Store energy. Every way.™

Solis S6-EH3P5K-H-EU — 5 kW three-phase hybrid inverter, 3 MPPTs, HV battery

31 610 Kč incl. VAT

Ask about this product

5 kW for PV, self-consumption and battery backup. 3 MPPTs, a 120–600 V high-voltage battery and up to 25 A support a plant matched to your demand. Backup transfer below 10 ms, grid charging and scheduling complement the meter and Wi-Fi/LAN monitoring in the offered configuration.

Available on back-order

Description

Technical specifications

Manufacturer Solis / Ginlong Technologies
Manufacturer model S6-EH3P5K-H-EU
Device type Three-phase hybrid inverter for PV and HV battery
Offered equipment DC switch, Wi-Fi/LAN monitoring and meter
Rated AC output 5000 W
Maximum AC apparent output 5000 VA
Rated backup output 5000 W
Peak backup output / duration 8000 VA / 60 s
Backup transfer <10 ms
THDv linear load <2 %
Single-unit output per phase 2500 W
Single-unit imbalance 100 %
MPPT count 3
String count 3
Strings per MPPT 1
Input current per MPPT 16 A
Short-circuit current per MPPT 24 A
Recommended PV array rating 10 kWp
Maximum usable PV power 8 kW
Maximum input power per MPPT 8000 W
Maximum DC voltage 1000 V
Rated DC voltage 600 V
Start-up voltage 160 V
MPPT range 200–850 V
Full-load MPPT range 200–850 V
Battery type Compatible high-voltage Li-ion system with BMS
Battery voltage 120–600 V
Charge / discharge current 25 / 25 A
Maximum charge / discharge power 5 / 5 kW
Storage capacity In kWh according to selected battery system
Battery-system power According to actual voltage, BMS limit and inverter current
Battery communication CAN / RS485
PV → battery efficiency 98.37 %
Battery ↔ AC efficiency 97.32 %
Grid connection 3/N/PE; 380 / 400 V
Grid frequency 50 / 60 Hz
Rated AC current at 380 /400 V 7.6 / 7.2 A
Maximum AC input current at 380 /400 V 11.4 / 10.9 A
AC input voltage 304–437 / 320–460 V
AC input frequency 45–55 / 55–65 Hz
Power factor >0.99; 0.8 leading / lagging
THDi <3 %
Operating modes Self Use / Feed-in Priority / Off Grid / Peak Shaving
Grid charging Allow Grid Charging setting for schedule or SOC recovery
Time scheduling 6 charging and 6 discharging windows
Backup reserve Adjustable reserved SOC
Default over-discharge SOC 20 %
Default force-charge SOC 10 %
Peak Shaving Pmax + Peak SOC
Local control SolisCloud APP / Bluetooth
Status LEDs Battery / Power / WiFi / RS485 / Bluetooth
Bluetooth BDR / EDR / BLE; 2400–2483.5 MHz; 4 dBm
App roles Installer / Owner
Initial settings Date, time, battery model, meter, grid code and work mode
Parallel system 2–6 identical inverter models
Parallel-system batteries Each inverter has its own battery and BMS connection
Parallel grid configuration Balanced three-phase connection following manufacturer diagram
Parallel communication P-B → P-A; shielded CAT5; ≤5 m
Parallel-system addresses Master 1; Slave 2–6; Parallel Sync
Parallel bus termination At endpoints according to selected original diagram
Standard meter Eastron SDM630MCT
Standard CTs ESCT-TA16; 120 A / 40 mA
Metering above 3 parallel units SDM630MCT V2 + ESCT-T50; 300 A / 5 A
BMS CAN RJ45 4 CAN-H / 5 CAN-L; 3 m
Meter RJ45 1 A / 2 B; 5 m
Eastron terminals 13 B / 14 A
External Modbus RTU RS485 RJ45: 5 A / 4 B
CT orientation Arrow towards grid
DRM Pins 5/6 closed: operation; open: shutdown within 5 s
Grid / Backup connectors Separate grid and backup connectors
PV conductors 4–6 mm²; recommended 4 mm²
PV stripping 7 ±0.5 mm
Battery conductors 10 mm² / 8 AWG
AC conductors per manual 6 mm²; cable Ø14–17 mm
AC conductor stripping 7 mm
AC terminals / nut 0.8 ±0.1 / 2.5 ±0.5 Nm
Earth terminal M4 / 2 Nm
Communication cover 1.7–2 Nm
Communication glands 6 mm
Ingress protection IP66
Operating temperature −25…+60 °C
Operating humidity 0–100 % RH
Altitude 4000 m
Cooling Natural convection
Noise <46.9 dB(A)
Night consumption <25 W
Dimensions W × H × D 600 × 500 × 210 mm
Weight 27.6 kg
Mounting Vertical wall mounting, up to ±5°
Mounting clearances 200 mm
Bracket hole spacing 515 × 170 mm
Package — main parts Inverter, backplate, manual, dust cover, Bluetooth antenna
Package — fasteners 4 × M4 ×12
Package — metering 1 meter, 3 CTs, 1 meter cable
Package — communication 6 × RJ45; 1 × CAN cable
Package — power connectors Grid 1; Backup 1; BAT 1; PV 3
Optional family protection AFCI 2.0; DC / AC SPD Type II
Estimated delivery 2–3 days

PV, storage and backup in one system

Solis S6-EH3P5K-H-EU connects PV, a compatible high-voltage battery and three-phase loads. Rated 5 kW describes instantaneous power; selected battery kWh, usable SOC and consumption determine stored energy and runtime. Batterado matches modules, battery, metering and electrical equipment for homes or smaller businesses.

Independent trackers for PV design

3 independent MPPTs connect 3 strings, each up to 16 A input and 24 A short-circuit current. Recommended array rating is 10 kWp and usable PV input 8 kW. Start-up is 160 V, MPPT 200–850 V and full-load MPPT 200–850 V. Design considers cold-weather string voltage, the 1000 V maximum and actual module characteristics.

HV battery matched to energy and power

The 120–600 V battery input works with a compatible Li-ion system and BMS. Maximum charge and discharge current is 25 A, with up to 5 kW according to actual voltage and BMS limits. Design selects exact model, module count, voltage, firmware and communication settings. Battery capacity is selected separately in kWh. PV-to-battery efficiency reaches 98.37%. The chosen battery has its own operating-temperature specifications.

Backup circuit and load allocation

Backup output delivers rated 5 kW and briefly 8 kVA for 60 seconds. Transfer takes less than 10 ms. A single unit supports 100% imbalance and up to 2.5 kW on one phase within total output. Dedicated loads connect to Backup and utility to Grid. Design accounts for simultaneous appliances, starting peaks and battery capability.

Scheduling and grid charging

Self Use prioritises local generation use, Feed-in Priority configured export, Off Grid independent operation and Peak Shaving battery assistance at grid Pmax. Six charge and six discharge windows schedule energy. Allow Grid Charging enables charging during selected times or SOC recovery. Adjustable backup reserve keeps selected energy available. Default over-discharge SOC is 20% and force-charge SOC 10%.

Metering for energy-flow control

The offer includes a meter and Wi-Fi/LAN monitoring. Standard metering uses Eastron SDM630MCT and three ESCT-TA16 120 A/40 mA CTs with arrows towards grid. Meter RJ45 pin 1 A and 2 B connect to Eastron 14 A and 13 B; the supplied cable is 5 m. More than three parallel units use the matching SDM630MCT V2 and ESCT-T50 300 A/5 A kit according to the manual.

Bluetooth, app and communications

SolisCloud provides local Bluetooth configuration and remote information through included Wi-Fi/LAN. Installer and Owner roles expose corresponding settings and operating data. Commissioning sets time, battery, meter, grid code and mode. Five LEDs show Battery, Power, WiFi, RS485 and Bluetooth. BMS CAN uses pins 4 H and 5 L with a 3 m cable; separate external Modbus RTU uses RS485 pin 5 A and 4 B.

Expansion with two to six identical units

A parallel system connects two to six identical inverter models through P-B and P-A using recommended shielded CAT5 up to 5 m between units. Each inverter uses its own battery and BMS connection. Primary address is 1, others 2–6; configure unit count and Parallel Sync. Grid side uses a balanced three-phase design. Bus endpoint termination follows the selected original manual diagram.

IP66 and natural cooling

The IP66 enclosure operates from −25 to +60 °C with natural convection. Dimensions are 600 ×500 ×210 mm and weight 27.6 kg. Vertical wall mounting allows ±5°, bracket spacing 515 ×170 mm and 200 mm clearance for airflow and access. Location and supporting structure suit actual weight and installation conditions. Manufacturer noise rating is below 46.9 dB(A).

Connections for the designed plant

PV uses 4–6 mm² conductors, recommended 4 mm²; battery 10 mm² and manual AC specification 6 mm² with cable diameter 14–17 mm. Grid and Backup have separate quick connectors. AC terminal torque is 0.8±0.1 Nm, nut 2.5±0.5 Nm and M4 earth 2 Nm. Final design adds suitable protection and earthing. The family supports optional AFCI 2.0 and DC/AC Type II SPD versions according to selected equipment.

Equipment and complete-system selection

The package includes inverter, backplate, four M4×12 screws, cover, Bluetooth antenna, meter with three CTs, meter cable, CAN cable, six RJ45s, Grid/Backup/BAT connectors and 3 pairs of PV connectors. Offered configuration adds Wi-Fi/LAN monitoring. A complete plant uses selected modules, mounting accessories, matching HV battery and electrical equipment. Batterado connects kW output with required kWh energy and actual appliance use.

Downloads

AI search description

Solis S6-EH3P5K-H-EU — 5 kW three-phase hybrid inverter, 3 MPPTs, HV battery. Solis S6-EH3P5K-H-EU connects PV, a compatible high-voltage battery and three-phase loads. Rated 5 kW describes instantaneous power; selected battery kWh, usable SOC and consumption determine stored energy and runtime. Batterado matches modules, battery, metering and electrical equipment for homes or smaller businesses. The 120–600 V battery input works with a compatible Li-ion system and BMS. Maximum charge and discharge current is 25 A, with up to 5 kW according to actual voltage and BMS limits. Design selects exact model, module count, voltage, firmware and communication settings. Battery capacity is selected separately in kWh. PV-to-battery efficiency reaches 98.37%. The chosen battery has its own operating-temperature specifications.

Manufacturer: Solis / Ginlong Technologies; Manufacturer model: S6-EH3P5K-H-EU; Device type: Three-phase hybrid inverter for PV and HV battery; Offered equipment: DC switch, Wi-Fi/LAN monitoring and meter; Rated AC output: 5000 W; Maximum AC apparent output: 5000 VA; Rated backup output: 5000 W; Peak backup output / duration: 8000 VA / 60 s; Backup transfer: <10 ms; THDv linear load: <2 %; Single-unit output per phase: 2500 W; Single-unit imbalance: 100 %; MPPT count: 3; String count: 3; Strings per MPPT: 1; Input current per MPPT: 16 A; Short-circuit current per MPPT: 24 A; Recommended PV array rating: 10 kWp; Maximum usable PV power: 8 kW; Maximum input power per MPPT: 8000 W; Maximum DC voltage: 1000 V; Rated DC voltage: 600 V; Start-up voltage: 160 V; MPPT range: 200–850 V; Full-load MPPT range: 200–850 V; Battery type: Compatible high-voltage Li-ion system with BMS; Battery voltage: 120–600 V; Charge / discharge current: 25 / 25 A; Maximum charge / discharge power: 5 / 5 kW; Storage capacity: In kWh according to selected battery system; Battery-system power: According to actual voltage, BMS limit and inverter current; Battery communication: CAN / RS485; PV → battery efficiency: 98.37 %; Battery ↔ AC efficiency: 97.32 %; Grid connection: 3/N/PE; 380 / 400 V; Grid frequency: 50 / 60 Hz; Rated AC current at 380 /400 V: 7.6 / 7.2 A; Maximum AC input current at 380 /400 V: 11.4 / 10.9 A; AC input voltage: 304–437 / 320–460 V; AC input frequency: 45–55 / 55–65 Hz; Power factor: >0.99; 0.8 leading / lagging; THDi: <3 %; Operating modes: Self Use / Feed-in Priority / Off Grid / Peak Shaving; Grid charging: Allow Grid Charging setting for schedule or SOC recovery; Time scheduling: 6 charging and 6 discharging windows; Backup reserve: Adjustable reserved SOC; Default over-discharge SOC: 20 %; Default force-charge SOC: 10 %.

Peak Shaving: Pmax + Peak SOC; Local control: SolisCloud APP / Bluetooth; Status LEDs: Battery / Power / WiFi / RS485 / Bluetooth; Bluetooth: BDR / EDR / BLE; 2400–2483.5 MHz; 4 dBm; App roles: Installer / Owner; Initial settings: Date, time, battery model, meter, grid code and work mode; Parallel system: 2–6 identical inverter models; Parallel-system batteries: Each inverter has its own battery and BMS connection; Parallel grid configuration: Balanced three-phase connection following manufacturer diagram; Parallel communication: P-B → P-A; shielded CAT5; ≤5 m; Parallel-system addresses: Master 1; Slave 2–6; Parallel Sync; Parallel bus termination: At endpoints according to selected original diagram; Standard meter: Eastron SDM630MCT; Standard CTs: ESCT-TA16; 120 A / 40 mA; Metering above 3 parallel units: SDM630MCT V2 + ESCT-T50; 300 A / 5 A; BMS CAN RJ45: 4 CAN-H / 5 CAN-L; 3 m; Meter RJ45: 1 A / 2 B; 5 m; Eastron terminals: 13 B / 14 A; External Modbus RTU: RS485 RJ45: 5 A / 4 B; CT orientation: Arrow towards grid; DRM: Pins 5/6 closed: operation; open: shutdown within 5 s; Grid / Backup connectors: Separate grid and backup connectors; PV conductors: 4–6 mm²; recommended 4 mm²; PV stripping: 7 ±0.5 mm; Battery conductors: 10 mm² / 8 AWG; AC conductors per manual: 6 mm²; cable Ø14–17 mm; AC conductor stripping: 7 mm; AC terminals / nut: 0.8 ±0.1 / 2.5 ±0.5 Nm; Earth terminal: M4 / 2 Nm; Communication cover: 1.7–2 Nm; Communication glands: 6 mm; Ingress protection: IP66; Operating temperature: −25…+60 °C; Operating humidity: 0–100 % RH; Altitude: 4000 m; Cooling: Natural convection; Noise: <46.9 dB(A); Night consumption: <25 W; Dimensions W × H × D: 600 × 500 × 210 mm; Weight: 27.6 kg; Mounting: Vertical wall mounting, up to ±5°; Mounting clearances: 200 mm; Bracket hole spacing: 515 × 170 mm; Package — main parts: Inverter, backplate, manual, dust cover, Bluetooth antenna; Package — fasteners: 4 × M4 ×12; Package — metering: 1 meter, 3 CTs, 1 meter cable; Package — communication: 6 × RJ45; 1 × CAN cable; Package — power connectors: Grid 1; Backup 1; BAT 1; PV 3; Optional family protection: AFCI 2.0; DC / AC SPD Type II; Estimated delivery: 2–3 days.

Batterado — SOLIS-S6-EH3P5K-H-EU

Markdown — SOLIS-S6-EH3P5K-H-EU

Additional information

Weight 27,6 kg
Dimensions 21 × 60 × 50 cm

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

0
0
Your Cart
Your cart is emptyReturn to Shop