-TA16; 120 A /40 mA; Metering above 3 parallel units: SDM630MCT V2 +ESCT-T50; 300 A /5 A; CT orientation: Arrow towards grid; Reference CT ratio: 3000; according to actual CTs; BMS CAN RJ45: 4 CAN-H /5 CAN-L; BMS RS485 RJ45: 3 B /6 A; Meter RJ45: 1 A /2 B; Eastron terminals: 13 B /14 A; External RS485 Modbus RTU: 1 A /2 B; Communication glands: COM1 /COM2; 6 mm; Parallel system: 2–6 identical models, each with its own battery and BMS; Parallel connection: PAR-B →PAR-A; shielded CAT5; ≤5 m; Parallel-system addresses: Master 1; Slave 2–6; Parallel bus termination: Both DIPs ON at first and last unit according to diagram; GEN — start contact: 1 /2; voltage-free; Generator at Grid — DI signal: 5 +5/12 VDC /6 GND; external 220 VAC →5/12 VDC converter; Heat pump — signal: SG Ready; 11 /12; Heat pump — modes: Manual /Smart; Heat pump — default ON/OFF SOC: 90 /70 %; Heat pump — default ON/OFF power: 2000 /−500 W; Heat pump — minimum runtime: 5–60 min; default 10 min; step 5 min; DRM — remote shutdown: RJ45 5 /6; open shuts down within 5 s; DRM — power steps: S1–S4: 0 /30 /60 /100 %; DRM mode2 — default S4 import: 4.2 kW; PV conductors: 4–6 mm²; recommended 4 mm²; PV stripping: 7 ±0.5 mm; Recommended battery conductor: 8 AWG /8.37 mm²; Battery fuse: 1000 V /100 A; Reference battery protection: 2-pole 63 A; according to design; AC Grid conductors: 6–10 mm²; AC Backup /GEN conductors: 4–10 mm²; PE conductor: 10 mm²; AC stripping: 13 mm; AC terminals /glands: 4–5 Nm; External earth: M4 /2 Nm; Reference AC protection: 4-pole 63 A; according to design; Mounting: Vertical wall mounting, up to ±5°; Mounting clearance /front access: 300 /500 mm; Bracket hole spacing: 289 ×175 mm; Dimensions W ×H ×D: 563 ×546 ×250 mm; Weight: 35.2 kg; Ingress protection: IP66; Operating temperature: −25…+60 °C; Operating humidity: 0–100 % RH; Altitude: 2000 m; Cooling: Intelligent fan cooling; Noise: <65 dB(A); Self-consumption: <25 W; Package — fasteners: 2 ×M4×12; 4 ×M10×70; Package — main parts: Inverter, backplate, quick guide, Bluetooth antenna, logger, meter and CTs; Package — communications and PV: 1 ×CAN; 1 ×meter cable; 6 ×RJ45; 4 ×PV pairs; Estimated delivery: 2–3 days; Parallel-system transfer up to 6 units: <20 ms; Maximum AC passthrough at 380/400 V: 34.2 /32.5 A; Surge and arc equipment: DC/AC Type II SPD and AFCI 1.0 included in this offer.

Batterado — SOLIS-S6-EH3P15K-H-AFCI

Markdown — SOLIS-S6-EH3P15K-H-AFCI

Additional information

Weight 35,2 kg
Dimensions 25 × 56,3 × 54,6 cm