EVE LF100LA 3.2 V 102 Ah LiFePO4 cell

2 022 Kč incl. VAT

Seller: Tomorrow Systems® s.r.o.

102 Ah in a compact cell for a purpose-built LiFePO4 battery: EVE LF100LA provides 3.2 V and a calculated 326.4 Wh of nominal energy. Sixteen cells form a nominal 51.2 V, 5.2224 kWh block; four provide a 12.8 V foundation. EVE specifies 5,000 cycles at 25 °C and 0.5 C with at least 80% capacity retention. The 160 × 50.1 × 118.5 mm prismatic aluminium body supports a compact enclosure layout. Charging at 0 to 65 °C, discharging at −20 to 65 °C and a maximum 102 A charging current at 25 ± 2 °C give the designer concrete operating figures. A practical choice for a solar battery, backup power or servicing a matching pack. Select the external BMS and its communication profiles to suit the planned cell configuration and inverter.

In stock

Enquiry

Description

Technical specifications

Manufacturer / modelEVE / LF100LA
Construction / chemistryPrismatic aluminium cell / LiFePO4
Nominal voltage3.2 V
Capacity102 Ah
Calculated nominal energy326.4 Wh (3.2 V × 102 Ah)
Capacity measurement0.2 C / 25 ± 2 °C / 2.5–3.65 V
Standard current, specification B0.2 C / 20.4 A (25 ± 2 °C)
Maximum charging current1 C / 102 A (25 ± 2 °C)
Charge cut-off voltage3.65 V
Discharge cut-off above 0 °C2.5 V (0 °C < T ≤ 65 °C)
Discharge cut-off up to 0 °C2.0 V (−20 °C < T ≤ 0 °C)
AC internal resistance≤0.5 mΩ / 1 kHz / 25% SOC
DC internal resistance≤1.5 mΩ / 25 °C / 50% SOC / 0.2 C 30 s + 1 C 5 s
Cycle life at 25 °C5,000 / 0.5 C + 0.5 C / ≥80% capacity
Cycle life at 35 °C3,500 / 0.5 C + 0.5 C / ≥80% capacity
Cycle life at 45 °C2,000 / 0.5 C + 0.5 C / ≥80% capacity
Cell energy efficiency≥93% / 25 °C / 0.5 C
Charging temperature0 to 65 °C
Discharging temperature−20 to 65 °C
Storage over one month0 to 35 °C / 20–40% SOC
Storage up to one month−20 to 45 °C / 20–40% SOC
Width160.0 ± 0.8 mm
Thickness50.1 ± 0.5 mm / 200 kgf / delivery SOC
Height to terminals118.5 ± 0.5 mm
Shoulder height115.7 ± 0.5 mm
Cell weight1,985 ± 100 g
Pack BMSExternal LiFePO4 BMS matched to series count
Pack communication ports and protocolsDetermined by the selected external BMS
4S — calculated voltage / energy12.8 V / 1.3056 kWh
8S — calculated voltage / energy25.6 V / 2.6112 kWh
16S — calculated voltage / energy51.2 V / 5.2224 kWh
Model specificationRD-LF100LA-S01-LF / B
Specific energy in EVE catalogue164 Wh/kg
Capacity retention at −20 °C≥55 %
Capacity retention at 0 °C≥80 %
Capacity retention at 10 °C≥85 %
Capacity retention at 55 °C≥99 %
Rate test at 25 °C / 0.5 C≥100 %
Rate test at 25 °C / 1 C=100 %
Rate test at 25 °C / 2 C≥98 %
Rate test at 25 °C / 2.5 C≥95 %
Float performance / 25 °C / 15 years≥70 %
Capacity recovery / 28 days / 25 °C / 100% SOC≥96 %
Capacity recovery / 28 days / 45 °C / 100% SOC≥90 %
Terminal materialAl 1060
Laser weld penetration depth2,0 mm
Maximum vertical terminal load500 N
Maximum terminal torque — structural figure4 N·m
Terminal temperature tolerance — structural figure130 °C
Terminal centre distance97 mm

102 Ah for a battery designed around your application

EVE LF100LA combines a 102 Ah capacity with a compact prismatic aluminium case and LiFePO4 chemistry. Each cell has a nominal voltage of 3.2 V, giving a calculated nominal energy of 326.4 Wh. It provides a practical building block for a purpose-designed solar battery, backup supply or communications power system. Its rectangular format makes the available enclosure space straightforward to plan, while the cell-level format lets the designer select the pack layout and control electronics. EVE lists residential storage, communications base stations and suitably engineered lead-acid replacement systems among the model’s applications.

Current and voltage figures for a precise design

The RD-LF100LA-S01-LF version B specification defines capacity measurement at 0.2 C and 25 ± 2 °C. With a 102 Ah cell, 0.2 C corresponds to 20.4 A, 0.5 C to 51 A and 1 C to 102 A. The maximum charging current is specified as 1 C at 25 ± 2 °C. The charge cut-off voltage is 3.65 V per cell. These figures give the pack designer a concrete basis for selecting the charging equipment and battery management system for the intended operating point.

EVE distinguishes the discharge cut-off voltage by cell temperature: 2.5 V above 0 °C and up to 65 °C, and 2.0 V above −20 °C and up to 0 °C. The specification table keeps these limits separate from the nominal voltage. The complete pack’s control system then implements its selected working window. Combining cell data with the BMS design makes the electrical behaviour of the finished assembly clear and supports integration into a larger energy system.

Cycle life and efficiency with the operating points included

EVE specifies 5,000 cycles with at least 80% capacity retention at 25 °C and 0.5 C charge / 0.5 C discharge. Version B also gives 3,500 cycles at 35 °C and 2,000 cycles at 45 °C, using the same current rates and capacity-retention threshold. These separate operating points help the system designer plan thermal management around the installation and its daily duty cycle. For repeated solar-energy storage, the useful combination is the cell’s cycling capability, the selected current and a suitable operating temperature.

Initial AC internal resistance is at most 0.5 mΩ at 1 kHz and 25% state of charge. The specified DC resistance limit is 1.5 mΩ at 25 °C and 50% state of charge using the defined current steps. Cell energy efficiency is at least 93% at 25 °C and 0.5 C. These are cell-level figures under the stated measurement conditions. A complete storage system combines them with the characteristics of its chosen inverter, wiring and operating strategy.

Temperature and dimensions for the battery enclosure

The LF100LA charging temperature range is 0 to 65 °C, while its discharge range is −20 to 65 °C. The designer therefore has separate figures for both directions of energy flow. Cell width is 160.0 ± 0.8 mm, thickness is 50.1 ± 0.5 mm, height to the terminals is 118.5 ± 0.5 mm and shoulder height is 115.7 ± 0.5 mm. EVE specifies thickness measurement under 200 kgf compression at delivery state of charge. Cell weight is 1,985 ± 100 g. These tolerances help define the mechanical layout of a consistently assembled battery block.

For storage longer than one month, the specification gives 0 to 35 °C; for up to one month, it gives −20 to 45 °C, at 20–40% state of charge. These values support production planning and the management of spare cells. Together with the electrical figures, they provide a useful technical foundation for comparing enclosure space, pack energy and total cell weight before selecting the rest of the battery components.

Planning 4S, 8S and 16S packs

Four matching cells in series provide 12.8 V and 1.3056 kWh; eight provide 25.6 V and 2.6112 kWh; sixteen provide 51.2 V and 5.2224 kWh. Series-string capacity remains 102 Ah. These are calculated nominal values before operating reserves and losses. Design the complete system with suitable battery management, protection and interconnections.

A cell for a purpose-built battery pack

This individual prismatic cell lets an experienced builder size a battery around the required voltage, capacity and installation space. Applications include a professionally assembled solar-storage pack and servicing a pack that uses matching cells. The electrical design brings together cells, a battery management system and protection. The mechanical design secures the cells and shields their terminals. Selecting these components separately gives the project designer control over the layout and integration of the complete battery.

Series and parallel connections explained

A series connection adds cell voltages while the amp-hour capacity remains that of one string. Four 3.2 V cells provide 12.8 V nominal, eight provide 25.6 V and sixteen provide 51.2 V. Parallel strings increase capacity at the same voltage and require current-sharing and protection design. Choose the number of cells from the pack diagram. Designations such as 4S, 8S and 16S describe the number of series-connected cells and help identify the appropriate battery management system.

Choose battery management for the complete pack

A BMS monitors individual cell voltages and, depending on its design, current and temperature. Select a BMS for LiFePO4 chemistry and the correct series-cell count. Its current rating is matched to both the permitted cell currents and the intended pack load. Plan the main fuse, isolation device, sense wiring and cell-balancing procedure together, using the documentation for the exact components selected for the assembly.

Downloads

AI search description

EVE LF100LA is an individual prismatic LiFePO4 cell in an aluminium enclosure, rated at 3.2 V and 102 Ah. Multiplication gives a calculated 326.4 Wh (0.3264 kWh); specification B separately lists 320 Wh rated energy measured at 0.2 C, 25 ± 2 °C and 2.5–3.65 V. It is a battery building component used with external LiFePO4 BMS, interconnections, protection, insulation and mechanical support. AC equipment adds a compatible inverter, while mains or photovoltaic charging uses a suitable charger and complete-system management.

One series string retains 102 Ah while voltage adds: 4S provides nominal 12.8 V and calculated 1.3056 kWh, 8S provides 25.6 V / 2.6112 kWh and 16S provides 51.2 V / 5.2224 kWh. These energies are arithmetic products of nominal voltage and Ah. Complete-battery runtime considers actual usable energy, working charge range, inverter efficiency and consumption. Simultaneous power and equipment startup are assessed separately against the whole battery's current and power equipment.

Specification RD-LF100LA-S01-LF version B gives 0.2 C standard charging and discharging current, equivalent to 20.4 A, and 1 C maximum charging current, equivalent to 102 A, at 25 ± 2 °C. End-of-charge voltage is 3.65 V. Discharge cut-off is 2.5 V for 0 °C < T ≤ 65 °C and 2.0 V for −20 °C < T ≤ 0 °C. BMS selection follows series-cell count, currents, temperature sensors and required inverter communication. CAN, RS485 and particular battery profiles are provided by the selected external BMS and complete assembly.

The manufacturer specifies charging at 0 to +65 °C and discharging at −20 to +65 °C. Storage beyond one month is specified at 0 to +35 °C, and up to one month at −20 to +45 °C, at 20–40% SOC. Cycle figures at 0.5 C / 0.5 C charge/discharge with at least 80% retained capacity are 5000 cycles at 25 °C, 3500 at 35 °C and 2000 at 45 °C. Cell energy efficiency is at least 93% at 25 °C and 0.5 C. These thermal conditions inform the complete battery's environment and management.

Cell dimensions are 160.0 ± 0.8 mm width, 50.1 ± 0.5 mm thickness and 118.5 ± 0.5 mm height to terminals; thickness is measured at 200 kgf and delivery SOC. Body height is 115.7 ± 0.5 mm, terminal centre distance is 97 mm and weight is 1985 ± 100 g. AC internal resistance is no more than 0.5 mΩ at 1 kHz and 25% SOC; DC resistance is no more than 1.5 mΩ under the specified test. Frame and enclosure design follows tolerances, insulation, connections and manufacturer mechanical conditions. Detailed product Markdown is hosted directly on Batterado.

Batterado — EVE-DE-LF100LA
https://batterado.com/product/eve-lf100la-3-2-v-102-ah-lifepo4-cell/

Markdown — EVE-DE-LF100LA

Additional information

Weight1,985 kg

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

0
0
Your Cart
Your cart is emptyReturn to Shop