Store energy. Every way.™

Solis S6-GR1P3K — 3 kW single-phase grid inverter, 2 MPPT, Meter Version

16 108 Kč incl. VAT

Ask about this product

Two independent MPPTs for local solar generation. Solis S6-GR1P3K supplies 3 kW of grid-connected output and accepts up to 4.5 kWp of PV. Each MPPT handles one string at up to 14 A. The Meter Version supports a compatible digital meter for export management and 24-hour load monitoring. IP66, natural cooling, 11.2 kg weight and integrated AFCI requiring activation complement a fixed single-phase installation.

Available on back-order

SKU: SOLIS-S6-GR1P3K
Category:
Tags: , ,
Značky:

Description

Technical specifications

Model S6-GR1P3K
Offered version Digital-meter version (Meter Version)
Type and role Single-phase grid-connected PV inverter
Operating configuration PV array and 220/230 V utility grid
Recommended maximum PV power 4500 Wp
Maximum DC voltage 600 V
Rated DC voltage 330 V
Start-up voltage 120 V
MPPT range 90–520 V
Maximum input current 14 A / 14 A
Maximum short-circuit current 22 A / 22 A
MPPT count 2
PV string count 2 (1 / MPPT)
Rated AC power 3000 W
Maximum AC power 3300 W
Maximum apparent power 3300 VA
Grid conductors 1 / N / PE
Rated grid voltage 220 / 230 V
Rated frequency 50 / 60 Hz
Operating frequency 45–55 / 55–65 Hz
Rated current at 220/230 V 13.6 / 13 A
Maximum AC current 15.7 A
Power factor >0.99; adjustable 0.8 leading to 0.8 lagging
THDi <3 %
Maximum efficiency 97.3 %
European efficiency 96.6 %
Topology Transformerless
Night consumption <1 W
Dimensions W × H × D 310 × 543 × 160 mm
Weight 11.2 kg
Operating temperature −25 to +60 °C
Relative operating humidity 0–100 % RH
Ingress protection IP66
Cooling Natural convection
Typical noise <20 dB(A)
Maximum altitude 4000 m
DC polarity protection Integrated function
Short-circuit protection Integrated function
AC overcurrent protection Integrated function
Surge protection Integrated function
Grid monitoring Integrated function
Anti-islanding protection Integrated function
Temperature protection Integrated function
Multi-peak MPPT scanning Integrated function
DC switch Integrated function
AFCI arc protection Integrated, activation required
DC connection MC4
AC connection Quick connector
Display LCD, 2 × 20 characters
Controls ESC / UP / DOWN / ENTER
LED indicators POWER / OPERATION / ALARM
Communication RS485
Remote monitoring Optional Wi-Fi / GPRS data logger
Compatible digital meters DDSD1352-C / ACR10RD16TE
DDSD1352-C — measurement Direct connection, max. 60 A
ACR10RD16TE — transformer 120 A / 40 mA
Export limitation Meter and Internal EPM configuration
24-hour load monitoring Grid-side meter, 24H Switch and monitoring
Mounting position Vertical, deviation up to 5°
Airflow clearance 300 mm around, 500 mm above floor
DC cable 4–6 mm²; recommended 4 mm²
AC cable 2.5–6 mm²; recommended 6 mm²
Recommended AC breaker 20 A
AC terminal torque 0.8 Nm
PE M4 torque 2 Nm
Standard mounting components Backplate, fastening screws, DC and AC connectors, RJ45 connector and manual according to range package
Safety IEC / EN 62109-1 / -2
EMC IEC / EN 61000-6-2 / -3
Grid standards — selection EN 50549-1; VDE-AR-N 4105; G98 / G99; CEI 0-21; IEC 62116 / 61727

Local generation for a single-phase installation

S6-GR1P3K converts DC energy from modules into grid-connected electricity. Operation requires a suitable PV array and connected utility grid. Its 3000 W rating determines AC conversion power; generated kWh depend on irradiation, orientation and production duration.

Two MPPTs for separate PV arrays

Two independent MPPTs track two separate strings, each up to 14 A with a 22 A short-circuit limit. Recommended maximum PV power is 4500 Wp. This exact model has a 600 V maximum DC voltage, 120 V start-up voltage and 90–520 V MPPT range. String design considers module voltage at the local minimum temperature and actual module currents.

Grid output and efficiency

Rated AC power is 3000 W, with maximum output of 3300 W and 3300 VA. Single-phase connection is 1/N/PE, 220/230 V and 50/60 Hz. The current datasheet specifies 97.3 % maximum and 96.6 % European efficiency for this model. Configure grid profile and reactive power for the actual connection.

Meter Version and matched metering

This version connects a digital meter via RS485. The manual lists DDSD1352-C for direct measurement up to 60 A and ACR10RD16TE with a 120 A/40 mA transformer. Select the meter separately for the installation; commissioning verifies measurement direction and communication settings.

Export control for the supply point

Internal EPM uses a meter on the grid or load side with correctly configured flow direction. Set permitted export and the response to lost communication. Commissioning verifies measurement polarity and actual response to changing consumption.

Visibility beyond solar production hours

For 24-hour consumption monitoring the manual uses a grid-side meter, 24H Switch and suitable monitoring configuration. A Wi-Fi or GPRS data logger is optional equipment. The local LCD and operating LEDs are part of the inverter.

Natural cooling and IP66 protection

The inverter measures 310 × 543 × 160 mm and weighs 11.2 kg. Natural convection removes heat and typical noise is below 20 dB(A). Operating range is −25 to +60 °C, relative humidity 0–100 % and maximum altitude 4000 m. A suitable location provides airflow and shelter from direct sun and rain.

Mounting with cooling clearance

The manual specifies a suitable firm wall, vertical mounting within 5°, 300 mm clearance around the inverter and 500 mm above the floor. Choose airflow and shelter from direct sun and rain. Mounting components include a backplate and fasteners according to the range package.

Integrated protection and AFCI

The inverter includes polarity, short-circuit, AC overcurrent, surge, temperature and anti-islanding protection. Integrated AFCI requires activation according to the datasheet. The DC side uses MC4 and a DC switch; AC uses a quick connector and protective earth. Protection devices and wiring follow the professional installation design.

Individual photovoltaic component

This offer supplies the specified inverter with its standard components. Select modules, meter, logger, wiring and mounting accessories to match the system design. Any energy storage is provided by a separately designed compatible battery system with an appropriate converter.

Selecting output and related products

Selection compares PV power and voltage, module current, available grid connection and the local consumption profile. Daily generated energy is measured in kWh and depends on location and irradiation. Batterado helps match the actual modules, inverter and metering in a suitable configuration.

Downloads

AI search description

Two independent MPPTs for local solar generation. Solis S6-GR1P3K supplies 3 kW of grid-connected output and accepts up to 4.5 kWp of PV. Each MPPT handles one string at up to 14 A. The Meter Version supports a compatible digital meter for export management and 24-hour load monitoring. IP66, natural cooling, 11.2 kg weight and integrated AFCI requiring activation complement a fixed single-phase installation. S6-GR1P3K converts DC energy from modules into grid-connected electricity. Operation requires a suitable PV array and connected utility grid. Its 3000 W rating determines AC conversion power; generated kWh depend on irradiation, orientation and production duration. This offer supplies the specified inverter with its standard components. Select modules, meter, logger, wiring and mounting accessories to match the system design. Any energy storage is provided by a separately designed compatible battery system with an appropriate converter.

Model: S6-GR1P3K; Offered version: Digital-meter version (Meter Version); Type and role: Single-phase grid-connected PV inverter; Operating configuration: PV array and 220/230 V utility grid; Recommended maximum PV power: 4500 Wp; Maximum DC voltage: 600 V; Rated DC voltage: 330 V; Start-up voltage: 120 V; MPPT range: 90–520 V; Maximum input current: 14 A / 14 A; Maximum short-circuit current: 22 A / 22 A; MPPT count: 2; PV string count: 2 (1 / MPPT); Rated AC power: 3000 W; Maximum AC power: 3300 W; Maximum apparent power: 3300 VA; Grid conductors: 1 / N / PE; Rated grid voltage: 220 / 230 V; Rated frequency: 50 / 60 Hz; Operating frequency: 45–55 / 55–65 Hz; Rated current at 220/230 V: 13.6 / 13 A; Maximum AC current: 15.7 A; Power factor: >0.99; adjustable 0.8 leading to 0.8 lagging; THDi: <3 %; Maximum efficiency: 97.3 %; European efficiency: 96.6 %; Topology: Transformerless; Night consumption: <1 W; Dimensions W × H × D: 310 × 543 × 160 mm; Weight: 11.2 kg; Operating temperature: −25 to +60 °C; Relative operating humidity: 0–100 % RH; Ingress protection: IP66; Cooling: Natural convection; Typical noise: <20 dB(A).

Maximum altitude: 4000 m; DC polarity protection: Integrated function; Short-circuit protection: Integrated function; AC overcurrent protection: Integrated function; Surge protection: Integrated function; Grid monitoring: Integrated function; Anti-islanding protection: Integrated function; Temperature protection: Integrated function; Multi-peak MPPT scanning: Integrated function; DC switch: Integrated function; AFCI arc protection: Integrated, activation required; DC connection: MC4; AC connection: Quick connector; Display: LCD, 2 × 20 characters; Controls: ESC / UP / DOWN / ENTER; LED indicators: POWER / OPERATION / ALARM; Communication: RS485; Remote monitoring: Optional Wi-Fi / GPRS data logger; Compatible digital meters: DDSD1352-C / ACR10RD16TE; DDSD1352-C — measurement: Direct connection, max. 60 A; ACR10RD16TE — transformer: 120 A / 40 mA; Export limitation: Meter and Internal EPM configuration; 24-hour load monitoring: Grid-side meter, 24H Switch and monitoring; Mounting position: Vertical, deviation up to 5°; Airflow clearance: 300 mm around, 500 mm above floor; DC cable: 4–6 mm²; recommended 4 mm²; AC cable: 2.5–6 mm²; recommended 6 mm²; Recommended AC breaker: 20 A; AC terminal torque: 0.8 Nm; PE M4 torque: 2 Nm; Standard mounting components: Backplate, fastening screws, DC and AC connectors, RJ45 connector and manual according to range package; Safety: IEC / EN 62109-1 / -2; EMC: IEC / EN 61000-6-2 / -3; Grid standards — selection: EN 50549-1; VDE-AR-N 4105; G98 / G99; CEI 0-21; IEC 62116 / 61727.

Batterado — SOLIS-S6-GR1P3K

Markdown — SOLIS-S6-GR1P3K

Additional information

Weight 11,2 kg
Dimensions 16 × 31 × 54,3 cm

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

0
0
Your Cart
Your cart is emptyReturn to Shop