Store energy. Every way.™

Solis S6-GC3P36K03-NV-ND — 36 kW three-phase grid inverter, 3 MPPT, IP66

38 463 Kč incl. VAT

Ask about this product

High-output commercial PV with convenient local Bluetooth control through the SolisCloud app. Solis S6-GC3P36K03-NV-ND supplies 36 kW to a three-phase grid and supports up to 54 kWp of PV. Three independent MPPTs connect six strings at up to 42 A per tracker. The 26.5 kg enclosure combines IP66, C5 corrosion resistance and intelligent fan cooling. Two independent RS485 interfaces connect metering, control and multi-device monitoring. A compatible meter or sensor adds export management and suitable Solis monitoring enables a 24-hour consumption overview. String monitoring and I/V scanning provide further insight into generation. This offer supplies the standard configuration with DC switch and C5 corrosion protection.

Available on back-order

SKU: SOLIS-S6-GC3P36K03-NV-ND
Category:
Tags: , , ,
Značky:

Description

Technical specifications

Manufacturer Solis / Ginlong Technologies
Manufacturer model S6-GC3P36K03-NV-ND
Offered configuration Standard configuration with DC switch and C5
Type and operating system Three-phase grid PV inverter; PV array and utility grid
Recommended maximum PV power 54000 Wp
Maximum DC voltage 1100 V
Rated DC voltage 600 V
Start-up voltage 180 V
MPPT range 180–1000 V
MPPT count 3
Maximum string count 6
Strings per MPPT 2
Maximum current per MPPT 42 A
Maximum short-circuit current per MPPT 52.5 A
Rated AC output 36000 W
Maximum AC output 36000 W
Maximum apparent output 36000 VA
Rated grid voltage 3 / N / PE; 220 / 380 V; 230 / 400 V
Grid frequency 50 / 60 Hz
Rated AC current at 380/400 V 54.7 / 52.0 A
Maximum AC current at 380/400 V 54.7 / 52.0 A
Power factor >0.99; adjustable 0.8 leading to 0.8 lagging
THDi <3 %
Maximum efficiency 98.5 %
European efficiency 98 %
Night consumption <1 W
Maximum input power per MPPT 25000 W
DC polarity protection Integrated function
Short-circuit protection Integrated function
AC overcurrent protection Integrated function
Surge protection Integrated function
Grid monitoring Integrated function
Anti-islanding protection Integrated function
Temperature protection Integrated function
String monitoring Integrated function
I/V scanning Integrated function
Multi-peak MPPT scanning Integrated function
DC switch Integrated function
AFCI 2.0 arc protection Optional family configuration; standard configuration offered
DC connectors MC4
AC connection OT terminal block; L1/L2/L3/N/PE
User interface LED / Bluetooth / SolisCloud APP
Communication Two independent RS485 interfaces; optional Wi-Fi/GPRS
Physical communication ports USB COM for logger and 16-pin COM for control
RS485-1 input / output 16pin COM: IN 5 A /6 B; OUT 7 A /8 B
RS485-2 and meter 16pin COM:1 METER-A/RS485-2A;2 METER-B/RS485-2B
Second RS485 use Meter or third-party controller/monitoring platform according to configuration
European DRM connection 9 DRM 1/5;10 DRM 2/6;11 DRM 3/7;12 DRM 4/8
Logic control 13 RefGen /14 GND
COM supply pins 15 +12 V OUT;16 GND
Reserved COM pins 3 /4
Logic control — response When enabled, opening 13/14 limits output to 0 W within 5 s
COM — conductor / cable diameter 0.75–3 mm² /4–6 mm
COM — conductor stripping 10–12 mm
COM — nut / terminal torque 3.5–4 Nm /0.4–0.6 Nm
Optional data loggers Wi-Fi/GPRS/LAN stick for one inverter; Wi-Fi/GPRS box for multiple devices
Three-phase metering Compatible smart meter with external CTs according to design
Meter communication wiring 21 A /22 B → pins 1 A /2 B of 16-pin COM
Local control application SolisCloud — Bluetooth; Android /iOS
Application access roles Installer /Owner
Displayed data PV voltage/current/power, AC voltage/current, today/yesterday/month/year/total generation
Application technical information SN, model, rated power, DSP/HMI firmware, grid code, DRM and operating data
Diagnostics Alarm, code, grade and corresponding guidance in the app
Power control Maximum AC output, PF Curve and power-change gradients
Grid operating modes No response /Volt-watt /Volt-var /Fixed power factor /Fixed reactive power /Power-PF
Metering settings Meter selection, CT ratio and direction for actual installation
Built-in EPM modes EPM ALL OFF /CT Sensor /Meter in Grid /Meter in Load /Meter 24-Hour Monitoring /CT Load Monitoring
EPM application Built-in EPM for one inverter; external EPM for multiple inverters
Export management Permitted grid-export power and failsafe settings
24-hour consumption Solis monitoring, grid-side metering and 24-Hour Load Monitoring
G100V2 settings Control switch, backflow current and Domestic/Non-domestic alarm reset according to installation
Generation calibration Daily, monthly, yearly and total yield
Multi-peak scan — settings Enable/disable and scan interval
Logic control — DI settings P_Limit DI 1–DI 4
Fan modes Silent /Normal /Performance
AFCI — automatic recovery For AFCI version:1st–4th alarm in 24 h,5 min delay;5th alarm requires manual reset after circuit inspection
Dimensions W × H × D 355 × 625 × 250 mm
Weight 26.5 kg
Ingress protection IP66
Corrosion resistance C5
Topology Transformerless
Cooling Intelligent fan cooling
Typical noise ≤55 dB(A)
Operating temperature −25 to +60 °C
Operating humidity 0–100 % RH
Altitude 4000 m
Storage temperature −40 to +70 °C
Storage humidity 0–95 % RH, non-condensing
Stacking packaged units Maximum 3 high
Mounting position Vertical or backward tilt up to 15°
Mounting structure Firm fire-resistant structure with airflow
Mounting clearances 500 mm above, at sides and above floor per figure 5.2
Handling Two people; two upper holes for suitable lifting equipment
Mounting anchors / drilling M10 × 70 /Ø10 × 60 mm
Bracket dimensions / hole spacing 194 × 116 × 26.5 mm /141 × 75 mm
Bracket holes 4 × 7.5 × 6.5 mm
External earthing Copper≥16 mm², M6 lug,3–4 Nm
DC cable 4–6 mm², recommended 4 mm², PV1-F
DC — stripping 7 ±0.5 mm
AC cable 6–25 mm²; recommended 25 mm²
AC — cable diameter 13–25 mm; recommended 25 mm
AC — stripping Sheath 80 mm; conductors per crimp length S2=S1
AC — terminal torque 3–4 Nm
AC — cable resistance <1.5 Ω
AC — neutral conductor Connection according to local grid requirements
Recommended AC breaker 63 A
Package — inverter / bracket 1 /1
Package — screws / DC / OT 2 /6 /5
Package — AC cover / quick guide 1 /1
16-pin COM connector Included connection component per manual
Optional system components Compatible meter/sensor, logger and external EPM according to design
Safety IEC /EN 62109-1/-2
EMC IEC /EN 61000-6-1/-2/-3/-4
Grid standards G98/G99; VDE-AR-N 4105/VDE V 0124; EN 50549-1; VDE 0126/UTE C 15/VFR:2019; RD 1699/RD 244/UNE 206006/206007-1; CEI 0-21; C10/11; NRS 097-2-1; TOR; EIFS2 018.2; IEC 62116/61727/60068/61683; EN 50530
Estimated delivery 2–3 days

Commercial module generation

S6-GC3P36K03-NV-ND uses a PV array for the three-phase supply of a business, workshop or larger building. Its 36 kW rating describes instantaneous conversion power; kWh energy depends on sun, orientation and array size. The inverter operates with connected modules and utility grid. Generation serves local consumption and export can be managed for the connection conditions.

Three MPPTs and high-current modules

Three independent trackers each serve two strings, six overall. Each MPPT supports 42 A input and 52.5 A short-circuit current with 25000 W maximum input power. Recommended maximum total array power is 54000 Wp. Start-up begins at 180 V, MPPT spans 180–1000 V and maximum voltage is 1100 V. Design compares actual module currents and string voltage at the local minimum temperature; separate trackers provide clear grouping of modules.

Exact output and efficiency

Rated and maximum AC output are 36000 W, with 36000 VA maximum apparent power. Rated and maximum current are 54.7 / 52.0 A at 380/400 V. Connection 3/N/PE uses 220/380 or 230/400 V at 50/60 Hz. Maximum efficiency 98.5% is complemented by 98% European efficiency and THDi below 3%. Adjustable power factor supports grid requirements. Transformerless construction has night consumption below 1 W.

Bluetooth and SolisCloud in use

Local setup uses Bluetooth in the SolisCloud app for Android or iOS. Installer and Owner roles provide corresponding controls. Home shows PV/AC data and daily, monthly, yearly and total generation. Information includes model, serial number, output, DSP/HMI firmware and grid code. Diagnosis displays the alarm, its code, grade and relevant guidance. Status LEDs provide a quick check of power, operation, alarm and Bluetooth.

Two independent RS485 interfaces

The 16-pin COM provides two independent interfaces. RS485-1 uses input 5 A/6 B and output 7 A/8 B for daisy chaining and EPM control. RS485-2 on pins 1 A/2 B serves the meter or, according to configuration, a third-party controller and monitoring platform. A separate USB COM serves an optional logger. For remote monitoring the manual lists Wi-Fi/GPRS/LAN sticks and multi-device boxes. Pinout, cable sizes and connector torques appear in the technical overview.

Metering and export control

A compatible three-phase CT meter or suitable smart sensor provides export-control data. The app selects the actual meter, CT ratio/direction and permitted export. Built-in EPM serves one inverter; external EPM serves multiple devices. Modes include CT Sensor, Meter in Grid, Meter in Load and dedicated 24-hour monitoring modes. A full-day overview uses grid-side metering and enabled 24-Hour Load Monitoring with Solis monitoring.

Adapting to the grid connection

Active output, PF Curve and power-change gradients help match generation to the connection. Grid modes include Volt-watt, Volt-var, fixed power factor, fixed reactive power and Power-PF. Grid protection parameters follow the approved connection. Metering failsafe and any G100V2 settings match the actual regulation scheme. The app also provides time, device addressing, generation calibration and multi-peak MPPT scan interval settings.

Construction and environment

The 355 × 625 × 250 mm enclosure weighs 26.5 kg and offers IP66 with C5 corrosion resistance. Dust-tight protection against powerful water jets supports suitable indoor or outdoor locations. Intelligent fan cooling includes Silent, Normal and Performance modes. The current datasheet specifies typical noise at most 55 dB(A). Operating conditions are −25 to +60°C,0–100% humidity and altitude up to 4000 m. The site provides airflow and shelter from direct sun and rain.

Mounting and electrical connections

A firm fire-resistant structure supports vertical mounting or backward tilt up to 15°. The manual shows 500 mm clearance above, at the sides and above floor. Two people or suitable lifting equipment use the upper handling points. External earthing uses at least 16 mm² copper and an M6 lug. DC conductors are 4–6 mm², AC 6–25 mm² with 25 mm² recommended; actual routing and design determine the size. AC terminal torque is 3–4 Nm and recommended protection 63 A. Exact bracket dimensions, cable details and diagrams appear in the overview and gallery.

Protection and selected equipment

This offer supplies the standard DC-switch and C5 configuration; the range also supports optional AFCI 2.0. Integrated functions cover DC polarity, short circuit, AC overcurrent, surge, grid monitoring, anti-islanding and temperature. The European logic interface uses pins 13 RefGen and 14 GND; when enabled, opening the contact limits output to 0 W within 5 s. Exact settings match the grid profile and control design.

Equipment and complete system design

The package includes inverter, bracket, two screws, six DC connectors, five OT lugs, AC cover and quick installation guide. The 16-pin COM connector is a connection component according to the manual. Optional logger, meter or sensor, external EPM, modules and mounting components are selected for the plant. kW output is assessed separately from kWh energy; any storage uses a separately designed compatible battery system with an appropriate converter. Batterado helps match suitable components. Storage conditions are −40 to +70°C,0–95% non-condensing humidity and up to three packaged units high.

Downloads

AI search description

High-output commercial PV with convenient local Bluetooth control through the SolisCloud app. Solis S6-GC3P36K03-NV-ND supplies 36 kW to a three-phase grid and supports up to 54 kWp of PV. Three independent MPPTs connect six strings at up to 42 A per tracker. The 26.5 kg enclosure combines IP66, C5 corrosion resistance and intelligent fan cooling. Two independent RS485 interfaces connect metering, control and multi-device monitoring. A compatible meter or sensor adds export management and suitable Solis monitoring enables a 24-hour consumption overview. String monitoring and I/V scanning provide further insight into generation. This offer supplies the standard configuration with DC switch and C5 corrosion protection. S6-GC3P36K03-NV-ND uses a PV array for the three-phase supply of a business, workshop or larger building. Its 36 kW rating describes instantaneous conversion power; kWh energy depends on sun, orientation and array size. The inverter operates with connected modules and utility grid. Generation serves local consumption and export can be managed for the connection conditions. The package includes inverter, bracket, two screws, six DC connectors, five OT lugs, AC cover and quick installation guide. The 16-pin COM connector is a connection component according to the manual. Optional logger, meter or sensor, external EPM, modules and mounting components are selected for the plant. kW output is assessed separately from kWh energy; any storage uses a separately designed compatible battery system with an appropriate converter. Batterado helps match suitable components. Storage conditions are −40 to +70°C,0–95% non-condensing humidity and up to three packaged units high.

Manufacturer: Solis / Ginlong Technologies; Manufacturer model: S6-GC3P36K03-NV-ND; Offered configuration: Standard configuration with DC switch and C5; Type and operating system: Three-phase grid PV inverter; PV array and utility grid; Recommended maximum PV power: 54000 Wp; Maximum DC voltage: 1100 V; Rated DC voltage: 600 V; Start-up voltage: 180 V; MPPT range: 180–1000 V; MPPT count: 3; Maximum string count: 6; Strings per MPPT: 2; Maximum current per MPPT: 42 A; Maximum short-circuit current per MPPT: 52.5 A; Rated AC output: 36000 W; Maximum AC output: 36000 W; Maximum apparent output: 36000 VA; Rated grid voltage: 3 / N / PE; 220 / 380 V; 230 / 400 V; Grid frequency: 50 / 60 Hz; Rated AC current at 380/400 V: 54.7 / 52.0 A; Maximum AC current at 380/400 V: 54.7 / 52.0 A; Power factor: >0.99; adjustable 0.8 leading to 0.8 lagging; THDi: <3 %; Maximum efficiency: 98.5 %; European efficiency: 98 %; Night consumption: <1 W; Maximum input power per MPPT: 25000 W; DC polarity protection: Integrated function; Short-circuit protection: Integrated function; AC overcurrent protection: Integrated function; Surge protection: Integrated function; Grid monitoring: Integrated function; Anti-islanding protection: Integrated function; Temperature protection: Integrated function; String monitoring: Integrated function; I/V scanning: Integrated function; Multi-peak MPPT scanning: Integrated function; DC switch: Integrated function; AFCI 2.0 arc protection: Optional family configuration; standard configuration offered; DC connectors: MC4; AC connection: OT terminal block; L1/L2/L3/N/PE; User interface: LED / Bluetooth / SolisCloud APP; Communication: Two independent RS485 interfaces; optional Wi-Fi/GPRS; Physical communication ports: USB COM for logger and 16-pin COM for control; RS485-1 input / output: 16pin COM: IN 5 A /6 B; OUT 7 A /8 B; RS485-2 and meter: 16pin COM:1 METER-A/RS485-2A;2 METER-B/RS485-2B; Second RS485 use: Meter or third-party controller/monitoring platform according to configuration; European DRM connection: 9 DRM 1/5;10 DRM 2/6;11 DRM 3/7;12 DRM 4/8; Logic control: 13 RefGen /14 GND; COM supply pins: 15 +12 V OUT;16 GND; Reserved COM pins: 3 /4; Logic control — response: When enabled, opening 13/14 limits output to 0 W within 5 s; COM — conductor / cable diameter: 0.75–3 mm² /4–6 mm; COM — conductor stripping: 10–12 mm; COM — nut / terminal torque: 3.5–4 Nm /0.4–0.6 Nm.

Optional data loggers: Wi-Fi/GPRS/LAN stick for one inverter; Wi-Fi/GPRS box for multiple devices; Three-phase metering: Compatible smart meter with external CTs according to design; Meter communication wiring: 21 A /22 B → pins 1 A /2 B of 16-pin COM; Local control application: SolisCloud — Bluetooth; Android /iOS; Application access roles: Installer /Owner; Displayed data: PV voltage/current/power, AC voltage/current, today/yesterday/month/year/total generation; Application technical information: SN, model, rated power, DSP/HMI firmware, grid code, DRM and operating data; Diagnostics: Alarm, code, grade and corresponding guidance in the app; Power control: Maximum AC output, PF Curve and power-change gradients; Grid operating modes: No response /Volt-watt /Volt-var /Fixed power factor /Fixed reactive power /Power-PF; Metering settings: Meter selection, CT ratio and direction for actual installation; Built-in EPM modes: EPM ALL OFF /CT Sensor /Meter in Grid /Meter in Load /Meter 24-Hour Monitoring /CT Load Monitoring; EPM application: Built-in EPM for one inverter; external EPM for multiple inverters; Export management: Permitted grid-export power and failsafe settings; 24-hour consumption: Solis monitoring, grid-side metering and 24-Hour Load Monitoring; G100V2 settings: Control switch, backflow current and Domestic/Non-domestic alarm reset according to installation; Generation calibration: Daily, monthly, yearly and total yield; Multi-peak scan — settings: Enable/disable and scan interval; Logic control — DI settings: P_Limit DI 1–DI 4; Fan modes: Silent /Normal /Performance; AFCI — automatic recovery: For AFCI version:1st–4th alarm in 24 h,5 min delay;5th alarm requires manual reset after circuit inspection; Dimensions W × H × D: 355 × 625 × 250 mm; Weight: 26.5 kg; Ingress protection: IP66; Corrosion resistance: C5; Topology: Transformerless; Cooling: Intelligent fan cooling; Typical noise: ≤55 dB(A); Operating temperature: −25 to +60 °C; Operating humidity: 0–100 % RH; Altitude: 4000 m; Storage temperature: −40 to +70 °C; Storage humidity: 0–95 % RH, non-condensing; Stacking packaged units: Maximum 3 high; Mounting position: Vertical or backward tilt up to 15°; Mounting structure: Firm fire-resistant structure with airflow; Mounting clearances: 500 mm above, at sides and above floor per figure 5.2; Handling: Two people; two upper holes for suitable lifting equipment; Mounting anchors / drilling: M10 × 70 /Ø10 × 60 mm; Bracket dimensions / hole spacing: 194 × 116 × 26.5 mm /141 × 75 mm; Bracket holes: 4 × 7.5 × 6.5 mm; External earthing: Copper≥16 mm², M6 lug,3–4 Nm; DC cable: 4–6 mm², recommended 4 mm², PV1-F; DC — stripping: 7 ±0.5 mm; AC cable: 6–25 mm²; recommended 25 mm²; AC — cable diameter: 13–25 mm; recommended 25 mm; AC — stripping: Sheath 80 mm; conductors per crimp length S2=S1; AC — terminal torque: 3–4 Nm; AC — cable resistance: <1.5 Ω; AC — neutral conductor: Connection according to local grid requirements; Recommended AC breaker: 63 A; Package — inverter / bracket: 1 /1; Package — screws / DC / OT: 2 /6 /5; Package — AC cover / quick guide: 1 /1; 16-pin COM connector: Included connection component per manual; Optional system components: Compatible meter/sensor, logger and external EPM according to design; Safety: IEC /EN 62109-1/-2; EMC: IEC /EN 61000-6-1/-2/-3/-4; Grid standards: G98/G99; VDE-AR-N 4105/VDE V 0124; EN 50549-1; VDE 0126/UTE C 15/VFR:2019; RD 1699/RD 244/UNE 206006/206007-1; CEI 0-21; C10/11; NRS 097-2-1; TOR; EIFS2 018.2; IEC 62116/61727/60068/61683; EN 50530; Estimated delivery: 2–3 days.

Batterado — SOLIS-S6-GC3P36K03-NV-ND

Markdown — SOLIS-S6-GC3P36K03-NV-ND

Additional information

Weight 26,5 kg
Dimensions 25 × 35,5 × 62,5 cm

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

0
0
Your Cart
Your cart is emptyReturn to Shop