Store energy. Every way.™

Solis S5-GR3P20K — 20 kW three-phase grid inverter, 2 MPPT, IP66

20 519 Kč incl. VAT

Ask about this product

Three-phase solar generation for homes and smaller businesses. Solis S5-GR3P20K supplies 20 kW rated output and accepts up to 30 kWp of PV through two independent MPPTs. It connects up to 4 strings with 32 A per tracker and a 160–1000 V MPPT range. IP66, intelligent fan cooling, efficiency up to 98.7 % and a weight of 20.8 kg complement the compact enclosure. An optional DTSD1352-C meter enables export management and, with suitable monitoring, a 24-hour consumption overview. The offer supplies the specified inverter with DC switch and standard connection components.

Available on back-order

SKU: SOLIS-S5-GR3P20K
Category:
Tags: , , ,
Značky:

Description

Technical specifications

Manufacturer Solis / Ginlong Technologies
Model S5-GR3P20K
Type and role Three-phase grid-connected PV inverter
Offered configuration Standard model with 2 MPPTs and DC switch
Operating configuration PV array and three-phase utility grid
Recommended maximum PV power 30000 Wp
Maximum DC voltage 1100 V
Rated DC voltage 600 V
Start-up voltage 180 V
MPPT range 160–1000 V
Maximum input current MPPT 1 / 2 32 / 32 A
Maximum short-circuit current MPPT 1 / 2 40 / 40 A
Independent MPPT count 2
Maximum PV string count 4
Strings on MPPT 1 / 2 2 / 2
Rated AC power 20000 W
Maximum AC power 22000 W
Maximum apparent AC power 22000 VA
Grid conductors 3 / N / PE
Rated grid voltage 220 / 380 V; 230 / 400 V
Rated frequency 50 / 60 Hz
Operating frequency 45–55 / 55–65 Hz
Rated current at 380/400 V 30.4 / 28.9 A
Maximum AC current 31.8 A
Power factor >0.99; adjustable 0.8 leading to 0.8 lagging
THDi <2 %
Maximum efficiency 98.7 %
European efficiency 98.1 %
Topology Transformerless
Night consumption <1 W
DC polarity protection Integrated function
Short-circuit protection Integrated function
AC overcurrent protection Integrated function
Surge protection Integrated function
Grid monitoring Integrated function
Anti-islanding protection Integrated function
Temperature protection Integrated function
Multi-peak MPPT scanning Integrated function
DC switch Integrated function
AFCI 2.0 arc protection Optional configuration
DC connectors MC4
AC connector Quick connector L1 / L2 / L3 / N / PE
Communication RS485; DO / DI
Communication connectors RS485 COM, CT/Meter, DRM; RJ45 and terminal connections according to manual
Digital meter DTSD1352-C / DTSD1352
Direct metering DTSD1352-C, up to 80 A
Transformer metering DTSD1352-C; 150 A / 5 A CT
Meter — communication terminals 21 A / 22 B → two-pin inverter connector
Remote monitoring Optional Wi-Fi / GPRS data logger and Solis monitoring
Inverter monitoring address 01–99; default 01
LCD display 2 lines × 20 characters
Controls ESC / UP / DOWN / ENTER
LED indicators POWER / OPERATION / ALARM
Displayed operating data PV and phase voltages/currents, power, frequency, energy, status, serial number and version
Generation history Daily, monthly and yearly energy
Alarm / warning history Latest 100 records in each history
Export control Internal EPM; Meter in Load / Meter in Grid / Consumption Monitor
Permitted-export setting range 0–29,900 W; output according to model rating and connection
Export-limit modes 01 average / 02 according to lowest-loaded phase
24-hour consumption monitoring Grid-side meter, 24H Switch and Solis monitoring
Meter failsafe Configurable alarm and generation stop on metering loss
External EPM 5G-EPM / Others-EPM according to actual device
Active and reactive power control Power settings and PF Curve
DRM — logic interface RJ45: pin 5 Switch_input1 / pin 6 Switch_input2
DRM — response after opening Limit to 0 W within 5 s when enabled according to grid profile
Service updates HMI / DSP
User-Def — grid-profile use Service configuration with grid-operator permission; L–N ranges per manual
User-Def — overvoltage OV-G-V1 / V2 220–374 V; 0.01–300 s
User-Def — undervoltage UN-G-V1 / V2 110–277 V; 0.01–300 s
User-Def — overfrequency OV-G-F1 / F2 50.1–65 Hz; 0.01–300 s
User-Def — underfrequency UN-G-F1 / F2 45–59.9 Hz; 0.01–300 s
User-Def — Startup-T / Restore-T 10–600 s / 10–600 s
Dimensions W × H × D 310 × 563 × 219 mm
Weight 20.8 kg
Ingress protection IP66
Operating temperature −25 to +60 °C
Relative operating humidity 0–100 % RH
Cooling Intelligent fan cooling
Typical noise <60 dB(A)
Maximum altitude 4000 m
Storage temperature −40 to +70 °C
Storage humidity 0–95 % RH, non-condensing
Stacking packaged units Maximum 3 units high
Mounting position Vertical ±5° or backward tilt up to 15°
Airflow clearance 500 mm above, at the sides and above floor; 1000 mm in front as illustrated
Mounting structure Firm fire-resistant wall with airflow
Mounting — anchors in manual ST6.3 × 60; HJ0108 10 × 50 mm; Ø10 × 60 mm drilling
Opening for own security lock Ø5 mm
External earthing Copper conductor ≥6 mm², M6 lug, 3 Nm
DC cable 4–6 mm²; recommended 4 mm², PV1-F
DC — stripping length 7 mm
DC — connector torque 2.5–3 Nm
AC cable 6–16 mm²
AC — cable outer diameter 13–25 mm
AC — sheath / PE / conductor stripping 70 / 70 / 9 mm; other conductors 60 mm
AC — terminal torque 1.8–2.0 Nm
AC — swivel-nut torque 3–4 Nm
AC — maximum cable resistance per manual <1.5 Ω
Recommended AC breaker 40 A
AC — cross-section beyond 20 m 10–16 mm²
AC — sealing rings Thick 12–18 mm / thin 16–21 mm according to cable
Package — inverter / bracket 1 / 1
Package — fastening screws 2
Package — DC connectors 4
Package — AC / RJ45 / manual 1 / 1 / 1
Optional system components Digital meter, Wi-Fi/GPRS logger, external EPM and security lock according to design
Safety IEC / EN 62109-1 / -2
EMC IEC / EN 61000-6-1 / -2 / -3 / -4
Grid standards G99; VDE-AR-N 4105 / VDE V 0124; EN 50549-1; VDE 0126 / UTE C 15 / VFR:2019; RD 1699 / RD 244 / UNE 206006 / UNE 206007-1; CEI 0-21; C10/11; NRS 097-2-1; EIFS 2018.2; IEC 62116 / 61727 / 60068 / 61683; EN 50530
Estimated delivery 2–3 days

Own electricity for a three-phase supply

S5-GR3P20K uses module energy for normal grid-connected operation in a home, workshop or smaller business. Its 20000 W rating describes conversion power; daily kWh depend on irradiation, orientation and array size. Operation requires a PV array and connected utility grid. Local loads use generation directly at the supply point.

Two MPPTs for array design

Two independent trackers follow separate string groups. This model accepts up to 4 strings, two per MPPT. Operating current is limited to 32 A and short-circuit current to 40 A per tracker. Recommended maximum array power is 30000 Wp, start-up voltage 180 V, MPPT range 160–1000 V and maximum DC voltage 1100 V. Design compares actual module currents and open-circuit voltage at the local minimum temperature.

Output, phases and efficiency

The datasheet specifies 20000 W rated output, 22000 W maximum AC output and 22000 VA apparent power. Connection is 3/N/PE at 220/380 or 230/400 V, 50/60 Hz. Maximum efficiency is 98.7 %, European efficiency 98.1 % and THDi below 2 %. Adjustable power factor supports the actual grid requirements at the supply point.

Three-phase metering and export

The optional DTSD1352-C measures energy flow directly up to 80 A or through matching 150 A/5 A transformers. The manual also abbreviates the model to DTSD1352. A two-pin communication connector links the meter; its communication terminals are 21 A and 22 B. Export management supports grid-side or load-side metering. Select the actual meter and version as installation components.

Power control for the connection

Internal EPM configures permitted export and metering mode. Mode 01 uses average three-phase consumption; mode 02 bases limiting on the lowest-loaded phase. Configurable failsafe can report lost metering and stop generation. External EPM uses 5G-EPM or Others-EPM according to the actual device. Commissioning verifies flow direction and response.

Monitoring and generation overview

The LCD shows voltage, current, power, frequency, energy and operating state. Separate views track daily, monthly and yearly generation; diagnosis retains the latest 100 alarms and 100 warnings. An optional Wi-Fi or GPRS logger connects the system to monitoring. A 24-hour consumption overview uses a grid-side meter, enabled 24H Switch and configured Solis monitoring. Inverter addresses for shared monitoring range from 01 to 99.

Construction and operating environment

The 310 × 563 × 219 mm enclosure weighs 20.8 kg. The model uses intelligent fan cooling; typical noise is below 60 dB(A). IP66 is complemented by a −25 to +60 °C operating range, 0–100 % humidity and altitude up to 4000 m. A suitable indoor or outdoor location provides airflow and shelter from direct sun and rain.

Mounting and model-specific connections

Mount on a firm fire-resistant structure with appropriate clearance. The manual allows vertical mounting within ±5° or backward tilt up to 15°. The AC connector distinguishes L1, L2, L3, N and PE; the external earthing point uses an M6 lug and copper conductor of at least 6 mm². DC uses MC4 and 4–6 mm² conductors. Exact AC cross-section, torques and recommended breaker for this variant are listed in the technical overview.

Protection and logic control

Integrated functions cover DC polarity, short circuit, AC overcurrent, surge, grid monitoring, anti-islanding and temperature protection. The current datasheet lists AFCI 2.0 as optional. DRM uses RJ45 pins 5 and 6; when enabled, opening the contact allows output reduction to 0 W within five seconds according to the grid profile. Active power, reactive power and PF Curve settings match the actual connection.

Supplied inverter and system components

The standard package includes the inverter, backplate, two fastening screws, 4 DC connectors, one AC connector, one RJ45 connector and manual. This offer includes the DC switch. Select PV modules, meter, logger, wiring, protection and mounting accessories for the whole plant design. Any energy storage is provided by a separately designed compatible battery system with an appropriate converter.

Design around generation and consumption

Selection combines PV output, string voltage and current, available three-phase grid connection and the local consumption profile. Required energy in kWh is assessed separately from instantaneous kW. The Batterado product enquiry helps match system components. For storage the manual specifies −40 to +70 °C and 0–95 % non-condensing humidity; packaged units may be stacked up to three high.

Downloads

AI search description

Three-phase solar generation for homes and smaller businesses. Solis S5-GR3P20K supplies 20 kW rated output and accepts up to 30 kWp of PV through two independent MPPTs. It connects up to 4 strings with 32 A per tracker and a 160–1000 V MPPT range. IP66, intelligent fan cooling, efficiency up to 98.7 % and a weight of 20.8 kg complement the compact enclosure. An optional DTSD1352-C meter enables export management and, with suitable monitoring, a 24-hour consumption overview. The offer supplies the specified inverter with DC switch and standard connection components. S5-GR3P20K uses module energy for normal grid-connected operation in a home, workshop or smaller business. Its 20000 W rating describes conversion power; daily kWh depend on irradiation, orientation and array size. Operation requires a PV array and connected utility grid. Local loads use generation directly at the supply point. The standard package includes the inverter, backplate, two fastening screws, 4 DC connectors, one AC connector, one RJ45 connector and manual. This offer includes the DC switch. Select PV modules, meter, logger, wiring, protection and mounting accessories for the whole plant design. Any energy storage is provided by a separately designed compatible battery system with an appropriate converter.

Manufacturer: Solis / Ginlong Technologies; Model: S5-GR3P20K; Type and role: Three-phase grid-connected PV inverter; Offered configuration: Standard model with 2 MPPTs and DC switch; Operating configuration: PV array and three-phase utility grid; Recommended maximum PV power: 30000 Wp; Maximum DC voltage: 1100 V; Rated DC voltage: 600 V; Start-up voltage: 180 V; MPPT range: 160–1000 V; Maximum input current MPPT 1 / 2: 32 / 32 A; Maximum short-circuit current MPPT 1 / 2: 40 / 40 A; Independent MPPT count: 2; Maximum PV string count: 4; Strings on MPPT 1 / 2: 2 / 2; Rated AC power: 20000 W; Maximum AC power: 22000 W; Maximum apparent AC power: 22000 VA; Grid conductors: 3 / N / PE; Rated grid voltage: 220 / 380 V; 230 / 400 V; Rated frequency: 50 / 60 Hz; Operating frequency: 45–55 / 55–65 Hz; Rated current at 380/400 V: 30.4 / 28.9 A; Maximum AC current: 31.8 A; Power factor: >0.99; adjustable 0.8 leading to 0.8 lagging; THDi: <2 %; Maximum efficiency: 98.7 %; European efficiency: 98.1 %; Topology: Transformerless; Night consumption: <1 W; DC polarity protection: Integrated function; Short-circuit protection: Integrated function; AC overcurrent protection: Integrated function; Surge protection: Integrated function; Grid monitoring: Integrated function; Anti-islanding protection: Integrated function; Temperature protection: Integrated function; Multi-peak MPPT scanning: Integrated function; DC switch: Integrated function; AFCI 2.0 arc protection: Optional configuration; DC connectors: MC4; AC connector: Quick connector L1 / L2 / L3 / N / PE; Communication: RS485; DO / DI; Communication connectors: RS485 COM, CT/Meter, DRM; RJ45 and terminal connections according to manual; Digital meter: DTSD1352-C / DTSD1352; Direct metering: DTSD1352-C, up to 80 A; Transformer metering: DTSD1352-C; 150 A / 5 A CT; Meter — communication terminals: 21 A / 22 B → two-pin inverter connector; Remote monitoring: Optional Wi-Fi / GPRS data logger and Solis monitoring; Inverter monitoring address: 01–99; default 01.

LCD display: 2 lines × 20 characters; Controls: ESC / UP / DOWN / ENTER; LED indicators: POWER / OPERATION / ALARM; Displayed operating data: PV and phase voltages/currents, power, frequency, energy, status, serial number and version; Generation history: Daily, monthly and yearly energy; Alarm / warning history: Latest 100 records in each history; Export control: Internal EPM; Meter in Load / Meter in Grid / Consumption Monitor; Permitted-export setting range: 0–29,900 W; output according to model rating and connection; Export-limit modes: 01 average / 02 according to lowest-loaded phase; 24-hour consumption monitoring: Grid-side meter, 24H Switch and Solis monitoring; Meter failsafe: Configurable alarm and generation stop on metering loss; External EPM: 5G-EPM / Others-EPM according to actual device; Active and reactive power control: Power settings and PF Curve; DRM — logic interface: RJ45: pin 5 Switch_input1 / pin 6 Switch_input2; DRM — response after opening: Limit to 0 W within 5 s when enabled according to grid profile; Service updates: HMI / DSP; User-Def — grid-profile use: Service configuration with grid-operator permission; L–N ranges per manual; User-Def — overvoltage OV-G-V1 / V2: 220–374 V; 0.01–300 s; User-Def — undervoltage UN-G-V1 / V2: 110–277 V; 0.01–300 s; User-Def — overfrequency OV-G-F1 / F2: 50.1–65 Hz; 0.01–300 s; User-Def — underfrequency UN-G-F1 / F2: 45–59.9 Hz; 0.01–300 s; User-Def — Startup-T / Restore-T: 10–600 s / 10–600 s; Dimensions W × H × D: 310 × 563 × 219 mm; Weight: 20.8 kg; Ingress protection: IP66; Operating temperature: −25 to +60 °C; Relative operating humidity: 0–100 % RH; Cooling: Intelligent fan cooling; Typical noise: <60 dB(A); Maximum altitude: 4000 m; Storage temperature: −40 to +70 °C; Storage humidity: 0–95 % RH, non-condensing; Stacking packaged units: Maximum 3 units high; Mounting position: Vertical ±5° or backward tilt up to 15°; Airflow clearance: 500 mm above, at the sides and above floor; 1000 mm in front as illustrated; Mounting structure: Firm fire-resistant wall with airflow; Mounting — anchors in manual: ST6.3 × 60; HJ0108 10 × 50 mm; Ø10 × 60 mm drilling; Opening for own security lock: Ø5 mm; External earthing: Copper conductor ≥6 mm², M6 lug, 3 Nm; DC cable: 4–6 mm²; recommended 4 mm², PV1-F; DC — stripping length: 7 mm; DC — connector torque: 2.5–3 Nm; AC cable: 6–16 mm²; AC — cable outer diameter: 13–25 mm; AC — sheath / PE / conductor stripping: 70 / 70 / 9 mm; other conductors 60 mm; AC — terminal torque: 1.8–2.0 Nm; AC — swivel-nut torque: 3–4 Nm; AC — maximum cable resistance per manual: <1.5 Ω; Recommended AC breaker: 40 A; AC — cross-section beyond 20 m: 10–16 mm²; AC — sealing rings: Thick 12–18 mm / thin 16–21 mm according to cable; Package — inverter / bracket: 1 / 1; Package — fastening screws: 2; Package — DC connectors: 4; Package — AC / RJ45 / manual: 1 / 1 / 1; Optional system components: Digital meter, Wi-Fi/GPRS logger, external EPM and security lock according to design; Safety: IEC / EN 62109-1 / -2; EMC: IEC / EN 61000-6-1 / -2 / -3 / -4; Grid standards: G99; VDE-AR-N 4105 / VDE V 0124; EN 50549-1; VDE 0126 / UTE C 15 / VFR:2019; RD 1699 / RD 244 / UNE 206006 / UNE 206007-1; CEI 0-21; C10/11; NRS 097-2-1; EIFS 2018.2; IEC 62116 / 61727 / 60068 / 61683; EN 50530; Estimated delivery: 2–3 days.

Batterado — SOLIS-S5-GR3P20K

Markdown — SOLIS-S5-GR3P20K

Additional information

Weight 20,8 kg
Dimensions 21,9 × 31 × 56,3 cm

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

0
0
Your Cart
Your cart is emptyReturn to Shop